• Title/Summary/Keyword: Duration Curve

Search Result 445, Processing Time 0.032 seconds

A Study on Enhancing Load Power Factor Effectively Using Load Duration Curves and the Power Factor Sensitivity of Generation Cost (부하지속곡선과 부하역률 감도기법 적용에 의한 효과적인 부하역률개선 연구)

  • Lee, Byung-Ha;Kim, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.480-482
    • /
    • 2005
  • In this paper, utilization of load duration curves is presented for analyzing the effect of load power factor and determining the value of load power factor effectively. In addition, the power factor sensitivity of generation cost and integrated costs including voltage variation penalty cost are used for determining the value of the load power factor from the point of view of voltage regulation and economic investment. It is shown through the application to the KEPCO power system that the load power factor can be enhanced effectively and appropriately using the load duration curve.

  • PDF

Determining the flow curves for an inverse ferrofluid

  • Ekwebelam, C.C.;See, H.
    • Korea-Australia Rheology Journal
    • /
    • v.20 no.1
    • /
    • pp.35-42
    • /
    • 2008
  • An inverse ferrofluid composed of micron sized polymethylmethacrylate particles dispersed in ferrofluid was used to investigate the effects of test duration times on determining the flow curves of these materials under constant magnetic field. The results showed that flow curves determined using low duration times were most likely not measuring the steady state rheological response. However, at longer duration times, which are expected to correspond more to steady state behaviour, we noticed the occurrence of plateau and decreasing flow curves in the shear rate range of $0.004\;s^{-1}$ to ${\sim}20\;s^{-1}$, which suggest the presence of nonhomogeneities and shear localization in the material. This behaviour was also reflected in the steady state results from shear start up tests performed over the same range of shear rates. The results indicate that care is required when interpreting flow curves obtained for inverse ferrofluids.

Empirical Equation for Pollutant Loads Delivery Ratio in Nakdong River TMDL Unit Watersheds (낙동강 오염총량관리 단위유역 유달율 경험공식)

  • Kim, Mun Sung;Shin, Hyun Suk;Park, Ju Hyun;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.4
    • /
    • pp.580-588
    • /
    • 2009
  • In this study daily flow rates and delivered pollutant loads of Nakdong river basin are simulated with modified TANK model and minimum variance unbiased estimator. Based on the simulation results, flow duration curves, load duration curves, and delivery ratio duration curves have been established. Then GIS analysis is performed to obtain several hydrological geomorphic characteristics such as watershed area, stream length, watershed slope and runoff curve number. Finally, multiple regression analysis is carried out to estimate empirical equations for pollutants delivery ratio. The results show that there is positive relation between the flow rates and delivery ratios, and the proposed empirical formulas for delivery ratio can predict well river pollutant loads.

Effects of Urban Freeway Incidents on Traffic Congestion (도시고속도로 유고가 교통혼잡에 미치는 영향)

  • 권희철;황상호
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.22 no.49
    • /
    • pp.125-133
    • /
    • 1999
  • Nonrecurring congestions are generally caused by random or less predictable events, such as accidents, spilled loads stalled or broken-down vehicles that, temporarily reduce the capacity of the freeway. The purpose of this paper is to present the effect of incidents on the traffic congestion on the urban freeway by simulation method. The simulation scenario is composed of two level traffic conditions, two level incident severities, and eight level incident durations. After incident, the recovering duration to the normal traffic flow, increased by linear of incident duration. Total vehicles travel time increased and average travel speed decreased by squares curve of incident duration. Considering incident impacts, incident management system is evaluated the major function of the urban freeway traffic management system. Also, necessary the related research to detect, verify, and develop effective response strategies for traffic incidents.

  • PDF

The Effect of Evaporative Cooling in Alleviating Seasonal Differences in Milk Production of Almarai Dairy Farms in the Kingdom of Saudi Arabia

  • Ali, A.K.A.;AL-Haidary, A.A.;Alshaikh, M.A.;Hayes, E.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.4
    • /
    • pp.590-596
    • /
    • 1999
  • The effect of evaporative cooling in alleviating seasonal variations of dairy cows raised in AlMarai Dairy Farms in the Kingdom of Saudi Arabia were studied using milking record collected during the period of 1991 to 1996. The data included 13303 and 8137 records represented winter and summer calving seasons. Evaporative cooling system improved production for cows calved in summer. The least square means of milk yield were 9631 and 9556 liter for cows calved in winter and summer seasons but no significant differences (p<0.05) were observed between the yield of two seasons. No significant effect of season on calving under evaporative cooling on most of the biweekly points of the lactation curve. The farm, parity and milk level showed a significant effect on the shape of the curve. Functions of the lactation curve like initial yield, 305 MY, peak yield, time of peak and duration were estimated for each phase of the lactation curve.

Lactation and Function of Curve Parameters in Yankasa Sheep

  • Afolayan, R.A.;Abubakar, B.Y.;Osinowo, O.A.;Dim, N.I.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.6
    • /
    • pp.890-894
    • /
    • 2002
  • The accuracy of the gamma function to describe lactation curve of Yankasa ewes was investigated using milk production data obtained from 168 ewes with either complete or incomplete 84 day lactation records. Ewes were daily hand milked after over-night separation from lamb and thorough disinfection of the udder. The daily milk yield on the average was estimated from the weekly total yield. The effect of type of birth, parity, season of birth and lactation length on the components of lactation curve (a, b, c and s) were analysed by least-square procedures. All factors except parity significantly (p<0.01) influenced the curve parameters. The goodness of fit of the function did not differ between the two classes of varying duration of lactation; incomplete lactation however, showed a lower persistency and as expected lower level of production. Correlations ($r_p$) between lamb weight gain and milk yield using the weight records from lamb weighed at weekly intervals indicated a high and positive relationship in the early lactation that decreased in intensity as the lactation advanced.

Probabilistic Optimal Weekly Coordination of Thermal-Pumped Storage Power System based on the Maximum Principle (최대원리에 의한 화력-양수발전시스템의 확률적 운전시뮬레이션 모델)

  • Lee, Bong-Yong;Shim, Keon-Bo
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.411-416
    • /
    • 1991
  • Operation simulation is a key factor to evaluate investment and operation in a power utility. Probabilistic production simulation is of major concern. With pumped-storage plant, production simulation is not an easy task, because its economy should fully be exploited. In addition, usual operation interval is a week rather than a day. Most existing models are based on approximate production simulation such as adopting simple priority orders of generations. This study is based on the more elaborate model developed by authors. Further, a policy of weekly coordination is established based on the Maximum Principle. Chronological load curve instead of usual load duration curve is used and the accuracy in simulation is enhahced. Resulting economics are compared. Deviation between these two toad curve is shown.

  • PDF

Simplified Evaluation Method for Residual Bond Strength of Reinforced Concrete Using Standard Fire Curve (표준화재곡선을 이용한 잔존부착강도 평가 간략방법 제안)

  • Moon, Do-Young
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.5
    • /
    • pp.41-47
    • /
    • 2010
  • For the enhancement of structural safety of thermally damaged reinforced concrete structure, rapid evaluation of damage in the structure is very important. This study addresses a simplified method which is equivalent to the standard fire curve (ISO 834) for the residual bond strength evaluation. In the proposed method, a exposure duration as well as the maximum temperature can be considered. For the comparisons with conventional methods, concrete properties obtained from the report of Daegu subway fire accident were referred and the results support the applicability of the proposed method in this study.

Effect of Hysteresis on Soil-Water Characteristic Curve in Weathered Granite and Gneiss Soil Slopes during Rainfall Infiltration (풍화계열 사면의 불포화 함수특성곡선 이력이 강우 침투에 미치는 영향)

  • Shin, Gil-Ho;Park, Seong-Wan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.28-33
    • /
    • 2006
  • Shallow failures of slopes in weathered soils are caused by infiltration due to prolonged rainfall. These failures are mainly triggered by the deepening of the wetting band accompanied by a decrease in suction induced by the water infiltration. In this paper, hysteresis on soil-water characteristic curve(SWCC) of granite and gneiss weathered soils are investigated using transient flow analysis respectively. Each case was subjected to artificial rainfall intensities and time duration depending on the laboratory-based drying and wetting processes. The results show that the unsaturated seepage on weathered slopes are very much affected by the initial suction of soils and unsaturated permeability of the soils. In addition, a granite weathered soil has a lower air-entry value, residual matric suction, and wetting front suction and less hysteresis loop than a gneiss weathered soil.

  • PDF

2-Step Modeling for Daily Load Curve of Up to and Including 100kVA Distribution Transformer (100kVA 이하급 배전용 변압기 일부하 패턴의 2-Step 모델링)

  • Lee, Young-Suk;Kim, Jae-Chul;Yun, Sang-Yun
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.371-373
    • /
    • 2001
  • In this paper, we present 2-step load cycle for daily load curve of up to and including 100kVA distribution transformer in domestic. Daily load patterns are classified by two methods dependent upon possession information. In case we possess daily load profiles make use of K-mean algorithm and in case we have not daily load profiles, make use of customer information of KEPCO. As the parameters of the load pattern classification, we use are daily load profiles and customer information of each distribution transformers. Data management system is used for NT oracle. We can present peak load magnitude, initial load magnitude and peak load duration for daily load patterns by 2-step load cycle for daily load curve of up to and including 100kVA distribution transformer in domestic. We think that this paper contributes to enhancing the distribution transformer overload criterion.

  • PDF