• Title/Summary/Keyword: Duck detection

Search Result 188, Processing Time 0.026 seconds

Short-circuit Analysis by the Application of Control Signal of Power Converter to the Inductive Fault Current Limiter

  • Ahn, Min-Cheol;Hyoungku Kang;Bae, Duck-Kweon;Minseok Joo;Park, Dong-Keun;Lee, Sang-Jin;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.2
    • /
    • pp.25-28
    • /
    • 2004
  • Three-phase inductive superconducting fault current limiter (SFCL) with DC reactor rated on 6.6 $KV_{rms}/200 A_{rms}$ has been developed in Korea. This system consists of one DC reactor, AC/DC power converter, and a three-phase transformer, which is called magnetic core reactor (MCR). This paper deals with the short-circuit analysis of the SFCL. The DC reactor was the HTS solenoid coil whose inductance was 84mH. The power converter was performed as the dual-mode operation for dividing voltage between the rectifying devices. The short-term normal operation (1 see) and short-circuit tests (2∼3 cycles) of this SFCL were performed successfully. In regular short-circuit test, the fault current was limited as 30% of rated short-circuit current at 2 cycles after the fault. The experimental results have a very similar tendency to the simulation results. Using the technique for the fault detection and SCR firing control, the fault current limiting rate of the SFCL was improved. From this research, the parameters for design and manufacture of large-scale SFCL were obtained.

A study on the detection method of inner's crack of STS304 pipe using Ultrasonic Testing (초음파 검사법을 이용한 STS304 배관재 내부 균열 측정 방법에 대한 연구)

  • Hwang, Woong-Gi;Lee, Kyung-Min;Woo, Young-Kwan;Seo, Duck-Hee;Lee, Bo-Young
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.415-418
    • /
    • 2011
  • Thermal fatigue is one of the life-limiting damage mechanisms in the nuclear power plant conditions. The turbulent mixing of fluids of different temperatures induces rapid temperature changes to the pipe wall. The successive thermal transients cause varying cyclic thermal stresses. These cyclic thermal stresses cause fatigue crack nucleation and growth similar to the cyclic mechanical stresses. The aim of this study was to fulfil the need by developing an real crack manufacturing method, which would produce realistic cracks. The test material was austenitic STS 304, which is used as pipelines in the reactor coolant system of a nuclear power plants. In order to fabricate thermal fatigue crack similar to realistic crack, successive thermal transients were applied to the specimen. Thermal transient cycles were combined with heating (60sec) and cooling cycle (30sec). And, In order to identify ultrasonic characteristic, it was performed the ultrasonic reflection measuring method for the fabricated specimen. From the results of ultrasonic reflection measuring testing, it was conformed that A-scan results(average 83% of real crack depth) for the TFC reference specimen was more enhanced NDT reliability than results(average 38% of real crack depth) for the EDM notch reference specimen.

  • PDF

Detection of Corrosion and Wall Thinning in Carbon Steel Pipe Covered With Insulation Using Pulsed Eddy Current

  • Park, Duck-Gun;Kishore, M.B.;Kim, J.Y.;Jacobs, L.J.;Lee, D.H.
    • Journal of Magnetics
    • /
    • v.21 no.1
    • /
    • pp.57-60
    • /
    • 2016
  • Non Destructive Testing (NDT) methods that are capable of detecting the wall thinning and defects through insulation and cladding sheets are necessary. In this study we developed a Pulsed Eddy Current (PEC) system to detect wall thinning of ferro magnetic steel pipes covered with 95 mm thick fiber glass thermal insulator and shielded with aluminum plate of thickness 0.4 mm. In order to confirm the thickness change due to wall thinning, two different sensors, a hall sensor and a search coil sensor were used as a detecting element. In both the cases, the experimental data indicates a considerable change in the detected pulse corresponding to the change in sample thickness. The thickness of the tube was made to change such as 2.5 mm, 5 mm and 8 mm from the inner surface to simulate wall thinning. Fast Fourier Transform (FFT) was calculated using window approach and the results were summarized which shows a clear identification of thickness change in the test specimen by comparing the magnitude spectra.

Struvite recovery from swine wastewater and its assessment as a fertilizer

  • Ryu, Hong-Duck;Lee, Sang-Ill
    • Environmental Engineering Research
    • /
    • v.21 no.1
    • /
    • pp.29-35
    • /
    • 2016
  • This study evaluated the fertilizing value of struvite deposit recovered from swine wastewater in cultivating lettuce. Struvite deposit was compared to complex fertilizer, organic fertilizer and compost to evaluate the fertilizing effect of struvite deposit. Laboratory pot test showed that the struvite deposit better enhanced lettuce growth in comparison to commercial fertilizers. It was revealed that the growth rate of lettuce was simultaneously controlled by phosphorus (P) and magnesium (Mg). Moreover, nutrients such as nitrogen (N), P, K, calcium (Ca) and magnesium (Mg) were abundantly observed in the vegetable tissue of struvite pot. Meanwhile, struvite application led to the lower accumulation of mercury (Hg), lead (Pb), chromium ($Cr^{6+}$) and nickel (Ni). In addition, no detection of cadmium (Cd), arsenic (As) and nickel (Ni) in the lettuce tissue was observed in struvite application pots. The experimental results proved that the optimum struvite dosage for lettuce cultivation was 0.5 g struvite/kg soil. The column experiments clearly showed that ammonia nitrogen was more slowly released from struvite deposit than from complex fertilizer. Consequently, it was concluded that the struvite deposits recovered from swine wastewater were effective as a multi-nutrient fertilizer for lettuce cultivation.

Synthesis of Azo-functionalized Calix[4]arenes and Its Application to Chloride-selective Electrode as Ionophores

  • Lee, Hyo-Kyoung;Yeo, Hee-Kyoung;Park, Duck-Hee;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.12
    • /
    • pp.1737-1741
    • /
    • 2003
  • Azo-functionalized calix[4]arenes as ionophores for chloride-selective electrode, 5,11,17,23-Tetra-tert-butyl-25,27-bis[(N,N-dimethyl-aniline-azo-phenylthioureido)ethyl]oxy-26,28-dihydroxycalix[4]arene (4a) and 5,11,17,23-Tetra-tert-butyl-25,27-bis[(N,N-dimethyl-aniline-azo-phenylthioureido)ethyl]oxy-26,28-dimethoxycalix[4]arene (4b) were synthesized. The PVC membrane electrode based on azo-functionalized calix[4]arene 4a with o-NPOE exhibits a linear stable response over a wide concentration range ($1.5{\times}10^{-4}-1.0{\times}10^{-1}$) with a slope of -52.0 mV/decade and a detection limit of log[$Cl^-$] = -4.02. This ionophore-based membrane exhibited improved selectivity for chloride anion compared with classical Hofmeister series.

Simultaneous Determination of the Water Soluble Vitamins in Multi-Nutrient Tablets by Reversed-Phase High-Performance Liquid Chromatography

  • Kim, Hyung-Soo;Jang, Duck-Kyu;Woo, Dong-Kyun;Woo, Kang-Lyung
    • Preventive Nutrition and Food Science
    • /
    • v.7 no.1
    • /
    • pp.12-17
    • /
    • 2002
  • Simultaneous determination of nine water-soluble vitamins contained in multi-nutrient tablets was carried out by reversed phase high-performance liquid chromatography (RP-HPLC) equipped with analytical $C_{18}$ column and UV (270 nm) detector. Those standard vitamins were successfully separated within 23 minutes by gradient elution with solvent A (0.5 M potassium phosphate monobasic) and solvent B (0.25 M potassium phosphate monobasic-methanol, 1:1). Calibration curves showed good linealities with correlation coefficients (> 0.92) in tested ranged respectively. The detection limits were considered to be 2.1 ng for ascorbic acids 60 ng for Vit B$_{6}$ 3 ng for p-aminobenzoic acid, 9 ng for niacinamide, 9 ng for thiamin, 5.0 ng for folic acid and 1.5 ng for riboflavin at 0.05 a.u.f.s. Solid phase extraction through Sep-Pak (C$_{18}$ ) cartridge was successfully applied for purification of water soluble vitamins in commercial multi-nutrient tablets.ts.

Rotor Position Sensing Method for Switched Reluctance Motors Using an Indirect Sensor

  • Shin Duck-Shick;Yang Hyong-Yeol;Lim Young-Cheol;Freere Peter;Gurung Krishna
    • Journal of Power Electronics
    • /
    • v.5 no.3
    • /
    • pp.173-179
    • /
    • 2005
  • In this paper, a very low cost and robust sensing method for the rotor position of a TSRM(Toroidal Switched Reluctance Motors) is described. Position information of the rotor is essential for SRM drives. The rotor position sensor such as an opto-interrupter or high performance encoder is generally used for the estimation of rotor position. However, these discrete position sensors not only add complexity and cost to the system but also tend to reduce the reliability of the drive system. In order to solve these problems, in the proposed method, rotor position detection is achieved using voltage waveforms induced by the time varying flux linkage in the search coils, and then the appropriate phases are excited to drive the SRM. But the search coil's EMF is generated only when the motor rotates. Therefore the rotor position sensing method using squared Euclidean distance at a standstill is also examined. The simulation and experimental results are presented to verify the performance of the proposed method in this paper.

Spectrum Analysis of VHF/UHF PD in Simulated Transformer (모의 변압기의 VHF/UHF PD 스펙트럼 분석)

  • Kim, Duck-Keun;Kim, Jong-Seo;Lim, Yong-Bae;Lim, Jang-Seob;Moon, Chae-Ju
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.50-54
    • /
    • 2000
  • Recently, the HFPD measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Also HFPD testing is able to offer the judgement standard of degradation level of HV machine and can detect discharge signals in live-line. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

A Study on the Pattern Recognition Using of HFPD the Neural Networks and ${\Delta}F$ (신경회로망 및 ${\Delta}F$를 이용한 부분방전 패턴인식에 관한 연구)

  • Lim, Jang-Seob;Kim, Duck-Keun;Kim, Jin-Gook;Noh, Sung-Ho;Kim, Hyun-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.251-254
    • /
    • 2004
  • The aging diagnosis technique using partial discharge detection method detects partial discharge signals cause of power equipment failuer and able to forecast the aging state of insulation system through analysis algorithm, in this paper accumulates HFPD signal during constant scheduled cycles to build HFPD pattern and then analyzes HFPD pattern using statistical parameters and ${\Delta}F$ pattern. The 3D pattern is composed of detected signal frequency, amplitude and repeated number and the FRPDA(frequency resolved partial discharge analysis) technique is used in 3D pattern construction. The ${\Delta}F$ pattern shows variation characteristics of amplitude gradient of consecutive HFPD signal Pulses and able to classify discharge types-internal discharge, surface discharge and coronal discharge etc. Fractal mathematics applied to ${\Delta}F$ pattern quantification and neural networks is used in aging diagnostic algorithm.

  • PDF

Comparative bioavailability of synthetic vitamin C and Nutra-C (calcium ascorbate) in Korean healthy volunteers

  • Choi, Kyung-Mi;Hoon, Kim Man;Won, Hwang Tae;Kim, Jong-Dae;Park, Keum duck;Kim, Mi-Young;Jung, Young-Rim;Shin, Hye-Seoung
    • Analytical Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.162-169
    • /
    • 2016
  • The purpose of this study was to compare the relative bioavailability of synthetic Vitamin C and Nutra-C® (calcium ascorbate) using a randomized parallel pharmacokinetics study design. Under fasting conditions, 20 healthy volunteers were randomly allocated to receive a single oral dose (500 mg of ascorbic acid) of either synthetic Vitamin C or Nutra-C®. Fasting blood was collected pre-dose and 1, 2, 3, 4, 7 and 10 hr post-dose. The ascorbic acid content of human serum was determined using HPLC with ultraviolet detection. The fasting serum ascorbic acid concentrations of synthetic Vitamin C and Nutra-C® were 6.734 ± 2.09 ng/mL (n = 10) and 7.542 ± 2.96 ng/mL (n = 10), respectively. The bioavailability of Nutra-C® was significantly greater (128 %, p < 0.05) than that of the synthetic Vitamin C.