• Title/Summary/Keyword: Dual-Energy X-Ray Imaging

Search Result 41, Processing Time 0.021 seconds

Image Restoration in Dual Energy Digital Radiography using Wiener Filtering Method

  • Min, Byoung-Goo;Park, Kwang-Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.171-176
    • /
    • 1987
  • Wiener filtering method was applied to the dual energy imaging procedure in digital radiography(D.R.). A linear scanning photodiode arrays with 1024 elements(0.6mm H 1.3mm pixel size) were used to obtain chest images in 0.7 sec. For high energy image acquisition, X-ray tube was set at 140KVp, 100mA with a rare-earth phosphor screen. Low energy image was obtained with X-ray tube setting at 70KVp, 150mA. These measured dual energy images are represented in the vector matrix notation as a linear discrete model including the additive random noise. Then, the object images are restored in the minimum mean square error sense using Wiener filtering method in the transformed domain. These restored high and low energy images are used for computation of the basis image decomposition. Then the basis images are linearly combined to produce bone or tissue selective images. Using this process, we could improve the signal to noise ratio characteristics in the material selective images.

  • PDF

Photon-Counting Detector CT: Key Points Radiologists Should Know

  • Andrea Esquivel;Andrea Ferrero;Achille Mileto;Francis Baffour;Kelly Horst;Prabhakar Shantha Rajiah;Akitoshi Inoue;Shuai Leng;Cynthia McCollough;Joel G. Fletcher
    • Korean Journal of Radiology
    • /
    • v.23 no.9
    • /
    • pp.854-865
    • /
    • 2022
  • Photon-counting detector (PCD) CT is a new CT technology utilizing a direct conversion X-ray detector, where incident X-ray photon energies are directly recorded as electronical signals. The design of the photon-counting detector itself facilitates improvements in spatial resolution (via smaller detector pixel design) and iodine signal (via count weighting) while still permitting multi-energy imaging. PCD-CT can eliminate electronic noise and reduce artifacts due to the use of energy thresholds. Improved dose efficiency is important for low dose CT and pediatric imaging. The ultra-high spatial resolution of PCD-CT design permits lower dose scanning for all body regions and is particularly helpful in identifying important imaging findings in thoracic and musculoskeletal CT. Improved iodine signal may be helpful for low contrast tasks in abdominal imaging. Virtual monoenergetic images and material classification will assist with numerous diagnostic tasks in abdominal, musculoskeletal, and cardiovascular imaging. Dual-source PCD-CT permits multi-energy CT images of the heart and coronary arteries at high temporal resolution. In this special review article, we review the clinical benefits of this technology across a wide variety of radiological subspecialties.

Inspection of electronic components using dual X-ray energy (이중 엑스선 에너지를 이용한 전자부품 검사)

  • Chon, Kwon Su;Seo, Seung Jun;Lim, Jae Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.301-306
    • /
    • 2015
  • X-ray can be applied to obtain a projection image of an object. It is not easy to obtain an high quality image for the object composed of low and high density materials. For the object with large difference in density, it is possible to realize high contrast image using images of low and high tube voltages and image processing. The plastic and metalic parts of the electronic components can be imaged by the dual energy technique which use low and high tube voltages and by processing pixel-by-pixel using visual C++. The contrast-enhanced image can be used to detect and observe defects within the electronic components.

Basic Physical Principles and Clinical Applications of Computed Tomography

  • Jung, Haijo
    • Progress in Medical Physics
    • /
    • v.32 no.1
    • /
    • pp.1-17
    • /
    • 2021
  • The evolution of X-ray computed tomography (CT) has been based on the discovery of X-rays, the inception of the Radon transform, and the development of X-ray digital data acquisition systems and computer technology. Unlike conventional X-ray imaging (general radiography), CT reconstructs cross-sectional anatomical images of the internal structures according to X-ray attenuation coefficients (approximate tissue density) for almost every region in the body. This article reviews the essential physical principles and technical aspects of the CT scanner, including several notable evolutions in CT technology that resulted in the emergence of helical, multidetector, cone beam, portable, dual-energy, and phase-contrast CT, in integrated imaging modalities, such as positron-emission-tomography-CT and single-photon-emission-computed-tomography-CT, and in clinical applications, including image acquisition parameters, CT angiography, image adjustment, versatile image visualizations, volumetric/surface rendering on a computer workstation, radiation treatment planning, and target localization in radiotherapy. The understanding of CT characteristics will provide more effective and accurate patient care in the fields of diagnostics and radiotherapy, and can lead to the improvement of image quality and the optimization of exposure doses.

A Study on the X-Ray Imaging using Dusl Energy Method (이중에너지 방법을 이용한 X선 영상법에 관한 연구)

  • 신동익;김종효
    • Journal of Biomedical Engineering Research
    • /
    • v.9 no.2
    • /
    • pp.185-194
    • /
    • 1988
  • The dual-energy technique win used to separate the bone-only and tissue-only images from the conventional chest images. The equivalent thickness of the basic materials are estimated from low and high energy images of a given complex materials using the attenuation coefficient of ma serial componens. We showed that the image quality of dual-energy imaging method can be influenced by the ponlinearity and noise components of system and spectrum distributions The quantitative analysis of Calcium component was performed by dual-energy technique and it is shown that the concentration of the Calcium could be accurately estimated within 5% error range.

  • PDF

An Experimental Study of Radiographic Density of Alveolar Bone and Cortical Thickness of Mandible by Osteoporosis (골다공증에 따른 치조골 방사선사진농도와 하악하연두께의 변화에 대한 연구)

  • Lee Byeong-Do
    • Imaging Science in Dentistry
    • /
    • v.30 no.4
    • /
    • pp.235-242
    • /
    • 2000
  • Purpose: To evaluate the effect of the systemic osteoporosis on radiographic density of alveolar bone and cortical thickness of mandible. Materials and Methods: The bone mineral density values of lumbar and femur were measured by dual-energy X-ray absorptiometry and T scores of lumbar, femur were obtained respectively. Radiographic densities of alveolar bones and panorama mandibular index (PMI, represents as cortical thickness) were analysed statistically according to age and T score variables. Results: The radiographic density of alveolar bone of maxillary molar showed significant difference by age and femur T group. That of mandibular molar showed significant difference between femur T group. Panorama mandibular index showed significant difference between age groups. Conclusion: The radiographic density of alvealar bones was more dependent on age and femur T than lumbar T. Cortical thickness of mandible was correlated with increasing age.

  • PDF

Bone Density Spatial Distribution of Radiation Dose Measurement (양방사선 골밀도 측정 장치의 공간산란선량분포측정)

  • Kim, Seon-Chil;Won, Do-Yeon;Park, Chang-Hee;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.59-62
    • /
    • 2011
  • In this experiment, how DEXA(Dual-energy X-ray Absorptiometry) bone mineral density was measured using the equipment. In order to maintain the same measurement conditions, bone mineral density measurements of 10 cm thick phantom, with an actual patient at a point when examining the same conditions(100 kVp, 1 mA) and then out to the five doses of radiation and its average was calculated by dividing measured. X-ray dose rate measured at the Research Institute, Sword of the gamma survey meters calibrated MEDCOM Ltd. (Inspector GM counter tube) was used, calibration factor is 1.15. On a horizontal plane around the patient, depending on the distance was significantly reduced dose rate. In addition, orientation $0^{\circ}$ head end was higher in the direction of the highest dose rate, $0^{\circ}$ $180^{\circ}$ direction from the direction towards the higher dose rate reduced to some extent in the direction of all the $120^{\circ}$ were able to identify.

  • PDF

Optimization Study of Digital X-ray Imaging with Dual Energy Subtraction Method (듀얼 에너지 감산기법을 이용한 디지털 X-ray 영상 최적화에 관한 연구)

  • Kim, Dae Ho;Lee, Yong-Gu;Lee, Youngjin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.10
    • /
    • pp.138-142
    • /
    • 2016
  • Dual-energy digital radiography (DEDR) has been used for detecting lesions within the body using energy subtraction methods. The purpose of this study was to acquire optimal bone and tissue image by changing physical factors such as Tube voltage (kVp) and add filters, and then we compared with the predicted values using SRS-78 program and experimental results. For that purpose, we acquired images according to changes in physical parameters of various materials since we had to acquire the optimal bone and tissue image using energy subtraction. Used phantom consists of aluminum and polymethyl methacrylate (PMMA) and a comparison of image optimization was measured by contrast-to-noise ratio (CNR). In results, first of all, we confirmed that a subtraction image from 50 kVp image and 120 kVp image is optimal bone and tissue image. Also when we added a 10 mm Aluminum add filter, we expected it is a result of the optimal bone and tissue image. Besides, we confirmed these results are consistent with the predicted optimized condition by SRS-78 program.. In conclusion, we indicated that we can acquire optimal bone and tissue image by controling physical factors such as kVp, add filters through this study. Also we expected that DEDR will contribute to the field of medical imaging technology.

BMD Analysis according to the Obesity Index in a Group of Adults (비만도에 따른 성인들의 집단별 골밀도 분석)

  • Kim, Sun-Geun;Kweon, Dae-Cheol;Oh, Chan-Ho;Song, Woon-Heung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.51-58
    • /
    • 2008
  • Obesity which causing many physical and psychological problems is difficult to treatment. The purpose study was investigate relationships between weight, height, body mass index (BMI) and BMD of according to the low, normal, over, obesity, high group. According to obesity index, each group was divided into five proup. Study subjects were man(n=135) and woman(n=145). We checked the BMD of femoral neck and lumbar spine by using dual energy X-ray bone densitometry. Weight was positively correlation with height (p<0.05) by Pearson's correlation matrix. There was a significant difference in BMD of femoral neck and lumbar spine between four(low, normal, over, obesity) groups except for high obesity groul.

  • PDF

A Pilot Study on Hip Bone Mineral Densities Estimation from Forearm CBCT images

  • Ko, Hoon;Lee, Chang-Hoon;Jeong, Kwanmoon;Lee, Myeung Su;Nam, Yunyoung;Yoon, Kwon-Ha;Lee, Jinseok
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.12
    • /
    • pp.6054-6068
    • /
    • 2017
  • In this paper, we defined the relative cross-sectional area of forearm cortical bone and investigated its correlation with hip bone mineral density values of total femur, femoral neck, femoral trochanter, femoral inter-trochanter and femoral ward's triangle, respectively. Based on the correlations, we established a linear transformation between the relative cross-sectional area of forearm cortical bone and each hip bone BMD. We obtained forearm images using CBCT and hip bone BMDs using dual-energy X-ray absorptiometry (DXA) for 28 subjects. We also investigated the optimal forearm region to provide the strongest correlation coefficient. We used the optimized forearm region to establish each linear transformation to estimate BMD values for total femur, femoral neck, femoral trochanter, femoral inter-trochanter and femoral ward's triangle from the relative cross-sectional area of forearm cortical bone, respectively. We observed the strong correlations with total femur (r=0.889), femoral neck (r=0.924), femoral trochanter (r=0.821), femoral inter-trochanter (r=0.867) and femoral ward's triangle (r=0.895), respectively. The strongest correlation was observed in the forearm mid-shaft regions. Our results suggest that the hip bone BMD values can be simply estimated from forearm CBCT images in a convenient sitting position without X-ray exposure on a hip including genital organs, and may be useful for screening osteoporosis.