• 제목/요약/키워드: Dual Damper System

검색결과 22건 처리시간 0.021초

Robust Minimum-Time Control with Coarse/Fine Dual-Stage Mechanism

  • Kwon, Sang-Joo;Cheong, Joo-No
    • Journal of Mechanical Science and Technology
    • /
    • 제20권11호
    • /
    • pp.1834-1847
    • /
    • 2006
  • A robust minimum-time control (RMTC) strategy is addressed and it is extended to the dual-stage servo design. Rather than conventional switching type sub-optimal controls, it is a reference following control approach where the predetermined minimum-time trajectory (MTT) is tracked by the perturbation compensator based feedback controller. First, the minimum-time trajectory for a mass-damper system is derived. Then, the perturbation compensator to achieve robust tracking performance in spite of model uncertainty and external disturbance is suggested. The RMTC is also applied to the dual-stage positioner which consists of coarse actuator and fine one. To best utilize the actuation redundancy of the dual-stage mechanism, a null-motion controller to actively regulate the relative motion between the two stages is formulated. The performance of RMTC is validated through simulation and experiment.

진동주기가 다른 듀얼프레임을 이용한 내진보강시스템의 성능검증을 위한 실험적 연구 (An Experiment Study on Verification for the Performance of Seismic Retrofit System Using of Dual Frame With Different Eigenperiod)

  • 오상훈;최광용;유홍식;김영주
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권5호
    • /
    • pp.91-100
    • /
    • 2018
  • 본 연구에서 제안하는 내진보강기법은 듀얼시스템으로 비내진상세로 설계된 저층구조물을 대상으로 적용하기 위한 기법이다. 듀얼시스템은 기존의 구조체, 외부보강체, 강재이력댐퍼로 구성되고 구조체와 외부보강체 사이에 강재이력댐퍼를 설치한다. 구조체와 외부보강체는 강성과 적재하중에 의해 서로 다른 주기에 의해 상대변위가 발생되고 강재이력댐퍼를 통해 지진에너지를 흡수한다. 본 연구에서 제안된 듀얼시스템의 내진성능을 검증하기 위해 동적실험을 수행한다. 동적 실험결과, 듀얼시스템 보강 시 에너지가 1.84배 더 많이 입력됨에도 불구하고 56%의 변형 저감과, 93%의 손상 저감이 됨에 따라 듀얼시스템 적용 시 내진성능을 향상시킬 것으로 판단된다. 그리고 연구결과는 듀얼시스템의 설계범위를 설정하기 위한 추후 연구의 기초자료로 제시하고자 한다.

이종 복합 메카니즘 HIF 기구의 충격저감시스템 해석 (Analysis of Isolation System in Distinct Multi-mechanism HIF Device)

  • 최의중;김효준
    • 한국정밀공학회지
    • /
    • 제22권2호
    • /
    • pp.53-59
    • /
    • 2005
  • In this study, the isolation system for multi-mechanism HIF (high impulsive force) device has been investigated. For this purpose, parameter optimization process has been performed based on the simplified isolation system model under constraints of moving displacement and transmitted force. The design parameters for multi-mechanism HIF device have been derived with respect to HIF system I and HIF system II, respectively. In order to implement the dynamic absorbing system, the dual stage hydro-pneumatic damper and magnetorheological damper with semi-active control scheme are considered. Finally, the performance of the designed prototype isolation system has been evaluated by experimental works under actual operating conditions.

벽체-감쇠 복합시스템을 갖는 건물의 지진취약도 분석 (Seismic Fragility Analysis of Buildings With Combined Shear Wall-Damper System)

  • 라지불 이슬람;수딥타 차크라보르티;공병진;김두기
    • 한국지진공학회논문집
    • /
    • 제27권2호
    • /
    • pp.91-99
    • /
    • 2023
  • Structural vibration induced by earthquake hazards is one of the most significant concerns in structure performance-based design. Structural hazards evoked from seismic events must be properly identified to make buildings resilient enough to withstand extreme earthquake loadings. To investigate the effects of combined earthquake-resistant systems, shear walls and five types of dampers are incorporated in nineteen structural models by altering their arrangements. All the building models were developed as per ACI 318-14 and ASCE 7-16. Seismic fragility curves were developed from the incremental dynamic analyses (IDA) performed by using seven sets of ground motions, and eventually, by following FEMA P695 provisions, the collapse margin ratio (CMR) was computed from the collapse curves. It is evident from the results that the seismic performance of the proposed combined shear wall-damper system is significantly better than the models equipped with shear walls only. The scrutinized dual seismic resisting system is expected to be applied practically to ensure a multi-level shield for tall structures in high seismic risk zones.

Performance of a 3D pendulum tuned mass damper in offshore wind turbines under multiple hazards and system variations

  • Sun, Chao;Jahangiri, Vahid;Sun, Hui
    • Smart Structures and Systems
    • /
    • 제24권1호
    • /
    • pp.53-65
    • /
    • 2019
  • Misaligned wind-wave and seismic loading render offshore wind turbines suffering from excessive bi-directional vibration. However, most of existing research in this field focused on unidirectional vibration mitigation, which is insufficient for research and real application. Based on the authors' previous work (Sun and Jahangiri 2018), the present study uses a three dimensional pendulum tuned mass damper (3d-PTMD) to mitigate the nacelle structural response in the fore-aft and side-side directions under wind, wave and near-fault ground motions. An analytical model of the offshore wind turbine coupled with the 3d-PTMD is established wherein the interaction between the blades and the tower is modelled. Aerodynamic loading is computed using the Blade Element Momentum (BEM) method where the Prandtl's tip loss factor and the Glauert correction are considered. Wave loading is computed using Morison equation in collaboration with the strip theory. Performance of the 3d-PTMD is examined on a National Renewable Energy Lab (NREL) monopile 5 MW baseline wind turbine under misaligned wind-wave and near-fault ground motions. The robustness of the mitigation performance of the 3d-PTMD under system variations is studied. Dual linear TMDs are used for comparison. Research results show that the 3d-PTMD responds more rapidly and provides better mitigation of the bi-directional response caused by misaligned wind, wave and near-fault ground motions. Under system variations, the 3d-PTMD is found to be more robust than the dual linear TMDs to overcome the detuning effect. Moreover, the 3d-PTMD with a mass ratio of 2% can mitigate the short-term fatigue damage of the offshore wind turbine tower by up to 90%.

조작자 근육 활성도 기반 양팔 로봇의 임피던스 제어 파라미터 갱신 방법 (Impedance Parameter Update Method for Dual-arm Manipulator based on Operator's Muscle Activation)

  • 백찬렬;차광열;김준식;최영진
    • 로봇학회논문지
    • /
    • 제17권3호
    • /
    • pp.347-352
    • /
    • 2022
  • The paper presents how to update impedance control parameters for dual-arm manipulators using EMG signals and motions of the operator. Since the hand motions of the dual-arm are modeled to be the mass-spring-damper system in this paper, the impedance parameter update method is an important issue to reflect the operator's force. However, task space inertia to be used as the mass parameter goes to infinity if the manipulator approaches a kinematic singularity. To alleviate this issue, the impedance (stiffness and damping) parameters are divided with a diagonal element of the task space inertia. Also, the stiffness and damping matrices are updated using the normalized EMG signals captured from the operator's forearm. Through this process, the motion of the dual-arm manipulator is more stabilized even though it approaches the kinematic singularity.

디젤엔진을 탑재한 짚차량의 2분할 플라이휠에 관한 연구 (A study on dual mass flywheel for a jeep vehicle with Diesel Engine)

  • 정종안;조찬기
    • 한국안전학회지
    • /
    • 제12권3호
    • /
    • pp.17-22
    • /
    • 1997
  • This paper reals with the structure and function of duel mass flywheel. Damping effects of engine rotational fluctuation are compared with those of pre-damper clutch and duel mass flywheel and driven- system behavior is estimated engine idle r.p.m. The reason of gear rattle noise is higher in summer than winter and driving longer period than initial driving is due to affection by drag torque changing. The above-contents can be used on the design of clutch system and transmission matching including engine and duel mass flywheel.

  • PDF

고주파 영차홀드의 샘플링 주기와 물리적 댐퍼가 안정적인 햅틱 상호작용에 미치는 영향 (Effect of the sampling time of high-frequency ZOH and a physical damper on stable haptic interaction)

  • 이경노
    • 한국산학기술학회논문지
    • /
    • 제20권2호
    • /
    • pp.649-654
    • /
    • 2019
  • 가상 환경과의 안정적인 상호작용은 사용자의 안전을 위해서 뿐만 아니라 사용자의 몰입감 향상을 위해서도 반드시 필요하다. 특히 현실감 높은 가상 강체 모델을 구현하기 위해서는 가상 강체 모델인 가상 스프링 상수를 가능한 크게 설계해야 한다. 그러나 가상 스프링 상수를 크게 하면 시스템이 불안정해지므로, 가상 스프링 상수의 크기에는 제한이 있다. 단일샘플링 주기를 이용하는 기존 방법보다 가상 스프링의 안정성 영역을 크게 하기 위해서 제안된 방법이 고주파 영차홀드를 포함한 햅틱 시스템 모델이다. 본 논문에서는 고주파 영차홀드의 샘플링 주기, 햅틱 장치의 물리적 댐퍼 크기와 안정적인 가상 스프링 최댓값과의 관계를 시뮬레이션을 통해 분석한다. 물리적 댐퍼 크기가 커질수록, 고주파 영차홀드의 샘플링 주기가 짧아질수록 가상 스프링의 안정성 영역은 커진다. 그리고 제시된 방법에서 비율 N이 40보다 커지면 물리적 댐퍼크기에 따라 안정성 영역을 기존 방법보다 약 3배~8배 더 크게 만들 수 있다. 따라서 본 방법이 가상환경 속 사용자의 현실감 향상에 도움이 될 것이다.

자연환기 벤틸레이터의 댐퍼 형태별 환기량 조절능력 평가 (Evaluation of Airflow Control Capability of Natural Ventilators with Various Dampers)

  • 김태형;하현철;박승철
    • 한국산업보건학회지
    • /
    • 제16권4호
    • /
    • pp.364-374
    • /
    • 2006
  • Natural ventilation technique could be the substitute for or the complement to the local exhaust ventilation system in the sense of protecting work environment. Moreover, it has many strong points ; almost no mechanical parts, no energy use and no noise. If applied appropriately, it could have the very high ventilation rate and save a lot of energy expense. But, it depends on the outdoor environment, especially temperature and wind speed/direction. Predicting the capacity of natural ventilation is not an easy job because it comes from both buoyancy and wind effect. Another problem is too much flow through the ventilator especially in winter time due to too much difference between indoor and outdoor temperature. Thus some ventilators in industries are sealed by door or plastic sheet, resulting in bad work environment. Various types of dampers are used to control the flow rate through ventilators. The capabilities of flow control by damper has not been estimated. In addition, it was not tested whether the damper could obstruct the flow through ventilator when fully opened. To answer these questions, 4 types of dampers were tested by using computational fluid dynamics. 10 different configurations includes no damper, full open and half open. Flow rates were estimated and airflow fields were analysed to clarify the before-mentioned questions. The dual type damper was the best choice for controling the capability of ventilator. In addition, the upward grill type damper was the best for not obstructing the air flow when fully opened.

The effect of mainshock-aftershock on the residual displacement of buildings equipped with cylindrical frictional damper

  • Mirtaheri, Masoud;Amini, Mehrshad;Rad, Moosa Doosti
    • Earthquakes and Structures
    • /
    • 제12권5호
    • /
    • pp.515-527
    • /
    • 2017
  • Recently, Friction dampers become popular due to the desirable performance in the energy dissipation of lateral loads. A lot of research which has been conducted on these dampers results in developing friction dampers with low sensitivity to the number of cycles and temperature increases. Friction dampers impose high residual drifts to the buildings because of low post-yield stiffness of the damper which results from increasing lateral displacement and period of buildings. This issue can be more critical under strong aftershocks which results in increasing of structural damages. In this paper, in addition to the assessment of aftershock on steel buildings equipped with friction dampers, methods for controlling residual drifts and decreasing the costs of retrofitting are investigated. Utilizing rigid connections as a lateral dual system and activating lateral stiffness of gravity columns by adding elastic braces are as an example of effective methods investigated in this research. The results of nonlinear time history analyses on the low to medium rise steel frames equipped with friction dampers illustrate a rise in residual drifts as the result of aftershocks. In addition, the results show that different slip loads of friction damper can affect the residual drifts. Furthermore, elastic stories in comparison to rigid connections can reduce residual drifts of buildings in an effective fashion, when most slip loads of friction dampers are considered.