• 제목/요약/키워드: Dual Current Control

검색결과 210건 처리시간 0.023초

Dual PI 제어기를 이용한 IPMSM 드라이브의 고성능 제어 (High Performance Control of IPMSM Drive using Dual PI Controller)

  • 고재섭;최정식;김도연;정병진;정동화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.105-110
    • /
    • 2008
  • This Paper proposes Dual-PI controller for high performance control of IPMSM drive. Input of traditional PI control used speed error, but Dual-PI controller used two input speed error, current error and output is output is f-axis current. Dual-PI controller is Possible both speed control and current control because it used speed error and current error Therefore, dual-PI controller can is reduced current ripple. This paper is made analysis performance of algorithm and proposes result.

  • PDF

상간리액터 없는 병렬연결 듀얼컨버터 시스템의 동작해석과 새로운 전류제어 (Operation Analysis and New Current Control of Parallel Connected Dual Converter System without Interphase Reactors)

  • 지준근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권7호
    • /
    • pp.488-493
    • /
    • 2000
  • In this paper, a predictive current control of 12-pulse parallel connected dual converter system without interphase reactors(IPR) is presented. Firstly, the characteristics of system without IPR are analyzed and compared with that of system with IPR. And the predictive current control of this system is discussed. Finally the validity of the presented system and the excellence of the predictive current control response is proved through the simulation results and experimental results.

  • PDF

12펄스 병렬 연결 듀얼 컨버터 시스템의 예측전류제어 (Predictive Current Control of 12-Pulse Parallel Connected Dual Converter System)

  • 이창원;송인호;최창호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.405-408
    • /
    • 1998
  • In this paper, a predictive current control of 12-pulse parallel connected dual converter system with interphase transfromer(IPT) is presented. Firstly, 12-pulse parallel connected dual converter system and the predictive current control of this system is discussed. And the validity of the presented system and the excellence of the predictive current control response is proved through the simyulation and experiment result.

  • PDF

Current Sensorless MPPT Control Method for Dual-Mode PV Module-Type Interleaved Flyback Inverters

  • Lee, June-Hee;Lee, June-Seok;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.54-64
    • /
    • 2015
  • This paper presents a current sensorless maximum power point tracking (MPPT) control method for dual-mode photovoltaic (PV) module-type interleaved flyback inverters (ILFIs). This system, called the MIC (Module Integrated Converter), has been recently studied in small PV power generation systems. Because the MIC is an inverter connected to one or two PV arrays, the power system is not affected by problems with other inverters. However, since the each PV array requires an inverter, there is a disadvantage that the initial installation cost is increased. To overcome this disadvantage, this paper uses a flyback inverter topology. A flyback inverter topology has an advantage in terms of cost because it uses fewer parts than the other transformer inverter topologies. The MPPT control method is essential in PV power generation systems. For the MPPT control method, expensive dc voltage and current sensors are used in the MIC system. In this paper, a MPPT control method without current sensor where the input current is calculated by a simple equation is proposed. This paper also deals with dual-mode control. Simulations and experiments are carried out to verify the performance and effectiveness of the proposed current sensorless MPPT control method on a 110 [W] prototype.

Stability Analysis and Improvement of the Capacitor Current Active Damping of the LCL Filters in Grid-Connected Applications

  • Xu, Jinming;Xie, Shaojun;Zhang, Binfeng
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1565-1577
    • /
    • 2016
  • For grid-connected LCL-filtered inverters, dual-loop current control with an inner-loop active damping (AD) based on capacitor current feedback is generally used for the sake of current quality. However, existing studies on capacitor current feedback AD with a control delay do not reveal the mathematical relation among the dual-loop stability, capacitor current feedback factor, delay time and LCL parameters. The robustness was not investigated through mathematical derivations. Thus, this paper aims to provide a systematic study of dual-loop current control in a digitally-controlled inverter. At first, the stable region of the inner-loop AD is derived. Then, the dual-loop stability and robustness are analyzed by mathematical derivations when the inner-loop AD is stable and unstable. Robust design principles for the inner-loop AD feedback factor and the outer-loop current controller are derived. Most importantly, ensuring the stability of the inner-loop AD is critical for achieving high robustness against a large grid impedance. Then, several improved approaches are proposed and synthesized. The limitations and benefits of all of the approaches are identified to help engineers apply capacitor current feedback AD in practice.

Dual Converter 정류회로의 입력 역율 제어 (Input Power Factor Control of Dual Converter Rectifier)

  • 이규종;성세진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.385-387
    • /
    • 1988
  • Dual converter is being used as a four-quadrant source for the controlled rectifier. But the rectifier itself and circulating current between P and N-converter contribute to generate reactive power. The methodology of input power factor control of dual converter by means of circulating current control is presented in this paper.

  • PDF

분산 전원 시스템의 전력품질 향상을 위한 계통연계 인버터의 이중 전류제어 기법 (Dual Current Control Scheme of a Grid-connected Inverter for Power Quality Improvement in Distributed Generation Systems)

  • 김경화
    • 조명전기설비학회논문지
    • /
    • 제29권9호
    • /
    • pp.33-41
    • /
    • 2015
  • To improve the power quality of distributed generation (DG) systems even in the presence of distorted grid condition, dual current control scheme of a grid-connected inverter is proposed. The proposed current control scheme is achieved by decomposing the inverter state equations into the fundamental and harmonic components. The derived models are employed to design dual current controllers. The conventional PI decoupling current controller is used in the fundamental model to control the main power flow in DG systems. At the same time, the predictive control is applied in the harmonic model to suppress undesired harmonic currents to zero quickly. To decompose the voltage inputs and state variables into the fundamental and harmonic components, the fourth order band pass filter (BPF) is designed in the discrete-time domain for a digital implementation. For experimental verification, 2kVA prototype of a grid-connected inverter has been constructed using digital signal processor (DSP) TMS320F28335. The effectiveness of the proposed strategy is demonstrated through comparative simulation and experimental results.

Dual Converter에 의한 DC MOTOR의 새로운 전류제어 (A New Current Control of DC Motor using Dual Converter)

  • 지준근;설승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.564-567
    • /
    • 1991
  • In this paper a predictive current control strategy is adopted in the D.C motor drive using dual converter. It is a kind of feedforward control working without overshoot within very short settling time. The difference to the well-known PI current control lies in considering the computer's ability of pre-calcurating the converter's behavior. By simulation it is shown that the predictive current control solve the problems of optimal PI current control, such as overshoot and settling time.

  • PDF

High-Reliability Three-Phase Dual-Buck Grid-Connected Inverter without Shoot-Through Problem

  • Fu, Zhenbin;Feng, Zhihua;Chen, Xi;Zheng, Xinxin
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.454-462
    • /
    • 2019
  • When compared to traditional bridge-type inverters, the dual-buck inverter has a higher reliability due to the fact that its bridge legs do not have a shoot-through problem. In this paper, the working principle of the dual-buck inverter is analyzed. A comparison of the working modes under full-cycle and half-cycle control is discussed. With half-cycle control, the inverter can realize a higher efficiency. However, this results in current zero-crossing distortion. The corresponding control strategy of the dual-buck inverter is proposed in order to realize both high efficiency and low current harmonic distortion. In addition, the system stability is analyzed. Dead-time is unnecessary due to the advantages of the topology. Thus, the current harmonic distortion can be further reduced. An inverter with the proposed control strategy has the advantages of high reliability, high efficiency and low current harmonic distortion. Finally, simulation and experimental results are given to verify the theoretical analysis.

순환 전류를 이용한 병렬 연결된 사이리스터 듀얼 컨버터의 불균형 병렬 운전 보상 기법에 관한 연구 (A Study on the Compensation Method for Unbalance Parallel Operation of Parallel Connected Thyristor Dual Converters using Circulating Current)

  • 김성안;한성우;문동옥;김영우;이창희;조윤현
    • 전력전자학회논문지
    • /
    • 제21권6호
    • /
    • pp.473-480
    • /
    • 2016
  • This study proposes a performance improvement for parallel-connected thyristor dual converters using a circulating current with an unbalanced parallel operation compensator. The proposed control method determines a variable reference value for the voltage PI controller according to voltage error at firing angle control applied to a difference current control. This method uses circulating current control to maintain a stable voltage and excellent current response during parallel operation. The effectiveness of the proposed control is verified with a simulation and an experiment based on the comparison of the performance of the proposed control method with other conventional methods.