• Title/Summary/Keyword: Dry heat

Search Result 919, Processing Time 0.033 seconds

Investigation of Coke Formation in Dry Methane Reforming over Nickel-based Monolithic Catalysts

  • Pornruangsakun, Pongsakorn;Tungkamani, Sabaithip;Ratana, Tanakorn;Phongaksorn, Monrudee;Sornchamni, Thana
    • International Journal of Advanced Culture Technology
    • /
    • v.3 no.1
    • /
    • pp.31-38
    • /
    • 2015
  • Coking accumulations via dry methane reforming (DMR) over 10NAM monolithic catalyst and pelletized catalyst was investigated. 10NAM catalyst was synthesized and coated on a wall of monolithic reactor. Pelletized catalyst of 10NAM was also prepared for the comparison. Consequently, catalyst was characterized by BET, $H_2-TPR$ and $H_2-TPD$. The catalytic reaction was undergone at $600^{\circ}C$ under atmospheric pressure and $CH_4$ to $CO_2$ reactant ratio of 1:2. The coking formation over spent catalyst was then carried out in the hydrogen flow using temperature programmed technique (TPH). According to the results, DMR over 10NAM monolithic catalyst exhibits a minimized coking formation comparing to the use of pelletized catalyst. This could be attributed to a prominent heat transfer efficiency of the monolithic catalyst.

CFD Analysis of Natural Convection Flow Characteristics of Various Gases in the Spent Fuel Dry Storage System

  • Shin, Doyoung;Jeong, Uiju;Jeun, Gyoodong;Kim, Sung Joong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.4
    • /
    • pp.19-28
    • /
    • 2016
  • Objective of this study is to compare the inherent characteristics of natural convection flow inside the canister of spent fuel dry storage system with different backfill gases by utilizing computational fluid dynamics (CFD) code. Four working fluids were selected for comparison study. Helium currently used backfill gas for canister, air, nitrogen, and argon are frequently used as coolant in many heat transfer applications. The results indicate that helium has very distinct conductive behavior and show very weak natural convective flow compared to the others. Argon showed the strongest natural convective flow but also the worst coolability. Air and nitrogen showed similar characteristics to each other. However, due to difference in Prandtl number, nitrogen showed more effective natural convective flow. These results suggest that experimental validation for the nitrogen is needed to investigate the potential coolability other than currently commercially used helium.

A Comparison of Dry Deposition Velocity of Ozone to Aerodynamic Resistance Parameterization (공기역학적 저항 모수화에 따른 오존의 건성침적속도 비교)

  • 이화운;문난경;노순아
    • Journal of Environmental Science International
    • /
    • v.11 no.7
    • /
    • pp.663-667
    • /
    • 2002
  • The aerodynamic resistance($R_a$) to vertical transfer in the surface boundary layer can be formulated in terms of the friction velocity, height of observation, vertical heat flux and surface roughness. Unlike previous studies which focused on the role of $R_c$, present study perform additional tests using a variety of $R_a$ formulae. Several $R_a$ formulations available in the literature, suitable for unstable conditions, were tested for their influence on the dry deposition velocity. The canopy resistance($R_c$) determines the shape of the diurnal pattern, while a small amplitude diurnal cycle in $V_d$ was attributed to the aerodynamic resistance. The aerodynamic resistance is the major contributor to the formation of spikes in nighttime and $R_a$ is relatively important at night because the canopy resistance is smaller. All formulations show similar diurnal cycle and yield good agreement with the observations. Although present $V_d$ formulations are suitable for numerical air qualify models, the research must continue for further improvements in resistance parametrizations.

Evaluation of Ice Adhesion Strength on the Oxidation of Transmission Line ACSR Cable (송전선로 ACSR 케이블의 산화에 따른 결빙 특성 평가)

  • Cho, Hui Jae;Kim, You Sub;Jung, Yong Chan;Lee, Soo Yeol
    • Korean Journal of Materials Research
    • /
    • v.29 no.6
    • /
    • pp.378-384
    • /
    • 2019
  • Ice accumulation on Aluminum Conductor Steel Reinforced(ACSR) cable during winter is an important matter in terms of safety, economy, and efficient power supply. In this work, the ice adhesion strengths of ACSR cable oxidized during different periods(7 years oxidized and 15 years oxidized) are evaluated. At first, a plate type dry oxidation standard specimen, whose surface characteristics are similar to those of ACSR cable, is prepared. Dry oxidation standard specimens are heat-treated at $500^{\circ}C$ for 20, 60, and 120 minutes in order to obtain different degrees of oxidation. After the dry oxidation, surface properties are analyzed using contact angle analyzer, atomic force microscopy, spectrophotometer, and gloss meter. The ice adhesion strengths are measured using an ice pull-off tester. Correlations between the surface properties and the ice adhesion strength are obtained through a regression analysis indicating a Boltzmann equation. It is revealed that the ice adhesion strength of 15-year oxidized ACSR cable is approximately 8 times higher than that of ACSR-bare.

Comparative Study of Corrosion Resistance of Organic Coating and Dry Coating on 304 Stainless Steels Used for Bipolar Plates in Polymer Electrolyte Membrane Fuel Cells (고분자전해질 연료전지 분리판용 304 스테인리스 강재의 유기습식 및 건식코팅에 따른 내식성 비교연구)

  • Yong Hyeon Kim;Jin Sung Park;Sung Jin Kim
    • Corrosion Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.242-251
    • /
    • 2023
  • The electrochemical corrosion behaviors of 304 stainless steels (STSs) with various coatings (organic coating and dry coating) were examined, and their applicability as bipolar plates in polymer electrolyte membrane fuel cells (PEMFCs) was validated. The results showed that the organic-coated samples had a significant decrease in anodic and cathodic current density compared to the uncoated sample. However, an increase in carbon black content in the organic coating or additional heat treatment at 700 ℃ resulted in a decrease in corrosion resistance. In addition, improvements in corrosion resistance achieved by adding TiO2 powder to the organic coating were found to be limited. In contrast, dry coating with TiC and CrC exhibited higher corrosion potential, significantly lower current density, and reduced contact resistance compared to the organic coatings. Notably, the TiC-coated sample showed a comparatively lower current density and more stable behavior than the CrC-coated sample. Based on a series of experimental results, a thin TiC coating without defects is proposed as a promising surface treatment strategy for STS bipolar plates in PEMFC.

A Numerical Model for Plastic Shrinkage Cracking of Concrete Slab (콘크리트 슬래브의 소성수축균열 해석모델)

  • Kwak Hyo-Gyoung;Ha Soo-Jun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.448-455
    • /
    • 2005
  • In this paper, an analytical model for estimation of the time at which the concrete surface begins to dry is introduced to predict whether or not plastic shrinkage cracks occur. First of all, the validity of a consolidation model for bleeding of cement paste proposed by Tan et al. is verified by comparing the analytical results with the experimental results, and used to evaluate the rate and amount of bleed water of concrete. Also an analytical model for evaporation of bleed water which considers the effect of the temperature variation of concrete surface due to hydration heat on the evaporation rate is proposed, and the experimental and analytical results are then compared to verify the validity of the introduced model. In advance, the time at which the concrete surface begins to dry is estimated using above two analytical models, and compared with the experimental results about the time at which plastic shrinkage cracks occur. From the comparison, it is verified that the proposed model can predict the occurrence of plastic shrinkage cracking with comparative precision.

  • PDF

Numerical Simulation for Local Circulation of Urban Area and Deposition Phenomenon (도시지역의 국지순환과 침적현상에 관한 수치모의)

  • 이화운;오은주;노순아;반수진
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.6
    • /
    • pp.773-787
    • /
    • 2003
  • There are variations in the temperature Held due to urban heat island and anthropogenic heating so that regional scale meteorological field is changed. Therefore we simulate and predict the regional climate change according to surface characteristics through regional meteorological model. This study investigates the regional meteorological field by urbanization that influences in local circulation system using CSU-RAMS and simulates dry deposition velocity (V$_{d}$) using PNU/DEM which includes surface characteristics (such as albedo, surface hydrology and rough-ness length etc.) with calculated meteorological field. During the summer, horizontal distributions of V$_{d}$ were simulated using CSU-RAMS and PNU/DEM at Busan metropolitan area. The estimated values of V$_{d}$ were larger in forest and agricultural areas than water areas since ozone with low water solubility is destroyed slowly at wet surface or water.water.

Effects of Freeze Dry Control Parameters on the Sublimation Drying Time of Garlic paste (동결건조 제어변수가 마늘의 승화건조시간에 미치는 영향)

  • Park, N.H.;Bae, S.C.
    • Journal of Biosystems Engineering
    • /
    • v.18 no.2
    • /
    • pp.122-132
    • /
    • 1993
  • Effects of physical properties of garlic paste and freeze dry control parameters on the sublimation drying time were investigated to verify optimal operating method in freeze drying. A mathematical model of freeze drying by sublimation was suggested and used to estimate the drying time of garlic paste. Under various conditions, the drying time of garlic paste was calculated using the computer program for the suggested model. Among the physical properties of garlic paste, melting temperature was evaluated the most important factor in affecting the drying time. In supplying methods of the required heat energy for sublimation, it would be the best way to control the upper plate temperature and the lower plate temperature independently.

  • PDF

A Study on the Syndrome of Soseunggitang(小承氣湯證) in Sanghanlon(傷寒論) (『상한론(傷寒論)』 소승기탕증(小承氣湯證)에 대한 연구(硏究))

  • Bang, Jung-Kyun
    • Journal of Korean Medical classics
    • /
    • v.27 no.1
    • /
    • pp.57-65
    • /
    • 2014
  • Objective : The syndrome of daeseunggitang(大承氣湯證) and the syndrome of soseunggitang(小承氣湯證) are different from pathogenesis of the dry stool(燥屎). Due to the lack of body fluid the syndrome of soseunggitang(小承氣湯證)'s dry stool occurs. However, Soseunggitang(小承氣湯) does not have the appropriate remedy. So I will propose a suitable remedy and I suggest it will be available for disease. Method : Study on the syndrome of soseunggitang in Sanghanlon(傷寒論). Result : The syndrome of soseunggitang and Soseunggitang are not corresponded with each other. The treatment of promoting production of body fluid to relax bowels is necessary for the syndrome of Soseunggitang. Conclusion : Through the analysis, I have the following conclusions. Jeungaegseunggitang(增液承氣湯) is more suitable for the syndrome of soseunggitang. Soseunggitang is suitable for disease accompanied by interior heat and dampness.

A Study on the Characteristics of Environmental Factors of Granite Dome Models with Different Material during Winter Season

  • Kong, Sung-Hoon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.1
    • /
    • pp.71-76
    • /
    • 2001
  • Factors governing the rate of heat exchange comprise temperature, air velocity, relative humidity, and relation indoors. Recently, there are many researches on the transient analysis of indoor environmental factors such as dry bulb temperature, relative humidity and air velocity in miniature models. The purpose of this study is to measure the environmental factors and to analyze and evaluate the characteristics of indoor environment in different envelop structures using granite dome models. The interior relative humidity is constant regardless of exterior humidity although a little range of variation is shown in comparison to the cement model.

  • PDF