• Title/Summary/Keyword: Dry heat

Search Result 919, Processing Time 0.022 seconds

A Numerical Study on the Performance Analysis of Plume Abatement Cooling Tower with Dry Type Heat Exchanger (건식 열교환기를 이용한 백연방지 냉각탑 성능의 수치해석적 연구)

  • 김병조;최영기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.1018-1027
    • /
    • 2003
  • This study treats the analysis of the performance and the design of plume abatement wet/dry cooling tower with dry type heat exchanger using a numerical method. A two-dimensional analysis is performed using the finite volume method for mechanical draft counterflow and crossflow tower. For a coupling problem between water and air system, a turbulent two phase flow is considered. Effectiveness-NTU method is used for modeling of the dry type heat exchanger. The parameter change simulations of the outer wall shape, the relative flowrate of air, and attachment of an air mixer are performed to examine the effect on plume abatement. It is found that if the relative air flowrate ratio and the adequate air mixer type are chosen well in addition to the ratio of water to air flowrate, the loss of the cooling capacity and the additional cost are reduced and the plume is abated.

Numerical Study on the Performance Analysis of Plume Abatement Cooling Tower with Dry Type Heat Exchanger

  • Kim, Byung-Jo;Choi, Young-Ki
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.2
    • /
    • pp.61-70
    • /
    • 2005
  • This study treats the numerical analysis of performance and design for plume abatement wet/dry cooling tower with a dry type heat exchanger. A two-dimensional analysis is performed using the finite volume method for mechanical draft counterflow and crossflow tower. For a coupling problem between water and air system, a turbulent two phase flow is considered. The Effectiveness-NTU method is used for modeling of the dry type heat exchanger. The parametric simulations such as the relative flowrate of air and attachment length of an air mixer are performed to examine the effect on plume abatement. It is found that if the relative air flowrate ratio and the adequate air mixer type are chosen well in addition to the ratio of water to air flowrate, the loss of cooling capacity and the additional cost are reduced and the plume is abated.

A Case Study of a Taeeumin Patient with Advanced Parkinson's Disease Diagnosed as Dry-heat Symptomatic Pattern (태음인(太陰人) 조열증(燥熱證)으로 진단한 진행된 파킨슨병 환자 치험례)

  • Lee, Mi-Suk;Park, Yu-Gyeong;Bae, Na-Young
    • Journal of Sasang Constitutional Medicine
    • /
    • v.25 no.4
    • /
    • pp.442-453
    • /
    • 2013
  • Objectives This case study was about a Taeeumin patient with advanced Parkinson's disease diagnosed as Dry-heat symptomatic pattern. In this study, we reported significant improvement of motor and non-motor symptoms of this patient after Sasang constitutional medicine treatment. Methods The patient was diagnosed with Taeeumin Dry-heat symptomatic pattern and treated with Taeeumin's constitutional medications and acupuncture. The primary outcome measure for this study is Unified Parkinson Disease Rating Scale(UPDRS) to assess the overall function of patient. Secondary outcome assessments include Global Assessment Scale(GAS), change of patient's sleep, stool and urine. Results and Conclusions The patient treated with Taeeumin's constitutional medications and acupuncture had reduction in UPDRS (specifically Part II, Part III and Part IV) and GAS of motor symptoms. Furthermore, patient's sleep, stool and urine were reported to be normal after treatment. In conclusion, this study shows that Sasang constitutional medicine can be effective treatment for Taeeumin patient with Advanced Parkinson's disease diagnosed as Dry-heat symptomatic pattern.

Comparative Study on Performance of Wet-type and Dry-type Floor Heating Systems Using Geothermal Heat Pump (지열히트펌프를 이용한 습식.건식 바닥난방 성능평가 연구)

  • Lee, Byoung-Doo;Lee, Se-Jin;Lee, Dae-Woo;Oh, Sung-Hae;Nam, Woo-Dong
    • New & Renewable Energy
    • /
    • v.5 no.4
    • /
    • pp.60-65
    • /
    • 2009
  • The present study was conducted for a comparative evaluation of wet and dry floor heating systems using geothermal heat pump. We circulated hot water from geothermal heat pump which is $10{\sim}15^{\circ}C$ lower than that from boiler. In order to access indoor temperature ($25^{\circ}C$) it took 74 minutes for dry type and 247 minutes for wet type. Average floor temperature was $23.9^{\circ}C$ for wet type and $32.7^{\circ}C$ for dry type. Energy saving rate gradually increased by 66% after 138 minutes. As a result, in case of floor heating system using low temperature circulation water, dry type was more practicable for stable floor heating than wet type in terms of floor temperature and access time to indoor set temperature.

  • PDF

A Case Study of a Taeeumin Patient with Parkinson's Disease Diagnosed as Dry-heat Symptomatic Pattern (태음인 조열증으로 진단한 파킨슨병 환자의 치험 1례)

  • Kim, So-Hyoung;Choi, Eun-Ju;Bae, Na-Young
    • Journal of Sasang Constitutional Medicine
    • /
    • v.29 no.4
    • /
    • pp.376-386
    • /
    • 2017
  • Objectives This case study is about a Taeeumin patient with Parkinson's disease identified as Dry-heat (Joyeol) pattern. In this study, we report significant improvement of motor and non-motor symptoms of this patient after Sasang constitutional medicine treatment. Methods The patient was identified as Taeeumin Dry-heat pattern and treated with Cheongsimyeonja-tang and acupuncture. The Unified Parkinson Disease Rating Scale(UPDRS) was used to assess the overall function of the patient. And the Global Assessment Scale (GAS) was used to assess the change of bradykinesia, tremor and dry mouth after the treatment. Results The UPDRS total score decreased from 145 points to 77 points after 5 weeks treatment. And symptoms of bradykinesia, tremor and dry mouth showed significant improvement in GAS after the treatment. Furthermore, constipation, sleep disturbance, dysuresia and anorexia were reported to be improved after treatment. Conclusions This study shows that Sasang constitutional medicine can be effective treatment for motor and non-motor symptoms caused by Parkinson's disease.

An Experimental Study of the Airside Performance of Slit Fin-and-Tube Heat Exchangers under Dry and Wet Conditions

  • Chang, Keun-Sun;Long, Phan-Than
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.1
    • /
    • pp.7-14
    • /
    • 2009
  • Water condensate accumulated on the surface of a fin-and-tube heat exchanger significantly affects its thermal and hydraulic performances. The purpose of this study is to investigate the effects of condensate retention on the air-side heat transfer performance and flow friction for various flow and geometric conditions. Total of twelve samples of slit and plate fin-and-tube heat exchangers are tested under dry and wet conditions. The thermal fluid measurements are made using a psychrometric calorimeter. Frontal air velocity varies in the range from 0.7 m/s to 1.5 m/s. Using the experimental data, presented are heat transfer coefficients in terms of Colburn j-factors and friction factors, and these data are compared with the existing correlations.

An Experimental Study on the Heat Transfer Characteristics of Two-phase closed Thermosyphon (밀폐형 2상 열사이폰의 열전달 특성에 관한 실험적 연구)

  • Cho, Ki-Hyun;Paek, Yee;Chung, Hyung-Kil
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.3
    • /
    • pp.165-171
    • /
    • 2002
  • The thermosyphon has been used as a heat transmission device in the heat recovery of low level energy and cooling for heat generating equipments. Many studies on the working fluids and wicks have been reported to improve the heat transfer efficiency of the thermosyphon. A low temperature heat pipe with acetone is chosen in the present study to compare the heat transfer characteristics due to pouring amount of working fluid, magnitude of power supplied and tilt angles. The thermosyphon made ⵁ$15.88{\times}0.8t{\times}600mm$ of copper, evaporation section 200mm, insulation section 25mm, condensation 375mm. Heat transfer rate of the thermosyphon increase as magnitude of power supplied increase and observe dry out phenomenon at 5~10% of pouring amount of working fluid. So thermosyphon at the 150kJ/s judged to need 12% or more. Heat transfer rate of the thermosyphon have nothing to do with tilt angles. Dry out phenomenon of the thermo syphon makes it possible that a low temperature thermosyphon may be used to control temperature and heat transfer of a system when the critical quantity of a working fluid is supplied in the thermosyphon.

  • PDF

Study on Pathology of Taeeumin Medicinal Herb in Sasang Constitutional Medicine (태음인 약재의 사상의학적 병리 연구)

  • Ryu, Seung-Yeob;Choi, Na-Rae;Oh, Seung-Yun;Gwak, Si-Ra;Cui, Zhenyang;Joo, Jong-Cheon;Park, Soo-Jung
    • Journal of Sasang Constitutional Medicine
    • /
    • v.30 no.2
    • /
    • pp.1-7
    • /
    • 2018
  • Objective This study was designed to define the efficacy of medicinal herbs of Taeeumin in Sasang constitutional medicine. Method We searched and analyzed original text such as Donguisusebowon Sinchuk edition written in 1901, Donguisusebowon Gabo edition written in 1894, Donguisusebowon Sansang Chobongwon, and posthumous manuscripts left by Je-ma Lee published by the Ministry of Health of North Korea. Results Seven herbs such as Ephedrae Herba, Coicis Semen, Castaneae Semen, Fel Ursi, Mori Cortex Radicis, Ginkgonis Semen, and Farfarae Flos regulate the mechanism of Esophagus-Cold (Wiwanhan). Three herbs such as Melonis Pedicellus, Ailanthi Radicis Cortex, and Quisqualis Fructus regulate the mechanism of Cold Lung-Dry (HanpaeJo). Sixteen herbs such as Rhei Rhizoma, Angelicae Tenuissimae Radix, Puerariae Radix, Cimicifugae Rhizoma, Angelicae Dahuricae Radix, Moschus, Gleditsiae Spina, Mume Fructus, Aurum, Glycine Semen Germinatum, Ampelopsis Radix, Cornu rhinocerotis, Antelopis Cornu, Bomeolum, Bezoar Bovis, and Typhae Pollen regulate the mechanism of Liver-Heat (Ganyeol). Three herbs such as Chrysanthemi Indici Flos, Nelumbinis Semen, and Spirodelae Herba regulate the mechanism of Heat Lung-Dry (YeolpaeJo). Conclusion Forty four herbs of Taeeumin regulate the mechanisms of Esophagus-Cold (Wiwanhan), Cold Lung-Dry (HanpaeJo), Liver-Heat (Ganyeol), Heat Lung-Dry (YeolpaeJo) and correct the energy-fluid pathology of Taeeumin.

The Study of Performance Evaluation Coefficient of Fin-and-Tube Heat Exchangers with Frosting (착상을 수반한 핀-관 열교환기의 성능평가계수에 관한 연구)

  • 최봉준;황준현;신종민
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.132-136
    • /
    • 2003
  • For the study of performance evaluation on different shape heat exchangers that have the same energy consumption in a refrigerator, we make performance evaluation coefficient (PEC) which can distinguish performance of different shape heat exchangers. The results were reported in order to compare with for the dry frosting and wet frosting test as various definition of PECs. Results showed that PEC of dry frosting test is higher than that of wet frosting test because attached water droplet increases pressure drop of air-side then this decreases performance of heat exchanger.

Nutritional Retention Factor of 1+ Quality Grade Hanwoo Beef Using Different Cooking Methods (1+등급 한우의 부위별 조리방법에 따른 영양소 잔존율)

  • Kim, Hong-Gyun;Lee, Kun-Jong;Kim, Sung-Min;Chung, Hea-Jung
    • Food Science of Animal Resources
    • /
    • v.30 no.6
    • /
    • pp.1024-1030
    • /
    • 2010
  • The focus of the study was to maximize the output data for Korean cuisine. This study evaluated the nutritional retention factor for different cuts of Korean beef (Hanwoo beef) subjected to various cooking methods. Five cuts (short rib, sirloin, chuck roll, tenderloin, and fore shank) of Korean Hanwoo beef were prepared and used in this experiment. Two different cooking methods (dry-heat cooking and moisture-heat cooking) were applied to each cut. The sodium contents of dry-heat cooked short rib (86.44), sirloin (76.81), tenderloin (86.65), and fore shank (85.89) decreased. Potassium contents of dryheat cooked sirloin (94.99), chuck roll (89.19), and fore shank (92.66) decreased. Calcium contents of dry-heat cooked sirloin (61.49), chuck roll (73.97), and fore shank (91.46) decreased. Iron contents of dry-heat cooked chuck roll (79.71), and tenderloin (90.79) decreased. Phosphorus contents of dry-heat cooked sirloin (87.87), and tenderloin (99.88) decreased. Mineral contents of all cuts cooked by moisture-heat decreased. Finally, the nutritional retention factor represents output data of each cooking method with yield % of each item.