• Title/Summary/Keyword: Dry eyes

Search Result 86, Processing Time 0.035 seconds

The Effect of Artificial Tear Components on Tear Film Stability of Dry Eyes in the Early Stage of Soft Contact Lenses Wear (소프트콘택트렌즈를 착용한 건성안의 착용초기 눈물막 안정성에 인공눈물 성분 조성이 미치는 영향)

  • Kim, So Ra;Lim, Jung A;Jung, Ji Hye;Byun, Hyun Young;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.191-201
    • /
    • 2016
  • Purpose: In the present study, the effect of artificial tears with different ingredients on tear film stability and subjective symptoms of dry eyes in the early stage of soft contact lenses wear was investigated. Methods: The three kinds of artificial tears and saline solution were respectively applied onto 50 dry eyes which wore soft contact lenses made of etafilcon A. Then, non-invasive tear film break-up time (NIBUT) was measured at every five minutes for 30 minutes right after the instillation of artificial tears, and the changes in blink rate and subjective symptoms were estimated after 30 minutes from the instillations. Results: All three kinds of artificial tears increased NIBUT larger than saline. The effect of increasing NIBUT immediately after the instillation of artificial tears was the largest when the artificial tear containing viscosity enhancer was used. The duration time of the effect was the longest when the artificial tear having both surfactant and viscosity enhancer was applied. The blink rate was not significantly changed when both artificial tears and saline solution were instilled. Subjective symptoms were significantly improved by the instillation of both artificial tears and saline solution and dryness, irritation, tiredness, stiffness, dazzling were improved by the use of most solutions. However, the subjective symptoms were rebounded to the level before the instillation of artificial tears after 30 minute-instillation. Conclusions: It was revealed that both artificial tears and saline solution could improve the subjective symptoms of dry eye in the early stage of soft contac lenses however, the effect of these solutions on the tear film stability was different according to the components. From the results, it is suggested that the proper selection of artificial tears is necessary for the improvement of dry eye symptoms at the early stage of soft contact lenses wear in dry eye.

Real-time Notification System of Webcam Monitor for Preventing Computer Vision Syndrome (컴퓨터시각증후군 예방을 위한 웹캠모니터의 실시간알림 시스템)

  • Ha, Sangwon;Yoo, Dohyeob;Moon, Mikyeong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.754-755
    • /
    • 2015
  • Computer Vision Syndrome(CVS) is a temporary condition resulting from focusing the eyes on a computer display for protracted, uninterrupted periods of time. To prevent CVS, you have to blink your eyes frequently, also have to keep distances from monitor. In this paper, real-time notification system for preventing CVS by checking user's distance between eyes and monitor and user's frequency of nictation in real time through monitor webcam is described.

  • PDF

A comparative study of contact lens wearer with dry-eye patient on tear function tests (콘텐트렌즈 착용자와 건성안 환자의 눈물 검사에 대한 비교 연구)

  • Kim, Soon-Ae;Seo, Eun-Sun;Lee, Young-Hwan;Kim, Ja-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.301-312
    • /
    • 2004
  • This study was performed to compare the relationship between contact lens wearer and dry-eye patient. In this study, TBUT, SIT, TTT, Rose bengal staining and McMonnies dry eye symptom questionnaire were performed as a baseline. With the base data, the subjects were classified to 3 groups : 3S patients who have dry eye signs and symptoms, 38 patients who are wearing soft contact tenses, 35 subjects who have health eyes and never worn on a contact lenses as control subjects. Contact lens wearers were divided into 3 groups according to the duration of contact lens wear. There were no significant differences in TBUT, STT, TTT, Rose-bengal staining and McMonnies dry eye symptom questionnaire result between contact lens wearer group and dry eye patients group. We suggest that there are similarities in tear function tests between the dry-eye patient and the contact lens wearer.

  • PDF

Fitting of Soft Contact Lenses (소프트 콘택트 렌즈의 피팅)

  • Lee, Eun-Hee;Kim, Dae-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.173-180
    • /
    • 2000
  • To determine the effect of base curve and diameter of soft contact lenses on the fitting under the various corneal curvature, the model eyes which was made of either stainless steel or ordinary wood, were used as the substitutes for human eyes. The evaluations of fit of the soft contact lenses on both wood model eyes and human eyes were found to be very similar to each other. All the contact lenses except very thin ones became flat after fit on the stainless steel model eyes because the model eye could not preserve enough moisture to hold the edge of contact lenses on the steel ball's surface. The relationships between the base curves of contact lenses and radii of cornea for the optimum (normal) fit were measured as follows : corneal curvature (C.C)<7.6 mm : base curve(B.C) 8.4 mm, C.C 7.6~7.8 mm : B.C 8.4~8.5 mm. C.C 7.8~8.1 mm : B.C 8.6 mm. It is concluded that larger base curve is required for the eyes which have abnormal bulge on its cornea. It is found that very thin soft contact lenses can be easily twisted or folded regardless of moisture content when they were fit on the relatively dry eyes(corneas).

  • PDF

Review on the Jaeumkangwha-tang in Hyungsang Medicine (자음항화탕의 형상의학적 고찰)

  • Jung Heung Shik;Kang Kyung Hwa;Lee Yong Tae
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.18 no.4
    • /
    • pp.982-989
    • /
    • 2004
  • The following is the conclusion drawn from a review on the clinical cases cured by Jaeumkangwha-tang in perspective of Hyungsang medicine. Jaeumkangwha-tang originated from the modified Jibaiksamul-tang in 'Manbyunghuichun(萬病回春)' and applied to the diseases induced by flaming fire due to deficiency of Yin. In 'Donguibogam', there are two kinds of Jaeumkangwha-tang. One in the chapter of kidney is mainly prescribed to replenish the Jung of kidney and applicable to the cases with configuration and symptom of kidney along with fire. The other one in the chapter of fire is applied to the symptoms of flaming fire due to deficiency of Yin. The characteristics of the patients treated by Jaeumkangwha-tang from the viewpoint of Hyungsang medicine can be classified as follows : ① configuration: Dam type, Shin type, inverted triangular type(:天垂象), bird type, round eyes, thin lips, slender waist, thin leg, pretty face, sparkling eyes, prominent upper lip and upward eyes and nose. ② color : dark red complexion, red cheek bone, red lips and red glabella. ③ pulse : fine and fast pulse and pulsation on the Chuk(尺) in man and so forth. ④ symptoms: agility, talkativeness, pimpled face, crooked back, weakness to the heat of summer, light eating, timidity, blood-shot eyes, night sweat, cough, abundant phlegm, hemoptysis, bloody spittle, enervation, emaciation, back pain, flaccidity of lower limbs, involuntary emission, nocturnal emission, heat sensation in the chest palms and soles, anger, flush on cheek bone, red lips and dry mouth, reddish tongue, stiff excrement, scanty yellow urine, etc.

The Comparative Analysis for the Progression of Dry Eyes Caused by Wearing Soft Contact Lenses(SCL) and Cosmetic Soft Contact Lenses(C-SCL) (소프트 콘택트렌즈와 미용 콘택트렌즈의 건성안 진행에 대한 비교분석)

  • Kim, Myoung-Jin;Hwang, Hye-Kyung;Jang, Woo-Yeong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.375-381
    • /
    • 2011
  • Purpose: The purpose of this research was to see how wearing either a SCL or a C-SCL effected the dryness of a person's eye depending on how long they wear either type of lens. Methods: This study was carried out on 52 subjects (104 eyes) who were all in their twenties and had previously experienced wearing contact lenses. All of these subjects were required to wear either a SCL or a C-SCL, which were made out of the same material, for three months. Contents such as the McMonnies Questionnaire survey, the blinking rate per min. and the Noninvasive tear break-up time test (NIBUT) were later conducted on the subjects for this study. Results: According to the results of the McMonnies Questionnaire, it was concluded that the longer the subject wore the SCL and C-SCL, the value of the measurements gradually increased. On the other hand, the results from the NIBUT concluded that the longer the subject wore the SCL, the value of the measurements eventually decreased. However, according to the measurements of the blink rate test, it was concluded that neither results had a significant change. Conclusions: It was concluded that long-term wearing of SCL and C-SCL could be the cause of the induction and progression of dry eyes.

The Effects of Auricular Acupressure Therapy on Middle-aged and Old Adults' Dry Eye Syndrome (이압요법이 중·노년의 안구건조증에 미치는 효과)

  • Choi, Yun-Joo;Hwang, Sun-Kyung;Kim, Sang-Sik
    • Journal of East-West Nursing Research
    • /
    • v.26 no.1
    • /
    • pp.17-27
    • /
    • 2020
  • Purpose: This study aimed to examine the effect of auricular acupressure therapy on reducing the ocular symptoms and signs for dry eye syndrome. Methods: The participants who were aged ≥ 40 years old and met the inclusion criteria of the ocular surface disease index score ≥ 13 and a tear film break-up time ≤ 10 seconds were enrolled into the two groups: experimental group (n=29) and control group (n=27). Experimental group received auricular acupressure therapy for 8 weeks. Seed stickers were applied to the eye, liver and tubercle point of each ear once a week. Data were collected at pre and 4 and 8 weeks after the treatment and analysed the efficacy of intervention by repeated measures ANOVA. Results: There were significant differences in the ocular surface disease index, standard patient evaluation of eye dryness and a tear film break-up time in both eyes at 8 weeks after the treatment between the two groups. Conclusion: The findings indicate that the auricular acupressure therapy may be helpful for relieving symptoms of dry eye as a nursing intervention. In addition, it could also be utilized as a self-care practice using proper education and training.

Study to the Effect of Involutional Blepharoptosis Surgery Using Objective and Subjective Parameters

  • Asamura, Shinichi;Wada, Yoshitaka;Tanaka, Saiichi;Saika, Shizuya
    • Archives of Plastic Surgery
    • /
    • v.49 no.4
    • /
    • pp.473-478
    • /
    • 2022
  • Background We investigate the effect of involutional blepharoptosis (IB) surgery based on dry eye symptoms by analysis using objective and subjective measures. Methods We recorded various parameters from patients that underwent levator advancement surgery for IB, totaling 125 eyes (total 65 patients, 5 unilateral, 60 bilateral). Subjective assessment comprised a questionnaire on dry eye-related quality of life score (DEQS), a summary score calculated from DEQS, and six-grade evaluation, the patient's own measure of eye comfort. Objective assessment comprised marginal-reflex distance-1 (MRD-1), measurement of tear film breakup time, and superficial keratopathy (SPK) existence by slit lamp microscope. Results Subjective assessments showed that IB patients had improvement of dry eye symptoms and eye comfort when surgery increased MRD-1. On the other hand, objective assessments showed that the presence of SPK is suspected when the postoperative MRD-1 level is 3 mm or higher. Conclusion IB surgery must not only increase MRD-1 value, but also to perform maintenance of the appropriate ocular surface condition. From our parameters, we suggest postoperative MRD-1 value should be maintained at < 3 mm to safe and effective of IB surgery.

Influence of Cellular Phone Videos and Games on Dry Eye Syndrome in University Students (스마트폰의 동영상과 게임 사용이 대학생의 안구건조에 미치는 영향)

  • Park, Jeong Sook;Choi, Mi Jung;Ma, Ji Eun;Moon, Ji Hyun;Moon, Hyo Jeong
    • Research in Community and Public Health Nursing
    • /
    • v.25 no.1
    • /
    • pp.12-23
    • /
    • 2014
  • Purpose: The purpose of this study is to investigate influence of cellular phone videos and games on dry eye syndrome in university students. Methods: A randomized comparison group pre-post design is used. Sixty university students were randomly assigned to either a video or a game group. Frequencies of blinking, dry eye symptoms scores and amounts of tears were measured. Thirty subjects watched cellular phone video programmes and the other 30 subjects played cellular phone games for 61 minutes. In addition, frequencies of blinking were measured three times during treatment, once immediately after a treatment and twice at an interval of 20 minutes after subsequent treatments. Results: Post-test scores of frequencies of blinking significantly decreased, dry eye symptoms scores including amounts of tears significantly increased greater than pre-test scores in both groups. But there were no significant differences between the groups. Frequencies of blinking were significantly different with respect to the time spent using cellular phone. In both groups, the lowest frequencies of blinking were shown after 40 minutes of cellular phone use. Conclusion: This study shows that using cellular phone has negative influence on dry eye syndrome and eyes require a resting period after cellular phone use over 40 minutes.

Technical Note: Development of Wireless Electrooculorgraphy System to Measure Vestibuloocular Reflex (단신: 전정 반사 분석을 위한 안구 움직임 무선 측정 장치 개발)

  • Park, Yang-Sun;Kim, Hyung-Sik;Yi, Jeong-Han;Lim, Young-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.1
    • /
    • pp.39-43
    • /
    • 2008
  • The purpose of this study was to develop EOG system for collecting eye movement patterns to investigate visual function and position and the level of balancing. This small and partable wireless EOG system was enabled to collect stable signals without hindering any kind of sports movement. This system was consist of four parts: amplifier, main process with wireless transmitter, receiver, and display. Three EOG electrodes were used and placed on right(+), left(-) sides of eyes, and between eyes as a reference. This system was possible to measure signals for relatively long duration but the degeneration of electrodes may magnify measurement errors when collecting time was getting longer. Thus, dry electrodes may be applied to the system when long term measurement is needed for future studies.