• Title/Summary/Keyword: Dry eyes

Search Result 86, Processing Time 0.033 seconds

Thermographic Assessment in Dry Eye Syndrome, Compared with Normal Eyes by Using Thermography (열화상카메라를 이용한 정상안과 건성안의 서모그래피 비교)

  • Park, Chang Won;Lee, Ok Jin;Lee, Seung Won
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.247-253
    • /
    • 2015
  • Purpose: The purpose of this study was to compare and analyze the ocular surface and the palpebral conjunctiva of categorized subjects, which were divided into normal eye group and dry eye group, by using a thermal camera. Methods: Subjects were 144 eyes of 72 normal university students, who didn't have any corneal disease, abnormal lacrimal ducts, medical records regarding ocular surgeries, or experience of using contact lens. Subjects were divided into two groups, which were normal eye group and dry eye group, based on the results of TBUT, Schirmer I test, and McMonnies test. After categorizing the subjects, the temperature of the subjects' ocular surface and the palpebral conjunctiva were measured and analyzed by using a thermal camera (Cox CX series, Answer co., Korea). Results: In the normal eye group's Central Ar.1, Nasal Ar.2, Temporal Ar.3, Superior Ar.4, Inferior Ar.5, the measured amount of temperature change on each area was $-0.13{\pm}0.08$, $-0.14{\pm}0.08$, $-0.12{\pm}0.08$, $-0.14{\pm}0.08$, $-0.10{\pm}0.09(^{\circ}C/sec)$. The dry eye group's results were $-0.17{\pm}0.08$, $-0.16{\pm}0.07$, $-0.16{\pm}0.08$, $-0.17{\pm}0.09$, $-0.15{\pm}0.08(^{\circ}C/sec)$. When compared with the normal eye group, the values of Ar.1, Ar.3, Ar.5 were significantly different in the dry eye group(p<0.05). The amount of temperature change, which was observed on the palpebral conjunctiva(Ar.1:central, Ar.2: nasal, Ar.3: temporal) of the normal eyes, measured by thermography, was $34.36{\pm}1.12$, $34.17{\pm}1.10$, $34.07{\pm}1.12^{\circ}C$ on each area. Same values taken from the dry eye group was $33.55{\pm}0.94$, $33.43{\pm}0.97$, $33.51{\pm}1.06^{\circ}C$ on each area. The values of Ar.1, taken from the dry eye group, had a significant difference, compared to the values of the normal eye group(p=0.05). Conclusion: The temperature of the ocular surface decreased faster on the dry eyes, compared to the normal eyes. The temperature measured on the palpebral conjunctiva of the dry eyes were also lower than the normal eyes. The temperature changes on the ocular surface, observed with a thermal camera, were objective values to assess the stability of tear films, and might provide useful data for studies related to dry eye syndrome.

The Difference in Tear Film Stability between Normal and Dry Eyes by Wearing Clear and Circle Contact Lenses made of the Same Materials (동일 재질의 투명 및 써클콘택트렌즈 착용 시 정상안과 건성안의 눈물막 안정성 차이)

  • Lee, Sehee;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.11-21
    • /
    • 2016
  • Purpose: The aim of this study was to analyze the difference in tear film stability according to the wearing time when wearing clear and circle soft contact lens(circle lens) made of same material. Methods: The clear and circle contact lenses of hilafilcon B and nelfilcon A materials were respectively applied on the subjects classified as normal and dry eyes depending on their tear volume, and their tear film stability was investigated by measuring the non-invasive tear film break-up times, lens centration and the first appearing area of tear breakup after 30 mins and 6 hrs of lens wearing. Results: Non-invasive tear film breakup time significantly reduced with increase of the wearing time for normal and dry eyes when wearing clear and circle contact lenses. The starting ratio of tear film break-up was higher at the peripheral area of clear and circle lenses in all two different materials, and higher at the peripheral area of dry eyes than normal eyes. Starting ratio of tear film break-up was higher at the peripheral area of nelfilcon A lenses compared with hilafilcon B lenses, however, its change with the increase of wearing time showed a different aspect. The number of tear film break-up per unit area when wearing circle lenses of nelfilcon A increased at the central area with the wearing time while its number was higher at the peripheral area when wearing circle lenses of hilafilcon B. The centration of clear lenses made of two materials was closer to pupil compared to circle lenses with the increase of wearing time, however, a larger decentration was shown in dry eyes compared with normal eyes. Conclusions: The research revealed that an effect on tear film stability may be changed by clear lenses as well as circle lenses with coloring process according to the increase of wearing time, and the factors affecting on tear film stability may also vary depending on lens materials. Thus, the appropriate lenses should be selected by the consideration of lens material as well as coloring method/dyes according to the wearers' habit such as daily wearing time and wearing period when trying to wear clear and circle lenses.

Associated factors of self-reported dry mouth in adults (일부 성인의 주관적 구강건조증에 영향을 미치는 요인)

  • Kim, Sun-Sook;Youn, Hye-Jeong
    • Journal of Korean society of Dental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.55-62
    • /
    • 2015
  • Objectives: The purpose of this study was to investigate the associated factors of self-reported dry mouth in adults. Methods: A self-reported questionnaire was filled out by 249 adults in Seoul and Gyeonggi-do from June to October, 2014. The questionnaire consisted of general characteristics of the subjects, age, monthly income, smoking, alcohol drinking, and systemic diseases including systemic diseases, medication, oral health status, and stress. The question for dry mouth consisted of dryness in skin, eyes, lips, and nasal mucosa. The subjective dry mouth consisted of 6 questions measured by visual analogue scale(VAS). Cronbach's alpha was 0.881 in the study. Oral health related quality of life (OHIP-14) was adapted from Yoon. The questionnaire for OHIP-14 included functional limitation, physical pain, psychological disability, social disability, and experience in hadicap measured by Likert 5 scale. Cronbach's alpha was 0.885 in the study. Data was analyzed for a t-test, one-way ANOVA and multiple regression analysis by using SPSS(SPSS 18.0, USA) program. Results: There were positive correlations between oral health-related quality of life and self-reported dry mouth (functional limitation r=0.288, physical pain r=0.219, psychological discomfort r=0.193, physical disability r=0.280, psychological disability r=0.205, social disability r=0.224 and handicap r=0.270). In the multiple regression analysis, variation of self-reported dry mouth were positively associated with dry eyes{very often(${\beta}=0.305$)), sometimes(${\beta}=0.186$)}, dryness on lips{very often(${\beta}=0.247$), sometimes(${\beta}=0.177$)}, handicap(${\beta}=0.152$), physical disability(${\beta}=0.128$) and alcohol drinking(1-2 times/week)(${\beta}=0.116$) (p<0.001). Conclusions: Self-reported dry mouth may cause deterioration of the entire body dryness(dryness on eyes and lips), low oral health-related quality of life(handicap and physical disability) and alcohol drinking. Thus, It is necessary to develop oral health education programs to prevent and manage dry mouth in adults.

Association of serum 25-hydroxyvitamin D concentrations with Schirmer tear test 1 and tear film breakup time in dogs

  • Youngsam Kim;Seonmi Kang;Kangmoon Seo
    • Journal of Veterinary Science
    • /
    • v.24 no.2
    • /
    • pp.32.1-32.10
    • /
    • 2023
  • Background: The association between vitamin D and canine keratoconjunctivitis sicca (KCS) has not been investigated in dogs. Objectives: To investigate the association of serum 25-hydroxyvitamin D [25(OH)D] concentrations with Schirmer tear test 1 (STT-1) and tear film breakup time (TFBUT) in dogs. Methods: Sixty-one clinically healthy, client-owned dogs were enrolled. STT-1 and TFBUT were measured in 122 (61dogs) and 82 (41 dogs out of total 61 dogs) eyes, respectively. Serum 25(OH)D concentrations were evaluated by quantitative chemiluminescent immunoassay. The dogs were classified into 6 groups according to the evaluations (STT-1: group 1, normal [≥ 15 mm/min] in both eyes; group 2, normal in one eye and abnormal [< 15 mm/min] in the fellow eye; group 3, abnormal in both eyes; TFBUT: group 4, normal [≥ 20 sec] in both eyes; group 5, normal in one eye and abnormal [< 20 sec] in the fellow eye; group 6, abnormal in both eyes). Results: STT-1 was positively correlated with TFBUT (p < 0.001). Among the STT-1 groups, the mean serum 25(OH)D concentration in group 1 was significantly higher than in groups 2 and 3 with positive correlation (p < 0.001). However, there were no significant differences among the TFBUT groups 4, 5, and 6. Conclusions: In dogs, it was found that serum 25(OH)D concentrations had a greater effect on quantitative KCS than qualitative KCS. Therefore, it is considered that measurement of serum 25(OH)D concentration could be included in the diagnostic tests in canine quantitative KCS patients.

Change in Axial Rotation of Toric Soft Contact Lens according to Tear Volume (눈물양에 따른 토릭 소프트콘택트렌즈의 축 회전양 변화)

  • Seo, Woo Hyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.445-454
    • /
    • 2015
  • Purpose: The present study was aimed to investigate the effect of tear volume on a change of axial rotation according to wearing time of toric soft contact lens and gaze directions. Method: Toric soft contact lenses with double thin zone design applied on 62 eyes. Then, changes in non invasive tear film break-up time and the rotational direction/amount of lens when changing gaze direction were respectively measured after 15 minutes and 6 hours of lens wear. Results: Lens rotation to temporal direction was more found when changing gaze direction after lens wear. However, its rotation was varied according to wearing time and the subjects' tear volume. Furthermore, the frequency of lens rotation to temporal direction was higher in dry eyes compared with normal eyes at nearly all gaze directions after 15 minutes and 6 hour of lens wear. The rotational amount of lens was generally greater in dry eyes after 15 minutes of lens wear. However, its difference between normal eyes and dry eyes was not great after 6 hours of lens wear. Conclusion: The present study revealed that axial rotation of toric soft contact lens was varied according to the wearer's tear volume and lens rotational patterns at the initial, and extending periods of lens wear were different. The change in rotational pattern of toric soft contact lens from these results means the possibility of visual change after extending lens wear, and the identification of its correlation with tear volume suggests the necessity of considering factors for choosing appropriate toric soft contact lens.

Effects of Humidity Changes on Eyes (습도 변화가 눈에 미치는 영향)

  • Sun-Hee Han;Bong-Hwan Kim;So-Bin Kim;Min-Jung Kim;Hee-Kyung Park;Hyun-Ji Kim;Heon-Tae Kim;Hyeong-Su Kim
    • Journal of Korean Clinical Health Science
    • /
    • v.11 no.1
    • /
    • pp.1616-1624
    • /
    • 2023
  • Purpose. The purpose of this study was to investigate the effect of changes in tear break-up time, accommodative response amount, and accommodative microwave on the eyes due to changes in humidity. Methods. A total of 48 adult men and women in their 20s (21.1±1.56 years old) were surveyed on dry eye questionnaires (OSID questionnaires), tear destruction time was measured by humidity (40%, 60%, 80%), and controlled reactions and controlled fine waves were measured through tactile tests. Result. As a result of the OSID questionnaire, there were 10 normal patients, 8 mild dry eyes, 1 moderate dry eye, and 5 severe dry eyes. The initial tear film destruction time was 7.34±4.67 seconds at 40% humidity, 8.99±4.75 seconds at 60% humidity, 10.26±4.52 seconds at 80% humidity, and the average tear film destruction time was 9.51±4.07 seconds at 40% humidity, 10.99±3.82 seconds at 60% humidity, and 12.05±3.42 seconds at 80% humidity. The accommodative response was -0.41~1.79D at 40% humidity, -0.34~1.79D at 60% humidity, and -0.30~2.01D at 80% humidity. The accommodative microwave was measured as 56.39~63.43dB when it was 40%, 56.41~62.64dB when it was 60%, and 55.96 ~61.13dB when it was 80%. Conclusion. As the humidity (40~80%) increased, the tear break-up time increased, and as the accommodative stimulus amount increased, the accommodative response amount increased. It was found that the accommodative microwave according to the amount of accommodative stimulation increased, and as the humidity increased, the accommodative microwave decreased.

The stability of tear film for Korean (한국인에 대한 누액 안정성 조사)

  • Lee, Seong-Wook;Sim, Hyun-Seog;Jang, Seong-Joo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.161-164
    • /
    • 2001
  • The purpose of our study was stability of tear film for Korean. In the 1970s, the major problem for the contact lens practitioner was the management of contact lens parameters. In the 1980s, oxygen permeability was the main problem in contact lens practice: now it is dry eyes. To appropriately fit the patient with contact lenses it is imperative to know in advance if the patient has a marginal dry eye. Based on the initial diagnosis appropriate care can be taken to minimize problems with the result that the patient can successfully wear contact lenses. A well known test for dry eyes is Schirmer test which has shown to be useful for diagnosing Sjogren syndrome. Biomicroscopy can often unmask numerous problems. The classical test for marginal dry eye is measuring the tear break up time(TBUT). A dry eye problem with contact lenses is often caused by the lid. If an incomplete blink is responsible for the dry eye it is possible to change the situation by blinking exercises. The result of these test, mean value of age was 22.8, mean value of blink rate was 19 times/min, mean value of Schirmer test was 25 mm/5 min, mean value of TBUT was 7.1 sec.

  • PDF

Comparison of Blinking Patterns When Watching Ultra-high Definition Television: Normal versus Dry Eyes (초고선명 텔레비전 시청 시 정상안과 건성안에서의 눈깜박임 양상 비교)

  • Kang, Byeong Soo;Seo, Min Won;Yang, Hee Kyung;Seo, Jong Mo;Lee, Sanghoon;Hwang, Jeong-Min
    • Journal of The Korean Ophthalmological Society
    • /
    • v.58 no.6
    • /
    • pp.706-711
    • /
    • 2017
  • Purpose: To analyze blinking patterns when watching an ultra-high definition (UHD) television and to compare the results between normal eyes and dry eyes. Methods: A total of 59 participants aged from 13 to 69 years were instructed to watch a colorful and dynamic video on a UHD television for 10 minutes. Before and after watching the UHD television, we measured the best corrected visual acuities, autorefraction, tear-break-up-time, degree of corneal erosion and conjunctival hyperemia via slit lamp biomicroscopy. In addition, questionnaires for the evaluation of eye fatigue and symptoms of a dry eye were completed. The definition of dry eye syndrome was that the tear-break-up-time of one of the eyes was less than 5 seconds, conjunctival injection, or marked corneal erosion. The number of blinks and the duration of blinking were both measured and analyzed at the early and late phases of video-watching. Results: After watching the UHD television in the normal eye group, the tear-break-up-time was significantly decreased (p < 0.001) and the degree of corneal erosion was significantly increased (p = 0.023). However, the subjective symptoms of participants were not aggravated (p = 0.080). There were no significant differences in blinking patterns in the dry eye group. On the other hand, in the normal eye group, the mean blinking time was significantly increased (p = 0.030). Conclusions: Watching an UHD television changes the tear-break-up-time, degree of corneal erosion, and blinking pattern in normal eyes, which may increase the risk of dry eye syndrome.

A Study on the Confidence of Dry Eye Diagnosis Methods (건성안 검사 방법의 신뢰도에 대한 연구)

  • Lee, Byeong Jun;Hong, Jae Hyeon;Jung, Dai;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.15-20
    • /
    • 2008
  • Purpose: To study on the confidence of dry eye diagnosis methods which need to prescribe contact lens. Methods: Non-invasive tear film break-up time (NIBUT) and tear film break-up time (TBUT) were measured in forty healthy subjects in their 20s, and then the subjects were classified into normal eye and dry eye. The results of McMonnies questionnaire, tear prism height measurement, Hardtack test, blink rate measurement and Schirmer test were compared with the results of NIBUT and TBUT. Results: The results of NIBUT and TBUT were as follows; 20 subjects had normal eyes, 10 subjects had dry eyes in both NIBUT and TBUT, and 10 subjects showed different results. In McMonnies questionnaire, the score of normal eye group averaged 8.2 and that of dry eye group averaged 18.5, which showed statistically significant difference. Furthermore, 100% of normal eye group classified by the results of NIBUT and TBUT corresponded with the result of McMonnies questionnaire and 90% of dry eye group showed the correspondence. Tear prism height of normal eye group averaged 0.32 mm and that of dry eye group averaged 0.23 mm, which were significantly different. Hardtack test, blink rate measurement and Schirmer test without local anesthesia showed no statistically significant difference between normal eye group and dry eye group. Conclusions: On dry eye diagnosis methods, the results of McMonnies questionnaire and tear prism height measurement had close correlation with the results of NIBUT and TBUT.

  • PDF

Effects of Acupuncture Therapy on Dry Eye Syndrome: 43 Case Series (안구건조증 환자 43례의 침치료 효과에 대한 임상적 연구)

  • Lee, Chang-Woo;Lee, Eun-Kyoung;Jeon, Ju-Hyun;Kim, Jung-Ho;Kim, Young-Il;Kim, Jung-Il
    • Journal of Acupuncture Research
    • /
    • v.27 no.6
    • /
    • pp.85-94
    • /
    • 2010
  • Objectives : The aim of this study was to evaluate the effect of acupuncture therapy on dry eye syndrome. Methods : We investigated 43 cases of patients with dry eye syndrome. They were treated with acupuncture therapy twice or three times a week. Symptoms score, number of dry eye symptoms, Ocular surface disease index were compared between eyes before and after treatment to evaluate the efficacy of acupuncture therapy. Results : After 24 times treatment, symptom score, number of dry eye symptoms, Ocular surface disease index were significantly decreased. Conclusions : Acupuncture therapy was effective to improve symptoms of dry eye syndrome patients. There should be more observation about patients with dry eye syndrome and further study will be needed.