• Title/Summary/Keyword: Dry air

Search Result 1,451, Processing Time 0.034 seconds

Depositional Characteristics of Atmospheric PCBs in Several Media Used Passive Air Samplers (대기 중 PCBs의 PAS에 이용되는 여러 매체의 PCBs 침착 특성)

  • Chun, Man-Young
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.2
    • /
    • pp.151-158
    • /
    • 2013
  • Objective: This study was carried out to determine the depositional characteristics of pine needles, pine tree bark, moss, and soil, which are used as a passive air sampler (PAS) of atmospheric polychlorinated biphenyls (PCBs). Methods: All four media were sampled from the same site. PCB concentrations were analyzed by GC/MSD, and the lipid contents were measured using the gravimetric method. Results: The total PCB concentration (IUPAC No. 28, 52, 101, 138, 153, 180) was the highest in soil (227.97 pg/g dry), followed by pine needles (71.36 pg/g dry), pine tree bark (44.58 pg/g dry), then moss (21.91 pg/g dry). Pine needles contained the highest lipid contents (21.31 mg/g dry), whereas soil (10.01 mg/g dry), pine tree bark (4.85 mg/g dry), and moss (1.92 mg/g dry) contained less. The concentration of lower-chlorinated PCBs was relatively high in pine needles, pine tree bark and moss, but not in soil. The PCB concentrations were proportional to their lipid contents in pine needles, pine tree bark and moss, but a different trend was revealed in soil. Conclusions: The PCBs concentrations in the media were affected by various factors including atmospheric PCB concentrations, lipid contents, and depositional pathways. However, each of these factors had a varying influence depending on the type of medium.

An investigation on the insulation characteristics of $SF_6$ mixtures gas under uniform and non-uniform electric field (평등/불평등 전계에서의 $SF_6$혼합된 가스의 절연파괴특성 연구)

  • Lee, Sang-Hwa;Lee, Young-Jo;Ahn, Hee-Sung;Jeong, Seung-Young;Koo, Ja-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1397-1398
    • /
    • 2007
  • 본 연구는 $SF_6$와 Dry-air(건조공기), $N_2$, $CO_2$ 가스가 혼합된 절연매체의 절연 특성과 부분방전 특성 연구를 기초실험용 쳄버와 70kV급 GIS mock up을 이용하여 교류전압을 인가하여 실험이 수행되었다. 전자의 경우, Sphere gap 및 Needle/Plate 전극시스템을 이용하여 순수 $SF_6$가스와 Dry-air, $N_2$, $CO_2$ 가스들의 절연내력을 비교하고, 챔버의 압력을 5기압으로 유지한 상태에서 Dry-air, $N_2$, $CO_2$$SF_6$가스의 혼합비를 변화시키면서 절연내력이 측정되었다. 후자의 경우, 기초실험에서 도출된 $SF_6$가스와 Dry-air, $N_2$, $CO_2$의 최적의 혼합비율을 선택한 후, 방전 개시전압과 부분방전 양상을 순수 $SF_6$가스의 결과와 비교분석하기 위한 실험을 수행하였다. 이를 위하여 GIS 사고의 주요원인이 되는 결함들, 즉 Protrusion, Floating, Free moving particle 들을 인위적으로 모의하여 Mock up 내부에 설치하고 내부 압력을 5기압으로 유지한 상태에서 수행되었다. 전자의 경우, $0.5{\sim}5$ 기압 범위 내에서 Dry-air, $N_2$, $CO_2$ 압력을 변화시켰을 때 절연내력은 전극시스템에 무관하게 순수 $SF_6$가스의 결과치의 Dir-air $47{\sim}51%$, $N_2\;48{\sim}61%$, $CO_2\;47{\sim}60%$ 정도이다. 또한 챔버 압력이 5기압인 상태에서 Dry-air, $N_2$, $CO_2$가 80% 혼합된 절연매체는 순수 $SF_6$가스 절연내력의 80%이상의 절연내력을 가지고 있다. 후자의 경우, 인가전압을 고정 시켰을 때, 부분방전 패턴과 방전크기는, 순수 $SF_6$가스와 Dry-air 가 80% 혼합된 절연매체는 동일한 패턴과 방전크기를 나타내고 있다. 이러한 결과를 근거로, 가스 압력이 5기압에서 운전되는 전력기기의 절연매체로서 혼합가스를 사용할 경우, $SF_6$가스와 Dry-air, $CO_2$, $N_2$ 가스들의 혼합비는 2:8정도가 적절한 것으로 제안한다.

  • PDF

An Experimental Study on the Effect of the Air Temperature on the Air-Side Heat-Transfer Coefficient and the Friction Factor of a Fin-and-Tube Heat Exchanger (외기 온도 변화가 핀-관 열교환기의 공기측 열전달계수와 마찰계수에 미치는 영향에 관한 실험적 연구)

  • Kim, Nae-Hyun;Cho, Honggi
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.4
    • /
    • pp.149-158
    • /
    • 2017
  • In general, the air-side j and f factors of evaporators or condensers are obtained through single-design tests performed under air-dry and wet-bulb temperatures. Considering that the indoor or outdoor air temperatures vary significantly during the operation of an air conditioner, it is necessary to confirm that the experimentally-obtained j and f factors are widely applicable under variable air conditions. In this study, a series of tests were conducted on a two-row slit-finned heat exchanger to confirm the applicability. The results showed that, for the dry-surface condition, the changes of the tube-side water temperature, water-flow rate, and air temperature had virtually no effect on the air-side j and f factors. For the wet condition, however, the f factor was significantly affected by these changes; contrarily, the j factor is relatively independent regarding this change. The formulation of the possible reasoning is in consideration of the condensation behavior underneath the tube. The wet-surface j and f factors are larger than those of the dry surface, with a larger amount for the f factor.

Calculation of Outdoor Air Fraction through Economizer Control Types during Intermediate Season

  • Hong, Goopyo;Hong, Jun;Kim, Byungseon Sean
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.13-19
    • /
    • 2016
  • Purpose: In this study, we examined outdoor air fraction using historical data of actual Air Handling Unit (AHU) in the existing building during intermediate season and analyzed optimal outdoor air fraction by control types for economizer. Method: Control types for economizer which was used in analysis are No Economizer(NE), Differential Dry-bulb Temperature(DT), Diffrential Enthalpy(DE), Differential Dry-bulb Temperature+Differential Enthalpy(DTDE), and Differential Enthalpy+Differential Dry-bulb Temperature (DEDT). In addition, the system heating and cooling load were analyzed by calculating the outdoor air fraction through existing AHU operating method and control types for economizer. Result: Optimized outdoor air fraction through control types was the lowest in March and distribution over 50% was shown in May. In case of DE control type, outdoor air fraction was the highest of other control types and the value was average 63% in May. System heating load was shown the lowest value in NE, however, system cooling load was shown 1.7 times higher than DT control type and 5 times higher than DE control type. For system heating load, DT and DTDE is similar during intermediate season. However, system cooling load was shown 3 times higher than DE and DEDT. Accordingly, it was found as the method to save cooling energy most efficiently with DE control considering enthalpy of outdoor air and return air in intermediate season.

Anatomical Characteristics and Air-dry Density of Young Trees of Teak Clones Planted in Indonesia

  • Hidayati, Fanny;Ishiguri, Futoshi;Marsoem, Sri Nugroho
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.4
    • /
    • pp.463-470
    • /
    • 2017
  • The objectives of this study are to obtain the basic knowledge of anatomical characteristics and wood properties of thinning trees of young teak (Tectona grandis L.F.) for fulfill the timber demand in Indonesia. Nine thinning trees of 5-year-old teak clone trees were used for analyzing the cell morphology and air-dry density. Vessel diameters in pore and outer pore zones were 165 and $90{\mu}m$, respectively. Mean value of fiber diameter, cell wall thickness, and fiber length in outer pore zone were $14.6{\mu}m$, $2.07{\mu}m$, and 1.04 mm, respectively. In addition, mean value of air-dry density was $0.55g/cm^3$. The measurement and values of vessel diameter, fiber diameter, cell wall thickness, fiber length and air-dry density in the experimental had lower than those in the older teak. Therefore, it could be suggested that the wood from thinning young teaks was not appropriate as construction material, but it could be used for furniture which do not need high of strength properties. Furthermore, since the measurements values of anatomical characteristics were still increasing from pith to bark, it could be suggested that 5-year-old teak clones are still in a juvenile phase. Positively significant correlations were found between air-dry density and cell wall thickness, indicating that cell wall thickness is strongly correlated with wood density of teak.

A Study of Horizontal Surface Discharge Characteristics for Dew-Point of Dry-Air and Materials of Solid Insulator in Quasi-Uniform Field (Dry Air 중의 준평등전계에서 노점과 고체절연물 재질에 따른 수평연면방전 특성 연구)

  • Kang, Byoung-Chil;Seok, Jeong-Hoo;Min, Gyeong-Jun;Bae, Sungwoo;Lee, Kwang-Sik;Park, Won-Zoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.64-69
    • /
    • 2015
  • This study investigates the Horizontal surface discharge characteristics of solid insulators by varying their materials, and the dew-point of dry-air. The methodology of this study is that a quasi-uniform field is first applied to a test chamber. Then, the chamber is filled with dry-air as an insulation gas which pressure is varied from 1 to 6atm while applying an AC voltage to the chamber. The used solid insulators are teflon, polyethlene and polyurethane. As the dew-point is lower and the pressure of dry-air is higher, the flashover voltage of all solid insulators increases more. When each characteristic of the solid insulators is compared under the same gas pressure, the flashover voltage of teflon is the highest. Then, the flashover voltage of polyethlene is higher than that of polyurethane. Moreover, it is observed that the flashover voltage increases as the horizontal distance between the electrodes of each solid insulator become larger, respectively. However, as the pressure is increased, flashover voltage of the solid insulators is saturated. Therefore, selection of cost-effective insulation is needed in order to appropriate pressure.

A Study of Surface Discharge Characteristics for Dew-Point of Dry-Air and Materials or Shapes of Solid Insulator in Quasi-Uniform Field (준평등전계에서의 Dry-Air 노점과 고체절연물 재질 및 형상에 따른 연면방전 특성 연구)

  • Min, Gyeong-Jun;Kang, Byoung-Chil;Lim, Dong-Young;Lee, Kwang-Sik;Park, Won-Zoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.6
    • /
    • pp.44-49
    • /
    • 2013
  • This study investigates the surface discharge characteristics of solid insulators by varying their materials, their shapes, and the dew-point of dry-air. The methodology of this study is that a quasi-uniform field is first applied to a test chamber. Then, the chamber is filled with dry-air as an insulation gas which pressure is varied from 1 to 6atm while applying an AC voltage to the chamber. The used solid insulators are teflon, polycarbonate, and bakelite. As the dew-point is lower and the pressure of dry-air is higher, the flashover voltage of all solid insulators increases more. When each characteristic of the solid insulators is compared under the same gas pressure, the flashover voltage of teflon is the highest. Then, the flashover voltage of polycarbonate is higher than that of bakelite. Moreover, it is observed that the flashover voltage increases as the diameter and the thickness of each solid insulator become larger and thicker, respectively. However, the thickness of the solid insulators is more critical for increasing the flashover voltage than their diameter.

A Study Vertical Surface Discharge Characteristics of the Shape Change of the Solid Insulation with the Same Creepage Distance of Dry-Air (Dry-Air 중의 동일 연면거리를 가진 고체절연물의 형상 변화에 따른 수직연면방전 특성 연구)

  • Jeon, Jong-Cheul;Choi, Byung-Ju;Bae, Sung-woo;Lee, Kwang-Sik;Park, Won-Zoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.1
    • /
    • pp.72-78
    • /
    • 2016
  • In terms of power components which use environmentally-friendly dry air that can substitute SF6, there have been studies on the electrical properties of the solid insulation "spacer" for the purpose of securing dielectric strength as they become smaller. This study laminated solid insulation to keep the creeping distance the same in the dry air and investigated vertical surface discharge characteristics by shape. The three sheets of disk-type solid insulation(Bakelite) were laminated in a manner to keep the creeping distance the same. The lamination was categorized as follows: "Type A" in which the insulations with the same disk diameter were laminated; "Type B" in which the insulations whose middle disk diameter was large were laminated; and "Type C" in which the ones whose middle disk diameter was small were laminated. For a vertical surface discharge experiment, dry air was injected into the test chamber depending on the shape of the laminated solid insulation, and chamber pressure was adjusted in a range of 0.1-0.6MPa. As volume decreased, surface discharging voltage by unit volume increased. This was because of dielectric polarization according to the structural characteristics of the shape of lamination. The highest surface discharging voltage was found in "Type C."

The Study on the Frontal Thunderstorm during Winter Time in the Korean Peninsula (우리나라 동계 전선성 뇌우에 관한 연구)

  • Kim, Jong-Seok;Park, Sang Hwan;Ham, Sook Jung;Ban, Ki-Song;Choi, Young Jean;Chang, Dong-Eon;Chung, Hyo-Sang
    • Atmosphere
    • /
    • v.16 no.4
    • /
    • pp.351-358
    • /
    • 2006
  • The structure of frontal thunderstorm in winter time is different from that of in summer time over the Korean peninsula, due to dry tongue and upward motion. The dry tongue, that is propagation of dry zone from upper level to lower level, was formed after front passage and the upward motion is intensified by the strengthened low level jet. Since this mechanism makes the structure more unstable, thunderstorm occurs at relatively low cloud top height. This study suggests a forecast guidance of winter time frontal thunderstorm that thunderstorms develop when one of the following conditions are satisfied: 1) total totals (TT) >40, 2) K index >-10, 3) mixing ratio ${\geq}$ 3.5 g/kg.

Dry Separation of PVC Film from Plastic Film Mixture by Using Air Table

  • Song, Young-Jun;Hiroki Yotsumoto;Lee, Gye-Seung
    • Resources Recycling
    • /
    • v.11 no.1
    • /
    • pp.37-42
    • /
    • 2002
  • This study was conducted in order to remove Poly vinyl chloride(PVC) from the waste plastic film mixture. The fittings of Air Table was modified to increase the separation efficiency of PVC and PE(poly ethylene). PE and PVC was successfully separated from PVC-PE film mixture with the yield of PE 90% or more and with his grade of 99% or more, using the improved Air Table. The details of the separation condition and results will be discussed in this paper. Dry separation, Waste plastic film, PVC, Air Table. The details of the separation condition and results will be discussed in this paper.