• Title/Summary/Keyword: Dry Out

Search Result 2,703, Processing Time 0.034 seconds

Phenomenological behavior of Bubbles and dry spots at CHF on a short heated wall: Pool boiling of R-113 (소형가열면에서 CHF 발생시 Bubble 및 Dry Spot의 현상학적 거동 R-113의 수조비등)

  • Chung, H.J.;Kim, B.D.;Chun, S.Y.;No, H.C.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.189-194
    • /
    • 2001
  • A simultaneous visualization of the behavior of bubbles and dry spots has been carried out for pool boiling of R-1l3 on a horizontal heater. From video imaging and image processing analysis, the formation of bubbles and dry spots occurs simultaneously, and therefore they should be considered as a synchronized concept rather than independent identities. The dry spot density is equivalent to the active site density in the region before CHF. At CHF point, large dry areas due to the coalescence of neighboring dry areas cover the heater surface.

  • PDF

Coating Effects on Grass Seeds with Chitosan Solution (Chitosan 용액에 의한 목초 종자의 피복효과)

  • 이주삼;조익환;안종호
    • Korean Journal of Organic Agriculture
    • /
    • v.6 no.1
    • /
    • pp.51-61
    • /
    • 1997
  • This experiment was carried out to investigate the growth response of 3 grasses to seed coating with chitosan solution and the attempt was made to estimate adequate seed coating concentrations of chitosan solution in each grass for the growth to be stimulated. Three species used in this experiment were orchardgrass, tall fescue and reed canarygrass. Six different seed coating concentrations of chitosan solution were applied as 0%(control), 0.01%, 0.05%, 0.1% and 1.0%, respectively. the results were obtained as follows; 1. Dry weight of tiller(WT), leaf area(LA), dry weight of leaf(LW), dry weight of stem(SW), dry weight of shoot(SHW), biological yield(BY) and C/F ratio were significantly different between species. 2. Number of tillers per plant(NT), dry weight of tiller(WT), dry weight of leaf(LW), dry weight of root(RW), dry weight of shoot(SHW), biological yield(BY) and T/R ration were significantly different between seed coating concentrations of chitosan solution. 3. The adequate seed coating concentrations of chitosan solution for the growth stimulating effect were different between species. The highest values of yield components and dry weight of plant parts were obtained at 1% in orchardgrass and tall fescue, and 0.05% in reed canarygrass, respectively. 4. Growth stimulating effect of seed coating in each species were different. The highest values were obtained in leaf area(LA), dry weight of leaf(LW), dry weight of root(RW), dry weight of shoot(SHW) and dry weight of biological yield(BY) in orchardgrass. The values of dry weight of stem(SW) and C/F ration were highest in reed canarygrass. 5. An increase in number of tillers per plant(NT), dry weight of leaf(LW), dry weight of stem(SW) and dry weight of root(RW) according to seed coating was attributed to the increase in dry weight of shoot(SHW). Among the aboved increasing factors, the dry weight of leaf(LW) was a main factor for the increase in dry weight of shoot(SHW). 6. An increase in dry weight of leaf(LW), dry weight of stem(SW) and dry weight of root(RW) according to seed coating was attributed to the increase in biological yield(BY). Both the dry weight of leaf(LW) and dry weight of root(RW) were main factors for the increase in biological yield(BY).

  • PDF

The Study on the Compaction Characteristics of Underground Structural Backfill with Reclaimed Soil (준설토를 이용한 지하구조물 뒷채움 다짐특성에 관한 연구)

  • 김영웅;박기순;손형호;김종국
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.357-364
    • /
    • 1999
  • The purpose of this study is to analysis the grain distribution and compaction characteristics of structural backfill with reclaimed soil. Five(5) reclaimed soil samples which passed #200 sieve have been used in the test. The study showed that the maximum dry density and the bearing value rate turned out to be becoming smaller when the more the quantity passed #200 sieve, the smaller the soil grain. The maximum dry density value calculated from the compaction md relative density test showed wet method > compaction method > dry method. The correlation coefficient between Rc and Dr based on the grain distribution and the compaction characteristics showed that the maximum dry density value by the wet method is little higher than the compaction method and dry method.

  • PDF

Review of Spent Nuclear Fuel Dry Storage Demonstration Programs in US (미국의 사용후핵연료 건식저장 실증연구의 과거와 현재)

  • Lee, Sanghoon;Yook, Daesik
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.2
    • /
    • pp.135-149
    • /
    • 2017
  • Demonstration programs for spent nuclear fuel dry storage have been carried out to produce important and confirmatory data to support safety of dry storage systems and integrity of spent nuclear fuel stored in dry condition. The US initiated the dry storage of spent nuclear fuel and has strict and explicit regulatory stipulations on the integrity of spent nuclear fuel in dry storage. The US has carried out several notable demonstration programs for the initiation and license extension of dry storage. At the very early stage of dry storage, the demonstration programs were focused on proof of the safety of dry storage systems and a demonstration project called the dry cask storage characterization project was performed for the license extension of low burn-up fuel dry storage. Currently, a demonstration program for the license extension of high burn-up fuel dry storage is under way and is expected to continue for at least 10 years. Korea has not yet begun the dry storage of PWR fuel and the US programs can be a good reference and can provide lessons to safely begin and operate dry storage in Korea. In this paper, past and current demonstration programs of the US are analyzed and several recommendations are provided for demonstration programs for the dry storage of spent nuclear fuel in Korea.

Pull-out Strengths of GFRP-Concrete Bond Exposed to Applied Environmental Conditions

  • Kabir, Muhammad Ikramul;Samali, Bijan;Shrestha, Rijun
    • International Journal of Concrete Structures and Materials
    • /
    • v.11 no.1
    • /
    • pp.69-84
    • /
    • 2017
  • This paper presents results of an experimental investigation on the behaviour of bond between external glass fibre reinforced polymer reinforcement and concrete exposed to three different environmental conditions, namely, temperature cycles, wet-dry cycles and outdoor environment separately for extended durations. Single shear tests (pull-out test) were conducted to investigate bond strengths (pull-out strengths) of control (unexposed) and exposed specimens. Effect of the exposure conditions on the compressive strength of concrete were also investigated separately to understand the effect of changing concrete compressive strength on the pull-out strength. Based on the comparison of experimental results of exposed specimens to control specimens in terms of bond strengths, failure modes and strain profiles, the most significant degradation of pull-out strength was observed in specimens exposed to outdoor environment, whereas temperature cycles did not cause any deterioration of strength.

A Experimental Study for Developing of the Dry Double Floors Hydronic Ondol System (건식이중바닥온돌시스템 개발을 위한 실험적 연구)

  • Kim Nan-Haeng;Sohn Jang-Yeul
    • Journal of the Korean housing association
    • /
    • v.17 no.3
    • /
    • pp.1-7
    • /
    • 2006
  • The aim of the research was to evaluate the characteristics of thermal environment and thermal comfort in the Dry Double floors Hydronic Ondol System. Physical indoor thermal environments (the floor surface temperature, the vertical temperature, etc.) and skin temperature have especially been measured. Physical features conditions, sensation, thermal comfort, humidity sensation, comfort of body were investigated for the survey. As a result, (1) During the operation of the boiler (12 hour), the average indoor temperature is appeared to be $21.6^{\circ}C$. The floor surface temperature showed peak value of $31.4{\sim}40.6^{\circ}C$ after 8hours 30minutes after the start-point of the heating. The vertical difference of temperature was turned out to be not uniform. (2) While the skin temperature showed a narrow distribution of temperature in the Dry Double floors Hydronic Ondol system. (3) The response to thermal comfort which people felt was satisfactory, and most of them felt dry during the test.

Estimation of Moisture Content for Wood by Oven Dry Method (전건법(全乾法)에 의(依)한 목재(木材)의 함수율추정(含水率推定))

  • So, Won-Tek
    • Journal of the Korean Wood Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.24-30
    • /
    • 1981
  • This experiment was carried out to determine the drying time from green to oven dry and estimate the moisture content of wood, such as red lauan (Shorea Spp.), Douglas fir (Pseudotsuga menziesii), Birch (Betula platyphylla), and oak (Quercus aliena), at various thickness, paralleled to fiber, of specimen for M.C. by oven dry method (100-105$^{\circ}C$). The results obtained are summarized as follows: 1. The drying time from green to oven dry decreases as the thickness of specimen for M.C. becomes to be thined, and that time at 10mm thickness are 14 hrs, for birch wood and 24 hrs, for oak wood. 2. The relative formulae between thickness (X) of specimen for M.C. and drying lime (Y) from 12% to oven dry are showed in Fig. 3. 3. The M.C. based on the weight of specimen for M.C. at t% can be obtained from the formula (2), and the drying time to 1% are shorter than that time to oven dry by approximately three times.

  • PDF

Comparison of Dry Matter Production in Reed canarygrass Varieties (Reed canarygrass 품종의 건물 생산성 비교)

  • 이주삼;류수훈;이경은
    • Asian Journal of Turfgrass Science
    • /
    • v.7 no.2_3
    • /
    • pp.121-127
    • /
    • 1993
  • This experiment was carried out to compare the varietal differences of dry matter production in rend canarygrass. The varieties examined were Common, Venture, Castor, Palaton and Venture. Reed canarygrass was harvested three times annually, 1st cut(1O, May), 2nd cut(31, July), and 3rd cut(10, Oct.), respectively. The results were summarized as follows ; 1. Dry matter yield were not significant difference between varieties and for the interaction of variety$\times$cut. But, there was significant difference between cuts. 2. There was not significant difference in dry matter yield between the first cut and second cut. But, the dry matter yield of the third cut was poor than the other two cuts. Thus, the average dry matter yield of varieties were 806.1 kg, 730.8kg and 495.8kg /l0a in the first, second and third cut, respectively. 3. In Venture and Palaton, the percentage of dry matter distribution in spring was higher than that of other varieties. In Common, Castor and Vantage, they were not significantly different between the percentage of dry matter distribution in each cut. Above the results suggested that the first group of varieties(Venture and Palaton) were suited to meadow and last group of varieties(Common, Castor and Vantage) were suited to pasture. 4. Average total dry matter yield of varieties was 2,032kg /l0a/yr,(ranged from 1,922kg to 2,180 kg /l0a /yr.)

  • PDF

A study on design for free cooling system using dry cooler (드라이쿨러를 적용한 외기냉수냉방 시스템 설계에 관한 연구)

  • Yoon, Jung-In;Baek, Seung-Moon;Heo, Jeong-Ho;Kim, Young-Min;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1027-1031
    • /
    • 2014
  • Free cooling system is used to reduce energy consumption of cooling system. Free cooling system is consisted of cooling group and dry-cooler in which heat exchange of chilled water and out air is conducted. Although this system has an excellent energy saving effect in place having cooling load regularly, data or material of design for free cooling system is lacked. In this study, characteristics analysis of free cooling system is conducted through software HYSYS with changing some facts. The main result is following as : Dry-cooler capacity is influenced by out air temperature, required chilled water temperature and LMTD(Logarithmic Mean Temperature Difference) of heat exchanger. As out air temperature is more low, dry-cooler capacity become increased. in addition, as required chilled water temperature is more high and LMTD is more low, the out air temperature range is widened for using dry-cooler. If out air temperature is below $0^{\circ}C$, antifreeze need to be used because freeze and burst can be occurred. In case of South Korea, antifreeze of 34% of ethylene glycol concentration is proper. When compressor load of R22, R134a and R407C is compared, considering environmental regulation and energy consumption, R134a is best working fluid.

Estimation of Cell Concentration by Light Transmitter During the Culture of Methylotrophic Yeast Pichia pastoris

  • Choi, Du-Bok;Park, Enoch Y.S.;Lee, Yong-Bo;Na, Young-Hee;Lim, Chae-Kyu
    • Mycobiology
    • /
    • v.31 no.4
    • /
    • pp.226-228
    • /
    • 2003
  • The multiple correlation coefficient between the values determined by dry weight and those determined by fluorometer was observed with r=0.96 and the standard error of calibration was 0.034. Using the best calibration data, in order to reconfirm the reliability of the fluorometer results in comparison with those obtained by dry weight on the cell concentration, fedbatch cultures were carried out. The results obtained by fluorometer measurements were in good agreement with those obtained by dry weight. The on-line monitoring of cell concentration by the fermentor system linked to a computer equipped with fluorometer was successfully carried out.