Automatic Test Method of Sizing Degree by Analysis of Liquid Penetration and its Surface Behavior (액체 침투 특성과 표면 거동 분석을 이용한 사이즈도 자동측정법)

  • Lee, Ji-Young;Kim, Gyung-Chul;Kim, Chul-Hwan;Sheikh, M.I.;Park, Hyun-Jin;Kim, Sung-Ho;Sim, Sung-Woong;Cho, Hu-Seung
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.44 no.2
    • /
    • pp.18-28
    • /
    • 2012
  • This study was to develop a novel automatic system for measuring St$\ddot{o}$ckigt sizing degree and contact angle at a time. The conventional methods to measure sizing degree had serious problems in obtaining significant differences according to different dosages of a sizing agent, and moreover they disclosed unique limitation due to liquid types used and tester's subjectivity. However, the newly developed system could get reproducible results through total automation of all procedures including liquid dropping, image acquisition and measurement of both St$\ddot{o}$ckigt sizing degree and contact angle. For the St$\ddot{o}$ckigt sizing test, the automatic system could measure sizing degree with more definite differences according to different dosage of AKD, compared to the conventional method. For the contact angle test, the automatic system showed a similar trend to the conventional method but had smaller contact angles due to distortion of an image focus by a sheet curl than the conventional testing machine. The problem from the image out of focus due to specimen curl will be overcome with adopting a new specimen holder for the future system.

Numerical Analysis of 1-D Ablation and Charring of a Composite Heat Insulator Using Finite Analytic Method (유한해석법을 이용한 조합 내열부품의 1차원 삭마 및 숯층 형성 해석)

  • 함희철;배주찬;이태호;전광민;이진호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.5
    • /
    • pp.943-951
    • /
    • 1992
  • The objectives of this study are to analyse the thermal response behavior occurring in the charring ablative material more realistically by considering ablation and char phenomena occurring in several material layers, and to increase the reliability of thermal analysis by being able to get stable solutions through using the finite analytic method. A program has been developed to predict the temperature distribution, ablation thickness, char thickness, ablation velocity and char velocity by solving non-linear one-dimensional heat conduction equation. Results of calculation were compared with results of published papers. From this compariosn this program was proved to be a very good tool for thermal design and analysis of charring ablative materials used in the rocket propulsion system.

Full Scale Tests of Concrete Filled Steel Tube Column using High Fluidity Concrete (고유동 콘크리트를 이용한 콘크리트 충전강관 기둥의 실물대 시공실험)

  • Kim Ook-Jong;Lee Do-Bum
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.222-227
    • /
    • 2001
  • Full scale construction tests of CFT(concrete filled steel tube) column to solve construction problem and to confirm quality were performed in apartment site. To improve construction efficiency, the tests has been accomplished two stages after the tests for material mixing design had been completed. In the first stage, the experimental variables were the placing methods, existence of guiding pipe, placing velocity and drop height and the height of specimen were $3.6{\cal}m$. In the second stage, Filling steel tube of 9.6m height with concrete was performed by two ways, that is, the pump-up method and the dropping method. The filled condition of the concrete and concrete strength distribution according to the column height were checked and the quality of the CFT column was confirmed.

  • PDF

A Study on the Encapsulation of Cosmetic Emulsion Using Microfluidics (Microfluidics를 이용한 화장품 에멀젼 캡슐레이션에 대한 연구)

  • Jeong, Nam-Gyun;Jin, Hong-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.81-86
    • /
    • 2021
  • The cosmetic industry is technology-intensive in the field of fine chemistry and continues to grow globally. The functional aspects have been mainly emphasized in the past to increase the market share in these cosmetics industries. Recently, however, efforts have been made to attract the attention of consumers to the visual effects as well as the excellent performance of cosmetics at home and abroad. Accordingly, cosmetic manufacturers are trying various technologies that encapsulate the cosmetic emulsion and modify the shape, color, and texture of the emulsion capsule. The basic and easiest method of encapsulating emulsion is dropping the emulsion through the nozzle from emulsion storage. On the other hand, the existing method of encapsulating emulsion has a limit in reducing the size of the capsule. In this study, the limit was shown by theory and numerical analysis method, and the emulsion encapsulation phenomena occurring in the micro-channel were studied to apply microfluidics as an alternative.

Development of the Practical Garment Apparatus to Measure Vital Sign of ECG for U-Health Care (ECG 생체신호 측정을 위한 실용적 U-헬스케어 의복개발)

  • Park, Hye-Jun;Hong, Kyung-Hi;Kim, Seung-Hwan;Shin, Seung-Shul
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.2 s.161
    • /
    • pp.292-299
    • /
    • 2007
  • Development of portable device measuring the vital sign continuously with no limit of time and space is absolutely prerequisite for the U-health care that grafts the ubiquitous concept into medical system. Accordingly, it requires to develop a garment style apparatus for measuring vital-sign that is easy to wear on for a long time period. This study suggests a method to improve the insulation of electric cable and the skin adhesion of electrode by integrating the electric conductive material to garment, in order to develop a garment apparatus for measuring ECG for U-health care. Results of the research are as follows; In order to provide the adjacent conductive yarns with insulation, braid with narrow woven end was interlaced using polyester yarn. As a result, the direct contact between electric conductive yarns was restrained, which would be interposed into pin-tuck structured cable. Washable silicone gel applied around the electrode made of electric conductive fabric improved the adhesion, which prevents electrodes from dropping off from the skin surface during body movement. ECG signals on the human subject were tested using the garment apparatus developed by the above method. And the result was that the clear QRS wave formation in the typical form of ECG could be measured in both conditions of still and moving state as well. The result of this study is expected to contribute for the production of U-health care related medical apparatus by accelerating the practical uses of the garment measuring vital sign at a reasonable price.

A study on Biodegradability of Vegetable Oil based EP Grease (식물유계 EP그리스의 생분해도 평가에 관한 연구)

  • Nam Kyung-Im;Kim Young-wun;Chung Keunwo;Cho Wonoh;Jeon In-sik;Chung Yong-Mi
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.139-148
    • /
    • 2003
  • In this study, biodegradable base Li-greases were prepared by using Li-soap thickener and vegetable oils such as soybean oil, rapeseed oil, castor oil and synthetic ester. Also, EP-greases were formulated by blending base Li-greases, anti-wear additives, EP additives, anti-oxidants and corrosion inhibitor etc. And EP-greases were characterized by analysing physical properties such as worked penetration, dropping point, 4-ball wear, extreme pressure, thermal properties etc. Biodegradability of base Li-greases and EP-greases were evaluated by CEC-L-33-A-93 method using several inoculums of domestic sewage treatment plant. As the results, biodegradability of vegetable oils were shown at the range of 97.1 to $98.4\%$. And biodegradability of base Li-greases and EP-greases were $86.2\%\;\~\;89.3\%\;and\;83.4\%\;\~\;90.0\%$ which were lower value than those o( vegetable oils due to effect of Li-soap thickener, respectively. Therefore, the EP-greases prepared in this study were easily biodegraded by microorgnism.

  • PDF

Determination of the Strength Characteristics of c-Si Solar Cells using Partially Processed Solar Cells (부분공정 태양전지를 이용한 결정질 태양전지의 강도 특성에 관한 연구)

  • Choi, Su Yeol;Lim, Jong Rok
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.5
    • /
    • pp.35-45
    • /
    • 2020
  • Photovoltaic (PV) power system prices have been steadily dropping in recent years due to their mass production and advances in relevant technology. Crystalline silicon (c-Si wafers) account for the largest share of the price of solar cells; reducing the thickness of these wafers is an essential part of increasing the price competitiveness of PV power systems. However, reducing the thickness of c-Si wafers is challenging; typically, phenomena such as bowing and cracking are encountered. While several approaches to address the bowing phenomenon of the c-Si solar cells exist, the only method to study the crack phenomenon (related to the strength of the c-Si solar cells) is the bending test method. Moreover, studies on determining the strength properties of the solar cells have focused largely on c-Si wafers, while those on the strength properties of front and rear-side electrodes and SiNx, the other components of c-Si solar cells, are scarce. In this study, we analyzed the strength characteristics of each layer of c-Si solar cells. The strength characteristics of the sawing mark direction produced during the production of c-Si wafers were also tested. Experiments were conducted using a 4bending tester for a specially manufactured c-Si solar cell. The results indicate that the back side electrode is the main component that experienced bowing, while the front electrode was the primary component regulating the strength of the c-Si solar cell.

Development of Observation Methods for Density of Stink Bugs in Soybean Field (콩포장에서 노린재류의 밀도조사법 개발)

  • Bae, Soon-Do;Kim, Hyun-Ju;Lee, Geon-Hwi;Park, Sung-Tae
    • Korean journal of applied entomology
    • /
    • v.46 no.1 s.145
    • /
    • pp.153-158
    • /
    • 2007
  • This study was conducted to develope the observing methods for density of stink bugs in soybean reproductive stage. The adults and nymphs of bean bug, Riptortus clavatus, red-banded shield bug, Piezodous hybneri, green stink bug, Nezara antennata, Sole bug, Dolycoris baccarum, and brown marmorated stink bug, Halyomorpha halys were observed by three observing methods such as beating, sweeping net, and visual counting methods in the full bloom (R2), full pod (R4) and beginning maturity (R7) of soybean. As a result, total number of stink bugs observed was the highest with 5,214.2 by beating method, and then was 2,581.8 by visual counting method, and was the lowest with 103.1 by sweeping net method. Total number of stink bugs observed by the beating and visual counting methods was P. hybneri, followed by N. antennata, H. halys, R. clavatus and D. baccarum with clear difference in observed number of each stink bugs while total number of stink bugs observed by sweeping net method was very low in the range of 18 to 23. Accordingly, the observed density of stink bugs exception of R. clavatus adult by beating method was generally high. However, the number of R. clavatus adult was more observed by flushing method than that by beating method from the beginning bloom (R1) to full maturity (R8), and was more observed at morning time than that at afternoon time. Therefore, two observation methods that flushing method for R. clavatus and beating method for the other stink bugs were recommended for the occurring density of stink bugs in soybean because both bean bug and pentatomidae stink bugs have distinct behavior characteristics such as flying and dropping.

Stability Assesment of the Slope at the Disposal Site of Waste Rock in Limestone Mine (석회석 광산에서 폐석 적치장 사면의 안정성 평가)

  • Lee, Sang-Eun;Jang, Yoon-Ho
    • Tunnel and Underground Space
    • /
    • v.20 no.6
    • /
    • pp.475-490
    • /
    • 2010
  • The analysis of slope stability was performed from seven sites among total eleven sites of waste rock which are divided into two objects (mullock-pile and rock mass) according to the location of dumping-dropping point in L limestone Mine. The analysis of circular failure using Bishop's simplified method and the finite element method for mullock-pile slopes were adopted. For rock mass slopes, identification of failure modes on stereonet projection was determined, thereby limit equilibrium analysis was applied to obtain the safety factor of slopes and the finite element method was used to understand overall behavior of slope. Phi-c reduction method was used to calculate the safety factor of slopes through the finite element method. In mullock-pile slope of zone D and rock slopes of zone F and G, the assurance of slope stability was difficult, and the plans to assure the stability of slopes were proposed on the basis of the analysis of slopes at disposal sites of waste rock. Therefore, the method of piling with waste rock by dozer pushing after dumping for mullock-pile slope of zone D is required, and the method of piling after moving to the place which has no fault zone for rock slope of zone F and G is recommended.

A Study on the Consistency Measurement of Weathered Granite Soil (화강암질풍화토(花崗岩質風化土)의 Consistency 측정(測定)에 관한 연구(硏究))

  • Kang, Yea Mook;Cho, Seung Seup;Hong, Soon Pil
    • Korean Journal of Agricultural Science
    • /
    • v.7 no.2
    • /
    • pp.109-118
    • /
    • 1980
  • This test was carried out to present criterion to measure the liquid limit of weathered granite soil by using the flow-table method whose operation is easier and more convenient than slump test. The results are as follows. 1. Since liquid limit of weathered granite soil depends upon the particle size distribution, weatheredness and content of colored minerals, maximum particle size should be prescribed when the testing rule of liquid limit by flow-table method is enacted. 2. If take the averaged water content as liquid limit where the height and width of flow are 1 cm respectively by 10 times dropping, this liquid limit is slightly less than the one by slump test. The differance of liquid limit between flow table method and slump test is about 10%. 3. Correlation curves of flow width-water content and flow hight-water content show similar shapes. Those are straight lines in semi-logarithm paper just as liquid limit test. 4. This flow-table method is more convenient and has less personal error of measurement than slump test does. So flow-table method would be favourably utilized for judging the engineering properties of soil.

  • PDF