• Title/Summary/Keyword: Drop type

Search Result 921, Processing Time 0.029 seconds

Effect of static mixer geometry on flow mixing and pressure drop in marine SCR applications

  • Park, Taewha;Sung, Yonmo;Kim, Taekyung;Lee, Inwon;Choi, Gyungmin;Kim, Duckjool
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.1
    • /
    • pp.27-38
    • /
    • 2014
  • Flow mixing and pressure drop characteristics for marine selective catalytic reduction applications were investigated numerically to develop an efficient static mixer. Two different mixers, line- and swirl-type, were considered. The effect of vane angles on the relative intensity, uniformity index, and pressure drop was investigated in a swirl-type mixer; these parameters are dramatically affected by the mixer geometry. The presence of a mixer, regardless of the mixer type, led to an improvement of approximately 20% in the mixing performance behind the mixer in comparison to not having a mixer. In particular, there was a tradeoff relationship between the uniformity and the pressure drop. Considering the mixing performance and the pressure drop, the swirl-type mixer was more suitable than the line-type mixer in this study.

Experimental Study on the Heat Transfer Characteristics in Corrugated and Flat Plate Type Heat Exchanger (콜로게이트 열교환기와 평판형 열교환기의 열전달특성에 관한 실험적 연구)

  • Park, Jung-Hun;Jeong, Yong-Ki;Jeon, Chung-Hwan;Chang, Young-June;Lim, Hyeok
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.37-42
    • /
    • 2003
  • An experiment was performed to study heat transfer characteristics between corrugated heat exchanger and flat plate type one. While heat capacity(13.86kW) was provided constantly and the flow speed was varied from 2.8 to 17.9m/s, The temperature and the pressure drop were measured. Furthermore, Heat transfer coefficient, Colburn factor and Nusselt number were calculated using them. With increase of the flow speed for both exchangers, the coefficient and the pressure drop increased, but Colburn factor decreased. The coefficient, pressure drop and Colburn factor of the corrugated type were all higher than those of the flat one, which is due to the flow interruption with recirculation and reattachment of the corrugated type. The empirical correlations of Nusselt number were suggested for the tested two heat exchangers.

  • PDF

Belt Pattern Making for Hip-hugger garment using 3D Body Scan Data (3차원 인체 스캔 데이터를 활용한 Hip-hugger 의류용 벨트 패턴 설계)

  • Park, Soon-Jee;Choi, Sin-Ae
    • Fashion & Textile Research Journal
    • /
    • v.10 no.5
    • /
    • pp.652-659
    • /
    • 2008
  • This study was designed to testify the possibility and devise the method to manipulate the 3D body scan data to produce rounded-belt pattern adaptable to hip-type variation of women in their 20's. The results of this research were as follows : Firstly, based on drop-value distribution of hip and waist girth, 151 subjects were classified into three hip-types; Type 1 (15.23%) was 'cylinder type', showing lowest drop-value, Type 2 (69.54%) was 'average type' and Type3 (15.23%) was 'hourglass type' showing highest drop-value. Secondly, using CAD program, design lines for round shape belt were set on the surface of 3D scan data of representative subject of each type. And divided 3D surfaces were flattened onto the plane by the internal tools of CAD program. The measure, 'lifting value of round belt pattern', implying the level of curve ratio of pattern was higher in back than front. This result might be linked to the fact that the hip part is more protruded than the abdomen part. And the measures also showed highest values in Type 3(hourglass type) and lowest in Type 1(cylinder type), meaning that the pattern of Type 3 showed more rounded shape than that of Type 1. This finding implied that round belt for body type having high drop-value should be shaped more curved. Thirdly, difference ratios of outline length and area between 3D curves(body surface) and 2D plane(pattern) were 4.5% and 1.3%, respectively. This result demonstrated and solidified the feasibility of designing digital garment pattern from 3D body scan data.

A Study on Heat Transfer Characteristics in the Air Side of Louvered Fin Heat Exchanger (루우버핀형 열교환기의 공기측 열전달 특성에 관한 연구)

  • Kim, Sun-Jung
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.1
    • /
    • pp.9-16
    • /
    • 2003
  • For the study of an effect that fin thickness and shape of heat exchanger have on the elevation of heat transfer efficiency, we make models of plate fin type heat exchanger and louvered fin type heat exchanger which was given a transformation of fin thickness in plate f)n type heat exchanger and louvered fin type heat exchanger which are often used now. And the effect of fin thickness on pressure drop and characteristics of heat transfer was experimented and analysed when air velocity and temperature of plate heating was a variable. The results of experiment shows below. Pressure drop shows larger in louvered fin type exchanger than in plate fin type exchanger, size of pressure drop shows like this order that fin thickness is 0.3mm, 0.2mm, 0.1mm. Mean heat transfer coefficient shows higher in louvered fin type exchanger than in plate fin type exchanger, size of mean heat transfer coefficient by fin thickness shows same in both case in louvered fin type heat exchanger and plate fin type exchanger like this order that fin thickness is 0.1mm, 0.2mm, 0.3mm.

A LONGITUDINAL STUDY ON THREE FACIAL GROWTH PATTERNS IN KOREANS WITH NORMAL OCCLUSION (정상교합자의 3가지 안면골 성장양상에 관한 누년적 연구)

  • Park, Krung-Duk;Sung, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.25 no.3 s.50
    • /
    • pp.273-286
    • /
    • 1995
  • The purpose of this study was to compare the difference of the growth aspects in three facial growth patterns. The biennial serial cephalometric radiographs of 33 samples(19males, 14females) with normal occlusion from 8.5 years to 18.5 yews of age were used in this study. The facial growth patterrn was categorized in 3 types(Drop type, Neutral type, Forward type) by the total amounts of the Y-axis which changed from 8.5 years to 18.5 years of age. The growth change of the craniofacial area during 10 years in each growth type was analyzed and was compared among the 3 growth types. The results of this study might be summarized as follows. 1. The samples that were classified by total change of the Y-axis during this study period were distributed to 52% of the neutral type, 27% of the forward type, 21% of the drop type. 2. The anterior growth of the maxilla to the cranial base(N per A) showed larger in the forward type than in other 2 types(p<0.05). 3. The palatal plane to the FH plane showed more anterior-superior inclination in the forward type with age during this study period. 4. The anterior growth of the mandible to the cranial base(N per Pog) appeared large in rank order, of largest the forward type, second the neutral type, and third the drop type(p<0.05). 5. During this study period the mandibular plane(SN/MN,FMA) showed more counterclockwise rotation in the forward type than in the drop type(p<0.05), and this tendency was stronger in males than in females(p<0.05). 6. The growth of the mandibular corpus length(Go-Me) showed smaller in the drop type than in the other 2 types(p<0.05). 7. In the forward type and the neutral type, the anterior growth of the mandible was larger than that of the maxilla(p<0.05). 8. In the craniofacial growth distances and angulations turned out to be somewhat variable, but the vertical proportion had a strong tendency whose original relation was maintained consistently during this study period. 9. Through these analyzed data, the profilograms on each growth type were constructed to evaluate individual growth pattern in the orthodontic diagnosis.

  • PDF

Characteristics of Adult Women's Body Somatotype according to Drop Values (성인 여성의 드롭 치수에 따른 체형 특성 연구)

  • Yoon, Ji-Won;Suh, Mi-A
    • The Research Journal of the Costume Culture
    • /
    • v.20 no.4
    • /
    • pp.529-534
    • /
    • 2012
  • An analysis of adult women's somatotypes classified by drop values can provide important preliminary data in determining standard clothing sizes for mass production of ready-made clothes. This is because the values are based on measurements of girth, which is essential information in the size-setting process. Adult women's body types are classified according to drop values in a standard clothing size system adopted by Korea and several other countries. This study aims to identify somatotype characteristics of adult women aged 20 to 69 by using five types of drop values: bust-waist, hip-waist, hip-bust, abdomen-waist, and hip-abdomen. Statistical cluster analysis of collected data revealed four somatotypes among adult women. Type R, with a developed lower body, accounted for 36.6%, and its bodyline was found to be closest to the average adult woman. Type X, constituting 25.4%, had the curviest contours of all and relatively large hip measurements, with the thinnest figure. Flat abdomen and hips characterized type Y, which accounted for 18.9%. Lastly, 19.0% fell into type H, the most obese figure, in which abdomen girth exceeded hip measurements. Since type H has excess fat deposits in the abdomen, not only hip measurements but also abdomen girth should be considered when designing top longer than torso-length and bottoms.

AN EKELAND TYPE VARIATIONAL PRINCIPLE ON GAUGE SPACES WITH APPLICATIONS TO FIXED POINT THEORY, DROP THEORY AND COERCIVITY

  • Bae, Jong-Sook;Cho, Seong-Hoon;Kim, Jeong-Jin
    • Bulletin of the Korean Mathematical Society
    • /
    • v.48 no.5
    • /
    • pp.1023-1032
    • /
    • 2011
  • In this paper, a new Ekeland type variational principle on gauge spaces is established. As applications, we give Caristi-Kirk type fixed point theorems on gauge spaces, and Dane$\check{s}$' drop theorem on seminormed spaces. Also, we show that the Palais-Smale condition implies coercivity on semi-normed spaces.

A Study on Torso Type Classification and Size Analysis for Garment Sizes of Elderly Women (노년 여성의 상의용 의류 치수를 위한 체형 구분 및 신체 치수 분석)

  • Yeo Sun Kang
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.48 no.1
    • /
    • pp.66-81
    • /
    • 2024
  • This study analyzed body shape changes over time by comparing Size Korea's data on 50-84-year-old women from 2020 to 2021 with the same data from 2003 to 2004. In addition, the subjects of these data were divided into drop-types and also upper-body-drop-types with the body measurements for each type compared. The results showed that elderly women had grown 3-4 cm taller over the last 20 years, but the length of 'neck shoulder point to breast point' had become shorter; the bust and waist circumferences were smaller, but the thigh circumference was larger. In the body-drop type, the bust circumference, waist circumference, and waist circumference(Omphalion) increased by about 4-6cm in the order of N-type < H-type < Y-type indicating that the sideline slope of the torso must be differentiated. The upper-body-drop-type showed a 1-cm difference in height and bust circumference, but a 4 to 5-cm difference in waist circumference. In addition, thick-waist subjects aged 70 or older were classified into separate body types with the results showing that their waist circumference was greater than their breast circumference, signifying the need for different top patterns.

The Studying on Drum-type Hill-drop Unit

  • Zhang, Xuejun;Yang, Yin
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.996-998
    • /
    • 1996
  • The drum-type hill-drop unit, an important working device of the plastic -film-covered hill planter, can finish filling and separating seed precisely, perforating film and holing , and its seeding depth and spacing are stability . The unit is applied to hole seed many crops, for example, cotton, corn , soybean, etc. The drum-type hill-drop unit(DHU) , the key work unit to the plastic film-covered planter, mainly consists of distributor box , seeding parts, hole forming unit and drum , It can be operated to accomplish seeds distributing, hole forming , plastic film perforating . Moreover , its inner cavity can be used as seed box.

  • PDF

The Study of Body Type According to Drop Value of Women in Their 20's and Gradient of Brassiere Cup Size (20대 성인 여성의 드롭치에 따른 체형 분류 및 브래지어 컵 사이즈 변화 연구)

  • Jeong, Jin-Ah;Choi, Hei-Sun;Choi, Jeong-Wook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.38 no.6
    • /
    • pp.887-895
    • /
    • 2014
  • The study provides baseline data on developing ready-to-wear clothes for adult females in their twenties who have finished shaping their bodies and have realized an ideal shape. We analyzed the data from females aged from 20 to 29 in "The $5^{th}$ Size Korea Survey" and "The $6^{th}$ Size Korea Survey", and sorted body shapes into several types according to drop values before analyzing and comparing the characteristics among groups. We also referred to the change by year in the size of upper inner wear. To classify body shapes, three drop values were assigned for bust girth - waist girth, hip girth - waist girth, hip girth - bust girth; through cluster analysis all data were classified into three body types. Type 1 is more like normal body shapes with small drop values at the bust girth - waist girth and well-build lower body. Type 2 is X-shaped body shaped like a fiddle with big drop values at all parts. Type 3 is Y-shaped body with a big drop value at the bust girth - waist girth and well-build upper body. Type 2, X-shaped body, has the majority of distribution in every year, which proved to be the most idealistic body shape. There was a change in the brassiere cup size. Korean ladies in their twenties have larger breasts. The body shapes of Korean females in their twenties are increasingly like those of westerners. Bust girth is a very critical element to set measurements and design patterns for upper wear; consequently, a change in the size of breasts should be considered.