• Title/Summary/Keyword: Drop type

Search Result 919, Processing Time 0.027 seconds

A Study on the Classification of Elderly Male's Body Type (노년남성의 체형분류에 관한 연구)

  • 김수현;이정란
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.6
    • /
    • pp.624-634
    • /
    • 2003
  • The purpose of this study was to classify body types of elderly male aged between 60 and 80. 40 direct items and 22 indexes were measured. The result were as follows. First. through the factor analysis of indexes, 8 factors were extracted upon factor scores, 4 clusters represented characteristics of elderly male's body type. Type 1 indicates flat and bend-forward type. Type 2 indicates fat and bend-forward type. Type 3 indicates lean-back type and is a little bit fat and the waist is round. Type 4 indicates a straight type in which the chest and the hip are developed. Second, drop was needed to discriminate elderly male's body type. 3 types of drop were extracted. The body type with big drop is Y type in which the drop distance is between 14 and 22cm. The body type with standard drop is A type in which the drop distance is between 6 and 14cm. The body type with small drop is B type in which the drop distance is between -4 and 6cm. Third, when the types of appearance rate were combined, 7 body types of elderly male showed high appearance rate; A1, B1, A2, B2, A3, A4, B4. According to the above result, flat and bended-forward type with drop A was dominant body type of elderly male.

The Study of Somatotype According to the Drop of Women in Their 20's (20대 여성의 드롭에 따른 체형 연구)

  • Park, Ju-Hee;Hong, Jung-Min;Yoon, Jin-Kyung
    • Fashion & Textile Research Journal
    • /
    • v.7 no.5
    • /
    • pp.494-500
    • /
    • 2005
  • This study classifies somatotype from exact measurements according to the women somatotype with different drop value and isfunctional and has high body fitness. This study was preceded in the following process. Took 147 women in their 20's measurement directly and grasped the general body characteristic, and classified somatotype according to distribution of drop. Drop value is classified into Drop I, Drop II, and Drop III. Drop I is the difference value between bust line and waist line measurement. Drop II is the difference value between hip line and waist line measurement. Drop III is the difference value between hip line and bust line measurement. Suggested distribution of somatotype based on drop istribution. Classified somatotype into 4 types according to the mixture of combination of Drop I, II, and III. Comprehended the characteristics of somatotype based on basic statistical data. Type 1, M type, displays 40 % distribution that is most high distribution rate among four types and it is normal type which is similar to average value in size in the this study. Type 2, A type, displays 32.4% and it's a lower half of their body developed type with a flat busted and hippy. Type 3, X type, displays 19% and it's a healthy type with tall height, slender waist and curves of bust and hip lines. Type 4, H type, displays 8.6% and it's a biggest type in size which is busty, full hipped and nearly has no curves of body line.

Numerical estimation of errors in drop angle during drop tests of IP-Type metallic transport containers for radioactive materials

  • Lim, Jongmin;Yang, Yun Young;Lee, Ju-chan
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.1878-1886
    • /
    • 2021
  • For industrial package (IP)-type transport containers for radioactive materials, a free drop test should be conducted under regulatory conditions. Owing to various uncertainties observed during the drop test, errors in drop angles inevitably occur. In IP-type metal transport containers in which the container directly impacts onto a rigid target without any shock absorbing materials, the error in the drop angle due to a slight misalignment makes a significant difference from the ideal drop. In particular, in a vertical drop, the error in the drop angle causes a strong secondary impact. In this paper, a numerical method is proposed to estimate the error in the drop angle occurring during the test. To determine this error, an optimization method accompanying a computational drop analysis is proposed, and a surrogate model is introduced to ensure calculation efficiency. Effectiveness of the proposed method is validated by performing the verification and comparison between the test and the analysis applied with the drop angle error.

Classification of Body Types for sizes of Ready-to-Wear-focusing on Korean female aged from 18 to 24 (성인 여성의 기성복 치수를 위한 체형 분류)

  • 김경화;남윤자
    • Journal of the Korean Society of Costume
    • /
    • v.53 no.6
    • /
    • pp.145-159
    • /
    • 2003
  • The purpose of this study was to classify body type for ready-to-wear sizes. The subjects were 300 women ages of 18-24. they were measured direct anthropometry. The body types for sizing system were divided by Rohrer Index. KS drop value and ISO drop value. The results of this study were as follows. 1. By adapting the Rohrer Index. we classify 3 types from anthropometric measurements. The thin type covered 39.3%, the standard type 51.0% and the obesity type 18.7%. The characteristics of clusters were as follows. Thin type was characterized by tall. slender type and slim. The standard type was characterized by middle sized. The obesity type was characterized by short. fat type. and large bust. 2. By adapting the KS system drop value. we classify 3 types from anthropometric measurements. The H type(drop 0) covered 25.6%. the N type(drop 6) 65.2% and the A type(drop 12) 9.2%. Type H was slightly tall large bust. and curved from waist to hip. Type A was slightly thin. large hip and smaller bust than type N. Principal factor components were bust size. The height could be divided into three groups. The Petite(l50cm) covered 5.5%. the Regular(l60cm) 64.7% and the Tall(l70cm) 29.8%. Through the crosstab of height and body type. we extracted regular height by N type 46.2% the largest cell. The body type was the higher order of N type. H type and A type. The tall was the higher order of Regular. Tall and Petite. 3. By adapting the ISO system drop value. we classify 3 types from anthropometric measurements. The H type(drop 0) covered 15.0%. the M type(drop 6) 41.0% and the A type(drop 12) 44.0%. Type H was slightly short. slightly fat and large bust. Type A was slightly tall. slight thin than type M. The height could be divided into three groups. We adjust the height section after allow for height distribution. The Short(152cm) covered 12.8%. the Regular(160cm) 66.9% and the Long(168cm) 20.3%. Through the crosstab of height and body type, we extracted regular height by M type 29.3% the largest cell. The body type was the higher order of M type, A type and H type. The tall was the higher order of Regular, Long and short.

A Study of Drop Handles Design

  • Cho, Sook-Kyung;Moon, Sun-Ok
    • Journal of the Korea Furniture Society
    • /
    • v.21 no.3
    • /
    • pp.253-260
    • /
    • 2010
  • The drop handle in the Chosun-Dynasty played a role lifting up the cabinet and box which was attached to and besides this had the decoration function. The scope of this study should include the drop handles from the $18^{th}$ century up to now by investigating and analyzing their definition & function and furthermore the types of their designs. The object of the study was the drop handle having 2 golden fixing parts which are definitive difference from ring or loop, and the design typology of drop handle was concentrated on the handle part, and it can be classified in two types. The one is the figuration of bow, bat, bamboo, fish and bird and so on from the motive of nature on the handle part, and the other one is the drop handle of the simple ㄷ-shape, the temple-symbol shape or geometrical forms. According to the analysis of relics & literature from the past it was found that there were more quantitative nature-motive figurations than the geometrical forms. The nature-motive figurations were again classified in box-, bat-, cloud- bamboo-, fish- and bird-type, and the geometrical forms in ㄷ-shape, the temple-symbol shape and others. The cases applied to furniture are roughly divided into the front-attached type and the side-attached type. In comparison of the drop handle in the Chosun-Dynasty with that of modern times, ㄷ-shape and bow-type keep the long tradition of the drop handles despite of the constructive change partly. Ring-type is similar to the just ring or loop of the part and drop handle with one golden fixing part, while the knob-type shows almost same forms in the past as well as in the modern times. Which type among handles in the modern times has little connection with the past is the reclaimed type, and it was showed in the Chosun-Dynasty and also is showed up to now identically that the man-made hole on the front side of the drawer for the function as handle.

  • PDF

New Mechanism for Wafer Guide to Minimize the Drop in Wafer Transfer (반송 시 웨이퍼 이탈을 최소화 하기 위한 새로운 형태의 웨이퍼 가이드 메커니즘)

  • Kim, Dea-Won;Ryu, Jee-Hwan
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.1
    • /
    • pp.23-28
    • /
    • 2010
  • In this paper, wafer drop from wafer guide mechanism, which is one of the serious problems in water transfer robot, is analyzed, and new wafer guide mechanisms are proposed to minimize this drop. Three types of new wafer guide mechanisms are proposed: roller type, gear type and L-shape rocker type. We choose one of the proposed mechanism, which is roller type, and verified this mechanism through real transfer experiment. Wafer picking up test is conducted with initial aligning error for simulating the wafer drop. Number of drop is compared between conventional mechanism and proposed mechanism. As a result, we can find the proposed mechanism can reduce the number of wafer drop dramatically.

A Preliminary Drop Test of a Type IP-2 Transport Package with a Bolted Lid Type (볼트체결방식의 IP-2형 운반용기의 낙하예비시험)

  • Kim Dong-Hak;Seo Ki-seog;Park Hong Yun;Lee Kyung Ho;Yoon Jeong-Hyoun;Lee Heung-Young
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11a
    • /
    • pp.339-347
    • /
    • 2005
  • A type IP-2 transport package should prevent a loss or dispersal of the radioactive contents and a more than $20\%$ increase in the maximum radiation level at any external surface of the package when it were subjected to the drop test under the normal conditions of transport. If a shielding thickness of IP-2 transport package is thick, a bolted lid type may prevent a loss or dispersal of the radioactive contents than the door type of ISO containers which are generally used as a type IP-2 transport package. In this paper, to evaluate the effect of drop directions on the bolt tension and the coherence of a bolt, the drop tests of preliminary small model are tested and evaluated for seven directions before the drop test of a type IP-2 transport package with a bolted lid type under the normal conditions of transport. Seven drop directions which are a bottom-vertical drop, a lid-vortical drop. a horizontal drop and four corner drops have been carried out. Using a force sensor, the bolt tension during the drop impact is measured. The coherence of bolt is evaluated by the difference between the fastening torque of bolt before a drop test and the unfastening torque of bolt after a drop impact.

  • PDF

The Effects of the Band Type Foot Drop Device (밴드형 첨족예방기구의 효과와 유용성)

  • Kang Hyun-Sook;Kim Won-Ock;Lee Hya-Sook
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.7 no.3
    • /
    • pp.391-400
    • /
    • 2000
  • A long-term bed rest results in an inevitable foot drop. Yet preventive device such as a foot board and high-neck tennis shoes, are not widely used. This study was conducted to compare the effects of a pillow-type foot board with that of the band-type device. The band-type device of a resonable price is designed for an effective prevention of foot drop, and the convenience for it use. Among the non-equivalent control group design, foot drop preventive effects, usefulness of the device, as well as its cost effectiveness were examined. The study was carried out for four months from December 1999, and its subject had been patients and nurses of two intensive care units at K medical center in Seoul. According to the study purpose, the data collected were analyzed by $x^2-test$ and t-test. The results are as follow : 1. The ROM of ankle joint is promoted in the experimental group with a band-type device comparing the control group with a pillow type one. Dorsiflexion is particularly increased in the experimental group as compared with the control group, while planterflexion hardly shows any change. 2. The usefulness score of the experimental group nurses using the band-type device (23.97) is higher than that of the control group nurses (18.88). 3. In an aspect of the unit production cost, band-type devices are low-priced compare with pillow-type or other foot board (wooden) or high-neck tennis shoes. In summary, the newly developed band-type device is both useful and preventive for a foot drop. It is also desirable regarding to the production cost and the cost effectiveness. This fact proves that the new anti-foot drop device could be practical both for clinical care and home care. Yet the results were obtained by some subjects, it should be used after a further examination. More effective nursing intervention could be observed throughout general studies, including proper positioning and foot and ankle exercises which are the important variables of the foot drop prevention.

  • PDF

Theoretical Study on the Heat Transfer Performance in the Various Type Plate Heat Exchanger (다양한 형상의 판형 열교환기 열전달 성능에 관한 해석적 연구)

  • Oh, Jae-Kyeong;An, Sung-Kook;Nam, Snag-Chul;Cho, Hong-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.8
    • /
    • pp.636-645
    • /
    • 2012
  • The performance of various type plate exchangers with different chevron angle, dimple size and arrangement was analysed by using Ansys v13.0. Heat transfer performance, pressure drop and flow patten of plate heat exchanger were investigated according to mass flow ratio investigated and compared. As a result, the $60^{\circ}$-chevron type plate heat exchanger showed the highest heat transfer performance but pressure drop was relatively high. The efficiency of $45^{\circ}$-chevron type plate heat exchanger showed the best performance in considering of heat transfer performance and pressure drop simultaneously. Among dimple type plate heat exchangers, the highest heat transfer performance was shown in a dim_zigzag type plate heat exchanger but pressure drop was very high. Besides, the dim_upsize plate heat exchanger showed very low pressure drop.

Characteristics of Somatotype Classified by the Drop Value of Middle-Aged Women (중년 여성의 드롭치에 따른 체형 특성 연구)

  • Yoon, Ji-Won;Suh, Mi-A
    • The Research Journal of the Costume Culture
    • /
    • v.17 no.6
    • /
    • pp.939-946
    • /
    • 2009
  • This study is to classify the shape of the body by means of the drop value of the middle-age women. Drop value is based on the circumstances of the body deciding the dimentions of the clothes. Therefore, the study based on the drop value seems to decided the measurement of the clothes in making mass production of ready made clothes. In order to put measure items on this study of the value on 'The fifth survey of body measure of Korean', select 785 people in middle-aged women aged from 40 to 59. And considering the characteristic of upper-drop and lower-drop, and swelling belly by accumulated fat, selected five items(Bust Circumstance - Waist Circumstance, Hip Circumstance - Waist Circumstance, Hip Circumstance - Bust Circumstance, Waist Circumstance(Omphalion) - Waist Circumstance, Hip Circumstance - Waist Circumstance(Omphalion)). The result of the study is summarized as follows. Type 1, M type of the body showed the distribution of 32.5% and belonged to low body development style. The line of human body is the nearest of the four bodies in middle-age woman out of whole shapes of 4 types and the line of human body is close to middle-age woman. Type 2, X type of the body showed the distribution of 40.8% and the line of human body remarkably showed. Type 3, H type of the body showed the distribution of 12.4% and the line of human body appears least. This group was larger than any other group in having more fat in the belly above the circumstance of the hip than other groups. Type 4, Y type of the body showed the distribution of 14.4%. This type was upper half of body development style, waist was slender, and there was seldom the bend around the circumstance of belly and hip.

  • PDF