• Title/Summary/Keyword: Drop simulation

Search Result 761, Processing Time 0.022 seconds

Study on Design of 60 V TDMOSFET for Protection Circuit Module (Protection Circuit Module에 최적화된 60 V급 TDMOSFET 최적화 설계에 관한 연구)

  • Lee, Hyun-Woong;Jung, Eun-Sik;Oh, Reum;Sung, Man-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.5
    • /
    • pp.340-344
    • /
    • 2012
  • Protected Circuit Module protects battery from over-charge and over-discharge, also prevents accidental explosion. Therefore, power MOSFET is essential to operate as a switch within the module. To reduce power loss of MOSFET, the on state voltage drop should be lowered and the switching time should be shorted. However there is trade-off between the breakdown voltage and the on state voltage drop. The TDMOS can reduce the on state voltage drop. In this paper, effect of design parameter variation on electrical properties of TDMOS, were analyzed by computer simulation. According to the analyzed results, the optimization was performed to get 65% higher breakdown voltage and 17.4% on resistance enhancement.

A Study on an Adaptive AQM Using Queue Length Variation

  • Seol, Jeong-Hwan;Lee, Ki-Young
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.1
    • /
    • pp.19-23
    • /
    • 2008
  • The AQM (Active Queue Management) starts dropping packets earlier to notify traffic sources about the incipient stage of congestion. The AQM improves fairness between response flow (like TCP) and non-response flow (like UDP), and it can provide high throughput and link efficiency. In this paper, we suggest the QVARED (Queue Variation Adaptive RED) algorithm to respond to bursty traffic more actively. It is possible to provide more smoothness of average queue length and the maximum packet drop probability compared to RED and ARED (Adaptive RED). Therefore, it is highly adaptable to new congestion condition. Our simulation results show that the drop rate of QVARED is decreased by 80% and 40% compare to those of RED and ARED, respectively. This results in shorter end-to-end delay by decreasing the number of retransmitted packets. Also, the QVARED reduces a bias effect over 18% than that of drop-tail method; therefore packets are transmitted stably in the bursty traffic condition.

Characteristics of Latch-up Current of the Dual Gate Emitter Switched Thyristor (Dual Gate Emitter Switched Thyristor의 Latch-up 전류 특성)

  • 이응래;오정근;이형규;주병권;김남수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.8
    • /
    • pp.799-805
    • /
    • 2004
  • Two dimensional MEDICI simulator is used to study the characteristics of latch-up current of Dual Gate Emitter Switched Thyristor. The simulation is done in terms of the current-voltage characteristics, latch-up current density, ON-voltage drop and electrical property with the variations of p-base impurity concentrations. Compared with the other power devices such as MOS Controlled Cascade Thyristor(MCCT), Conventional Emitter Switched Thyristor(C-EST) and Dual Channel Emitter Switched Thyristor(DC-EST), Dual Gate Emitter Switched Thyristor(DG-EST) shows to have the better electrical characteristics, which is the high latch-up current density and low forward voltage-drop. The proposed DG-EST which has a non-planer p-base structure under the floating $N^+$ emitter indicates to have the better characteristics of latch-up current and breakover voltage.

The Voltage Drop Compensation of Electric Railway Feeding system using a Fuelcell System (연료전지 시스템을 이용한 전기철도 급전계통 전압강하 보상)

  • Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.342-348
    • /
    • 2015
  • In this paper, fuel cell power generation system that is being studied in recent railway field was applied to compensate for the voltage drop due to the load as driving electric vehicle. PSIM simulation program is to be used to implement the modeling of the electric railway for AC AT feeder system. For it, It was applied to the product-type single-phase PLL algorithm, step-down converter is controlled as power so as to have the fuelcell generation system. Based on it's result, a reactive power due to the catenary impedance in accordance with the current flowing is compensated as linked with fuelcell generation system which supplied the current to the power supply grid. and then its performance was confirmed that voltage compensation effect obtained at SubStation (SS), SubSectioning Post (SSP), Sectioning Post (SP).

Heat Transfer and Pressure Drop Characteristics for Various Tube Geometries in Modular Tube Bundle Heat Exchanger (모듈형 관군 열교환기에서의 관 형상에 따른 열전달 및 압력강하 특성에 관한 연구)

  • Yoon, Joon-Shik;Park, Byung-Kyu;Kim, Cham-Jung
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.105-111
    • /
    • 2000
  • A numerical study has been performed to obtain the heat transfer and pressure drop characteristics for shell-and-tube heat exchanger with various shapes of tubes. The Tubes have variation of Aspect Ratio, Pitch and Rotation. Results are presented as plots of Colburn j factor and friction factor f against Aspect Ratio, Pitch and Rotation. As Aspect Ratio increases, j factor and f factor decreases. As Pitch increases, j factor decreases. j/f have optimized Pitch for each Aspect Ratio. Accordingly, there is fitness of Aspect Ratio and Pitch fur most effective cases. The Rotation of tubes are of no meaning for both heat transfer and pressure drop.

  • PDF

The pressure drop characteristics in LNG heat exchanger of cryogenic cascade refrigeration cycle (초저온 캐스케이드 냉동사이클의 LNG 열교환기 압력강하 특성)

  • Yoon, J.I.;Choi, K.H.;Kwag, J.W.;Son, C.H.;Baek, S.M.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.376-381
    • /
    • 2012
  • Natural gas is converted in to LNG by chilling and liquefying the gas to the temperature of $-162^{\circ}C$, when liquefied, the volume of natural gas is reduced to 1/600th of its standard volume. This gives LNG the advantage in transportation. The pressure dorp of the cascade liquefaction cycle was investigated and simulated using HYSYS software. The simulation results showed that the pressure drop in the LNG heat exchanger is set to 50 kPa considering the increase in the compressor work of cryogenic cascade liquefaction cycle.

  • PDF

Numerical Study on The Pressure Drop of Immiscible Two-Phase Flow in The Pressure Driven Micro Channel Using Lattice Boltzmann Method (Lattice Boltzmann 방법을 이용한 압력구동 미세채널 내 비혼합 2상 유체 흐름의 압력강하에 대한 수치적 연구)

  • Jeong, Soo-In;Kim, Kui-Soon;Kang, Beom-Soon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.436-439
    • /
    • 2008
  • Computer simulation of multiphase flows has grown dramatically in the last two decades. In this work, we have studied the flow characteristics of immiscible two fluids in a 2-D micro channel driven by pressure gradient using multi-phase lattice Boltzmann method suggested by Shan and Chen(1993) considering the fluid-surface interaction. we tried to examine the effects of parameters related to the two phase flow characteristics and pressure drop in the micro channel like contact angle and channel configuration by changing their value. The results of current study could show the lattice Boltzmann method can simulate the behaviors of two phase flow in the region of micro fluidics well.

  • PDF

A Study on the Development of Fuel Metering Unit for Air Breathing Engine (공기흡입식 추진기관용 연료조절밸브시스템 개발에 관한 연구)

  • Lee, Do-Yun;Choi, Hyun-Young;Park, Jong-Seung;Koo, Ja-Yoeng
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.8 no.4 s.23
    • /
    • pp.152-158
    • /
    • 2005
  • In this paper, we have proposed a fuel metering unit of ai breathing engine. The proposed valve system consists of a constant pressure drop valve and a metering valve, which are controlled by servovalve. We carried out nonlinear and linear analysis, computer simulation and experimentation to find effects of some factors on system performance. Analysis and experimental results show a good agreement. It is also shown that the system stability is affected by pressure drop of metering valve and inlet pressure of injectors.

Effects of Two Stage Vortex Finder on the Particulate Collection Efficiency of Cyclone Separator (2단 선회류 약화기가 원심력집진기의 집진효율에 미치는 영향)

  • 강순국;유경선
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.6
    • /
    • pp.633-640
    • /
    • 2000
  • The effects of structure modification of the vortex finder on the collection efficiency and pressure drop have been investigated. The pressure drop in a cyclone having the two stage vortex finder is higher than that in a conventional cyclone and increases proportionally with the increase of square of gas inlet velocity in both cases. The pressure drop of both conventional cyclone of friction resistance at the boundary layer. The collection efficiency of fine dust has been enhanced by addition of vortex finder in a conventional cyclone and gas inlet velocity showing maximum dust removal efficiency increase to 17 m/s(1.7 times of saltation velocity). Optimum size of two stage vortex finder has been induced to 13 cm I.D$\times$2.6cm Length from the results of overall dust collection efficiency. Previous models were tested for the simulation of collection efficiency of cyclone having two stage vortex finder and the Dietz model predict the similar value with experimental results of the present study.

  • PDF

Compensation of Voltage Drop Using the SVC in Electric Railway Power Supply System (SVC를 이용한 전기철도 급전시스템에서의 전압강하 보상)

  • Bang, Seong-Won;Jung, Hyun-Soo;Jung, Chang-Ho;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.289-291
    • /
    • 2001
  • This paper represents the application of the Static Var Compensator (SVC) on the electric railway power supply system to compensate for the voltage drop. The high reactance of line and a heavy train load consume a significant amount of the reactive power which results the voltage drop. This paper shows that the SVC is necessary for voltage compensation in the railway power supply system and verify effectiveness of the SVC through the simulation by using PSCAD/EMTDC. In this paper, the case studies were performed with the various line length and train loads.

  • PDF