• 제목/요약/키워드: Drop analysis

검색결과 1,894건 처리시간 0.025초

강제 환기식 육계사 다중 입기 슬롯에서의 입기류 도달거리 분석 (Analysis of Jet-drop Distance from the Multi Opening Slots of Forced-ventilation Broiler House)

  • 권경석;하태환;이인복;홍세운;서일환
    • 한국농공학회논문집
    • /
    • 제54권2호
    • /
    • pp.55-65
    • /
    • 2012
  • In the winter season, when the ventilation system is operating, the fresh cold air from the slot-type openings of broiler house which directly reached the animal zone can cause various problems such as thermal stress, decreasing of feed and water consumption, occurrence of respiratory disease, and etc. Therefore it is very important to control the trajectory of aero-flow from the slot openings to induce an efficient thermal heat change. Jet-drop distance model was proposed to predict and control the jet-trajectory. However their study was restricted due to the small scaled model and difficulties of measuring the Jet-drop distance. In this study, CFD was applied to analyze qualitatively and quantitatively the jet-drop distance in a real broiler house. The various variables were considered such as installed slot-angle, designed ventilation rate, and the outdoor ambient temperature. From the present study, two linear-regression models using the Jet-drop factor and corrected Archimedes number, and their R-squared values 0.744 and 0.736, respectively, were used. From this study, the applicability of CFD on the analysis of Jet-drop distance model was confirmed.

충격기류식 여과집진기에서 경험모델을 이용한 최소압력손실의 분사거리 예측 (The Prediction of Injection Distances for the Minimization of the Pressure Drop by Empirical Static Model in a Pulse Air Jet Bag Filter)

  • 서정민;박정호;임우택
    • 한국환경과학회지
    • /
    • 제20권1호
    • /
    • pp.25-34
    • /
    • 2011
  • The new empirical static model was constructed on the basis of dimension analysis to predict the pressure drop according to the operating conditions. The empirical static model consists of the initial pressure drop term (${\Delta}P_{initial}$) and the dust mass number term($N_{dust}=\frac{{\omega}_0{\nu}_f}{P_{pulse}t}$), and two parameters (dust deposit resistance and exponent of dust mass number) have been estimated from experimental data. The optimum injection distance was identified in the 64 experimental data at the fixed filtration velocity and pulse pressure. The dust deposit resistance ($K_d$), one of the empirical static model parameters got the minimum value at d=0.11m, at which the total pressure drop was minimized. The exponent of dust mass number was interpreted as the elasticity of pressure drop to the dust mass number. The elasticity of the unimodal behavior had also a maximum value at d=0.11m, at which the pressure drop increased most rapidly with the dust mass number. Additionally, the correlation coefficient for the new empirical static model was 0.914.

Sn-3.0Ag-0.5Cu 및 Sn-1.0Ag-0.5Cu 조성의 솔더 볼을 갖는 플립칩에서의 보드레벨 낙하 해석 (Board-Level Drop Analyses having the Flip Chips with Solder balls of Sn-3.0Ag-0.5Cu and Sn-1.0Ag-0.5Cu)

  • 김성걸
    • 한국생산제조학회지
    • /
    • 제20권2호
    • /
    • pp.193-201
    • /
    • 2011
  • Recently, mechanical reliabilities including a drop test have been a hot issue. In this paper, solder balls with new components which are Sn-3.0Ag-0.5Cu and Sn-1.0Ag-0.5Cu-0.05N are introduced, and board level drop test for them are conducted under JEDEC standard in which the board with 15 flip chips is dropped as 1,500g acceleration during 0.5ms. The drop simulations are studied by using a implicit method in the ANSYS LS-DYNA, and modal analysis is made. Through both analyses, the solder balls with new components are evaluated under the drop. It is found that the maximum stress of each chip is occurred between the solder ball and the PCB, and the highest value among the maximum stresses in the chips is occurred on the chip nearest to fixed holes on the board in the drop tests and simulations.

판형열교환기의 열전달특성 및 압력강하에 관한 해석적 연구 (Numerical Analysis on Heat Transfer Characteristics and Pressure Drop in Plate Heat Exchanger)

  • 김광률;김일겸;임장순
    • 한국태양에너지학회 논문집
    • /
    • 제22권2호
    • /
    • pp.19-26
    • /
    • 2002
  • This study aims at numerically analyzing on heat transfer the characteristics and pressure drop of plate heat exchanger(PHE) using the Phoenics 3.1 VR Editor for the standard k-$\varepsilon$ model. Computations have been carried out for a range of chevron angle from $30^{\circ}$ to $60^{\circ}$, inlet velocity from 0.03m/s to 0.63m/s and the height of corrugation from 0.0045m to 0.0060m. The results show that both of heat transfer performance and pressure drop increase as chevron angle increases. This is because higher troughs produce higher turbulence and a higher heat transfer coefficient in the liquids flowing between the plates. As inlet velocity from 0.03m/s to 0.63m/s increases, heat transfer performance and pressure drop increase parabolically. As the height of corrugation increases, both of heat transfer performance and pressure drop decrease with the decrease of velocity. And the pressure drop decreases and the friction factor increases as the height of corrugation increases.

냉연판의 엣지드롭 해석 및 제어용 수식모델 개발 (Analysis of edge drop and development of numerical formula for edge drop control of cold rolled sheet)

  • 송길호;박해두;진철제;신성갑
    • 대한기계학회논문집A
    • /
    • 제22권4호
    • /
    • pp.723-730
    • /
    • 1998
  • With the introduction of edge drop control system in Tandem Cold Rolling Mill, it is necessary to develop te numerical expression for the set-up and edge drop automatic control of cold rolled sheet. As a first step we developed a simulation program which predicts profile and the amounts of edge drop at the delivery side of each stand by using roll deformation anlysis with the slit roll model. And by using the program the effect of various rolling conditions on edge drop was investigated. As a result the relations were obtained between the amounts of edge drop and rolling conditions. Based on above relations, the numerical expression was developed for the set-up and automatic control of edge drop by multi-regression of simulation results for the variation of edge drop amount with each rolling condition.

Influence of design modification of control rod assembly for Prototype Generation IV Sodium-cooled Fast Reactor on drop performance

  • Son, Jin Gwan;Lee, Jae Han;Kim, Hoe Woong;Kim, Sung Kyun;Kim, Jong Bum
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.922-929
    • /
    • 2019
  • This paper presents the drop performance test of the control rod assembly which is one of the main components strongly related to the safety of the prototype generation IV sodium-cooled fast reactor. To investigate the drop performance, a real-sized control rod assembly that was recently modified based on the drop analysis results was newly fabricated, and several free drop tests under different flow rate conditions were carried out. Then the results were compared with those obtained from the previous tests conducted on the conceptually designed control rod assembly to demonstrate the improvement in performance. Moreover, the drop performance tests under several types and magnitudes of seismic loadings were also conducted to investigate the effect of the seismic loading on the drop performance of the modified control rod assembly. The results showed that the effects of the type and magnitude of the seismic loading on the drop performance of the modified control rod assembly were not significant. Also, the drop time requirement was successfully satisfied, even under the seismic loading conditions.

낙하 충격에 의한 풍화토의 비산먼지 발생 특성 분석 (Analysis of dust emission characteristic by drop impact on decomposed granite soil)

  • 민슬기;손영환;박재성;노수각;봉태호
    • 한국농공학회논문집
    • /
    • 제56권3호
    • /
    • pp.39-45
    • /
    • 2014
  • Dust is mostly caused by human activity. The effect of natural factors on dust emission were studied in many research, but the little effort in researching artificial factors of dust emission. The object of study is to analysis dust emission characteristic by drop impact. Particle matter $10{\mu}m$ ($PM_{10}$) was measured by drop impact on paved soil with changing drop height, weight and drop size. Increasing drop height cause more $PM_{10}$ emission. Increasing drop weight cause more $PM_{10}$ emission but had limit weight for increasing dust emission. Because the exceed kinetic energy of drop weight penetrate the soil surface. The limit perimeter was exist that separating $PM_{10}$ emission aspect. Under limit perimeter, $PM_{10}$ emission was increasing while perimeter was increasing, but over limit perimeter showed the opposite aspect. Regression equations for estimating $PM_{10}$ with kinetic energy and perimeter were made under limit perimeter and over limit perimeter. The $R^2$ of those equations were 0.784, 0.743. The error has occurred between measured $PM_{10}$ and calculated $PM_{10}$ in the equation under limit perimeter. But using equation of case for over limit perimeter, PM10 can be estimated with kinetic energy and drop perimeter.

충격해석을 통한 결과의 예측 (The Prediction of the Results of Drop Test Through Shock Analysis)

  • 박용석;홍성철;박철희;이우식;조항법
    • 소음진동
    • /
    • 제4권3호
    • /
    • pp.345-352
    • /
    • 1994
  • Electronic products can be subjected to many different forms of shock. These shocks are usually experienced during transporting the electronic products from a manufacturer to customers. Drop tests are performed to test the product fragility before shipment. Package cushioning materials are often used to protect electronic products from severs shock environments. In the present paper, an algorithm to predict the shock responses of the main mechanical parts is developed by use of the shock analysis in which the modal parameters extracted from vibration test are used. These results are in good agreement with the results of drop test. By use of the shock response prediction algorithm developed herein, it is possible to predict the results of drop test at various drop directions and also to select the optimal package cushioning materials.

  • PDF

수소연료전지 차량 충전에서의 압력강하 분석 (Pressure Drop Analysis on Filling of Hydrogen Fuel Cell Vehicles)

  • 서효민;박병흥
    • 한국가스학회지
    • /
    • 제27권1호
    • /
    • pp.38-47
    • /
    • 2023
  • 수소연료전지 차량 충전 과정에서, 충전소에서의 공급압력과 차량 내 저장 탱크의 압력 차이에 의해 수소가 흐르게 되고 유량은 압력 차에 의존한다. 따라서 충전 과정에서 발생하는 수소의 압력강하에 대한 고려는 필수적이며 이의 분석을 통해 수소 충전 과정의 효율성을 높일 수 있다. 본 연구에서는 충전라인 중 호스, 노즐/리셉터클, 파이프, 밸브에 대하여 압력강하를 분석하였다. 호스와 파이프는 도관에서의 압력강하로, 노즐/리셉터클은 흐름 노즐 식으로, 밸브는 기체 유량 식으로 계산하였다. 또한 각 구성요소에서 발생하는 압력강하 효과를 종합 분석한 결과 전체 충전라인에서 압력강하에 가장 큰 영향을 주는 요소는 밸브에서의 압력강하임이 밝혀졌다. 이번 연구는 추후 수소 충전을 포함한 수소 유동 해석으로 수소 충전 과정의 모델 개발에 활용될 수 있을 것이다.

노년남성의 체형분류에 관한 연구 (A Study on the Classification of Elderly Male's Body Type)

  • 김수현;이정란
    • 한국의류학회지
    • /
    • 제27권6호
    • /
    • pp.624-634
    • /
    • 2003
  • The purpose of this study was to classify body types of elderly male aged between 60 and 80. 40 direct items and 22 indexes were measured. The result were as follows. First. through the factor analysis of indexes, 8 factors were extracted upon factor scores, 4 clusters represented characteristics of elderly male's body type. Type 1 indicates flat and bend-forward type. Type 2 indicates fat and bend-forward type. Type 3 indicates lean-back type and is a little bit fat and the waist is round. Type 4 indicates a straight type in which the chest and the hip are developed. Second, drop was needed to discriminate elderly male's body type. 3 types of drop were extracted. The body type with big drop is Y type in which the drop distance is between 14 and 22cm. The body type with standard drop is A type in which the drop distance is between 6 and 14cm. The body type with small drop is B type in which the drop distance is between -4 and 6cm. Third, when the types of appearance rate were combined, 7 body types of elderly male showed high appearance rate; A1, B1, A2, B2, A3, A4, B4. According to the above result, flat and bended-forward type with drop A was dominant body type of elderly male.