• Title/Summary/Keyword: Drop analysis

Search Result 1,883, Processing Time 0.032 seconds

Comparison of Underwater Drop Characteristics for Hazard Apparatuses on Subsea Cable Using Fluid-Structure Interaction Analysis (유체-구조 연성해석 기반 해저케이블 위해인자의 수중낙하 특성 비교)

  • Jang, Gyung-Ho;Kim, Jeong-Hun;Song, Chang Yong
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.324-332
    • /
    • 2018
  • It is known that damages to the subsea cables used for electric power transmission between islands and countries, including renewable energy from offshore wind power, current, tides, etc., cost much to restore, which causes social and economic losses. Various types of fishing rigs and anchors have been reported to be the greatest hazards to subsea cables. It is possible to design and construct a suitable protection facility for a subsea cable by precisely estimating the underwater behavior of such hazardous apparatuses. In this study, numerical simulations of the underwater behaviors of various hazardous apparatuses were carried out using fluid-structure interaction (FSI) analysis as a basic study to simulate the actual behavior phenomena of hazardous apparatuses in relation to a subsea cable. In addition, the underwater drop characteristics according to the types of hazardous apparatuses were compared. In order to verify the accuracy of the FSI analysis method used in this study, we compared the test results for underwater drops of a steel ball bearing. Stock anchors, stockless anchors, and rocket piles, which were actually reported to be the cases of damage to subsea cables along the southwest coast of Korea, were considered as the hazardous apparatuses for the numerical simulations. Each hazardous apparatus was generated by a Lagrangian model and coupled with the fluid domain idealized by the Eulerian equation to construct the three-dimensional FSI analysis model. The accuracy of the numerical simulation results was verified by comparing them with the analytical solutions, and the underwater drop characteristics according to the types of hazard apparatuses were compared.

Analysis of Flow Characteristics of Triple Filter System by the Influence of Filter Density (필터 조밀도의 영향에 의한 3단 필터 시스템의 유동특성 해석)

  • In-Soo Son
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_2
    • /
    • pp.1163-1169
    • /
    • 2023
  • In this study, the flow characteristics of the filter system were analyzed due to the effect of the density of the filter in the triple filter system. Flow analysis was performed as a flow passing through a porous medium. The flow characteristics of each filter system were analyzed by arranging filters with different densities in the forward flow flow and the reverse flow. The arrangement order of the triple filters was excellent in the case of forward fluid flow and in the case of higher density from the inside to the outside filter. In the reverse flow filter system, the performance of the system was the best in the case of reverse order filter arrangement. As a result of the analysis, Case II, which showed a pressure drop rate of 5.65% for forward flow, was the best in the reverse direction with a pressure drop rate of 14.25%. Considering reverse and forward flows, it was found that the optimal filter arrangement was most effective when the intermediate filter was the densest, and the inner or outer filter was less dense.

A Numerical analysis on the pressure drop of the flow field past a two-staged orifice in a rectangular duct (사각덕트 내 이단 오리피스를 지나는 유동의 압력강하에 대한 수치해석)

  • Song, Woo-Yeol;Kim, You-Gon
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2747-2752
    • /
    • 2007
  • A numerical study has been performed on the flow past a two-staged orifice in a rectangular duct. The flow field including the recirculation region behind the orifice was investigated and the pressure drop was calculated. Water was used as a working fluid and the flow was treated as the turbulent flow, of which the Raynolds number was 6000. The main parameters for the pressure drop and the recirculation region were the orifice's inclined angle against the duct, the interval between two orifices, the shape of the orifice's hole having the same area, and the change of the hole position at the same interval. The variation of the flow field was investigated with each parameter. Consequently, it was found that the most dominant parameter influencing the drop of the pressure was the change of the hole position at the same interval between orifices. Especially when the interval between orifices was narrow and the relative position the holes was changed, its effect to the flow field was shown most drastically as a result of this study. The SIMPLER algorithm with FLUENT code was employed to analyze the flow field.

  • PDF

Numerical Analysis of the Behavior of Bars in a Compound Channel with a Drop Structure (낙차공이 있는 복단면 수로에서 사주거동의 수치분석)

  • Kim, Gi-Jung;Jang, Chang-Lae
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.1
    • /
    • pp.14-21
    • /
    • 2016
  • This study investigated the behavior of sediment bars in a compound channel with a drop structure. Flow was separated into side banks by alternate bars, and flow was concentrated into the downstream of bar fronts. The bed downstream of a drop structure degradated due to the concentrated flow from it. Bar shapes were kept by the influence of their shapes upstream. Alternate bars, central bars, and multiple bars were developed as the width to depth ratio increased, and the number of bars increased. The bar in the downstream of a drop structure decreased in length due to the concentration of flow and its disturbance.

Scaling of ground motions from Vrancea (Romania) earthquakes

  • Pavel, Florin;Vacareanu, Radu
    • Earthquakes and Structures
    • /
    • v.11 no.3
    • /
    • pp.505-516
    • /
    • 2016
  • This paper evaluates the scaling of ground motions recorded from nine intermediate-depth earthquakes produced in the Vrancea seismic zone in Romania. The considered ground motion database consists of 363 horizontal recordings obtained on soil classes B and C (according to Eurocode 8). An analysis of the inter- and intra-event spectral accelerations is performed in order to gain information regarding the magnitude and distance scaling of the Vrancea ground motions. The analyses reveal a significant influence of the earthquake magnitude and focal depth on the distance scaling and different magnitude and distance scaling for the two soil classes. A linear magnitude and distance scaling is inferred from the results for the range of magnitudes $5.2{\leq}M_W{\leq}7.1$. The results obtained are checked through stochastic simulations and the influence of the stress drop and kappa values on the ground motion levels is assessed. In addition, five ground motion models which were tested in other studies using recordings from Vrancea earthquakes are analyzed in order to evaluate their corresponding host stress drop and kappa. The results show generally a direct connection between the host kappa values and the host stress drop values. Moreover, all the ground motion models depict magnitude dependent host kappa and stress drop levels.

A Study Comparison and Analysis of Electrical Characteristics of IGBTs with Variety Gate Structures (다양한 게이트 구조에 따른 IGBT 소자의 전기적 특성 비교 분석 연구)

  • Kang, Ey Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.11
    • /
    • pp.681-684
    • /
    • 2016
  • This research was carried out experiments of variety IGBTs for industrial inverter and electric vehicle. The devices for this paper were planar gate IGBT, trench gate IGBT and dual gate IGBT and we designed using same design and process parameters. As a result of experiments, the electrical characteristics of planar gate IGBT were 1,459 V of breakdown voltage, 4.04 V of threshold voltage and 4.7 V of on-state voltage drop. And the electrical characteristics of trench gate IGBT were 1,473 V of breakdown voltage, 4.11 V of threshold voltage and 3.17 V of on-state voltage drop. Lastly, the electrical characteristics of dual gate IGBT were 1,467 V of breakdown voltage, 4.14 V of threshold voltage and 3.08V of on-state voltage drop. We almost knew that the trench gate IGBT was superior to dual gate IGBT in terms of breakdown voltage. On the other hand, the dual gate IGBT was better than the trench gate IGBT in terms of on state voltage drop.

The Thermal and Flow Analysis in the Channel of Plate Heat Exchanger with Crossed-Discrete Ribs (직교하는 단락형 리브를 부착한 판형 열교환기 관내측 열유동 해석)

  • Lee, Kwan-Soo;Moon, Hyoung-Kyu;Chung, Kilyoan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.5
    • /
    • pp.678-686
    • /
    • 1999
  • The purpose of this work is to Investigate the pressure drop and the heat transfer characteristics in the channel of plate heat exchanger with crossed-discrete ribs. The flow is assumed to be three-dimensional, laminar and periodically fully developed. Computations have been carried out for angles of attack from $0^{\circ}$ to $90^{\circ}$ and ratios of rib height from 0.15 to 0.46 for various values of Reynolds and Prandtl numbers. The heat transfer was improved by inclined ribs generating helical vortices and secondary flows. The results show that the pressure drop has a maximum value at $70^{\circ}$ and the heat transfer has a maximum value at $45^{\circ}$. As the rib height increases, the pressure drop and the heat transfer increase quadratically, and the increasing rate of pressure drop is higher than that of the heat transfer. As Reynolds number increases, the pressure drop increases in proportion to the square of Reynolds number and the heat transfer increases linearly.

Split-Step Time-Domain Analysis and Design of an Fiber-Optic Coupler Add/Drop Filter (광섬유 커플러 Add/Drop 필터의 연산자 분리 시영역 해석 및 설계)

  • Kang, Joon-Hwan;Kim, Byoung-Sung;Chung, Young-Chul
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.8
    • /
    • pp.57-66
    • /
    • 2000
  • Add-drop filtering effect of a asymmetric fiber-optic coupler ADF(add/drop filter) is analyzed using a new split-step time-domain model. This model is very useful in simulating the devices containing a directional coupler an Bragg gratings, First, a symmetric fiber-optic coupler ADM is analyzed using this model to confirm the accuracy of the new method. Then, an asymmetric fiber-optic coupler ADF is analyzed, and some design parameters for optimal filtering effect is derived.

  • PDF

Analysis on condensation heat transfer and pressure drop to develop design program for plate heat exchangers (판형열교환기 설계프로그램 개발을 위한 응축열전달 및 압력강하 분석)

  • Ko, Jea-Hyun;Song, Young-Ho;Park, Kweon-Ha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.376-382
    • /
    • 2014
  • The purpose of this study is to get the formulas of condensation heat transfer coefficient and pressure drop about the water to develop design program for plate type heat exchangers. The single phase flow of cold side was calculated with the correlation of Ko. Condensation heat transfer coefficient model proposed by Annaiev was used and Lockhart model was used to analyze the pressure drop. The calculation algorithm was proposed to calculate heat transfer rate and pressure drop simultaneously. The prediction errors remained within 20% compared to the commercial code in the working range of the plate heat exchangers.

The Effect of Raised Heel Insole and Landing Height on the Shock Absorption Mechanism during Drop Landing (드롭 착지 시 착지의 높이와 키 높이 깔창이 충격흡수 기전에 미치는 영향)

  • Cho, Joon-Haeng;Kim, Ro-Bin
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.2
    • /
    • pp.131-138
    • /
    • 2014
  • The purpose of this study was to analyse the effect of the drop height on lower extremity and lower back kinematics and kinetics during drop landing with the use of raised heel insole. Furthermore we investigated the change that occurred in our body. Joint ROM, eccentric work and contribution to total work were calculated in 11 male college students performing drop landing with 8 motion analysis cameras and 1 forceplate. The result were as follows. First, the ROM and eccentric work were increased in all joints with the increase of the drop height. Second, the ankle ROM and eccentric work were decreased with the use of the insole. Third, the use of the lower back was increased as the use of the ankle decreased with the insole. Based on these results, we can infer that putting on the insole may contribute to chronic injury. We recommend not to use the insole during physical activity.