• Title/Summary/Keyword: Drop analysis

Search Result 1,883, Processing Time 0.027 seconds

Repair Cost Analysis for RC Structure Exposed to Carbonation Considering Log and Normal Distributions of Life Time (탄산화에 노출된 철근콘크리트 구조물의 로그 및 정규 수명분포를 고려한 보수비용 해석)

  • Woo, Sang-In;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.3
    • /
    • pp.153-159
    • /
    • 2018
  • Many researches have been carried out on carbonation, a representative deterioration in underground structure. The carbonation of RC (Reinforced Concrete) structure can cause steel corrosion through pH drop in concrete pore water. However extension of service life in RC structures can be obtained through simple surface protection. Unlike the conventional deterministic maintenance technique, probabilistic technique can consider a variation of service life but it deals with only normal distributions. In the work, life time-probability distributions considering not only normal but also log distributions are induced, and repair cost estimation technique is proposed based on the induced model. The proposed technique can evaluate the repair cost through probabilistic manner regardless of normal or log distribution from initial service life and extended service life with repair. When the extended service life through repair has log distribution, repair cost is effectively reduced. The more reasonable maintenance strategy can be set up though actual determination of life-probability distribution based on long term tests and field investigations.

Administration order of midazolam/fentanyl for moderate dental sedation

  • Lobb, Douglas;Clarke, Alix;Lai, Hollis
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.18 no.1
    • /
    • pp.47-56
    • /
    • 2018
  • Background: The purpose of this study is to investigate the effects of administration order when a sedative drug (midazolam) and an opioid analgesic drug (fentanyl) is applied for moderate intravenous (IV) sedation in dentistry. Methods: A retrospective chart review was conducted in one dental clinic during its transition from a midazolam-first to a fentanyl-first protocol for dental procedures requiring moderate IV sedation. Physiological parameters, drug administration times, patient recovery times, drug dosages, and patient recall and satisfaction were investigated for differences. Results: A total of 76 charts (40 midazolam-first and 36 fentanyl-first administrations), were used in the analysis. Administering midazolam first resulted in an average 4.38 min (52%) decrease in administration times (P < 0.001), and a decrease in procedural recollection immediately following the procedure (P = 0.03), and 24 to 48 hours later (P = 0.009). Administering fentanyl first required an average of 2.43 mg (29%) less midazolam (P < 0.001). No significant differences were found for change in vital signs, minimum oxygen saturation levels, recovery times, and patient satisfaction (P > 0.05). Oxygen saturation levels did not drop below 90% for either group; however, 5 cases in the fentanyl-first group fell to between 90% and 92%, compared with 0 cases in the midazolam-first group. Conclusions: The administration order of fentanyl and midazolam may have different effects on patients and the sedation procedure. Findings from this study should be used to facilitate discussion among dental practitioners and to guide additional research investigating this topic.

태양 주위에 있는 만기형 주계열성의 자전에 관한 연구

  • Yang, Eun-Su;Lee, Sang-Gak
    • Publications of The Korean Astronomical Society
    • /
    • v.4 no.1
    • /
    • pp.31-52
    • /
    • 1989
  • The rotational properties of late-type main sequence stars in the solar neighborhood have been investigated. So rotation periods and stellar radii are determined for 104 field stars, 8 Ursa Major Group stars, and 20 Hyades cluster stars. Most of the rotation periods are derived using the Noyes et al. (1984)'s relation between chromospheric activity and rotation period. Stellar radii are calculated by the Stefan law for the nearby stars within 25 pc from the sun. Rotational velocities at equator are determined by the above rotation periods and stellar radii. Their distribution along the (B-V) color shows an upper boundary and an abrupt drop for the stars in the range of 0.4<(B-V)<0.8, as found from the apparent rotational velocity data. Furthermore, it is apparent that there is an lower boundary of rotational velocity. The inclination of rotation axis to line-of-sight is obtained by comparing the rotational velocity at equator with the apparent rotational velocity given by the analysis of the line profiles. For the field stars, it is found that the inclination has no correlation with the galactic lattitude and follows random distribution.

  • PDF

Analysis on the Modification of Near-wall Turbulent Characteristics of Temperature Field in a Channel imposed with Linearly Increasing Wall Disturbance (선형적으로 증가하는 벽면교란이 벽 근처 난류 온도장의 특성 변화에 미치는 영향 해석)

  • Park, Soo Hyung;Byun, Yung-Hwan;Na, Yang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.5
    • /
    • pp.101-112
    • /
    • 2013
  • Large eddy simulation was performed to investigate the effect of linearly increasing wall disturbance on the modification of turbulent characteristics of temperature field in the vicinity of the wall. It was noted that temperature variance increased monotonically whereas temperature dissipation decreased significantly, resulting in a noticeable reduction in both time and length-scales. A sudden drop in turbulent Prandtl number down to around 0.25 in the near-wall region indicated that the similarity between velocity and temperature fields decreases near the wall as a result of linear wall disturbance.

Characteristics of the Onset of Flooding for Countercurrent Air-Water Flow in Vertical Annuli with a Direct Injection Mode (수직 환상관내 반류 공기-물 유동에서 직접분사방식에 따른 플러딩 시작점 특성)

  • Lee, S.C.;Shin, I.H.;Lee, S.M.;Chung, M.;Kim, D.S.;Chang, W.P.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.1
    • /
    • pp.266-274
    • /
    • 1996
  • An experimental work was conducted to investigate the characteristics of the onset of flooding in vertical annuli with a direct injection mode using air and water. The onset of flooding was determined by means of pressure drop measurement while the air velocity was increased gradually under fixed liquid flow rates. Data of the onset of flooding were collected for various combinations of the tube size and the nozzle number. A theoretical analysis of the onset of flooding was also performed based on an envelope theory. The result shows that the onset of flooding in small-scale annuli can be predicted relatively well by the theory. A modified Wallis parameter was used to investigate the scaling effect of flooding phenomena in the annuli, indicating a relatively reasonable result. The number of nozzle has no effect on the flooding velocity when liquid was injected through 2, 3, 4 and 6 nozzles but the initiation of flooding was significantly expedited when 12 nozzles were employed for liquid injection.

An Experimental Study on the Performance of a Cross-Flow-Type, Indirect Evaporative Cooler Made of Paper/Plastic Film (종이와 플라스틱 필름의 이종 재질로 구성된 직교류형 간접증발소자의 성능에 대한 실험적 연구)

  • Kwon, Mi-Hye;Go, Min-Geon;Kim, Nae-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.9
    • /
    • pp.475-483
    • /
    • 2015
  • In Korea, a typically hot and humid summer means that air-conditioners consume a large quantity of electricity; accordingly, the simultaneous usage of an indirect evaporative cooler may reduce the sensible-heat level and save the amount of electricity that is consumed. In this study, the heat-transfer and pressure-drop characteristics of an indirect evaporative cooler made of paper/plastic film were investigated under both dry and wet conditions; for the purpose of comparison, an indirect evaporative cooler made of plastic film was also tested. Our results show that the indirect evaporative efficiencies under a wet condition are greater than those under a dry condition, and the efficiencies of the paper/plastic sample (109% to 138%) are greater than those (67% to 89%) of the plastic sample; in addition, the wet-surface, indirect evaporative efficiencies of the paper/plastic sample are 32% to 36% greater than those of the plastic sample. Further, the wet-surface pressure drops of the paper/plastic sample are 13% to 23% larger than those of the plastic sample, and this might have been caused by the surface roughness of the samples. A rigorous heat-transfer analysis revealed that, for the plastic sample, 30% to 37% of the wet channels remained dry, whereas all of the channels were wet for the paper/plastic sample.

A study on the robust design for quality improvement of Wet Etchant manufacturing process (식각액(Wet Etchant)제조공정의 품질향상을 위한 강건설계에 대한 연구)

  • Choi, Yong-Seok;Hwang, Deock-Hyeong;Cho, Kwang-Hee;Oh, Sun-Il;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.1
    • /
    • pp.155-165
    • /
    • 2012
  • This essay talks about research of robust design for quality improvement of production procedure of Wet Etchant. It suggested the optimum design method in consideration of specific capability value that is the way to maximize the quality of product in the production system by using Daguchi parameter design method while finding factors affecting product quality with analysis of production system of product A from producer D. Also, it set long term of 6months as noise factor and let it to be the robust design that can find the optimum condition of control factor that is dull to the changes of each month, that is the change in noise factor. The control factor which affects the product quality is decided as combination method, temperature of raw material, combination time and as there are too many possibilities for combination methods, we performed 4 methods first based on previous research data then derived three ways with product that passed SPEC and set as the factor. As a result of application of optimum production procedure suggested in this essay to the actual production process with its standardization, there was a effect of drop of more than 10particles in comparison to the particle number of previous product and also it brought the effect that resulted the stable number of particle of under 30 that is what the client company suggested.

NALYSIS OF THE ECLIPSING BINARY SDSS J1021+1744: A WDMS SYSTEM WITH UNUSUAL DIPS

  • CHANTHORN, KHUNAGORN;SANGUANSAK, NUANWAN;IRAWATI, PUJI;DHILLON, VIK S.;MARSH, TOM R.
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.219-221
    • /
    • 2015
  • We present our recent observations of SDSS J102102.25+174439.9, a new eclipsing white dwarf - main sequence WDMS binary with an orbital period of 0.14 days. This system belongs to the post common-envelope binary group as shown by the spectrum from the Sloan Digital Sky Survey. We obtained our data using the ULTRASPEC instrument installed on the 2.4-m telescope at the Thai National Observatory (TNO). Our multi-band observations reveal an unusual and persistent drop in brightness after the primary eclipse. These dips, which appear to show variations in amplitude, also have a complex shape that changes within days. Dips in WDMS systems have been observed on only one other occasion, in the light curve of QS Vir prior to the eclipse of the white dwarf. The dips in SDSS J1021+1744 are unique because they are present at different wavelengths and they occur approximately at similar phases. Hosting a DA white dwarf and an M4 companion star, this system is known to be the only WDMS to show these kind of dips in its light curve. It is possible that these dips are caused by ejected materials from an active companion star, such as in QS Vir. The light curve in the g' filter exhibits deep and narrow features, implying that the material which passes in front of the white dwarf in SDSS J1021 must be dense and small in size. Furthermore, we try to constrain the stellar and orbital parameters of SDSS J1021+1744 using the Binary Maker 3 software. We use g' and r' data for our light curve analysis to have a better approximation for the red dwarf star.

Analysis of Bearing Capacity Improvement Effect of Inner Cone Penetration Equiped Open-Ended Steel Pipe Pile (개단 강관말뚝 내부 콘항타에 의한 지지력 증대효과 분석)

  • Lee, Junho;Ji, Su-Bin;Lee, Kicheol;Kim, Dongwook
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.2
    • /
    • pp.67-77
    • /
    • 2017
  • This study analyzes behavior of bearing capacity of open-ended pipe pile from laboratory experiment results. Unlike the conventional pipe piles, cone penetration is implemented into the inside of the pipe pile. During the cone penetration, cone driving energy helps densification of plugged soils and soils below the pile end. Sand pluviator was used to obtain homogeneous soil layers. Two kinds of piles with different pile outer surface roughness were prepared, and two different drop heights of pile driving were applied. Eight experimental cases varying pile outer surface roughness, pile driving energy for conventional and cone penetration implemented piles were conducted. From the experiments, ultimate load of the pile increased approximately by 70% for increased pile driving height, and it increased by 21% for rougher surface pile. When cone penetration is implemented, the ultimate load increased by 40% in average.

Calculation of the Harmonic Emission Limit for low-Voltage Electrical Equipment (국내 저압 전기기기의 고조파 유출 제한값 산정)

  • Kang, Moon-Ho;Song, Yang-Hoi;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.56-61
    • /
    • 2008
  • Because the harmonic disturbance characteristic which makes voltage drop and the deterioration of instantaneous power quality in electrical power system overheats the NGR and the customer capacitor and malfunctions the OCGR and AMR, it is necessary for electric power company to take active measures to reduce this disturbance. International Electrotechnical Commission(IEC) 61000-3-2 specifies limits for harmonic current emissions generated by low voltage(LV) electrical equipment whose input current $\leq$ 16(A) per phase. Analysis shows that limits for Class A equipment in IEC are calculated using the reference impedance of LV system and maximum permissible voltage and limits for other Classes are also calculated based on limits for Class A. Therefore we have calculated four(4) internal limits for LV electrical equipment using the korea reference impedance and maximum permissible voltage in this paper.