• Title/Summary/Keyword: Drop Landing

Search Result 97, Processing Time 0.023 seconds

The Comparative Analysis on Mechanical Property Test of Carbon Nanotube-based Shock Absorbers (탄소나노튜브를 기반으로 하는 충격흡수제의 물리적 특성 비교분석)

  • Kim, Jong-Woo;Chae, Woen-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.2
    • /
    • pp.237-242
    • /
    • 2012
  • The purpose of this study was (a) to develop carbon nanotube-based shock absorbers for reducing potentially harmful impact forces and excessive foot pronation, and (b) to briefly determine how the effects of carbon nanotube-based shock absorbers on biomechanical variance during drop landing. A university student(age: 24.0 yrs, height: 176.2 cm, weight: 679.5 N) who has no musculoskeletal disorder was recruited as the subject. Hardness, specific gravity, tensile strength, elongation, 100% modulus, tear strength, split tear strength, compression set, resilience, vertical GRF, and loading rate were determined for each material. For each dependent variable, a descriptive statistics was used for different conditions. The property test results showed that tensile strength, tear strength, split tear strength, compression set, and resilience in carbon nanotube-based shock absorbers were greater than general Ethylene Vinyl Acetate(EVA). These indicated that resistance against variable strength in developed carbon nanotube-based shock absorbers were greater than general EVA. In vertical GRF of CNTC was less than those of EVA during drop landing and loading rate of CNTC was greater than EVA. It seems that the use of CNT can be a effective way of reducing and controlling shock from impact.

Lower Extremity Movement Patterns and Variability in Adolescent Athletes with Lateral Ankle Sprain History during Drop Vertical Jump (가쪽 발목 염좌 경험이 있는 유소년 운동선수의 착지 점프 시 하지 움직임 패턴 및 가변성)

  • Sunghe Ha;Inje Lee;Joo-Nyeon Kim
    • Korean Journal of Applied Biomechanics
    • /
    • v.33 no.3
    • /
    • pp.85-93
    • /
    • 2023
  • Objective: This study examined differences in joint kinematics and movement variability of lower extremity between adolescent athletes with and without lateral ankle sprain (LAS) history during drop vertical jump. Method: Fourteen adolescent athletes with LAS history and 14 controls participated in this study. The independent variable was group while dependent variables were 3D joint kinematics and movement variability of hip, knee, and ankle joint. Ensemble curve analyses were conducted to identify differences in movement strategies between two groups. Results: The LAS group showed that greater eversion during jump phase compared with the control group. Additionally, less movement variability was found in the LAS group during the pre-landing and jump phases in ankle and hip joints compared with the control group. Conclusion: The LAS group may adapt the environmental constraints by reducing the movement variability in ankle and hip joints. However, training programs focusing on recovery of ankle function should be emphasized after LAS because excessive pronation for prevention of LAS during the jump phase may result in reduced performance.

Comparative Study on the Several Types of Double-Acting Oleo-Pneumatic Shock Absorbers of Aircraft Part II. Numerical Analysis and Comparison (항공기 올레오식 2중 완충기 종류에 따른 특성 비교 연구 Part II. 수치해석 및 비교)

  • Jeong, Seon Ho;Lee, Cheol Soon;Kim, Jeong Ho;Cho, Jin Yeon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.11
    • /
    • pp.951-966
    • /
    • 2017
  • In this work, numerical analyses are carried out and the behaviors are investigated for three types of double-acting oleo-pneumatic shock absorbers along with the mathematical models proposed in the part I of this work. After presenting each numerical algorithm corresponding to each model, the numerical algorithms are implemented as user-subroutines in MSC/ADAMS commercial multi-body dynamic software. By using the developed user-subroutines, numerical studies are carried out for compression/stretch test as well as drop test. From the comparative studies, we investigated the salient feature of each double-acting oleo-pneumatic shock absorber. Results identifies that it is possible to increase the absorbing efficiency in accordance with the requirements for aircraft landing conditions.

Effects of Wearing Spandex Pants on Impact Forces and Muscle Activities during Drop Landing (드롭 착지 동작 시 탄성 섬유 바지 착용이 충격력과 근육 활동에 미치는 영향)

  • Chae, Woen-Sik;Kang, Nyeon-Ju
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.3
    • /
    • pp.603-610
    • /
    • 2009
  • The purpose of this study was to determine how spandex pants affect impact force and muscle activities in the lower extremity. Seven pairs of surface electrodes were attached to the right-hand side of the body. Paired t-test was performed to test if significant difference exist between two conditions(p< .05). The average IEMG activities in the TA, BF, and GM during the landing phase reduced significantly with spandex pants compared to regular pants. All peak IEMG activities except the RF in wearing spandex pants group were significantly greater than the corresponding values in wearing regular pants one. The greater muscle activity recorded in wearing spandex pants can be attributed to the greater motor unit recruitment needed to decelerate and stabilized their bodies. Impact force and loading rate were not significantly decreased with wearing spandex pants. Since the spandex pants used in this study were not custom-fit based on girth of each participants thigh and shank, compression and elasticity for the pants could not be optimized.

Design of a Robust Precision Aerial Delivery System Soft Landing Algorithm (외란에 강인한 정밀공중물자수송시스템 연착륙 알고리즘 설계)

  • Kim, Taewook
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.4
    • /
    • pp.77-87
    • /
    • 2022
  • The Precision Aerial Delivery System is an instrument designed to improve the poor landing accuracy of aerial delivery system with conventional circular parachutes, and is equipped with an Airborne Guidance Unit to safely transport supplies to the desired destination. Currently, the landing accuracy of the PADS product is reported as CEP50 100m and also differs significantly, depending on the actual topography and weather environment. In this study, HILS was constructed based on the 6DOF nonlinear modeling of PADS to analyze the maneuver characteristics of Ram Air Parachute under wind environments. By using the new algorithm a precision soft landing algorithm including Energy Management and Final Approach is designed. HILS results show that it is possible to achieve a precise soft landing within CEP50 40m, and it can be exploited to develop an actual PADS drop test.

Development of a Structure for Lunar Lander Demonstrator (달착륙선 지상시험모델의 구조체 개발)

  • Son, Taek-Joon;Na, Kyung-Su;Lim, Jae Hyuk;Kim, Kyung-Won;Hwang, Do-Soon
    • Aerospace Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.213-220
    • /
    • 2013
  • Korean Lunar Explorer is planned to be launched in the 2020s according to national space development strategy. The Lunar Explorer will be developed as two unmanned light weight models: a lunar orbiter and a lunar lander. The Lunar Explorer's structure should be designed to have light weight due to constraints from launcher as well as to provide structural safety against launch load, in-orbit condition and landing condition and to serve accommodation space for mission equipment. Core technology related to structural development of lunar explorer should be developed in advance. Especially, for lunar lander, technology for developing landing gear which enables lander to land safely on lunar surface is required essentially. This paper deals with structural development of lunar lander ground test model including design, manufacturing and test.

Centrifuge modeling of dynamically penetrating anchors in sand and clay

  • An, Xiaoyu;Wang, Fei;Liang, Chao;Liu, Run
    • Geomechanics and Engineering
    • /
    • v.30 no.6
    • /
    • pp.539-549
    • /
    • 2022
  • Accidental anchor drop can cause disturbances to seabed materials and pose significant threats to the safety and serviceability of submarine structures such as pipelines. In this study, a series of anchor drop tests was carried out to investigate the penetration mechanism of a Hall anchor in sand and clay. A special anchor drop apparatus was designed to model the inflight drop of a Hall anchor. Results indicate that Coriolis acceleration was the primary cause of large horizontal offsets in sand, and earth gravity had negligible impact on the lateral movement of dropped anchors. The indued final horizontal offset was shown to increase with the elevated drop height of an anchor, and the existence of water can slow down the landing velocity of an anchor. It is also observed that water conditions had a significant effect on the influence zone caused by anchors. The vertical influence depth was over 5 m, and the influence radius was more than 3 m if the anchor had a drop height of 25 m in dry sand. In comparison, the vertical influence depth and radius reduced to less than 3 m and 2 m, respectively, when the anchor was released from 10 m height and fell into the seabed with a water depth of 15 m. It is also found that the dynamically penetrating anchors could significantly influence the earth pressure in clay. There is a non-linear increase in the measured penetration depth with kinematic energy, and the resulted maximum earth pressure increased dramatically with an increase in kinematic energy. Results from centrifuge model tests in this study provide useful insights into the penetration mechanism of a dropped anchor, which provides valuable data for design and planning of future submarine structures.

The Effects of Fibular Repositioning Taping on Joint Angle and Joint Stiffness of the Lower Extremity in Sagittal Plane during a Drop Landing (낙하 착지 시 FRT가 하지의 관절의 시상각과 강직도에 미치는 효과)

  • Jun, Hyung-pil
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.4
    • /
    • pp.276-282
    • /
    • 2021
  • Objective: To investigate effects of Fibular Repositioning Taping (FRT) on lower extremity joint stiffness and angle during drop-landing. Method: Twenty-eight participants (14 healthy, 14 with chronic ankle instability [CAI]) performed drop-landings from a 60 cm box; three were performed prior to tape application and three were performed post-FRT. Three-dimensional kinematic and kinetic data were collected using an infrared optical camera system (Vicon Motion Systems Ltd. Oxford, UK) and force-plate (AMTI, Watertown, MA). Joint stiffness and sagittal angle of the ankle, knee, and hip were analyzed. Results: The hip [Healthy: p<.05; M ± SD: 29.43 ± 11.27 (pre), 33.04 ± 12.03 (post); CAI: p<.05; M ± SD: 31.45 ± 9.70 (pre), 32.29 ± 9.85 (post)] and knee [Healthy: p<.05; M ± SD: 53.44 ± 8.09 (pre), 55.13 ± 8.36 (post); CAI: p<.05; M ± SD: 53.12 ± 8.35 (pre), 55.55 ± 9.81 (post)] joints demonstrated significant increases in sagittal angle after FRT. A significant decrease in joint angle was found at the ankle [Healthy: p<.05; M ± SD: 56.10 ± 3.71 (pre), 54.09 ± 4.31 (post); CAI: p<.05; M ± SD: 52.80 ± 6.04 (pre), 49.86 ± 10.08 (post)]. A significant decrease in hip [Healthy: p<.05; M ± SD: 1549.16 ± 517.53 (pre), 1272.48 ± 646.73 (post); CAI: p<.05; M ± SD: 1300.42 ± 595.55 (pre), 1158.27 ± 550.58 (post)] and knee [Healthy: p<.05; M ± SD: 270.12 ± 54.07 (pre), 239.13 ± 64.70 (post); CAI: p<.05; M ± SD: 241.58 ± 93.48 (pre), 214.63 ± 101.00 (post)] joint stiffness was found post-FRT application, while no difference was found at the ankle [Healthy: p>.05; M ± SD: 57.29 ± 17.04 (pre), 59.37 ± 18.30 (post); CAI: p>.05; M ± SD: 69.15 ± 17.63 (pre), 77.24 ± 35.05 (post)]. Conclusion FRT application decreased joint angle at the ankle without altering ankle joint stiffness. In contrast, decreased joint stiffness and increased joint angle was found at the hip and knee following FRT. Thus, participants utilize an altered shock absorption mechanism during drop-landings following FRT. When compared to previous research, the joint kinematics and stiffness of the lower extremity appear to be different following FRT versus traditional ankle taping.

Relationship between Neurocognitive Ability and Risk Factors of Anterior Cruciate Ligament Injuries in Female Athletes (여성선수의 신경인지 능력과 전방십자인대 손상 위험요인과의 관계)

  • Ha, Sung-He;Park, Sang-Kyoon
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.8
    • /
    • pp.301-309
    • /
    • 2018
  • The aim of this study was to investigate the relationship between the neurocognitive ability and the risk factors of non-contact anterior cruciate ligament injuries during landing in female recreational athletes. Thirty-two female athletes participated in computerized neurocognition test and motion analysis for drop vertical jump. Pearson's linear correlation analysis was performed to analyze the relationship between the raw scores of neurocognition test and biomechanical variables including 3D joint angle, moment, power, vertical ground reaction force, loading rate, and support time. There were correlations between the scores of neurocognition test and biomechanical variables as high the neurocognition score, it also increase landing strategies were used to maintain posture of the lower extremity. Therefore, the neurocognitive test might be used as a good screening method to detect the risk factors before injury.

The Effects of Knee Brace on Anterior Cruciate Ligament Injuries Risk Factors During One-Legged Landing of Female Gymnasts (여자 체조선수들의 한 발 드롭 착지 시 무릎보호대가 전방십자인대 부상 위험요인에 미치는 영향)

  • Lim, Bee-Oh;Kim, Kew-Wan;Seo, Jung-Suk
    • 한국체육학회지인문사회과학편
    • /
    • v.51 no.4
    • /
    • pp.419-425
    • /
    • 2012
  • The purpose of the study was to investigate the effects of knee brace on anterior cruciate ligament injuries risk factors during one-legged landing of female gymnasts. Eleven female gymnasts were recruited and performed randomly one-legged drop landing in height of her's knee with (3times) and without (3times) knee brace. Kinematics and ground reaction data were collected to estimate the anterior cruciate ligament injuries risk factors. Data were analyzed with paired samples t-test. Female gymnasts with knee brace showed more reduced the distance from ankle joint center to knee joint center in sagittal plane and knee maximum joint torque than without knee brace. In conclusion, Female gymnasts with knee brace reduced anterior cruciate ligament stress.