• Title/Summary/Keyword: Drinking water use

Search Result 237, Processing Time 0.022 seconds

Mathematical Model Simulations Assessing the Effects of Temperature on Residual Chlorine Concentrations in Water Storage Tanks (온도 변화에 따른 수돗물 저장 저수조 내 잔류염소에 관한 수학적 모형 시뮬레이션)

  • Noh, Yoorae;Park, Joonhong
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.2
    • /
    • pp.187-196
    • /
    • 2017
  • To ensure hygienic safety of drinking water in a water storage tank, the concentrations of residual chlorine should be above a certain regulation level. In this study, we conducted model simulations to investigate the effects of temperature on residual chlorine in water storage tank conditions typically used in Seoul. For this, values of model parameters (decomposition rate constant, sorption coefficient, and evaporation mass transfer coefficient) were experimentally determined from laboratory experiments. The model simulations under continuous flow conditions showed that the residual chlorine concentrations were satisfied the water quality standard level (0.1 mg/L) at all the temperature conditions ($5^{\circ}C$, $10^{\circ}C$, $15^{\circ}C$, $20^{\circ}C$ and $25^{\circ}C$). Meanwhile, when the tanks had a no flow condition (i.e., no tap-water influent due to a sudden shut-down), the concentrations became lower than the regulatory level after certain periods. The findings from this modeling works simulating Seoul's water storage tanks suggested disappearance rate of residual chlorine could be reduced through the tanks design optimization with maintenance of low water temperature, minimization of air flow and volume, suppression of dispersion and the use of wall materials with low sorption ability.

Treatment, Disposal and Beneficial Use Option for Sewage Sludge (하수슬러지 처리기술 동향 및 최적화 처리방안)

  • Choe, Yong-Su
    • 수도
    • /
    • v.24 no.5 s.86
    • /
    • pp.29-44
    • /
    • 1997
  • Sewage sludge produced in Korea was 1,275,800 tons (dewatered sludge cake) per year in 1996, which is 3,495 tons per day, 0.303% of 11,526,100 tons per day of sewage treated in 79 sewage treatment plants. Sludge production has been and will be increasing in accordance with construction of new facilities for sewage treatment. Most of the sludge is currently disposed by landfill and ocean dumping, but it is becoming difficult to find suitable sites for landfill, particularly in big cities such as Seoul. In addition, rapid increase of landfill cost is anticipated in a near future. Current trend for sludge disposal in advanced countries is land application. Over the past 10 to 20 years in the United States, sludge management practices have changed significantly, moving from disposal to beneficial use. They use biosolid for utilization instead of sludge for disposal. Under the Clean Water Act of 1972, amended in 1987 by Congress, the U.S. EPA was required to develop regulations for the use and disposal of sewage sludge. The EPA assessed the potential for pollutants in sewage sludge to affect public health and the environment through a number of different routes of exposure. The Agency also assessed the potential risk to human health through contamination of drinking water sources or surface water when sludge is disposed on land. The Final Rules were signed by the EPA Administrator and were published (Federal Register, 1993). These rules state that sewage sludge shall not be applied to land if the concentration of any pollutant in the sludge exceeds the ceiling concentration. In addition, the cumulative loading rate for each pollutant shall not exceed the cumulative pollutant loading rate nor should the concentration of each pollutant in the sludge exceed the monthly average concentration for the pollutant. The annual pollutant loading rate generally applies to applications of sewage sludge on agricultural lands. The most popular beneficial use of sewage sludge is land application. The sludge has to be stabilized for appling to land. One of the stabilization process for sewage sludge is lime stabilization process. The stabilization process is consisted of the stabilizing process and the drying process. Stabilization reactor can be a drum type reactor in which a crossed mixer is equipped. The additive agents are a very reactive mixture of calcium oxide and others. The stabilized sludge is dried in sun drier or rotary kiln.

  • PDF

The Removal of Arsenic from Contaminated Water using a Hybrid Membrane Process.

  • Legault, A.S.;Trembaly, A.Y.
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.06a
    • /
    • pp.93-104
    • /
    • 1997
  • The objective of this study is to develop a method to reduce arsenic concentrations in contaminated water. This work is also aimed at increasing the specificity of membrane separation processes. Arsenic in contaminated waters is often present in the form of negatively charged oxyanions. These are relatively small molecules which cannot be separated directly by ultrafiltration. Oxyanions can be captured by polyelectrolytes and separated by ultrafiltration. Results will be presented on the use of two polyelectrolytes; polyethylenimine (PEI) and poly-diallyl dimethyl ammonium chloride (DADMAC) at various feed concentrations. A semi-continuous process utilizing PEI in a circulation loop was tested. The restfits indicate that better than 99.6 % recovery (permeate concentration < 0.001 $\mu$g/L) can be achieved based on an initial arsenic concentration of 300 $\mu$g/L. The results indicate that this treatment method is suitable as a main treatment process for drinking water or a polishing step after arsenic precipitation.

  • PDF

The Use of Oyster Shell Powders for Water Quality Improvement of Lakes by Algal Blooms Removal

  • Huh, Jae-Hoon;Choi, Young-Hoon;Lee, Hyun-Jae;Choi, Woo Jeong;Ramakrishna, Chilakala;Lee, Hyoung-Woo;Lee, Shin-Haeng;Ahn, Ji-Whan
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • In this year, Koreans have a shortage in agricultural and drinking water due to severe algal blooms generated in major lakes. Waste oyster shells were obtained from temporary storage near the workplace at which oysters were separated from their shells. Heating ($1000^{\circ}C$ for 1 h in air) was employed to convert raw oyster shell powders into calcium oxide powders that reacted efficiently with phosphorus and nitrogen to remove algal blooms from eutrophicated wastewater. As the dispersed amount of heated oyster shell powders was increased, water clarity and visual light penetration were improved. Coagulation, precipitation and carbonation process of the heated oyster shell powders in a water purifier facilitated removal of eutrophication nutrient such as phosphorus and nitrogen, which is both beneficial and economically viable. $CO_2$ implantation by carbonation treatment not only produced thermodynamically stable CaO in oyster shells to derive precipitated calcium carbonate (PCC) but also accelerated algal removal by activation of coagulation and precipitation process. The use of oyster shell powders led to a mean reduction of 97% in total phosphate (T-P), a mean reduction of 91% in total nitrogen (T-N) and a maximum reduction of 51% in chemical oxygen demand (COD), compared with the total pollutant load of raw algal solution. Remarkable water quality improvement of algal removal by heated oyster shell powders and PCC carbonation treatment will allow utilization as water resources to agricultural or industrial use.

A study on the BAC pilot plant in the Duk-san water works (덕산(德山) 정수장(淨水場)에서의 BAC Pilot plant에 관한 연구(硏究))

  • Lee, Sang-Bong;Kim, Dong-Youn;Lim, Jung-A;Lee, Won-Gwon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.9 no.2
    • /
    • pp.97-107
    • /
    • 1995
  • Today a conventional water treatment system has many problems. The ozone/GAC process, sometimes termed Biological Activated Carbon(BAC), appeared to be effective for the removal of soluble organic matters in the drinking water. The water quality of Nak-dong river in Pusan, generally shows BDOC 30-40% and NBDOC 60-70%. The pilot plant installed at the Duk-san water works that was been largest treatability(1,650,000ton/day) in Pusan. A experimental water in the pilot plant made use of the water after sand-filteration. Following results are drawn from this study. Initial adsorption velocity($DOC/DOC_o/T$) in the pure adsorption of GAG had a 0.0225, it's velocity changed to 0.006 after ozone added and the optimum ozone dose ranged of $1.4-2.0mgO_3/L$. A experimental water in the pilot plant composed with humic material(78%). Humic material composed with humic acid(20%) and fulvic acid(56%), and it's rate changed to 18 and 50% respectively after ozone added. DOC constantly decreased in the EBCTs and removal efficieny in the 15min of EBCT was 45-50%. It showed the largest removal rate of BDOC in the EBCT 5 and among the season, characteristics of removal varied. The HPC distributed over $10^6-10^7CFU/cm^3$ in the bed depth and among the season, distribution of HPC were differential.

  • PDF

A Study on the Rotating Jet Nozzle for Washing Sand Filter in Water Purification Plant (정수장에서 회전 분사 노즐을 사용한 여과사 세척에 관한 연구)

  • 이주호;박승헌
    • Journal of the Korea Safety Management & Science
    • /
    • v.4 no.3
    • /
    • pp.177-187
    • /
    • 2002
  • The contamination problem is getting worse now a day because of the industrial activities. Recently it has been announced that there's environmental hormone in river and lake which produces clean water, also there's too many of algae reproduces under the water and some virus in the drinking water. The quality of water is very important. pure and clean water is not only a precondition for human being to live but a basic factor to improve the quality of life. so a water purification system must be developed. This study is about the surface washing treatment technique. We tried to use a rotary nozzle to get a tush degree of efficiency, for it was not enough with present way of washing. The nozzle is run by water pressure. The results of the experiment are as follows. We got a clean and equal surface after washing. After washing, the water's maximum consistency was 330NTU and it shows that this way is better than before one with 215NTU. Clean level of the filter was 6$^{\circ}$and it's 2.8 times higher than 17$^{\circ}$with the old way. We can see the results that the new way of washing is more effective than old way based on this study.

Study on Radioactive Material Management Plan and Environmental Analysis of Water (I) Study of Radioactive Substances in Water Management and Analysis to Eat of the US Environmental Protection Agency (Envirionmental Protection Agency) (물 환경의 방사성 물질 관리 방안과 분석법에 관한 연구 (I) 미국환경보호청(Envirionmental Protection Agency)의 먹는 물 방사성물질 관리와 분석법에 관한 고찰)

  • Her, Jae;Kim, Jung-Min;Min, Hye-Lim;Han, Seong-Gyu;Lim, Hyun-Jong;Jo, Han-Byeol;Noh, Young-Hoon;Lee, Ho-Sun;Park, Min-Suk
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.163-170
    • /
    • 2015
  • The interest of the people in the radioactive contamination of the water has increased significantly and the study about analysis and management of radioactive materials are being actively conducted. And monitoring spots have been expanded to the range of public water as well as drinking water by publishing the rule of drinking water quality standards and examination in the Environmental Enforcement Ordinance No. 553 of Korea. In this study, US EPA was investigated as the foreign advanced cases and the way that is appropriate for the Korea was sought by analyzing investigate radionuclide, interval and management. As a result, in the selection part of investigate radionuclide, geological survey, status of nuclear power plants and the presence of the use of artificial radionuclides of the Korea should be investigated and additionally after the selection of a few radionuclides, the systems should be extended to cover all possible radionuclides by considering radioactive pollution levels in humans may be exposed due to the annual drinking water. In the part of the investigate interval, the concept(MCL, DL) should be set up for preventing concentration detection of above MCL and it needs to the maintenance and management. For example, when the concentration is more than MCL, it should be investigated on a quarterly and when the concentration is lower than MCL, it should be investigated to each different interval and management. And the US EPA divided the management area and make the roadmap for managing drinking water. The each classified area has been organized to match the state budget and labor force and the individual data have been managed effectively by HPGe, the NaI, TLD and so on.

The study on the quality standards of groundwater in Korea in comparing to the developed countries (우리나라와 선진국간의 지하수 수질기준에 관한 고찰)

  • Bang, Sang-Weon;Jung, Jae-Hyun
    • Journal of Environmental Policy
    • /
    • v.4 no.2
    • /
    • pp.57-82
    • /
    • 2005
  • In this study, we propose methods for. the efficient management and integrity of groundwater in response to a diminishing supply. As an alternative water resource for the future. we investigated and comparatively analyzed the quality standards of groundwater in the US (New York, Wisconsin and Texas), Austria, Netherlands, Canada, Japan and United Kingdom. These developed countries heavily depend on groundwater, more than 70%, for drinking water and apply those drinking water standards to groundwater quality. However, there exists few differences in the quality standards of groundwater among the countries, because each country possesses its own individual environment and management. In Korea, surface water pollution is getting serious and its water resources are diminishing. Therefore we propose several new quality criteria that many countries regulate at these days for their efficient management of groundwater. There is a need to divide BTEX criterion into Benzene, Toluene, Ethylbenzene and Xylene, individually. In. addition, it is needed to establish BTEX criteria into agricultural water and industrial water use standards as well as daily life use standards. Also, regulations for some PAHs, showing carcinogenicity, are required. Due to rapid industrialization various hazardous chemicals were utilized and their uses are increasing each year. Therefore, there is a strong need to introduce n~w standards and tighter regulations of the levels. At the same time, the criterion of nitrogenous compounds need' to be regulated individually in order to prevent the damage incurred by the compounds. Several developed countries have established standards for radon, previously caused environmental accidents in Korea. Therefore, we propose the necessity of groundwater quality standards for radon in this study.

  • PDF

The Effects of Timber Harvesting on Soil Chemical Ingredients and Stream Water Quality (성숙임목수확벌채가 토양의 화학성분과 계류수질에 미치는 영향)

  • 박재현;우보명;김우룡;안현철;김재수
    • The Korean Journal of Ecology
    • /
    • v.23 no.1
    • /
    • pp.9-15
    • /
    • 2000
  • The effects of clearcutting on soil chemical ingredients and stream water quality have been investigated at a natural deciduous forest catchment within the Seoul National University Research Forest in Mt. Paekun, Chunnam province during the periods of 1993 to 1998. Soil chemical ingredients and stream water qualities were monitored at a 13 ha clearcutting site and a non-treatment site nearby. During the first and second years after harvesting, the levels of total-N, and exchangeable ions (K/sup +/, Na/sup +/, Ca/sup 2+/, Mg/sup 2+/) decreased compared to the values of before harvesting. During the fifth years after harvesting, these levels were significantly higher than those during the first and second years after harvesting. But the chemical characteristics of soil were not changed at all. pH of water in the harvesting area was 6.5 in stream water. Among the nutrients, Cd, Pb, Cu, and phosphate were not found, and the level of BOD reached at the level of the domestic use suitable for drinking. Turbidity, odor, taste, NH/sub 4//sup +/ -N, NO/sub 3//sup -/-N, standard plate count, and coliform were also low enough to be used as the domestic use for drinking by the near villagers. During the first and second years after harvesting, BOD increased to about 1 ppm. For that reason, the harvesting planning should be built in the harvesting area in consideration of the control of water quality in the stream.

  • PDF

The PWM Control Which used Microprocessor for Intensity Control of Acid Ion Water (산성이온수 농도제어를 위한 Microprocessor를 이용한 PWM 제어)

  • Kwon, Yunjung;Nam, Sangyep
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.7
    • /
    • pp.269-274
    • /
    • 2013
  • We are used with the alkaline ion water which an application field does to object for drinking water compare with the alkaline ion water which asked ion acid electrolysis so as to be very different. This is used with sterilization disinfection use by residual chlorine in case of strong acidity according to ph intensity, and in case of middle acidity use by washing and face washing, and mix with meal materials in case of weak acidity widely usable in cooking. Acid ion water generates as we electrolyze water. Chlorine gas and sodium hydroxide etc. was generated at electrolysis process, and we have toward sterilizing power. Derelicts such as chlorine, phosphorus, sulfur etc. are gathered from a negative ion, and we make acid ion water to + electrode direction in electrolysis. We used a diaphragm in order to disconnect too acid water and alkaline water. We implemented so that the acid water which it came down to three kinds of PWM voltage to PWM (pulse width modulation) control, and implementation method of ph intensity change authorized ph intensity between weak acidity to electrode in strong acidity as we used Microprocessor, and intensity was adjusted successively by PWM control was generated.