• 제목/요약/키워드: Drinking, Residual

검색결과 112건 처리시간 0.027초

Formation of Assimilable Organic Carbon from Algogenic Organic Matter

  • Kim, Ji-Hoon;Chung, Soon-Hyung;Lee, Jing-Yeon;Kim, In-Hwan;Lee, Tae-Ho;Kim, Young-Ju
    • Environmental Engineering Research
    • /
    • 제15권1호
    • /
    • pp.9-14
    • /
    • 2010
  • The objective of this study was to assess the variation in the concentration of assimilable organic carbon (AOC) in a drinking water resource, and investigate the characteristics of AOC derived from algae. The seasonal change in AOC at the Kamafusa dam corresponded to changes in the algal cell number. In order to understand the relationship between AOC and algae in a water resource and water purification plant, two kinds of laboratory experiment were performed. The algal culture experiment showed that extracellular organic matter (EOM) that was released during the growth of Phormidium tenue with M-11 medium led to significant increases in the AOC concentration, but no significant variation in the AOC concentration was observed with CT medium containing a high dissolved organic carbon concentration. The chlorination experiment showed that the AOC included in EOM was not easily removed by chlorination, although the AOC included in intercellular organic matter released from the algal cells by chlorination was removed under conditions where residual chlorine was detected.

Fungal Load of Groundwater Systems in Geographically Segregated Islands: A Step Forward in Fungal Control

  • Joong Hee Cho;Nam Soo Jun;Jong Myong Park;Ki In Bang;Ji Won Hong
    • Mycobiology
    • /
    • 제50권5호
    • /
    • pp.345-356
    • /
    • 2022
  • The fungal distribution, diversity, and load were analyzed in the geographically segregated island groundwater systems in Korea. A total of 79 fungal isolates were secured from seven islands and identified based on the internal transcribed spacer (ITS) sequences. They belonged to three phyla (Ascomycota, Basidiomycota, and Chlorophyta), five classes, sixteen orders, twenty-two families, and thirty-one genera. The dominant phylum was Ascomycota (91.1%), with most fungi belonging to the Cladosporium (21.5%), Aspergillus (15.2%), and Stachybotrys (8.9%) genera. Cladosporium showed higher dominance and diversity, being widely distributed throughout the geographically segregated groundwater systems. Based on the diversity indices, the genera richness (4.821) and diversity (2.550) were the highest in the groundwater system of the largest scale. As turbidity (0.064-0.462) increased, the overall fungal count increased and the residual chlorine (0.089-0.308) had low relevance compared with the total count and fungal diversity. Cladosporium showed normal mycelial growth in de-chlorinated sterilized samples. Overall, if turbidity increases under higher fungal diversity, bio-deterioration in groundwater-supplying facilities and public health problems could be intensified, regardless of chlorine treatment. In addition to fungal indicators and analyzing methods, physical hydrostatic treatment is necessary for monitoring and controlling fungal contamination.

페광산 복구지역 잔류장미로 인한 주변 지하수${\cdot}$토양 오염가능성-시흥광산 사례 (Potential Contamination of Soil and Groundwater from the Residual Mine Tailings in the Restored Abandoned Mine Area : Shihung Mine Area)

  • 정예진;이상훈
    • 자원환경지질
    • /
    • 제34권5호
    • /
    • pp.461-470
    • /
    • 2001
  • 시흥광산은 1973년 폐장되었으며 1990년 초에 선광장 및 광미야적장에 있던 광미들을 제거한 후 그 자리에 소각장을 건설하는 폐광 복원사업을 실시하였다. 그러나 현재에도 광미가 완전히 제거되지 않았으며 광산 가동기간동안 많은 양의 광미가 주변 토양 및 논으로 이동, 퇴적된 것이 확인되는 바 광미와 물 반응으로 인한 침출수 형성과 주변 지하수 토양의 중금속 오염이 예상된다. 된 연구는 잔류광미와 물 반응에 따른 광산배수의 지구화학적 진화과정을 분석하고 주변 지하수 · 토양 오염 가능성을 평가하고자 하였다. 광미에서 추출한 공극수는 깊이에 따라 그 농도가 증가함을 보여 광미-불 반응을 통하여 지속적으로 중금속이 용출됨을 시사한다. 광미 중금속 용출은 공극수뿐 아니라 표면과 심부에서 각자 채취한 광미시료들간의 화학성분 차이에서도 확인된다. 광산 배수 기원지역과 하부 지역의 지하수 시료를 거리에 따라 채취, 분석한 결과 Cd, Pb 및 Zn 등은 국내 및 미국환경청 음용수 기준을 초과하며 광산배수의 영향을 받은 결과로 해석된다. 실내 회분식 시험 결과 원소들은 농도가 급격히 감소하는 것과 비교적 일정한 농도를 보이는 두 가지 양상을 보였으며 이는 일부 원소들이 평형농도에 도달하고 있기 때문으로 생각된다 회분식 시험에 사용한 증류수의 평균 pH는 6.5∼7.0의 범위로 이를 pH 4로 조정한 결과 원소들의 용출량이 급격히 증가하였다. 본 지역의 잔류광미는 지속적으로 주변의 지하수와 토양을 오염시킬 것으로 판단되며 이는 산성비등의 영향으로 인하여 급격히 증가할 것이다.

  • PDF

차를 이용한 수돗물 간접 음용시 수돗물 중 미네랄 함량 변화 연구 (Study on the Changes of the Mineral Contents in Tap-water Drinking with Diverse Teas)

  • 김정희;류리나;송대성;이정엽;이영주
    • 대한환경공학회지
    • /
    • 제37권9호
    • /
    • pp.511-516
    • /
    • 2015
  • 본 연구에서는 수돗물을 끓이는 과정에서의 잔류염소와 소독부산물 제거 특성과 더불어 차를 이용하여 끓였을 때 인체 필수 미네랄 성분의 용출특성에 대해 조사하였다. 현재까지 대부분의 연구가 차를 이용하여 끓였을 때 유해 중금속의 흡착 제거에 초점을 맞추었다면, 본 연구에서는 차를 이용하여 끓였을 때 인체 필수 미네랄 성분의 용출특성에 대해 조사함으로써 보다 건강하고 안전하게 수돗물을 음용하는 방법에 대해 제언하고자 하였다. 조사결과 잔류염소농도 0.7 mg/L 수돗물을 약 20분 가열시 모두 제거되었으며, 소독부산물(THMs, HAAs, CH) 농도는 65%까지 감소하였다. 시판 차 5종(옥수수, 보리, 둥굴레, 현미, 결명자)을 이용하여 끓였을 때 인체 필수 미네랄 6종(칼슘, 칼륨, 나트륨, 마그네슘, 황, 인)의 단위중량당용출량 총합은 결명자차가 최대 9.6 mg/g으로 가장 높았으며, 현미차의 용출량은 1.6 mg/g으로 상대적으로 낮았다. 특히 다른 미네랄에 비해 체내에서 정상혈압유지, 세포물질대사, 효소작용 등 중요역할을 담당하는 칼륨의 용출량이 상대적으로 높은 것으로 조사되었다. 또한 차를 이용하여 수돗물을 끓여 마시는 것만으로도 일부 미네랄성분은 한국인 영양권고 섭취량의 최대 40%까지 섭취 가능한 것으로 조사되었다.

pH 변화에 따른 클로라민 생성과 분해 특성 (The characteristics of chloramine formation and decay with pH variation)

  • 조관형;김평청;우달식;조영태
    • 한국환경과학회지
    • /
    • 제11권4호
    • /
    • pp.347-353
    • /
    • 2002
  • 본 연구의 시료는 현재 서울특별시와 수도권 도시들에서 상수원수로 이용하고 있는 한강수를 대상으로 수행되었다. 배ㆍ급수계통의 2차 소독을 위한 클로라민소독의 특성에 관하여 고찰하였으며 그 결과는 다음과 같다. 1) $25^{\circ}C$, Cl$_2$ / NH$_3$-N비 1:1 ~ 14:1에서 PH6, 7, 8의 불연속점은 각각 Cl$_2$ / NH$_3$-N비 11:1, 9:1, 10:1이었다. pH6의 경우, Cl$_2$ / NH$_3$-N비가 9:1일 때 총 잔류염소량이 최대인 반면, pH 7, 8의 경우 Cl$_2$ / NH$_3$-N비가 각각 6:1, 5:1 일 때 최대가 되었다. 2) pH가 6, 7, 8로 증가함에 따라 모노클로라민이 최대로 생성되는 Cl$_2$ / NH$_3$-N비는 7:1에서 5:1로 이동하였으며, pH6 ~ 8 범위에서 pH가 증가함에 따라 모노클로라민의 생성량이 많았다. 3) 클로라민의 분해는 Cl$_2$ / NH$_3$-N비가 증가하고 pH가 낮을수록 증가하였다. 클로라민의 잔류성은 유리염소보다 월등히 좋았다. pH6에서 모노클로라민과 디클로라민이 생성된 이후, 접촉시간이 경과함에 따라 디클로라민의 분포비가 증가하였다.

Removal of residual VOCs in a collection chamber using decompression for analysis of large volatile sample

  • Lee, In-Ho;Byun, Chang Kyu;Eum, Chul Hun;Kim, Taewook;Lee, Sam-Keun
    • 분석과학
    • /
    • 제34권1호
    • /
    • pp.23-35
    • /
    • 2021
  • In order to measure the volatile organic compounds (VOCs) of a sample which is too large to use commercially available chamber, a stainless steel vacuum chamber (VC) (with an internal diameter of 205 mm and a height of 50 mm) was manufactured and the temperature of the chamber was controlled using an oven. After concentrating the volatiles of the sample in the chamber by helium gas, it was made possible to remove residual volatile substances present in the chamber under reduced pressure ((2 ± 1) × 10-2 mmHg). The chamber was connected to a purge & trap (P&T) using a 6 port valve to concentrate the VOCs, which were analyzed by gas chromatography-mass spectrometry (GC-MS) after thermal desorption (VC-P&T-GC-MS). Using toluene, the toluene recovery rate of this device was 85 ± 2 %, reproducibility was 5 ± 2 %, and the detection limit was 0.01 ng L-1. The method of removing VOCs remaining in the chamber with helium and the method of removing those with reduced pressure was compared using Korean drinking water regulation (KDWR) VOC Mix A (5 μL of 100 ㎍ mL-1) and butylated hydroxytoluene (BHT, 2 μL of 500 ㎍ mL-1). In case of using helium, which requires a large amount of gas and time, reduced pressure ((2 ± 1) × 10-2 mmHg) only during the GC-MS running time, could remove VOCs and BHT to less than 0.1 % of the original injection concentration. As a result of analyzing volatile substances using VC-P&T-GC-MS of six types of cell phone case, BHT was detected in four types and quantitatively analyzed. Maintaining the chamber at reduced pressure during the GC-MS analysis time eliminated memory effect and did not affect the next sample analysis. The volatile substances in a cell phone case were also analyzed by dynamic headspace (HT3) and GC-MS, and the results of the analysis were compared with those of VC-P&T-GC-MS. Considering the chamber volume and sample weight, the VC-P&T configuration was able to collect volatile substances more efficiently than the HT3. The VC-P&T-GC-MS system is believed to be useful for VOCs measurement of inhomogeneous large sample or devices used inside clean rooms.

원수 pH 조정에 의한 정수 수질 개선 (Improvement of Quality in Treated Water by the pH Adjustment of Raw Water)

  • 정관조;이경우;김현희;정의선;박현;한선희
    • 대한환경공학회지
    • /
    • 제32권5호
    • /
    • pp.469-476
    • /
    • 2010
  • 상수원수의 특성 변화와 갈수기 조류 발생으로 인한 원수 pH 상승 시기에 이산화탄소($CO_2$)를 주입하여 원수 pH를 조정함으로써 혼화·응집지의 응집 효율을 향상시켜 생산 정수 중의 잔류알루미늄, 탁도, 입자수 등의 농도를 낮추는 방법을 조사하고자 본 연구를 실시하였다. 원수 pH 8.0 이상이며 밤 낮의 pH 변화가 크지 않은 2월, 3월, 4월, 12월 중에 이산화탄소 주입 전 후의 정수 수질 변화를 고찰하였으며, 정수처리 공정수를 대상으로 정수 수질평가와 밀접한 관련이 있는 알루미늄, 탁도, 입자수, TOC, THMs, 2-MIB, geosmin 등의 농도 변화를 조사하였다. 조사결과, 혼화 응집지의 응집 효율 향상으로 입자수, 탁도, 알루미늄과 같은 입자성 물질과 무기물질은 감소하였으며 서울시 정수 목표수질값인 입자수 30개/mL 이하, 탁도 0.05 NTU 이하, 알루미늄 0.02 mg/L 이하의 양호한 정수 수질을 유지하기 위해서는 원수 pH 상승시기 이산화탄소를 주입하여 착수정원수 pH를 7.4 이하로 유지해야 하는 것으로 나타났다. 또한 THMs, CH, HAAs, HANs 등 소독부산물과 이취미 유발물질인 2-MIB, geosmin 농도는 원수 pH 변화와 무관함을 알 수 있었으며, 특히 이취미 유발물질인 2-MIB, geosmin는 pH 변화보다는 원수 중의 2-MIB, geosmin 농도가 정수 중의 농도 결정에 주요한 영향을 주는 것으로 나타났다.

CO2 주입에 의한 pH 조정이 정수장 응집효율 및 알루미늄 용출에 미치는 영향 (Effect of pH Adjustment by CO2 on Coagulation and Aluminum Elution in Water Treatment)

  • 이길성;김민채;권재국;서규태
    • 대한환경공학회지
    • /
    • 제35권1호
    • /
    • pp.17-22
    • /
    • 2013
  • 본 연구는 조류 개체 수 증가로 pH가 급격하게 상승한 원수가 정수장으로 유입될 때 pH 조정을 위해 사용하는 이산화탄소($CO_2$) 주입이 응집효율 및 용존 알루미늄 농도변화에 미치는 영향을 고찰하였다. 응집제 1 mg/L에 주입에 따른 pH 감소는 LAS -0.0384, PAC -0.0254, A-PAC -0.0201, PACS2 -0.0135로 나타났다. 용존 알루미늄 농도는 pH 7.44에서 0.02 mg/L, pH 7.96에서 0.07 mg/L, pH 8.16에서 0.12 mg/L, pH 8.38에서 0.39 mg/L로 응집공정의 pH 증가에 따라 용존 알루미늄 농도가 증가하는 것으로 나타났다. 여기서 주목할 점은 급속 교반 후 pH 8.0을 초과할 때부터 용존 알루미늄 농도는 급격하게 증가하는 것이다. 그러므로 높은 pH의 원수가 유입되는 정수장에서 알루미늄 농도가 먹는 물 수질 기준 만족하기 위해서는 응집공정의 pH가 7.8 이하로 유지되도록 공정관리가 필요하며, 원수 pH가 8.0 이상 유입되는 경우 이산화탄소($CO_2$) 주입으로 pH를 7.3 내외로 일정하게 유지할 수 있었다. 또한 이산화탄소($CO_2$) 주입으로 응집공정에서 pH를 조정함으로써 탁도 및 응집제 절감, 용존 알루미늄 농도 감소 효과를 확인할 수 있었다.

정수처리에서 염수요구량 및 반응거동에 관한 연구 (Evaluation of Chlorine Demand and Chlorine Decay Kinetics for Drinking Water)

  • 이윤진;조관형;최종헌;명복태;남상호
    • 한국환경보건학회지
    • /
    • 제27권1호
    • /
    • pp.27-35
    • /
    • 2001
  • This aim of the work presented in this paper is to investigate the factors that affcet chlorine decay and to develop functional relationships that can be used to enhance the durability of network models. predictive relationships were established that correlated the rate of chlorine decay to the various water conditions such as DOC, N $H_3$-N, initial chlorine, contact time, temperature and pH values. Free chlorine residual decreased with increasing temperature, DOC, N $H_3$-N, reaction time and chlorine dose. At 2$0^{\circ}C$, pH 7, The initial chlorine demand per mg as DOC/L and mg as N $H_3$-N/L was about 0.43, 2.69 mg/$\ell$ respectively at 180 minutes contact time. The Reaction between chlorine and humic acids was lasted intil 48hr, but the reaction between chlorine and N $H_3$-N was almost completed in 180 min. When the temperature is raised by 1$0^{\circ}C$, chlorine is more consumed about 0.25 mg/$\ell$ in the absence of organic substances and it is more consumed about 3.4 mg/$\ell$ in the presence of humic acid (5 mg/$\ell$) in water at pH 7 for 180 min. Regression Analysis created the resulting prediction equation for the chlorine decay in a SPSS package of the computer system. The model is as follows; $C_{t}$=1.239+0.707(Co)-0.000529(Time)-0.0112(Temp)+0.02227(pH)-0.42(DOC)-2.132(N $H_3$-N).).

  • PDF

수질오염 감시체계 구축을 위한 수질 데이터의 통계적 예측 가능성 검토 (A Study on the Statistical Predictability of Drinking Water Qualities for Contamination Warning System)

  • 박노석;이영주;채선하;윤석민
    • 상하수도학회지
    • /
    • 제29권4호
    • /
    • pp.469-479
    • /
    • 2015
  • This study have been conducted to analyze the feasibility of establishing Contamination Warning System(CWS) that is capable of monitoring early natural or intentional water quality accidents, and providing active and quick responses for domestic C_water supply system. In order to evaluate the water quality data set, pH, turbidity and free residual chlorine concentration data were collected and each statistical value(mean, variation, range) was calculated, then the seasonal variability of those were analyzed using the independent t-test. From the results of analyzing the distribution of outliers in the measurement data using a high-pass filter, it could be confirmed that a lot of lower outliers appeared due to data missing. In addition, linear filter model based on autoregressive model(AR(1) and AR(2)) was applied for the state estimation of each water quality data set. From the results of analyzing the variability of the autocorrelation coefficient structure according to the change of window size(6hours~48hours), at least the window size longer than 12hours should be necessary for estimating the state of water quality data satisfactorily.