• Title/Summary/Keyword: Drain Rate

Search Result 187, Processing Time 0.027 seconds

Design and Development of Integrated Recirculating Aquaculture System (순환 여과식 양식 시스템의 설계 및 개발)

  • SUH Kuen-Hack;KIM Byong-Jin;JEON Im Gi
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.34 no.1
    • /
    • pp.70-76
    • /
    • 2001
  • An integrated recirculating aquaculture system suitable to our country's situation was designes and developed, The integrated recirculating aquaculture system consisting of a double drain type rearing tank of the $2.5 m^3$, a sedimentation tank for removal of settleable solids, a floating bead filter for the removal of suspended solids, a foam separator for removal of fine particles and a rotating biological contactor for the nitrification was designed and manufactured. The integrated recirculating aquaculture system was stocked with nile tilapia (Oreochromis niloticus) at $2\%$ rearing density for 2 weeks. Feed coefficient was 1.4 and average daily growth rate was $0.64\%$ in the system for 2 weeks.

  • PDF

Prediction of Daily Water Supply Using Neuro Genetic Hybrid Model (뉴로 유전자 결합모형을 이용한 상수도 1일 급수량 예측)

  • Rhee, Kyoung-Hoon;Kang, Il-Hwan;Moon, Byoung-Seok;Park, Jin-Geum
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.4
    • /
    • pp.157-164
    • /
    • 2005
  • Existing models that predict of Daily water supply include statistical models and neural network model. The neural network model was more effective than the statistical models. Only neural network model, which predict of Daily water supply, is focused on estimation of the operational control. Neural network model takes long learning time and gets into local minimum. This study proposes Neuro Genetic hybrid model which a combination of genetic algorithm and neural network. Hybrid model makes up for neural network's shortcomings. In this study, the amount of supply, the mean temperature and the population of the area supplied with water are use for neural network's learning patterns for prediction. RMSE(Root Mean Square Error) is used for a MOE(Measure Of Effectiveness). The comparison of the two models showed that the predicting capability of Hybrid model is more effective than that of neural network model. The proposed hybrid model is able to predict of Daily water, thus it can apply real time estimation of operational control of water works and water drain pipes. Proposed models include accidental cases such as a suspension of water supply. The maximum error rate between the estimation of the model and the actual measurement was 11.81% and the average error was lower than 1.76%. The model is expected to be a real-time estimation of the operational control of water works and water/drain pipes.

Analysis of Threshold Voltage Characteristics for Double Gate MOSFET Based on Scaling Theory (스켈링이론에 따른 DGMOSFET의 문턱전압 특성분석)

  • Jung, Hak-Kee;Han, Ji-Hyung;Jeong, Dong-Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.683-685
    • /
    • 2012
  • This paper have presented the analysis of the change for threshold voltage and drain induced barrier lowering among short channel effects occurred in subthreshold region for double gate(DG) MOSFET with two gates to be next-generation devices, based on scaling theory. To obtain the analytical solution of Poisson's equation, Gaussian function been used as carrier distribution to analyze closely for experimental results, and the threshold characteristics have been analyzed for device parameters such as channel thickness and doping concentration and projected range and standard projected deviation of Gaussian function. Since this potential model has been verified in the previous papers, we have used this model to analyze the threshold chatacteristics. As a result to apply scaling theory, we know the threshold voltage and drain induced barrier lowering is changed, and the deviation rate is changed for device parameters for DGMOSFET.

  • PDF

Consolidation Characteristics of Soft Ground with Artesian Pressure (피압에 따른 연약지반의 압밀 거동)

  • Yun, Daeho;Kim, Jaehong;Kim, Yuntae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.2
    • /
    • pp.31-39
    • /
    • 2016
  • Vertical drain has usually been used to accelerate the consolidation of soft clay deposits with high moisture content. Busan thick clay deposits are subjected to artesian pressure from an aquifer in sand and gravel layers. However, effect of artesian pressure existing in drainage-installed soft ground on consolidation behaviors is not well known. This paper investigates the consolidation behavior of drainage-installed soft ground at the Nakdong river estuary with artesian pressure and without artesian pressure. A series of one-dimensional large size column test was carried out to find out the consolidation characteristics of clay. Test results indicated that total settlement of clay with artesian pressure was higher than that without artesian pressure because effective stress decreased due to upward flow. Dissipation rate of excess pore water pressure delayed and excess pore water pressure did not fully dissipate in clay layer with artesian pressure. Undrained shear strength of clay ground with artesian pressure was lower than that without artesian pressure.

Axisymmetric Nonlinear Consolidation Analysis for Drainage-installed Deposit Considering Secondary Compression (배수재가 설치된 연약지반의 2차압축을 고려한 축대칭 비선형 압밀해석)

  • Kim Yun-Tae
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.3
    • /
    • pp.133-140
    • /
    • 2005
  • In order to accelerate the rate of consolidation settlement and gain a required shear strength for a given soft clay deposit, vertical drain method combined with a preloading technique has been widely applied. In this paper, a theory of axisymmetric nonlinear consolidation fer drainage-installed deposit, which considers secondary compression (or creep) during primary consolidation, as well as the variations of compressibility and permeability during the consolidation process, has been developed. A computer program named AXICON based on Hypothesis B fur the analysis of axisymmetric nonlinear consolidation was developed by adopting finite difference method. The results of AS(ICON were compared with Hansbo's solution based on Hypothesis A, as well as in-situ settlements and pore pressures measured in test embankment of Ska-Edeby. The results indicated that Hypothesis A usually underestimated the in-situ settlement and Hypothesis B was considered to be logically correct. It was also shown that one may able to appropriately predict the real in-situ behaviors using the proposed program.

Improvement of Rapid Sand Filtration to Two Stage Dual Media Filtration System in Water Treatment Plant (정수처리장내 급속모래 여과지의 이단복합여과시스템으로의 개량)

  • Woo, Dal-Sik;Hwang, Kyu-Won;Kim, Joon-Eon;Hwang, Byung-Gi;Jo, Kwan-Hyung
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.2
    • /
    • pp.141-149
    • /
    • 2011
  • This study aimed for developing a two stage dual media filtration system. It has a sand and activated carbon layer above the under-drain system, and a sand layer above the middle-drain system for pretreatment. When retrofitting an old sand filter bed or designing a new one, this technology can substitute the existing sand filter bed without requiring a new plant site. The removal rate of total particle is 93, and 3~7 ${\mu}m$ and 5~15 ${\mu}m$ particles are all 97%. These high removal efficiencies of each pollutant due to adsorption and biological oxidation in activated carbon filter layer. The best backwashing method of two stage dual media filtration system is ascertained by air injection, air + water injection and water injection sequence. In this study, a pilot plant of two stage and dual filtration system was operated for 4 months in water treatment plant. The stability of turbidity was maintained below 1 NTU. The TOC, THMFP and HAAFP were removed about 90% by two stage and dual media filtration system, which is almost 2 times higher than existing water treatment plant.

An 8b 200MHz Time-Interleaved Subranging ADC With a New Reference Voltage Switching Scheme (새로운 기준 전압 인가 방법을 사용하는 8b 200MHz 시간 공유 서브레인징 ADC)

  • Moon, Jung-Woong;Yang, Hee-Suk;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.4
    • /
    • pp.25-35
    • /
    • 2002
  • This work describes an 8b 200MHz time-interleaved subranging analog-to-digital converter (ADC) based on a single-poly digital CMOS process. Two fine ADCs for lower digital bits of the proposed ADC employ a time-sharing double-channel architecture to increase system speed and a new reference voltage switching scheme to reduce settling time of the reference voltages and chip area. The proposed intermeshed resistor string, which generates reference voltages for fine ADCs, improves linearity and settling time of the reference voltages simultaneously. The proposed sample- and-hold amplifier(SHA) is based on a highly linear common-drain amplifier and passive differential circuits to minimize power consumption and chip area with 8b accuracy and employs input dynamic common mode feedback circuits for high dynamic performance at a 200MHz sampling rate. A new encoding circuit in a coarse ADC simplifies the signal processing between the coarse ADC and two successive fine ADCs.

A Study on Rain Gutters with Coanda Effect (코안다효과가 적용된 빗물받이에 관한 연구)

  • Jung, Yong Sin;Kim, Yong Sun;Shin, Hee Jae;Ko, Sang Cheol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.4
    • /
    • pp.58-64
    • /
    • 2020
  • Large-scale flooding due to extreme weather and typhoons causes heavy damage. This is especially true in urban areas where accumulated debris prevents the smooth drainage of rainwater in sewage facilities such as rain gutters installed near roads. In this study, to improve the drainage performance and effectively remove foreign substances by applying the dust screen used in rivers, the rain gutter with Coanda effect was simulated and compared with the experiment. The simulation was performed by setting the parameters to the fillet radius R1 and R2 at the top of the screen filter, the fillet radius R3 at the bottom of the screen filter, and the height H of the gap W from the bottom. W is the gap at the backside of screen filter which is applied to stimulate the Coanda effect. According to the simulation results, the highest drain performance was 87.99% derived from R1= 30mm, R2= 5mm, R3= 85mm, H= 75mm, and W= 2mm. The error rate of simulation results refer to the 4.89%~7.36% compared to the experimental results. In the future, by considering the slope according to the installation environment, the simulation results can be applied to the actual roadside to help prevent flood damage.

A Study on the Evaluation Criteria of Drainage Performance by Measurement of Horizontal Drainage Flow Rate by Damage Degree by Interior Model Construction Experiment (실내 모형토조실험에 의한 손상도별 수평배수공 유출량 측정을 통한 배수성능 평가 기준 제안)

  • Suhwan Choi;Donghyuk Lee;Jeonghoon Shim
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.1
    • /
    • pp.45-50
    • /
    • 2023
  • In order to prevent slope disasters caused by rainfall, it is very important to quickly exclude rainfall. In Korea, horizontal drainage holes with excellent economic feasibility and construction performance are generally applied as a method to lower the underground water level. However, horizontal drainage holes constructed on the site are often uniformly constructed regardless of the presence or absence of other water or ground conditions, and it is often difficult to expect drainage performance of horizontal drainage holes due to poor maintenance. In this study, an artificial ground was created using model construction and horizontal drainage experiments were conducted to measure the amount of horizontal drainage drain in a certain amount of control area 0%, 25%, 50%, 75%, and an evaluation table (draft) that can quantitatively evaluate horizontal drainage based on measurements and design documents is proposed as basic data.

Numerical analysis of vertical drains accelerated consolidation considering combined soil disturbance and visco-plastic behaviour

  • Azari, Babak;Fatahi, Behzad;Khabbaz, Hadi
    • Geomechanics and Engineering
    • /
    • v.8 no.2
    • /
    • pp.187-220
    • /
    • 2015
  • Soil disturbance induced by installation of mandrel driven vertical drains decreases the in situ horizontal hydraulic conductivity of the soil in the vicinity of the drains, decelerating the consolidation rate. According to available literature, several different profiles for the hydraulic conductivity variation with the radial distance from the vertical drain, influencing the excess pore water pressure dissipation rate, have been identified. In addition, it is well known that the visco-plastic properties of the soil also influence the excess pore water pressure dissipation rate and consequently the settlement rate. In this study, a numerical solution adopting an elastic visco-plastic model with nonlinear creep function incorporated in the consolidation equations has been developed to investigate the effects of disturbed zone properties on the time dependent behaviour of soft soil deposits improved with vertical drains and preloading. The employed elastic visco-plastic model is based on the framework of the modified Cam-Clay model capturing soil creep during excess pore water pressure dissipation. Besides, nonlinear variations of creep coefficient with stress and time and permeability variations during the consolidation process are considered. The predicted results have been compared with V$\ddot{a}$sby test fill measurements. According to the results, different variations of the hydraulic conductivity profile in the disturbed zone result in varying excess pore water pressure dissipation rate and consequently varying the effective vertical stresses in the soil profile. Thus, the creep coefficient and the creep strain limit are notably influenced resulting in significant changes in the predicted settlement rate.