• Title/Summary/Keyword: Drain Rate

Search Result 187, Processing Time 0.024 seconds

An experimental study on the improvement of tunnel drainage system using a geogrid composite (지오그리드 복합 배수재를 이용한 터널 배수성능 개선에 관한 실험적 연구)

  • Lee, Jun S.;Choi, Il-yoon;Lim, Jihoon;Yoon, Suk Chul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.1
    • /
    • pp.31-40
    • /
    • 2016
  • A new testing equipment is designed to investigate the characteristics of the drainage fabric which is used in the tunnel drain system. The equipment is possible to model the loading as well as boundary conditions of the shotcrete precisely and it follows the general guideline of ASTM D4716 so that the interface between shotcrete and concrete lining retains the real situation in the tunnel site. Using the real loading conditions and surface irregularities, the flow rate and its capacity of the regular fabric has been estimated. A composite drainage fabric having geogrid inside was also used to investigate the flow rate and its efficiency. The advantages of the composite fabric compared with the regular one have been demonstrated using the experimental data and brief outline of the future work is finally proposed.

Advantages of Intra-Articular Tranexamic Acid Injection Following Simultaneous Bilateral Primary Total Knee Arthroplasty (퇴행성 관절염 환자에게 동시에 시행하는 양측 인공 슬관절 전치환술에서 관절강 내 Tranexamic Acid 주입의 장점)

  • Park, Hyung seok;Kim, Dong hwi;Lee, Gwang chul;Lim, Jae hwan;Lim, Dong seop;Lee, Jung ho
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.504-511
    • /
    • 2021
  • Purpose: This study examined the difference between the drainage volume, blood loss, transfusion rate, volume, and complications with or without an intra-articular (IA) tranexamic acid (TXA) injection among patients who underwent simultaneous bilateral total knee arthroplasty (SBTKA) with bilateral knee joint osteoarthritis, including patients who have contraindications of intravenous administration. Materials and Methods: Among patients who underwent SBTKA from April 2016 to December 2018, 139 patients injected with 3 g of TXA in each side through a drainage tube after joint capsule repair (group T), and 57 patients (group A) who underwent the procedure without TXA between October 2007 and August 2010 were tested. No significant difference in age and sex was observed between the two groups (p=0.572, 0.474). TXA was injected in patients with contraindications of intravenous administrations. Patients who underwent SBTKA with inflammatory arthritis were excluded from this study. The average amount of drainage, blood loss, transfusion rate, volume and daily average transfusion rate, and hemoglobin (Hb) change by the postoperative day were compared. Complications, such as deep vein thrombosis, pulmonary thromboembolism, myocardial infarction, cerebral infarction, and infection, were investigated. Results: The average total blood losses in groups A and T were 2195.32±1175.63 ml and 1145.09±382.95 ml, respectively, and the average total drain volume was 1,178.30±48.59 ml and 774.19±310.06 ml, respectively; both were significantly lower in group T (p=0.002, <0.001). The transfusion rates were 77.2% (44/57) and 0.7% (1/139), which were significantly lower in group T (p<0.001). The total average transfusion volume in groups A and T were 735.44±550.83 ml and 4.60±54.28 ml, respectively, which were significantly lower in group T (p<0.001). Hb tended to increase for three or four days after surgery in group A and group T. Regarding complications, deep vein thrombosis was encountered in two cases (1.4%), and pulmonary thromboembolism was noted in three cases (2.2%) in group T, but there were no cases in group A. No infections, cerebral infarction, or myocardial infarction occurred. Conclusion: In SBTKA, IA injections of TXA reduced the average drain volume, blood loss, transfusion rate, and volume significantly and did not increase the incidence of complications, even in patients with contraindications of intravenous administration.

Application of ANFIS for Prediction of Daily Water Supply (상수도 1일 급수량 예측을 위한 ANFIS적용)

  • Rhee, Kyoung-Hoon;Kang, Il-Hwan;Moon, Byoung-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.3
    • /
    • pp.281-290
    • /
    • 2000
  • This study investigates the prediction of daily water supply, which is a necessary for the efficient management of water distribution system. ANFIS, namely artificial intelligence, is a neural network into which fuzzy information is inputted and then processed. In this study, daily water supply was predicted through an application of network-based fuzzy inference system(ANFIS) for daily water supply prediction. This study was investigated methods for predicting water supply based on data about the amount of water which supplied in Kwangju city. For variables choice, four analyses of input data were conducted: correlation analysis, autocorrelation analysis, partial autocorrelation analysis, and cross-correlation analysis. Input variables were (a) the amount of water supply, (b) the mean temperature, and (c) the population of the area supplied with water. Variables were combined in an integrated model. Data of the amount of daily water supply only was modelled and its validity was verified in the case that the meteorological office of weather forecast is not always reliable. Proposed models include accidental cases such as a suspension of water supply. The maximum error rate between the estimation of the model and the actual measurement was 18.46% and the average error was lower than 2.36%. The model is expected to be a real-time estimation of the operational control of water works and water/drain pipes.

  • PDF

Oxide Semiconductor TFTs for the Next Generation LCD-TV Applications

  • Lee, Je-Hun;Kim, Do-Hyun;Yang, Dong-Ju;Hong, Sun-Young;Yoon, Kap-Soo;Hong, Pil-Soon;Jeong, Chang-Oh;Lee, Woo-Geun;Song, Jin-Ho;Kim, Shi-Yul;Kim, Sang-Soo;Son, Kyoung-Seok;Kim, Tae-Sang;Kwon, Jang-Yeon;Lee, Sang-Yoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1203-1207
    • /
    • 2008
  • For a large sized, ultra definition (UD) and high refresh rate for motion blur free AMLCD TVs, amorphous IGZO thin film transistor (TFT) are applied and investigated in terms of threshold voltage ($V_{th}$) shift influenced by active layer thickness uniformity, source drain etching technology, heat treatment and passivation condition. Optimizing above parameters, we fabricated the world's largest 15 inch XGA AMLCD successfully.

  • PDF

Experimental Study on Synthetic Fiber Filled Channel for Treating Turbid Water at the Construction Sites and Protecting Drain System (합성섬유 충진 여과수로를 이용한 건설사업장의 흙탕물 처리 및 배수구 보호에 관한 실험적 연구)

  • Yuan, Qingke;Cheng, Jing;Park, Kisoo;Kim, Youngchul
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.537-545
    • /
    • 2016
  • In order to cope with the new and strict government regulations for turbid water discharge from construction sites, this study tested whether synthetic fiber filters can replace conventional best management practices. The filter efficiency was about 10 to 60% with a varying filter depth of 5 to 15cm, presuming extreme storm flow conditions to be in the range of 800 to 1500m/day of filtration rates. Fiber filter acts exactly like a granular filter, i.e. the separation efficiency is directly and inversely proportional to filter depth and rate, respectively. Based on the operational data, we suggested the Log-Log design relationship, which can be used to determine the filter depth and area. Compared to the widely used gravel filter which treats the turbid water at the construction site, about 20% higher efficiency was obtained under similar operating conditions. Cleaning the filter through a simple hand-washing method at the time of break-through, achieved about 90% soil recovery.

A Study on Stability Criterion for Cryocooler Operating HTS Coils (냉동기운전 고온초전도코일의 안전성평가기준에 관한 연구)

  • Ishiyama, Atsushi;Kim, Seok-Beom;Han, Kyung-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.7
    • /
    • pp.317-323
    • /
    • 2001
  • We investigated the stability of cryocooler-cooled high-temperature superconducting (HTS) coils by using a computer program based on FEM. In this study, the current at which "thermal runaway" occurs, which depends on the relationship between the cooling power of the cryocooler and the heat generation in HTS coils, was adopted as a stability criterion of cryocooler operating HTS coils. It was shown that cryocooler-cooled HTS coil was stable in operating current above the critical current from the numerical analysis results by HTS model coil. And also, if we efficiently remove the heat generation from HTS coils by potimizing heat drain, the ramp-rate limitation can be mitigated because the effect of AC loss by the current rise was too small. Furthermore, in the case of pulsed operation; the HTS model coil is ramped from zero to the peak value in one second and back to zero current in one second, such as the operation of SMES device, the peak value of poerating current is 1.5-2 times greater than that of the thermal runaway current.

  • PDF

Azisymmetric Nonlinear Consolidation Analysis for Drainage-Installed Compressible Deposits (배수재가 설치된 압축성 지반의 축대칭 비선형 압밀해석)

  • 김윤태;이승래
    • Geotechnical Engineering
    • /
    • v.12 no.1
    • /
    • pp.5-20
    • /
    • 1996
  • In order to accelerate the rate of consolidation settlement and to gain a required shear strength for a given soft clay deposit, the preloading technique combined with a vertical drainage system has been widely applied. In this'study, the theory of axisymmetric consolidation which considers the variation of compressibility and permeability during the conslidation process, has ben developed. A computer program named AXICON for the analysis of axisymmetric nonlinear consolidation is developed by adopting an explicit finite difference method. Smear and well resistance effects are also considered. The AXICON is capable of analyzing the consolidation behavior of multi -layered deposits and simulates time dependent loading sequence. The results of AXICON are validated with analytical solutions of Hansbo and Barron, and compared with insitu settlements and pore pressures measured in a soft clay deposit.

  • PDF

Electrical Characteristics of Pentacene Thin Film Transistors.

  • Kim, Dae-Yop;Lee, Jae-Hyuk;Kang, Dou-Youl;Choi, Jong-Sun;Kim, Young-Kwan;Shin, Dong-Myung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.69-70
    • /
    • 2000
  • There are currently considerable interest in the applications of conjugated polymers, oligomers, and small molecules for thin-film electronic devices. Organic materials have potential advantages to be utilized as semiconductors in field-effect transistors and light-emitting diodes. In this study, pentacene thin-film transistors (TFTs) were fabricated on glass substrate. Aluminums were used for gate electrodes. Silicon dioxide was deposited as a gate insulator by PECVD and patterned by reactive ion etching (R.I.E). Gold was used for the electrodes of source and drain. The active semiconductor pentacene layer was thermally evaporated in vacuum at a pressure of about $10^{-8}$ Torr and a deposition rate $0.3{\AA}/s$. The fabricated devices exhibited the field-effect mobility as large as 0.07 $cm^2/V.s$ and on/off current ratio as larger than $10^7$.

  • PDF

A STUDY ON THE ELECTRICAL CHARACTERISTICS OF ORGANIC THIN FILM TRANSISTORS WITH SURFACE-TREATED GATE DIELECTRIC LAYER (표면 처리한 $SiO_2$를 게이트 절연막으로 하는 박막 트랜지스터의 특성 연구)

  • Lee, Jae-Hyuk;Lee, Yong-Soo;Park, Jae-Hoon;Choi, Jong-Sun;Kim, Eu-Gene
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.455-457
    • /
    • 2000
  • In this work the electrical characteristics of organic TFTs with the semiconductor-insulator interfaces, where the gate dielectrics were treated by the two methods which are the deposition of Octadecyltrichlorosilane (OTS) on the insulator and rubbing the insulator surface. Pentacene is used as an active semiconducting layer. The semiconductor layer of pentacene was thermally evaporated in vacuum at a pressure of about $2{\times}10^{-7}$ Torr and at a deposition rate of $0.3{\AA}/sec$. Aluminum and gold were used for the gate and source/drain electrodes. OTS is used as a self-alignment layer between $SiO_2$ and pentacene. The gate dielectric surface was rubbed before pentacene is deposited on the insulator. In order to confirm the changes of the surface morphology the atomic force microscopy (AFM) was utilized. The characteristics of the fabricated TFTs are measured to clarify the effects of the surface treatment.

  • PDF

Performance Ratings According to Characteristics of Thermosyphon Solar Hot Water System (자연대류형 태양열온수기의 특성별 성능평가에 관한 연구)

  • Kang, Y.H.;Kwak, H.Y.;Yoo, C.G.;Yoon, H.G.;Kang, M.C.;Lee, D.G.
    • Solar Energy
    • /
    • v.20 no.2
    • /
    • pp.9-17
    • /
    • 2000
  • To obtain thermal performance data, an experiment was performed with the two selected thermosyphon systems. The system parameters obtained by experimental data were used to perform TRNSYS simulation and verified TRNSYS model of thermosyphon solar hot water system. The thermosyphon solar hot water system was TYPE 145 which is modified from non-linear model. This model can describe heat exchange type and non-linear efficiency equation. It is possible to analyze the annual energy rate with efficiency equation and system specification. In this paper, we could compare the annual performance of the coil heat exchanger with that of the tank-in-tank heat exchanger. Under the same efficiency and parameter, heat exchange, drain, initial tank temperature, ratio of tank volume over collector area(V/Ac), regional annual performance rating were performed.

  • PDF