• 제목/요약/키워드: Down-scaled model test

검색결과 47건 처리시간 0.029초

SENSITIVITY ANALYSIS ABOUT THE METHODS OF UTILIZING THE HIGH RESOLUTION CLIMATE MODEL SIMULATION FOR KOREAN WATER RESOURCES PLANNING (I) : THEORETICAL METHODS AND FORMULATIONS

  • Jeong, Chang-Sam;Lee, Sang-Jin;Ko, Ick-Hwan;Heo, Jun-Haeng;Bae, Deg-Hyo
    • Water Engineering Research
    • /
    • 제6권2호
    • /
    • pp.63-71
    • /
    • 2005
  • Nowadays Climate disasters are frequently happening due to occasional occurrences of EI Nino and La Nina events and among them, water shortage is one of the serious problems. To cope with this problem, climate model simulations can give very helpful information. To utilize the climate model for enhancing the water resources planning techniques, probabilistic measures of the effectiveness of global climate model (GCM) simulations of an indicator variable for discriminating high versus low regional observations of a target variable are proposed in this study. The objective of this study is to present the various analysis methods to find the suitable application methods of GCM information for Korean water resources planning. The basic formulation uses the significance probability of the Kolmogorov-Smirnov test for detecting differences between two variables. The various methods for adopting correct association, changing the window size, discrimination condition, and the use of temporally down scaled data were proposed to find out the suitable way for Korean water resources planning.

  • PDF

Non-linear dynamic assessment of low-rise RC building model under sequential ground motions

  • Haider, Syed Muhammad Bilal;Nizamani, Zafarullah;Yip, Chun Chieh
    • Structural Engineering and Mechanics
    • /
    • 제74권6호
    • /
    • pp.789-807
    • /
    • 2020
  • Multiple earthquakes that occur during short seismic intervals affect the inelastic behavior of the structures. Sequential ground motions against the single earthquake event cause the building structure to face loss in stiffness and its strength. Although, numerous research studies had been conducted in this research area but still significant limitations exist such as: 1) use of traditional design procedure which usually considers single seismic excitation; 2) selecting a seismic excitation data based on earthquake events occurred at another place and time. Therefore, it is important to study the effects of successive ground motions on the framed structures. The objective of this study is to overcome the aforementioned limitations through testing a two storey RC building structural model scaled down to 1/10 ratio through a similitude relation. The scaled model is examined using a shaking table. Thereafter, the experimental model results are validated with simulated results using ETABS software. The test framed specimen is subjected to sequential five artificial and four real-time earthquake motions. Dynamic response history analysis has been conducted to investigate the i) observed response and crack pattern; ii) maximum displacement; iii) residual displacement; iv) Interstorey drift ratio and damage limitation. The results of the study conclude that the low-rise building model has ability to resist successive artificial ground motion from its strength. Sequential artificial ground motions cause the framed structure to displace each storey twice in correlation with vary first artificial seismic vibration. The displacement parameters showed that real-time successive ground motions have a limited impact on the low-rise reinforced concrete model. The finding shows that traditional seismic design EC8 requires to reconsider the traditional design procedure.

Separate and integral effect tests of aerosol retention in steam generator during tube rupture accident

  • Lee, Byeonghee;Kim, Sung-Il;Ha, Kwang Soon
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2702-2713
    • /
    • 2022
  • A steam generator tube rupture accompanying a core damage may cause the fission product to be released to environment bypassing the containment. In such an accident, the steam generator is the major path of the radioactive aerosol release. AEOLUS facility, the scaled-down model of Korean type steam generator, was built to examine the aerosol removal in the steam generator during the steam generator tube rupture accident. Integral and separate effect tests were performed with the facility for the dry and flooded conditions, and the decontamination factors were presented for different tube configurations and submergences. The dry test results were compared with the existing test results and with the analyses to investigate the aerosol retention physics by the tube bundle, with respect to the particle size and the bundle geometry. In the flooded tests, the effect of submergence were shown and the retention in the jet injection region were presented with respect to the Stokes number. The test results are planned to be used to constitute the aerosol retention model, specifically applicable for the analysis of the steam generator tube rupture accident in Korean nuclear power plants to evaluate realistic fission product behavior.

북방전복 Haliotis discus hannai (Ino, 1952) 의 폐사규명을 위한 모형 양식시설 주변의 조류 분포 분석 (Analysis of Current Distribution around a Scaled-down Abalone System to determine the cause of mass mortality of abalone, Haliotis discus hannai (Ino, 1952))

  • 차봉진;최양호;양용수;박민우;김병학;편용범
    • 한국패류학회지
    • /
    • 제30권1호
    • /
    • pp.9-15
    • /
    • 2014
  • 완도에서 주로 사용되는 4열 10행의 가두리 1조를 조합한 형태로 구성된 PE프레임의 내파성 전복가두리를 1/20로 축소하여 모형을 만들고 유체흐름 가시화 실험을 통해 전복가두리 주위의 해수의 흐름을 파악했다. 실험의 결과를 검증하기 위해 노화도 현장의 전복양식 가두리의 내부와 외부의 유속을 측정하였다. 연구의 결과는 아래와 같다. 1. 모형실험에서 전복가두리에 입사하는 해수는 대부분 첫 번째 단위 가두리 (칸) 를 통과하지 못하였다. 2. 모형 전복가두리 중앙 부위에서는 가두리에서 수조바닥으로 향하는 흐름을 관측하였다. 3. 모형 전복가두리의 외측 열을 빠져나가는 유체의 유속이 내측 열을 빠져나가는 유체의 유속보다 빨랐다. 4. 노화도의 현장 양식가두리의 2 m앞의 조류의 유속은 0.11 m/sec였지만 가두리 칸 내부의 유속은 0.0009 m/sec로 거의 움직임이 없었다. 5. 현재의 전복가두리 형태는 해수의 유통이 원활하지 않아 가두리 내부로 새로운 해수를 공급하기 어려울 것으로 판단된다.

Dynamic loading tests and analytical modeling for high-damping rubber bearings

  • Kyeonghoon Park;Taiji Mazda;Yukihide Kajita
    • Earthquakes and Structures
    • /
    • 제25권3호
    • /
    • pp.161-175
    • /
    • 2023
  • High-damping rubber bearings (HDRB) are commonly used as seismic isolation devices to protect civil engineering structures from earthquakes. However, the nonlinear hysteresis characteristics of the HDRB, such as their dependence on material properties and hardening phenomena, make predicting their behavior during earthquakes difficult. This study proposes a hysteretic model that can accurately predicts the behavior of shear deformation considering the nonlinearity when designing the seismic isolation structures using HDR bearings. To model the hysteretic characteristics of the HDR, dynamic loading tests were performed by applying sinusoidal and random waves on scaled-down specimens. The test results show that the nonlinear characteristics of the HDR strongly correlate with the shear strain experienced in the past. Furthermore, when shear deformation occurred above a certain level, the hardening phenomenon, wherein the stiffness increased rapidly, was confirmed. Based on the experimental results, the dynamic characteristics of the HDR, equivalent stiffness, equivalent damping ratio, and strain energy were quantitatively evaluated and analyzed. In this study, an improved bilinear HDR model that can reproduce the dependence on shear deformation and hardening phenomena was developed. Additionally, by proposing an objective parameter-setting procedure based on the experimental results, the model was devised such that similar parameters could be set by anyone. Further, an actual dynamic analysis could be performed by modeling with minimal parameters. The proposed model corresponded with the experimental results and successfully reproduced the mechanical characteristics evaluated from experimental results within an error margin of 10%.

축소모델을 통한 고속철도 차량의 진동특성 해석 및 검증 (Analysis of the Vibration Characteristics of a High-Speed Train using a Scale Model)

  • 한재현;김태민;김정태
    • 한국철도학회논문집
    • /
    • 제16권1호
    • /
    • pp.7-13
    • /
    • 2013
  • 철도차량의 실차 규모 동특성시험은 설비 구축, 대차의 제작 및 시험 조건의 설정등과 관련하여 비용, 시간 등의 증대로 많은 어려움이 따른다. 본 연구에서는 실험실 환경에서 차량 진동문제와 안전성을 평가하기 위한 목적으로 축소모델을 제작하고, 개발된 축소모델이 해당 철도차량의 동특성을 정밀하게 모사하는지를 검증하는 평가방법에 대한 연구를 수행하였다. 축소이론은 Jaschinski 상사기법의 이론을 적용하였으며, 1/10 축소모델을 구축하였다. 본 연구에서는 축소 대차의 상하 진동에 초점을 맞혀 시스템을 제작하였다. 시스템은 구동부, 보기, 대차 등 3개의 하부구조로 구성되었으며, 실제 차량으로 환산 시 400km/hr까지 실험가능 하도록 목표로 하였다. 축소 대차의 설계 및 제작과 함께, 동역학해석 프로그램인 ADAMS/View를 이용하여 고유치 해석을 수행하였다. 전산해석으로 도출된 고유진동수는 실험결과와 비교 분석되었다. 시스템이 가지고 있는 초기 5개의 자유도에 상응한 고유진동수를 비교한 결과, 개발된 상사 이론에 따른 축소모형은 충분한 신뢰성을 확보한 것으로 검증되었다. 본 연구에서 개발된 축소모델은 대학실험실에서 차량진동모드를 모사하는 용도로 기획되었으나, 추후 자유도의 추가보완을 통해 고속철도 차량의 대차와 보기구조 동특성 해석에 활용될 수 있을 것으로 판단된다.

각관 추진 굴착시 궤도노반의 침하경향 실험분석 (Test and analysis of settlement pattern of trackbed during pipe roof excavation)

  • 정관동;엄기영;최찬용;조수익;황인환
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.895-902
    • /
    • 2010
  • The method in a bid to make better use of limited urban space amidst increasingly expanding urban area have been attempted in various ways. Efficient using underground space is one of the examples. The pipe roof and excavation for underground crossing implemented in this study was the part of evaluation of such attempt. However, the pipe roof method for underground crossing may cause the ground surface to be uplifted or settled down, having effect on structure above the ground. Thus in this study, a laboratory model test designed to evaluate the effect on surface during implementing pipe roof and excavation was carried out. The ground displacement during pipe roof advancing and excavation is usually occurred in a radial shape but as the study focused on trackbed, the evaluation included ground settlement only. Thus, appropriately-scaled model was selected considering domestic geological characteristics and operation characteristics of traditional and high-speed rail trains and the qualitative evaluation of displacement was carried out with a certain ground loss depending on excavation after categorizing trackbed settlement pattern depending on depth of top soil.

  • PDF

IRWST 환형관 실험장치 내의 수소화염 가속현상에 대한 CFD 해석 연구 (CFD ANALYSIS FOR HYDROGEN FLAME ACCELERATION IN THE IRWST ANNULUS TEST FACILITY)

  • 강형석;하광순;김상백;홍성완
    • 한국전산유체공학회지
    • /
    • 제17권3호
    • /
    • pp.75-86
    • /
    • 2012
  • We developed a preliminary CFD analysis methodology to predict a pressure build up due to hydrogen flame acceleration in the APR1400 IRWST on the basis of CFD analysis results for test data of hydrogen flame acceleration in a scaled-down test facility performed by Korea Atomic Energy Research Institute. We found out that ANSYS CFX-13 with a combustion model of the so-called turbulent flame closure and a model constant of A = 5.0, a grid model with a hexahedral cell length of 5.0 mm, and a time step size of $1.0{\times}10^{-5}$ s can be a useful tool to predict the pressure build up due to the hydrogen flame acceleration in the test results. Through the comparison of the simulated results with the test results, we found out that the proposed CFD analysis methodology enables us to predict the peak pressure within an error range of about ${\pm}29%$ for the hydrogen concentration of 19.5%. However, the error ranges of the peak pressure for the hydrogen concentration of 15.4% and 18.6% were about 66% and 51%, respectively. To reduce the error ranges in case of the hydrogen concentration of 15.4% and 18.6%, some uncertainties of the test conditions should be clarified. In addition, an investigation for a possibility of flame extinction in the test results should be performed.

모형시험장치를 이용한 철도 선로변 방음벽에 미치는 공력 특성시험 (Aerodynamic Characteristics on Railway Acoustic Screen Using 1/61-scaled Mock-Up)

  • 장용준;김동현;박원희;박승일
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.430-437
    • /
    • 2007
  • The experiments for aerodynamic characteristics on railway acoustic screen are performed using 1/61 scale-down mock-up facility. The train model for the experiment is high speed train (KTX) and the tested speed is about 300km/h. The tested train length is about 61cm which is corresponding to two units of train. The strength of pressure wave is measured using piezo typed pressure sensor. The measured pressure is compared with field test data and UIC 779-1 values.

  • PDF

D-UPFC Application as the Series Power Device in the Massive Roof-top PVs and Domestic Loads

  • Lee, Kyungsoo
    • Current Photovoltaic Research
    • /
    • 제4권4호
    • /
    • pp.131-139
    • /
    • 2016
  • This paper shows the series power device in the massive roof-top PVs and domestic loads. D-UPFC as the series power device controls the distribution voltage during voltage rise (or fall) condition. D-UPFC consists of the bi-directional ac-ac converter and the transformer. In order to verify the D-UPFC voltage control, the distribution model is used in the case study. D-UPFC enables the voltage control in the distribution voltage range. Dynamic voltage control from voltage rise and voltage fall conditions is performed. Scaled-down experimental test of the D-UPFC is verified the voltage control and it is well performed without high voltage spikes in the inductive load.