• 제목/요약/키워드: Dowel connection system

검색결과 10건 처리시간 0.024초

Cyclic shear test on a dowel beam-to-column connection of precast buildings

  • Magliulo, Gennaro;Ercolino, Marianna;Cimmino, Maddalena;Capozzi, Vittorio;Manfredi, Gaetano
    • Earthquakes and Structures
    • /
    • 제9권3호
    • /
    • pp.541-562
    • /
    • 2015
  • This paper aims at developing the knowledge on the seismic behavior of dowel beam-to-column connections, typically employed in precast buildings in Europe. Despite the large diffusion of the industrial buildings, a high seismic vulnerability was exhibited by these structures, mostly due to the connection systems deficiencies, during some recent earthquakes (Emilia 2012, Turkey 2011). An experimental campaign was conducted on a typical dowel connection between an external column and a roof beam. In this paper, the performed cyclic shear test is described. According to the experimental results, the seismic response of the system is evaluated in terms of strength, stiffness and failure mechanism. Moreover, the complete damage pattern of the test is described by means of the instrumentations records. The connection failure occurred due to the concrete cover failure in the column (splitting failure). Such a mechanism corresponds to a negligible energy dissipation capacity of the connection, compared to the overall seismic response of the structure. The experimental results are also compared with the results of a similar monotonic shear test, as well as with some literature relationships for predicting the strength of dowel connections under horizontal (seismic) loads.

무량판 슬래브와 H형강 기둥 접합부 상세 개발 (Development for Connection Details between Flat Plate Slab and H-Steel Column)

  • 윤명호;이윤희
    • 복합신소재구조학회 논문집
    • /
    • 제5권1호
    • /
    • pp.22-27
    • /
    • 2014
  • The flat plate slab system have many good features, which are design flexibilities, saving of story-height and economy of construction etc. But the study of flat plate slab system for H-steel column have been rare both at home and abroad. Recently high-rise residential and commercial buildings have been constructed in urban areas in Korea. The suggested dowel connection system is more likely to adoptable because it remarkably contribute to save inter story height and also to have many advantages compared with conventional steel works such as H-Steel frame + Deck plate slab system. This study aims at developing design method and program for connection between H-Steel column and flat plate slab system, which contribute to save significantly inter-story height.

비내력벽의 손상제어를 위한 Steel Plate와 Dowel Bar 이격시스템에 대한 유한요소해석 (Finite Element Analytical Study of Steel Plate and Dowel Bar Systems Designed for Damage Reduction of Non-Bearing Walls)

  • 임창규;문교영;이홍석;김승직;김용남;이기학
    • 한국공간구조학회논문집
    • /
    • 제20권4호
    • /
    • pp.123-130
    • /
    • 2020
  • Generally the non-bearing walls in apartment buildings in Korea are not considered as a lateral force resisting members for the design consideration. This engineering practice caused large crack damages and brittle fractures of the non-bearing walls when subjected to Pohang earthquakes in 2017 since those have not been designed for seismic loading. In this study, finite element analysis was conducted for slot type non-bearing wall connection system to reduce damages and concentrate damages to the designated damping device through separation from the structural wall members. Steel plate and dowel bar systems designed for the dissipation of seismic energies were modeled and analyzed to investigate the damage reductions. Finally, the test result and the analysis result were compared and verified.

강재-콘크리트 하이브리드 보의 일축 전단 및 전단마찰 거동에서 장부철근의 영향평가 (Evaluation of Dowel Bar on the One-way Shear and Shear Friction Behaviors of Hybrid Beams Composed of Steel and Reinforced Concrete Elements)

  • 권혁진;양근혁;홍승현
    • 콘크리트학회논문집
    • /
    • 제29권1호
    • /
    • pp.93-100
    • /
    • 2017
  • 이 연구에서는 시공성이 단순한 연성형 절점을 갖는 HSRC 하이브리드 보 시스템의 콘크리트 보 영역에서의 일축 전단 및 연결절점 영역에서의 전단마찰 거동을 평가하였다. 일축 전단의 실험은 내민보 시스템으로써 파괴경간의 전단경간비는 1.6이다. 연결절점 영역에서의 전단마찰 거동을 평가하기 위한 실험은 상부 2점 집중하중으로써 순 전단경간비는 0.1이다. 실험 결과, 연결절점에서 배근된 장부철근이 HSRC 보의 균열 진전에 미치는 영향은 미미하였지만, 부재의 전단내력은 약 25% 향상시켰다. HSRC 보의 일축 전단 및 전단마찰 내력은 장부철근의 유무와 상관없이 ACI 318-14 및 EC2 설계식을 이용하여 안전 측에서 평가될 수 있었다.

강재 기둥과 하이브리드 강재 보-RC 보 접합부의 반복 휨 거동 평가 (Evaluation on Cyclic Flexural Behavior of HSRC (Hybrid H-steel-reinforced Concrete) Beams Connected with Steel Columns)

  • 권혁진;양근혁;홍승현
    • 콘크리트학회논문집
    • /
    • 제29권3호
    • /
    • pp.291-298
    • /
    • 2017
  • 이 연구에서는 강재 기둥과 접합된 하이브리드 H-보-철근 콘크리트 보(HSRC)의 반복 휨 거동을 평가하였다. 실험 변수는 HSRC 보의 연결절점에 배근되는 장부철근의 유무이다. HSRC 보의 소성힌지는 RC 보보다는 기둥 접합부 부근의 H-보에서 형성되도록 유도하였다. 모든 실험체는 하중의 급격한 감소 없이 연성적인 거동을 보였으며, 비록 예상치 못한 H-기둥과 H-보 용접 접합부의 파괴가 발생하였지만, 결과적으로 4.6 이상의 변위연성비를 나타내었다. HSRC 보 시스템에서 RC 보의 균열진전, 휨 강도 및 연성에 대한 장부철근의 영향은 매우 미미하였다. HSRC 보 시스템의 휨 강도는 단면의 완전소성으로 가정하여 산정한 H-보의 최대 휨 내력에 비해 안전 측에서 평가될 수 있었다.

플랫 플레이트 슬래브와 H형강 기둥 접합부의 구조 성능에 관한 실험적 연구 (An Experimental Study on Structural Performance of H-Steel or SRC Column and Flat Plate Slab Connection)

  • 윤명호;이윤희;유홍식;김진원
    • 복합신소재구조학회 논문집
    • /
    • 제5권2호
    • /
    • pp.9-14
    • /
    • 2014
  • Main topics in this study is a new structural detail for connection between H-Steel or SRC column and flat plate slab. We carried out to evaluate the punching shear performance of H-steel or SRC column + RC slab system for vertical load and lateral load. From the test results structural characteristics - yield moment, yield rotation, maximum moment, deformation capabilities ect. - are obtained and evaluated. In this paper as a shear reinforcement for supporting region of plate closed stirrup type and shear band are used, and their test results are compared.

철근콘크리트 공동주택의 평면확장을 위한 연결부의 전단성능 평가에 관한 연구 (A Study on Shear Connector Performance Estimation for Plan Extension of RC Apartment Structures)

  • 김동백
    • 한국안전학회지
    • /
    • 제30권2호
    • /
    • pp.27-34
    • /
    • 2015
  • Nowadays, remodeling cases for some apartment like Hyundai through the support of government are reported. Conventionally, balcony and aisle are extended for additional private area or balcony which is supported by new frame is extended. In extension work at site, dowel bar is conventionally inserted in old concrete slab for connection with old and new slab, however, an examination for structural safety is rarely performed prior to construction, if ever, vertical load is only considered for structural analysis. When conventionally connected structures are exposed to earthquake, the old and new structures have individual earthquake behavior with different mode, which may lead the elimination of resistance to earthquake in new structures. As of this reason, new detailing connection system which can have light weight and sufficient ductility performance is developed for application to domestic extension works. Additionally, user manual and specification are also developed for fertilization of application for the developed technology.

프리캐스트 콘크리트 더블월 시스템의 각형 강관 연결부 성능평가 (Evaluation of Steel Tube Connection in Precast Concrete Double Wall System)

  • 서유재;주현진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권2호
    • /
    • pp.25-32
    • /
    • 2023
  • 이 연구에서는 기존 프리캐스트 콘크리트 (Precast concrete, PC) 더블월 시스템의 복잡한 제작 공정을 간소화하면서 콘크리트 패널 형성 시 발생할 수 있는 레이턴스 등의 결함을 제거하고자 고안된 새로운 PC 더블월 공법을 소개하고 이때, PC 패널이 운반 또는 현장 콘크리트 타설 시 손상되지 않고 간격을 유지하는 역할을 하는 각형 강관에 대한 인장저항 성능을 규명하기 위한 실험적 연구를 수행하였다. 각형 강관의 단부 상세를 변수로 인장실험을 계획하였으며 개구부 형성에 따른 강판의 처리방법, 매립 콘크리트의 존치 유무, 추가적인 장부작용 확보를 위한 철근용접 등을 변수로 설정하여 효과적인 강관 단부 상세를 도출하고자 하였다. 결과적으로, 강관 단부의 측면을 절개한 강판을 강관 단부 방향 안쪽으로 절곡한 강관 실험체 (ST_CP)를 제외하고 기준실험체 (ST)에 비하여 20~30% 가량 증가한 최대 인장강도를 나타내었다. 기준실험체 내부에 콘크리트를 채운 실험체 (ST_CON)가 PC 더블월 제작 시 구성되는 각형 강관 연결부와 유사한 상세를 가지며 추가적인 시공과정과 비용이 요구되지 않으므로 가장 적합한 연결상세인 것으로 판단된다.

Steel-UHPC composite dowels' pull-out performance studies using machine learning algorithms

  • Zhihua Xiong;Zhuoxi Liang;Xuyao Liu;Markus Feldmann;Jiawen Li
    • Steel and Composite Structures
    • /
    • 제48권5호
    • /
    • pp.531-545
    • /
    • 2023
  • Composite dowels are implemented as a powerful alternative to headed studs for the efficient combination of Ultra High-Performance Concrete (UHPC) with high-strength steel in novel composite structures. They are required to provide sufficient shear resistance and ensure the transmission of tensile forces in the composite connection in order to prevent lifting of the concrete slab. In this paper, the load bearing capacity of puzzle-shaped and clothoidal-shaped dowels encased in UHPC specimen were investigated based on validated experimental test data. Considering the influence of the embedment depth and the spacing width of shear dowels, the characteristics of UHPC square plate on the load bearing capacity of composite structure, 240 numeric models have been constructed and analyzed. Three artificial intelligence approaches have been implemented to learn the discipline from collected experimental data and then make prediction, which includes Artificial Neural Network-Particle Swarm Optimization (ANN-PSO), Adaptive Neuro-Fuzzy Inference System (ANFIS) and an Extreme Learning Machine (ELM). Among the factors, the embedment depth of composite dowel is proved to be the most influential parameter on the load bearing capacity. Furthermore, the results of the prediction models reveal that ELM is capable to achieve more accurate prediction.

철근콘크리트 바닥판 평면확장 공법에 대한 연구 (Study on the Extension of Reinforced Concrete Slabs)

  • 김진평;김상식;최광호;전병갑;이정윤
    • 콘크리트학회논문집
    • /
    • 제18권3호
    • /
    • pp.321-330
    • /
    • 2006
  • 노후화된 철근콘크리트 공동주택을 리모델링할 경우에 거주성의 향상을 위하여 기존 바닥판에 새로운 바닥판을 신설하여 기존 건물의 평면을 확장시키는 경우가 많다. 새로운 바닥판이 기존 바닥판에 연결될 경우에 두 바닥판의 접합 방법에 따라서 힘의 흐름이 달라진다. 이 연구에서는 8개의 부분 실험체와 24개의 전체 실험체를 제작하여 3종류의 강절점으로 연결된 바닥판 접합부의 파괴모드와 내력을 실험적으로 평가하였다. 실험체의 주요변수는 강절점 접합방식, 철근의 묻힘 깊이(0, 50, 60, 100, 120mm), 묻힘 길이(100, 200, 300mm), 철근의 배근 간격(150, 200, 300, 450mm)이다. 실험에서 강절점으로 연결된 바닥판의 휨내력은 일체화된 바닥판의 철근항복시의 내력과 유사하였다.