Cyclic shear test on a dowel beam-to-column connection of precast buildings  

Magliulo, Gennaro (Department of Structures for Engineering and Architecture, University of Naples Federico II)
Ercolino, Marianna (Department of Structures for Engineering and Architecture, University of Naples Federico II)
Cimmino, Maddalena (Department of Structures for Engineering and Architecture, University of Naples Federico II)
Capozzi, Vittorio (Enel Green Power)
Manfredi, Gaetano (Department of Structures for Engineering and Architecture, University of Naples Federico II)
Publication Information
Earthquakes and Structures / v.9, no.3, 2015 , pp. 541-562 More about this Journal
Abstract
This paper aims at developing the knowledge on the seismic behavior of dowel beam-to-column connections, typically employed in precast buildings in Europe. Despite the large diffusion of the industrial buildings, a high seismic vulnerability was exhibited by these structures, mostly due to the connection systems deficiencies, during some recent earthquakes (Emilia 2012, Turkey 2011). An experimental campaign was conducted on a typical dowel connection between an external column and a roof beam. In this paper, the performed cyclic shear test is described. According to the experimental results, the seismic response of the system is evaluated in terms of strength, stiffness and failure mechanism. Moreover, the complete damage pattern of the test is described by means of the instrumentations records. The connection failure occurred due to the concrete cover failure in the column (splitting failure). Such a mechanism corresponds to a negligible energy dissipation capacity of the connection, compared to the overall seismic response of the structure. The experimental results are also compared with the results of a similar monotonic shear test, as well as with some literature relationships for predicting the strength of dowel connections under horizontal (seismic) loads.
Keywords
dowel connection; precast buildings; experimental test; cyclic behavior; seismic response;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Belletti, B., Damoni, C., Scolari, M. and Stocchi, A. (2013), "Studio delle rotture fragili di elementi di copertura prefabbricati collegati alle travi principali con inserti metallic", ANIDIS 2013, Padova (Italy).
2 CEN (2004), Eurocode 2: design of concrete structures - Part 1-1: General rules and rules for buildings, Brussels, Belgium.
3 CEN (2005), "Eurocode 8: design of structures for earthquake resistance - Part 1: general rules, seismic actions and rules for buildings. EN 1998-1", Brussels, Belgium.
4 CNR 10018 (1999), "Apparecchi di appoggio per le costruzioni (in Italian)", Bollettino Ufficiale del CNR, 21/12/1999 n. 190.
5 CNR 10025/98 (2000), "Istruzioni per il progetto, l'esecuzione ed il controllo delle strutture prefabbricate in calcestruzzo (in Italian)", Bollettino Ufficiale del CNR, 11/09/2000 n. 193.
6 D.M. 14/01/2008 (2008), "NormeTecniche per le Costruzioni (in Italian)", G.U. n. 29 4 febbraio 2008.
7 De Stefano, M., Tanganelli, M. and Viti, S. (2013), "On the variability of concrete strength as a source of irregularity in elevation for existing RC buildings: a case study", Bull. Earthq. Eng., 11(5), 1711-1726.   DOI
8 Eligehausen, R., Mallee, R. and Silva, J.F. (2006), Anchorage in Concrete Construction, Wiley, Berlin (Germany).
9 Fischinger, M., Ercolino, M., Kramar, M., Petrone, C. and Isakovic, T. (2011), "Inelastic seismic shear in multi-storey cantilever columns", 3rd ECCOMAS Thematic Conference on Computational Methods in Structural Dynamics and Earthquake Engineering, Corfu, Greece.
10 Kremmyda, G., Fahjan, Y. and Tsoukantas, S. (2014), "Nonlinear FE analysis of precast RC pinned beam-to-column connections under monotonic and cyclic shear loading", Bull. Earthq. Eng., 12(4), 1615-1638.   DOI
11 Magliulo, G., Capozzi, V., Fabbrocino, G. and Manfredi, G. (2011), "Neoprene-concrete friction relationships for seismic assessment of existing precast buildings", Eng. Struct., 33(2), 532-538.   DOI
12 Magliulo, G., Ercolino, M., Cimmino, M., Capozzi, V. and Manfredi, G. (2014a), "FEM analysis of the strength of RC beam-to-column dowel connections under monotonic actions", Constr. Build. Mater., doi: 10.1016/j.conbuildmat.2014.07.036.   DOI
13 Magliulo, G., Ercolino, M. and Manfredi, G. (2014b), "Influence of cladding panels on the first period of one-story precast buildings", Bull. Earthq. Eng., doi: 10.1007/s10518-014-9657-2.   DOI
14 Magliulo, G., Ercolino, M., Petrone, C., Coppola, O. and Manfredi, G. (2014c), "Emilia earthquake: the seismic performance of precast RC buildings", Earthq. Spectra, 30(2), 891-912.   DOI
15 Magliulo, G., Fabbrocino, G. and Manfredi, G. (2008), "Seismic assessment of existing precast industrial buildings using static and dynamic nonlinear analyses", Eng. Struct., 30(9), 2580-2588.   DOI
16 Negro, P. and Toniolo, G. (2012), Design guidelines for connections of precast structures under seismic actions, Luxembourg.
17 Toniolo, G. (2012), "SAFECAST project: European research on seismic behaviour of the connections of precast structures", 15th World conference on earthquake engineering (15WCEE), Lisbon, Portugal.
18 Psycharis, I.N. and Mouzakis, H.P. (2012a), "Assessment of the seismic design of precast frames with pinned connections from shaking table tests", Bull. Earthq. Eng., 10(6), 1795-1817.   DOI
19 Psycharis, I.N. and Mouzakis, H.P. (2012b), "Shear resistance of pinned connections of precast members to monotonic and cyclic loading", Eng. Struct., 41, 413-427.   DOI
20 Saatcioglu, M., Mitchell, D., Tinawi, R., Gardner, N.J., Gillies, A.G., Ghobarah, A., Anderson, D.L. and Lau, D. (2001), "The August 17, 1999, Kocaeli (Turkey) earthquake - damage to structures", Can. J. Civ. Eng., 28(4), 715-737.   DOI
21 Vintzeleou, E.N. and Tassios, T.P. (1986), "Mathematical-models for dowel action under monotonic and cyclic conditions", Mag. Concrete Res., 38(134), 13-22.   DOI
22 Vintzeleou, E.N. and Tassios, T.P. (1987), "Behavior of dowels under cyclic deformations", ACI Struct. J., 84(1), 18-30.
23 Zoubek, B., Isakovic, T., Fahjan, Y. and Fischinger, M. (2013), "Cyclic failure analysis of the beam-to-column dowel connections in precast industrial buildings", Eng. Struct., 52, 179-191.   DOI