• 제목/요약/키워드: Double-layer

검색결과 1,549건 처리시간 0.03초

An exact solution of dynamic response of DNS with a medium viscoelastic layer by moving load

  • S.A.H. Hosseini;O. Rahmani;H. Hayati;M. Keshtkar
    • Advances in materials Research
    • /
    • 제12권3호
    • /
    • pp.193-210
    • /
    • 2023
  • This paper aims to analyze the dynamic response of a double nanobeam system with a medium viscoelastic layer under a moving load. The governing equations are based on the Eringen nonlocal theory. A thin viscoelastic layer has coupled two nanobeams together. An exact solution is derived for each nanobeam, and the dynamic deflection is achieved. The effect of parameters such as nonlocal parameter, velocity of moving load, spring coefficient and the viscoelastic layer damping ratio was studied. The results showed that the effect of the nonlocal parameter is significantly important and the classical theories are not suitable for nano and microstructures.

탄화온도가 상이한 활성탄소 복합제 전극이 전기이중층 케페시터의 층방전 특성에 미치는 영향 (Effect of carbonization temperature of AC/C composite electrode on electro double layer capacitor)

  • 조영근;정두환;김창수;박소진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1821-1823
    • /
    • 1999
  • Carbon is an attractive material on electro double capacitor which depend on charge storage in the electrode/electrolyte interfacial double layer. Carbonaceous material for double layer capacitor can be obtained from carbon powder, fiber, film and porous carbon sheet. The capacitance of electrodes using an activated carbon was influenced by a filling density of the carbon, thickness and internal resistance of the electrode. In this study. to reduce internal resistance and increase electric conductivity of the electrode. activated carbon/carbon(AC/C) composite electrode was fabricated. The capacitors which have energy densities of 68F/g(at $30^{\circ}C$), 109F/g(at $60^{\circ}C$) and $68F/cm^3$(at $30^{\circ}C$), $111F/cm^3$(at $60^{\circ}C$) were fabricated by using AC/C composite electrodes.

  • PDF

전기이중층 캐패시터 전극용 meso-pore구조의 미소구형 활성탄소 제조 (Preparation of Micro-spherical Activated Carbon with Meso-porous Structure for the Electrode Materials of Electric Double Layer Capacitor)

  • 엄의흠;이철태
    • 공업화학
    • /
    • 제20권4호
    • /
    • pp.396-401
    • /
    • 2009
  • 전기이중층 캐패시터의 성능향상을 위한 전극물질로서 resorcinol-formaldehyde수지를 탄소원으로 사용하여 meso-pore 비율 52~64%의 기공특성을 지니며 직경 $2{\sim}10{\mu}m$의 미세구형 활성탄을 제조하였다. 이 활성탄을 전기이중층에 적용한 결과, meso-pore구조의 미세구형활성탄은 전하전달저항의 저감 및 충방전율 수용능력 향상에 효과적인 영향을 나타내어 전기이중층 캐패시터의 성능향상을 위한 효과적인 전극물질이 될 수 있음을 확인할 수 있었다.

Pillar Host Material로써 Layered(Mg/Al) Double Hydroxide의 물리화학적 특성화 (Physico-Chemical Characterization of the Layered Double Hydroxide as Pillar Host Material)

  • 형경우;이용석
    • 한국세라믹학회지
    • /
    • 제35권5호
    • /
    • pp.443-450
    • /
    • 1998
  • Layered double hydroxides(LDHs) [{{{{ {Mg }_{1-x } }}{{{{ {Al }_{x } }}({{{{ {OH}_{2 } }})]ζ+({{{{ {CO }`_{3 } ^{2- } ){ }_{x/2 } }}$.${{{{ { yH}_{2 }O }} wioth variation of layer charge densitywere synthesized by co-precipitation methdo since their charge densities have a very important role to be det-ermined the physicochemical properties of layered materials. The XRD IR and thermal studies of them were discussed and the kinetic study for the decarbonation reaction was also carried out. From the results of XRD analysis we found that the lattice parameter and the unit cell volume were linearly decreased with the amount of Al substituents(x) in the vicinity of x=2∼10${\times}$1/3${\times}$10-1 but they had nearly constant values when the x are far from these vicinit. The activation energies for the decarbonation reaction of x=6.8, 10${\times}$1/3${\times}${{{{ { 10}^{-1 } }} were estimated to be 47.0, 37.6, 39.3 kcal/mol The specific surface areas(90-120 m2/g) of stable hy-drotalcite-type LDHs were dractically decreased with increasing of layer charge density.

  • PDF

유럽 집합주택을 대상으로 한 환경친화적 외피의 특성 분석 - 외피의 구축적 특성에 따른 유형별 분석을 중심으로 - (A Study on the Characteristics of Environment-friendly Skins of European Housing - Focused on the Structural Characteristics of the skins -)

  • 원현성;김진우;오세규
    • KIEAE Journal
    • /
    • 제8권1호
    • /
    • pp.11-18
    • /
    • 2008
  • The purpose of this study is to analyze application methods and structural characteristics of each element of environment-friendly European housing through classification of skin types. The results of the study are following. 1) The skins are classified by three types; single skin with multi layers, double skin with single layer and double skin with multi layers. 2) Most single skins with multi-layer are composed with wooden louvers, sun blinds and insulating windows. There are introduction of atrium and balcony, and variation sectional space composition according to cases. 3) There are two types of double skins; to put cavity between inner skin and outer skin and more extensional spaces such as balconies, corridors and stair halls. Solar walls and mechanical ventilators are often introduced to double skins with multi-layer. 4) The functions of the latest environment-friendly skins are vary from controllers and buffers of indoor environmental elements such as temperature, light, air and sound to equipments to perform essential functions to efficiently operate HVAC systems.

Facilitation of the four-mask process by the double-layered Ti/Si barrier metal for oxide semiconductor TFTs

  • Hino, Aya;Maeda, Takeaki;Morita, Shinya;Kugimiya, Toshihiro
    • Journal of Information Display
    • /
    • 제13권2호
    • /
    • pp.61-66
    • /
    • 2012
  • The double-layered Ti/Si barrier metal is demonstrated for the source/drain Cu interconnections in oxide semiconductor thin-film transistors (TFTs). The transmission electromicroscopy and ion mass spectroscopy analyses revealed that the double-layered barrier structure suppresses the interfacial reaction and the interdiffusion at the interface after thermal annealing at $350^{\circ}C$. The underlying Si layer was found to be very useful for the etch stopper during wet etching for the Cu/Ti layers. The oxide TFTs with a double-layered Ti/Si barrier metal possess excellent TFT characteristics. It is concluded that the present barrier structure facilitates the back-channel-etch-type TFT process in the mass production line, where the four- or five-mask process is used.

초음속 이중 압축 램프의 앞전 곡률에 따른 천이 유동 해석 (TRANSITIONAL FLOW ANALYSIS OVER DOUBLE COMPRESSION RAMP WITH NOSE BLUNTNESS IN SUPERSONIC FLOW)

  • 신호철;사정환;박수형;변영환
    • 한국전산유체공학회지
    • /
    • 제20권4호
    • /
    • pp.36-43
    • /
    • 2015
  • Accurate prediction of supersonic transition is required for the heat transfer estimation over supersonic double compression ramp flows. Correlation-based transition models were assessed for a supersonic double ramp problem. Numerical results were compared with experimental data from RWTH Aachen University. A parametric study on the nose bluntness was performed using a selected transition model. As the nose bluntness increases, the boundary layer thickness is increased and the triple point of shock interactions moves downstream. The peak magnitude of the heat transfer is consequently decreased with the nose bluntness.

중공 이중판의 차음손실 예측에 있어서 경계손실이 미치는 영향 (Effects of Boundary Damping in the Prediction of Sound Insulation Performance of the Double Partition with Air-gap)

  • 이종화;이정권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.873-876
    • /
    • 2002
  • It has been reported that discrepancies exist in the case of double panels with an air layer when the measured sound transmission loss is compared with the calculated values. It has been known that the cause of this discrepancy is in major from the unavoidable dips associated with the double wall resonances. In this work, several correction methods to make up for such resonances are studied. In particular, the ‘boundary damping’concept is revisited and its effects are discussed by comparing with measured values. It is shown that the correction methods are necessary for the sound insulation analysis of double partitions with an air layer, in order to ascertain the quantitative correlation between measured and predicted values.

  • PDF

미니피그를 이용한 아세브로필린 이중정의 약동학적 평가 (아세브로필린 이중정 개발) (Pharmacokinetics of Acebrophylline Containing Double-layered Sustained Release Tablet in Mini Pigs)

  • 김강민;고찬영;강재선
    • 약학회지
    • /
    • 제57권6호
    • /
    • pp.442-447
    • /
    • 2013
  • The aim of the present study was to improve commercial twice-a-day Acebrophylline formulation to once-a-day new formulation to improve patient compliances. To develop the double-layered tablet, the sustained release layer was prepared using Eudragit$^{(R)}$ L100-55 and Carnauba wax. The sustained release layer has shown delayed release rates in pH 1.2 which comparable to that of performed in pH 6.8 buffer. In the comparative pharmacokinetic study with commercialized Surfolase$^{(R)}$, the present double-layered Acebrophylline tablet has shown similar pharmacokinetic parameters of AUC, $C_{max}$ and $T_{max}$ values.

플라스틱온실의 피복방식에 따른 보온 및 광투과 성능 평가 (Estimation of Heat Insulation and Light Transmission Performance According to Covering Methods of Plastic Greenhouses)

  • 이현우;김영식;심상연;이종원;소레이멘디옵
    • 생물환경조절학회지
    • /
    • 제22권3호
    • /
    • pp.270-278
    • /
    • 2013
  • 본 연구는 우리나라 상업용 온실의 보온성능 및 광투과 성능을 개선할 수 있는 피복방식을 결정하는데 필요한 자료를 제공하기 위하여 토마토 재배용 실험온실의 세 가지 피복방식에 대한 보온효과 및 광투과 특성을 평가하였으며 결과를 요약하면 다음과 같다. 공기주입 이중피복온실과 관행 이중피복온실의 관류열손실량이 거의 비슷한 것으로 나타났으나 외부기온이 비슷할 때 피복재와 보온커튼 사이의 온도가 공기주입 이중피복온실이 더 낮게 나타난 것은 공기주입 이중피복온실의 경우 나비식 천창의 틈새로 인한 환기전열손실이 크기 때문인 것으로 판단된다. 따라서 공기주입 이중피복온실에서 나비식 천창을 사용할 경우 틈새 환기전열손실을 줄일 수 있는 대책이 수립되어야 할 것으로 판단된다. 일중피복 온실과 관행이중피복온실의 관류열전달계수에 대한 온실 실험결과와 모형실험결과를 비교한 결과 모두 비슷한 값을 나타내었다. 이러한 결과는 측정된 관류열전달계수가 타당성 있는 값임을 보여주는 것이며 향후 온실의 난방설계시 직접 활용할 수 있을 것으로 기대된다. 공기주입 이중피복온실이 비록 일중피복온실보다는 광투과율이 낮으나 동일한 이중피복온실인 관행이중피복온실보다 광투과율이 높기 때문에 보온을 위해서 이중피복을 설치할 경우에 광투과율을 확보하기 위해서는 공기주입 이중피복방식을 채택하는 것이 바람직할 것으로 판단된다. 공기주입 이중피복온실에 비해 일중피복온실의 피복재 내부표면에서 발생하는 결로량이 큰 이유는 일중피복온실의 피복재 내부표면온도가 훨씬 낮기 때문에 피복재에서의 포화습도가 작아져 내부공기의 절대습도와의 차이가 증가하기 때문인 것으로 판단된다.