• Title/Summary/Keyword: Double tube heat exchanger

Search Result 65, Processing Time 0.029 seconds

An experimental study on heat transfer augmentation in fluidized bed heat exchanger (유동층형(流動層形) 열교환기(熱交換器)에서 전열증진(傳熱增進)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Yoo, Ji-Oh;Seo, Jeong-Yun
    • Solar Energy
    • /
    • v.13 no.2_3
    • /
    • pp.91-106
    • /
    • 1993
  • The purpose of this study was to investigate the enhancement of heat transfer coefficient in double pipe fluidized bed heat exchangers. The inner tube used a smooth tube and a finned tube equipped with longitudinal fins. The heat transfer coefficients between the heated tube and fluidized bed of alumina beads were calculated as a function of fluidized velocity in various particle sizes($d_p$=0.41, 0.54, 0.65, 0.77mm) and static bed heights($H_o$=50, 100, 150, 200, 250mm). The coefficient for finned tube is higher than for smooth tube. And the maximum increasing rate is 7.8 times in smooth tube and 12.9 times in finned tube.

  • PDF

Heat transfer characteristics of R - 407C condensing inside smooth horizontal tubes (냉매 R-407c의 수평평골 응축관내 열전달특성에 관한 연구)

  • 오후규;문정욱;노건상
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.2
    • /
    • pp.144-156
    • /
    • 1997
  • Experimental results for forced convection heat transfer of pure refrigerant and nonrefrigerant mixtures during condensing inside horizontal smooth tubes, double pipe heat exchanger of 7.5 mm ID and 4 000 mm long inside tube, are presented. Pure refrigerant R - 22 and R - 407 c, the mixture of R - 32 + R - 125 + R - 134a (23/25/52, wt %) are used as the test fluids. The ranges of parameters are $114.3{\sim}267.1 kg/(m^2 {\cdot} s)$ of mass velocity, <0$\sim$1.0 of quality. The vapor pressure, vapor temperature and tube wall temperature were measured. Using these data, the local and average heat transfer coefficients for the condensation are obtained. At the same given experimental conditions, the condensation heat transfer coefficients for NARMs R - 407c were lower than those for the pure refrigerant of R - 22. Local heat transfer characteristics for R - 407c were different from pure refrigerant R - 22. The condensaheat transfer coefficients for R - 407c and R - 22 increased with mass velocity. Based on the data a prediction method was presented for the calculation of dimensionless average heat transfer coefficient.

  • PDF

The Improvement of the Heat Exchanger Performance by Shape Modifieation(II) (형상변화 에 의한 열교환기 의 열전달 성능 향상 (II))

  • 노승탁;이택식;강신형;이은현;송명호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.2
    • /
    • pp.202-212
    • /
    • 1985
  • Numerical and experimental studies are presented for turbulent flows and heat transfer in annular channel with circumferential fins on the inner tube in a double pipe heat exchanger. Flow and heat transfer characteristics are periodically fully developed, and complex flow patterns are shown. Numerical calculations are executed by using modified TEACH-2E computer program based on the standard k-.epsilon. turbulence model. Mean velocity, turbulent kinetic energy, and Reynolds stress distributions are measured with the hot wire anemometer. Static pressures on the outer wall of the pipe are measured for three pitch-height ratios and several Reynolds numbers. Numerical predictions generally show reasonable results in comparison with experimental results. When the pitch-height ratio is about 5.0 and other geometric parameters are fixed in this paper, maximum heat transfer is achieved. Reattaching flow patterns appeared in this region. As the pitch between fins is increased beyond 5.0, mean Nusselt numbers are decreased and the pressure drop through one pitch almost remains.

Study on Condensing Pressure Drop of Hydrocarbon Refrigerants (탄화수소계 냉매의 응축 압력강하에 관한 연구)

  • Kim, Jae-Dol;Choi, Jun-Hyuk;Jeong, Seok-Kwon;Yoon, Jung-In;Lee, Ho-Saeng
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.218-224
    • /
    • 2006
  • Experimental results for pressure gradient of HCs refrigerants R-290. R-600a. R-1270 and HCFC refrigerant R-22 during condensing inside horizontal double pipe heat exchangers are presented. The test sections which have the tube inner diameter of 10.98mm. and the tube inner diameter of 8mm are used for this investigation. Hydrocarbon refrigerants have higher pressure drop than R-22 in both test sections with the diameters of 12.70mm and 9.52mm. Pressure drop increased with the increase of the mass flux. These results form the investigation can be used in the design of heat transfer exchanger using hydrocarbons as the refrigerant for the air-conditioning systems

Experimental Study on Compact type CO2 Gas Cooler(1) - Heat Flowrate and Pressure Drop in a Multi-Tube-In-Tube Helical Coil Type Gas Cooler - (CO2 가스쿨러용 콤팩트열교환기 개발에 관한 연구(1) -다중관식 헬리컬 코일형 가스냉각기내 CO2의 열유량과 압력강하-)

  • Oh, Hoo-Kyu;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.1
    • /
    • pp.30-36
    • /
    • 2010
  • The heat flowrate and pressure drop of $CO_2$ in a multi-tube-in-tube helical coil type gas cooler were investigated experimentally. The mass flowrate of $CO_2$ and coolant were varied from 0.06 to 0.075 [kg/s], respectively and the cooling pressure of gas cooler were from 8 to 10 [MPa]. The heat flowrate of $CO_2$ in the test section is increased with the increase in mass flowrate of coolant, the cooling pressure and mass flowrate of $CO_2$. The pressure drop of $CO_2$ is decreased with the decrease in mass flowrate of coolant and $CO_2$, but decreased with increase in cooling pressure of $CO_2$. The heat flowrate of $CO_2$ in the multi-tube-in-tube helical coil type gas cooler is greatly higher than that of $CO_2$ in the double pipe type gas cooler, while the pressure drop of $CO_2$ in the multi-tube-in-tube helical coil type gas cooler is greatly lower than that of $CO_2$ in the double pipe type gas cooler. Therefore, in case of the application of $CO_2$ at the multi-tube-in-tube helical coil type gas cooler, it is expected to carry out the high-efficiency, high-performance and compactness of gas cooler.

The Performance Investigation of Double-speaker-1/2 Wavelength Thermoacoustic Refrigerator (Double speaker 1/2파장 열음향 냉동기의 성능 평가)

  • Song Kyu Joe;Park Jong Ho;Lee Sung Ro
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.647-650
    • /
    • 2002
  • A thermoacoustic refrigerator, using a resonant standing acoustic wave, has been built. It employs a loudspeaker to sustain a standing wave in a resonance tube. The stack of plates is 0.075mm-thick plastic sheet(Mylar), spirally wound to make a 40mm-diameter assembly 80mm long. and two heat exchanger are installed. The refrigerant is Helium gas. The description of thermoacoustic refrigerator are presented. The directly measured performance of the resonator. Tc/Th ( temperature ratio ) and $COP/COP_{c}$, (normalized by carnot's COP ) are plotted versus the thermal load Q applied to the cold end, for various speaker power.

  • PDF

Development of Formation and Transportation Techniques for CO2-Hydrate Slurry (이산화탄소 하이드레이트 슬러리의 생성 및 수송기술개발)

  • Prah, Benedict;Yun, Rin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.7
    • /
    • pp.341-349
    • /
    • 2017
  • Formation and transportation of $CO_2$-hydrate slurry was conducted by circulating saturated water with $CO_2$ through a double-tube type heat exchanger which was cooled down by brine. The inner diameter and circulation length of the heat exchanger were 1 inch and 20 m, respectively. Water in tank was supersaturated by injected $CO_2$ and the operation pressure was maintained at 3,000 to 4,000 kPa with fluid-temperature of less than $9^{\circ}C$. $CO_2$ hydrate mass fraction was calculated based on density of $CO_2$-hydrate slurry mixture. Results showed that the $CO_2$-hydrate slurry could be circulated without blockage for 1 hr. Circulation status of the $CO_2$-hydrate slurry was also visualized.

A Study on Dynamic Simulation of a Hybrid Parallel Absorption Chiller (병렬식 하이브리드 흡수식 냉온수기 동특성 시뮬레이션 연구)

  • Shin, Young-Gy;Seo, Jung-A;Woo, Sung-Min;Kim, Hyo-Sang
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.630-635
    • /
    • 2008
  • A dynamic model has been developed to investigate the operability of a single and double-effect solar energy assisted parallel type absorption chiller. In the study, main components and fluid transport mechanism have been modeled. Flow discharge coefficients of the valves and the pumps were optimized for the double-effect mode with solar-heated water circulated. The model was run for the single mode with solar energy supply only and the solar/gas driving double effect mode. And the cases of the double mode with and without the solar energy were compared. From the simulation results, it was found that the present configuration of the chiller is not capable of regulating solution flow rates according to variable solar energy input. And the single mode utilizing the solar energy only is not practical. It is suggested to operate the system in the double mode and the flow rate control system adaptive to variable solar energy input has to be developed.

  • PDF

Experimental study for the pressure drop of R-22 and R-4O7C during the condensation in the micro-fin tubes (마이크로핀관내에서 R-22와 R-4O7C의 응축압력강하 특성에 관한 실험적 연구)

  • Roh, Geon-Sang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.715-722
    • /
    • 2007
  • Experiments were conducted for the investigation of pressure drop inside horizontal micro-fin tubes during the condensation of R-22 and ternary refrigerant. R-407C(HFC-32/125/134a 23/25/62 wt%) as a substitute of R-22. The condenser is a double-tube and counterflow type heat exchanger which is consisted with micro-fin tubes having 60 fins with a length of 4000mm, outer diameter of 9.53mm and fin height of 0.2mm. The mass velocity varied from 102.1 to $301.0kg/(m^2{\cdot}s)$ and inlet quality was fixed as 1.0. From the experimental results. the pressure drop for R-407C was considerably higher than that for R-22. The value of PF(penalty factor) for both of refrigerants was not bigger than the ratio of micro-fin tube area to smooth tube area. Based on the experimental data. correlation was Proposed for the prediction of frictional pressure drop during the condensation of R-22 and R-407C inside horizontal micro-fin tubes.

A Numerical Study on Operating Characteristics of a Miniature Joule-Thomson Refrigerator

  • Hong, Yong-Ju;Park, Seong-Je;Choi, Young-Don
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.4
    • /
    • pp.41-45
    • /
    • 2010
  • Miniature Joule-Thomson refrigerators have been widely used for rapid cooling of infrared detectors, optoelectronic device, and integrated circuits of micro electronics. The typical J-T refrigerator consists of the recuperative heat exchanger with the double helical tube and fin configuration, J-T nozzle, a mandrel, Dewar and a compressed gas storage bottle. In this study, to predict the thermodynamic behaviors of the refrigerator with a compressed gas storage bottle during the cool-down time, numerical study of transient characteristics for a J-T refrigerator was developed. A simplified transient one.dimensional model of the momentum and energy equations was simultaneously solved to consider the thermal interactions of the each component of the refrigerator. To account for effects of the thermal mass of the solid, the heat capacities of the tube, fins, mandrel and Dewar are considered. The results show the charged gas pressure of the gas storage bottle has significant effects on the performance of the J-T refrigerator. At the elevated gas pressure of the gas storage bottle, the large capacity of the compressed gas storage does not need to get the fast cool-down performance of the J-T refrigerator in the cool-down stage.