• Title/Summary/Keyword: Double scan

Search Result 104, Processing Time 0.029 seconds

Ureterosciatic hernia causing obstructive uropathy successfully managed with minimally invasive procedures

  • Kim, Yeong Uk;Cho, Jae Ho;Song, Phil Hyun
    • Journal of Yeungnam Medical Science
    • /
    • v.37 no.4
    • /
    • pp.337-340
    • /
    • 2020
  • Ureterosciatic hernia is extremely rare. In ureteral herniation, ureter prolapses occur through either the greater or lesser sciatic foramen. Atrophy of the piriformis muscle, hip joint diseases, and defects in the parietal pelvic fascia are predisposing factors for the development of ureterosciatic hernia. Most symptomatic patients have been treated surgically, with conservative treatment reserved only for asymptomatic patients. To the best of our knowledge, long-term follow-up outcomes after ureterosciatic hernia management are sparse. In this paper, we report the case of a 68-year-old woman who presented with colicky left abdominal pain. After computed tomography (CT) scan and anterograde pyelography, she was diagnosed ureterosciatic hernia with obstructive uropathy. We performed ureteral balloon dilatation and double-J ureteral stent placement. After this minimally invasive procedure, CT scan demonstrated that the left ureter had returned to its normal anatomical position without looping into the sciatic foramen. The patient remained asymptomatic with no adverse events 7 years after the minimally invasive procedures. This brief report describes ureterosciatic hernia successfully managed with minimally invasive procedures with long-term follow-up outcomes.

A New SOI LDMOSFET Structure with a Trench in the Drift Region for a PDP Scan Driver IC

  • Son, Won-So;Kim, Sang-Gi;Sohn, Young-Ho;Choi, Sie-Young
    • ETRI Journal
    • /
    • v.26 no.1
    • /
    • pp.7-13
    • /
    • 2004
  • To improve the characteristics of breakdown voltage and specific on-resistance, we propose a new structure for a LDMOSFET for a PDP scan driver IC based on silicon-on-insulator with a trench under the gate in the drift region. The trench reduces the electric field at the silicon surface under the gate edge in the drift region when the concentration of the drift region is high, and thereby increases the breakdown voltage and reduces the specific on-resistance. The breakdown voltage and the specific on-resistance of the fabricated device is 352 V and $18.8 m{\Omega}{\cdot}cm^2$ with a threshold voltage of 1.0 V. The breakdown voltage of the device in the on-state is over 200 V and the saturation current at $V_{gs}=5V$ and $V_{ds}$=20V is 16 mA with a gate width of $150{\mu}m$.

  • PDF

Surface Inspection Algorighm using Oriented Bounding Box (회전 윤곽 상자를 이용한 표면 검사 알고리즘)

  • Hwang, Myun Joong;Chung, Seong Youb
    • Journal of Institute of Convergence Technology
    • /
    • v.6 no.1
    • /
    • pp.23-26
    • /
    • 2016
  • DC motor shafts have several defects such as double cut, deep scratch on surface, and defects in diameter and length. The deep scratches are due to collision among the other shafts. So the scratches are long and thin but their orientations are random. If the smallest enclosing box, i.e. oriented bounding box for a detective point group is found, then the size of the corresponding defect can be modeled as its diagonal length. This paper proposes an suface inspection algorithm for the DC motor shaft using the oriented bounding box. To evaluate the proposed algorithm, a test bed is made with a line scan CCD camera (4096 pixels/line) and two rollers mechanism to rotate the shaft. The experimental result on a pre-processed image with contrast streching algorithm, shows that the proposed algorithm sucessfully finds 150 surface defects and its computation time (0.291 msec) is enough fast for the requirement (4 seconds).

Visualization of Structural Shape Information based on Octree using Terrestrial Laser Scanning (3D레이저스캐닝을 이용한 옥트리기반 구조물 형상정보 가시화)

  • Cha, Gichun;Lee, Donghwan;Park, Seunghee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.8-16
    • /
    • 2016
  • This study presents the visualization of shape information based on Octree using 3D laser scanning. The process of visualization was established to construct the Octree structure from the 3D scan data. The scan data was converted to a 2D surface through the mesh technique and the surface was then converted to a 3D object through the Raster/Vector transformation. The 3D object was transmitted to the Octree Root Node and The shape information was constructed by the recursive partitioning of the Octree Root Node. The test-bed was selected as the steel bridge structure in Sungkyunkwan University. The shape information based on Octree was condensed into 89.3%. In addition, the Octree compressibility was confirmed to compare the shape information of the office building, a computer science campus in Germany and a New College in USA. The basis is created by the visualization of shape information for double-deck tunnel and it will be expected to improve the efficiency of structural health monitoring and maintenance.

Ultrasonographic and radiographic study on experimental cystitis in rabbit (실험적 방광염 유발 토끼에서의 초음파 및 방사선학적 연구)

  • Sung, Jai-ki;Chang, Dong-woo;Yoon, Jung-hee
    • Korean Journal of Veterinary Research
    • /
    • v.36 no.4
    • /
    • pp.973-990
    • /
    • 1996
  • To investigate diagnostic imaging of cystitis and to apply it to the small animal practice, ultrasonogram of urinary bladder with moderate distension(4ml/kg) and with complete distension(9ml/kg) to evaluate the irregularity and thickness of bladder, radiography and histopathological examination were performed after experimental cystitis induction. On double contrast cystography, mucosal membrane of the urinary bladder was smooth and thickening urinary bladder wall was not found before cystitis induction. At 3rd day post induction(PI), mucosal irregularity was noted at the cranioventral region of the urinary bladder. Thickening of the urinary bladder wall and filling defect was observed as well. Cystographic findings of 7, 10, 15, 21 day PI were similar to that of 3rd day PI. On ultrasonographic findings of the mural thickness in induction group, it was ascertain that the mural thickness with moderate distention was more thickened than with complete distention at transverse scan. Ultrasonographic findings at longitudinal scan were similar to those of transverse scan. On ultrasonographic findings of mucosal irregularity in induction group, from PI to 7 day PI, mucosal irregularity with moderate distention was more irregular than mucosal irregularity with complete distention. At 10 day PI, there was similarity between moderate distention and complete distention. On histopathologic examination of a section of urinary bladder taken 3 day PI, the mucosal and submucosa were infiltrated by a mixture of thick inflammatory exudate which was composed of neutrophil, plasma protein, bacterial colony and necrotic cells. Congestion, hemorrhage and edema were also observed in the submucosa. At 7th day PI, the mucosal change was similar to that of 3rd day PI, but neovascularization and fibroplasia were observed in the submucosa. At 15th and 21th day PI, mild hyperplasia of mucosal epithelium was observed in the mucosa. Deposition of collagen, neovascularization and severe diffuse infiltration of lymphocyte were observed. These results suggest that ultrasonographic examination with moderate distention is considered to be a more simple, rapid, noninvasive, sensitive and useful diagnostic method than other diagnostic methods for the diagnosis of the cystitis and the differential diagnosis of urinary tract infection.

  • PDF

Enhancement of Image Contrast in Linacgram through Image Processing (전산처리를 통한 Linacgram의 화질개선)

  • Suh, Hyun-Suk;Shin, Hyun-Kyo;Lee, Re-Na
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.345-354
    • /
    • 2000
  • Purpose : Conventional radiation therapy Portal images gives low contrast images. The purpose of this study was to enhance image contrast of a linacgram by developing a low-cost image processing method. Materials and Methods : Chest linacgram was obtained by irradiating humanoid Phantom and scanned using Diagnostic-Pro scanner for image processing. Several types of scan method were used in scanning. These include optical density scan, histogram equalized scan, linear histogram based scan, linear histogram independent scan, linear optical density scan, logarithmic scan, and power square root scan. The histogram distribution of the scanned images were plotted and the ranges of the gray scale were compared among various scan types. The scanned images were then transformed to the gray window by pallette fitting method and the contrast of the reprocessed portal images were evaluated for image improvement. Portal images of patients were also taken at various anatomic sites and the images were processed by Gray Scale Expansion (GSE) method. The patient images were analyzed to examine the feasibility of using the GSE technique in clinic. Results :The histogram distribution showed that minimum and maximum gray scale ranges of 3192 and 21940 were obtained when the image was scanned using logarithmic method and square root method, respectively. Out of 256 gray scale, only 7 to 30$\%$ of the steps were used. After expanding the gray scale to full range, contrast of the portal images were improved. Experiment peformed with patient image showed that improved identification of organs were achieved by GSE in portal images of knee joint, head and neck, lung, and pelvis. Conclusion :Phantom study demonstrated that the GSE technique improved image contrast of a linacgram. This indicates that the decrease in image quality resulting from the dual exposure, could be improved by expanding the gray scale. As a result, the improved technique will make it possible to compare the digitally reconstructed radiographs (DRR) and simulation image for evaluating the patient positioning error.

  • PDF

Efficient Image Data Processing using a Real Time Concurrent Single Memory Input/Output Access (실시간 단일 메모리 동시 입출력을 이용한 효율적인 영상 데이터 처리)

  • Lee, Gunjoong;Han, Geumhee;Ryoo, Kwangki
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.103-106
    • /
    • 2012
  • A memory access method that data are read with different sequences with writing order is a simple but important procedure in many image compression standards, such as JPEG, MPEG1/2/4, H.264, and HEVC. For real time processing, double buffering is widely used using two block sized buffers, that accesses buffers concurrently with alternative way to read and write. In some cases like a transpose memory in 2D DCT with a simple and regular access order, a single buffering which requires only single block sized buffer can be used. This paper shows that even in complex access orders there is a regularity among updating orders within a finite turns, and suggested an effective implementation method using a single block sized buffer to process concurrent read/write operation with different access orders.

  • PDF

A Design of Efficient Scan Converter for Image Compression CODEC (영상압축코덱을 위한 효율적인 스캔변환기 설계)

  • Lee, Gunjoong;Ryoo, Kwangki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.2
    • /
    • pp.386-392
    • /
    • 2015
  • Data in a image compression codec are processed with a specific regular block size. The processing order of block sized data is changed in specific function blocks and the data is packed in memory and read by a new sequence. To maintain a regular throughput rate, double buffering is normally used that interleaving two block sized memory to do concurrent read and write operations. Single buffering using only one block sized memory can be adopted to the simple data reordering, but when a complicate reordering occurs, irregular address changes prohibit from implementing adequate address generating for single buffering. This paper shows that there is a predictable and recurring regularity of changing address access orders within a finite updating counts and suggests an effective method to implement. The data reordering function using suggested idea is designed with HDL and implemented with TSMC 0.18 CMOS process library. In various scan blocks, it shows more than 40% size reduction compared with a conventional method.

Evaluation of Imaging Studies in Male Infants less than 3 Months after First Urinary Tract Infection (3개월 이하의 남아에서 첫 요로 감염 후 방사선학적 검사의 평가)

  • Jung Jong Su;Kwon Kyung Ho;Kim Jong Sik;Lee Young Ah;Kim Hyun Jung;Lee Gyun Woo
    • Childhood Kidney Diseases
    • /
    • v.5 no.1
    • /
    • pp.30-35
    • /
    • 2001
  • Purpose : To evaluate tile frequency of urinary tract anomalies in male neonates less than 3 months old who presented with urinary tract infection(UTI) and to evaluate a appropriate imaging approach after first UTI. Materials and methods : During a period of 5 years from March 1994 to February 1999, 65 male infants less than 3months old(range: 4-92 days, mean: 43 days) with UTI were evaluated. Ultrasound(US) and Voiding cystourethrogram(VCUG) were done in 60 patients. Due to refusal and technological problem, 5 patients were missed. 99mTc-dimercaptosuccinic acid renal scan (99mTc-DMSA renal scan) was recommended to most patients but performed in 40 patients. Renal scan was performed at least 3 months later after urinary tract infection. Results : Urinary tract anomalies were found in 26 of 65 infants. Twenty-six had vesicoureteral reflux(VUR), two had both VUR and double ureter, two had both U and posterior urethral valve. In patients with VUR, eight had renal scar or renal atrophies. In case of renal scar or atrophy, grades of VUR were III or above. Conclusion : We suggest that US and VCUG should be routinely performed in infants(<3months)with first UTI. 99mTc-DMSA renal scan should be performed only when renal parenchymal damage was observed in US and VUR grade III or above in VCUG. (J. Korean Soc Pediatr Nephrol 5 : 30- 5, 2001)

  • PDF

Electrochemical Properties of EDLC Electrodes with Diverse Graphene Flake Sizes (그래핀 플레이크 크기에 따른 전기 이중층 커패시터용 전극의 전기화학적 특성)

  • Yu, Hye-Ryeon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.2
    • /
    • pp.112-116
    • /
    • 2018
  • Electric double layer capacitors (EDLCs) are promising candidates for energy storage devices in electronic applications. An EDLC yields high power density but has low specific capacitance. Carbon material is used in EDLCs owing to its large specific surface area, large pore volume, and good mechanical stability. Consequently, the use of carbon materials for EDLC electrodes has attracted considerable research interest. In this paper, in order to evaluate the electrochemical performance, graphene is used as an EDLC electrode with flake sizes of 3, 12, and 60 nm. The surface characteristic and electrochemical properties of graphene were investigated using SEM, BET, and cyclic voltammetry. The specific capacitance of the graphene based EDLC was measured in a 1 M $TEABF_4/ACN$ electrolyte at the scan rates of 2, 10, and 50 mV/s. The 3 nm graphene electrode had the highest specific capacitance (68.9 F/g) compared to other samples. This result was attributed to graphene's large surface area and meso-pore volume. Therefore, large surface area and meso-pore volume effectively enhances the specific capacitance of EDLCs.