• 제목/요약/키워드: Double insulation layers

검색결과 16건 처리시간 0.026초

토마토재배용 플라스틱온실의 이중피복방법에 따른 광합성유효광량자속 투과 및 열관류 특성 (Characteristics of PPF Transmittance and Heat Flow by Double Covering Methods of Plastic Film in Tomato Greenhouse)

  • 이현우;심상연;김영식
    • 한국농공학회논문집
    • /
    • 제52권5호
    • /
    • pp.11-18
    • /
    • 2010
  • This study was conducted to provide design data for deciding covering method in double layers greenhouse. The variation of photosynthetic photon flux (PPF) and heat flow in air inflated and conventional double layers greenhouse was analyzed. The PPF of air inflated double covering greenhouse was less than that of conventional greenhouse during summer season because the more PPF comes into conventional greenhouse through roof vent which was rolled up for ventilation. The air inflated double layers covering greenhouse was superior to conventional type in the aspect of controlling inside temperature down owing to lower irradiation. The PPF of air inflated greenhouse was greater than that of conventional greenhouse during winter season because the transmittance of conventional greenhouse decreased by dust collected on inside plastic film nearly closed for insulation. Considering the PPF not sufficient for tomato growing in winter, the air inflated double covering system with the greater transmittance was better than conventional covering system. When the inside air of air inflated greenhouse was injected into space between the double layers of covering, the PPF of air inflated greenhouse was much less than the conventional greenhouse because the transmittance of air inflated double covering decreased due to condensation of highly humidified inside air. It was concluded that the more dried outside air should be used for inflating double layers covering. The heat insulation performance of air inflated double covering system was superior to conventional double covering system when comparing the overall heat transfer coefficients for each covering method. However the differences among the overall heat transfer coefficients depending on difference between inside and outside temperatures of greenhouse were great, it is necessary to conduct additional experiment for investigating the overall heat transfer coefficient to design the double layers covering.

플라스틱온실의 피복방식에 따른 보온 및 광투과 성능 평가 (Estimation of Heat Insulation and Light Transmission Performance According to Covering Methods of Plastic Greenhouses)

  • 이현우;김영식;심상연;이종원;소레이멘디옵
    • 생물환경조절학회지
    • /
    • 제22권3호
    • /
    • pp.270-278
    • /
    • 2013
  • 본 연구는 우리나라 상업용 온실의 보온성능 및 광투과 성능을 개선할 수 있는 피복방식을 결정하는데 필요한 자료를 제공하기 위하여 토마토 재배용 실험온실의 세 가지 피복방식에 대한 보온효과 및 광투과 특성을 평가하였으며 결과를 요약하면 다음과 같다. 공기주입 이중피복온실과 관행 이중피복온실의 관류열손실량이 거의 비슷한 것으로 나타났으나 외부기온이 비슷할 때 피복재와 보온커튼 사이의 온도가 공기주입 이중피복온실이 더 낮게 나타난 것은 공기주입 이중피복온실의 경우 나비식 천창의 틈새로 인한 환기전열손실이 크기 때문인 것으로 판단된다. 따라서 공기주입 이중피복온실에서 나비식 천창을 사용할 경우 틈새 환기전열손실을 줄일 수 있는 대책이 수립되어야 할 것으로 판단된다. 일중피복 온실과 관행이중피복온실의 관류열전달계수에 대한 온실 실험결과와 모형실험결과를 비교한 결과 모두 비슷한 값을 나타내었다. 이러한 결과는 측정된 관류열전달계수가 타당성 있는 값임을 보여주는 것이며 향후 온실의 난방설계시 직접 활용할 수 있을 것으로 기대된다. 공기주입 이중피복온실이 비록 일중피복온실보다는 광투과율이 낮으나 동일한 이중피복온실인 관행이중피복온실보다 광투과율이 높기 때문에 보온을 위해서 이중피복을 설치할 경우에 광투과율을 확보하기 위해서는 공기주입 이중피복방식을 채택하는 것이 바람직할 것으로 판단된다. 공기주입 이중피복온실에 비해 일중피복온실의 피복재 내부표면에서 발생하는 결로량이 큰 이유는 일중피복온실의 피복재 내부표면온도가 훨씬 낮기 때문에 피복재에서의 포화습도가 작아져 내부공기의 절대습도와의 차이가 증가하기 때문인 것으로 판단된다.

고온초전도 전력케이블 저온용기의 최적단열설계에 관한 연구 (A Study of Optimum Insulation Conditions of a HTS Power Cable Cryostat)

  • 고득용;이관수
    • 설비공학논문집
    • /
    • 제19권4호
    • /
    • pp.333-338
    • /
    • 2007
  • The object of this study is to find the optimal insulation design conditions of a HTS power cable cryostat. The optimum condition of a cable cryostat is obtained by varying types of MLIs, cable core weights, spacer diameters, winding pitches and MLI layer numbers. As the weight of cable core is increased, conduction heat transfer from surroundings to cable cryostat is increased. But as the spacer pitch is increased from 120 mm to 200 mm, the heat leak of cable cryostat remains almost constant. The optimal number of MLI layers is suggested. Double ply MLI is more effective than triple ply MLI and the insulation effect is best when the number of MLI layers is 36.

인버터 서지와 온도스트레스 하에서 PAI/Nano Silica 에나멜와이어의 가속절연수명 평가 (Accelerated Insulation Life Estimation for PAI/Nano Silica Enamelled Wire under Inverter Surge and Temperature Stress)

  • 박재준
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1712-1720
    • /
    • 2016
  • AC and DC insulation breakdown voltage was studied for magnet wire coated with double layers of high flexural PAI layer and high anti-corona PAI/nanosilica (15 wt%) layer. The specimens were prepared at various drying temperatures (T/D): $22^{\circ}C$, $240^{\circ}C$, and $260^{\circ}C$, respectively. The increase effects of nanosilica on AC and DC insulation breakdown voltage were not so significant compared to that of magnet wire coil coated with original PAI. And the AC and DC insulation breakdown voltage was improved by decreasing diameter of winding coil. As T/D temperature increased, AC and DC insulation breakdown voltage decreased.

인버터 서지와 온도 스트레스 하에서 Magnet Wire 절연 수명평가 (Insulation Life Estimation for Magnet Wire Under Inverter Surge and Temperature Stress)

  • 박재준
    • 한국전기전자재료학회논문지
    • /
    • 제29권10호
    • /
    • pp.641-646
    • /
    • 2016
  • Coil specimen was prepared by coating a copper wire with two varnish thin layers: the first was polyamideimide (PAI)/nanosilica (5 wt%) varnish and the second was anti-corona PAI/nanosilica (15 wt%) varnish. Insulation breakdown voltage was investigated under inverter surge condition at $20^{\circ}C$, $70^{\circ}C$, $100^{\circ}C$, $150^{\circ}C$, $200^{\circ}C$, $250^{\circ}C$, respectively. The insulation lifetime of the two layered coil was tens of times longer than that of original PAI coil. And the insulation lifetime decreased with increasing ambient temperature because there was weak binding strength between copper and varnish layer.

고성능 MISFET형 수소센서의 제작과 특성 (Fabrication of MISFET type hydrogen sensor for high Performance)

  • 강기호;박근용;한상도;최시영
    • 한국수소및신에너지학회논문집
    • /
    • 제15권4호
    • /
    • pp.317-323
    • /
    • 2004
  • We fabricated a MISFET using Pd/NiCr gate for the detecting of hydrogen gas in the air and investigated its electrical characteristics. To improve stability and high concenntration sensitivity and remove the blister generated by the penetration of hydrogen atoms Pd/NiCr catalyst gate metal are used as dual gate. To reduce the gate drift voltage caused by the inflow of hydrogen, the gate insulators of sensing and reference FFET were constructed with double insulation layers of silicon dioxide and silicon nitride. The hydrogen response of MISFET were amplified with the difference of gate voltages of both MISFET. To minimize the drift and the noise, we used a OP177 operational amplifier. The sensitivity of the Pd/NiCr gate MISFET was lower than that of Pd/Pt gate MISFET, but it showed good stability and ability to detect high concentration hydrogen up to 1000ppm.

이중버블시트를 이용한 동상방지공법의 동절기 성토공사 Mock-up 실험 (Mock-Up Test On Anti-Freezing Method with Double bubble Sheets Subject to Cold weather Banking)

  • 홍석민;손호정;오치현;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.33-34
    • /
    • 2011
  • In this study, using the double bubble sheet to anti-freezing method in winter the soil embanking Mock up as a part of the development process was carried out. As results, two layers of the double bubble sheet effect 12.6℃~13.8℃ temperature difference of out door temperature that proved superior insulation and thermal performance of the double bubble sheet.

  • PDF

PAI 유/무기 하이브리드코일의 곡률변화에 따른 AC 및 DC 절연파괴 특성 (Insulation Breakdown Properties of AC and DC according to Curvature Variation of PAI Organic/Inorganic Hybrid Coils)

  • 박재준
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1721-1726
    • /
    • 2016
  • 4-types of coils were prepared by coating with polyamideimide (PAI) organic/inorganic hybrid. One type was made with original PAI vanish and the other 3-types were made of double layers, that was to say, high flexural PAI layer and high anti-corona PAI/nanosilica (15 wt%) layer. Drying temperature (T/D) were $220^{\circ}C$, $240^{\circ}C$, and $260^{\circ}C$, respectively and rectangular type coil for high-voltage rotating machine was used. DC and AC electrical breakdown tests were carried out in order to study the insulation properties according to T/D temperature and coil curvature (5, 15, and $25mm{\Phi}$). As the curvature increased, electrical breakdown voltage decreased and as T/D temperature decreased, electrical breakdown voltage increased.

단열시트(뽁뽁이)의 종류 및 부착위치에 따른 창호의 단열성능 평가 (Thermal Performance Evaluation of the Window Systems with Air-bubble Sheets)

  • 황제;정아희;전병헌;안영철
    • 설비공학논문집
    • /
    • 제27권9호
    • /
    • pp.463-467
    • /
    • 2015
  • The air-bubble sheet has been widely used to wrap fragile products for long-distance transportation. The further usage of the air-bubble sheet as a thermal-insulation material for the reduction of the thermal conductivities of window systems has occurred because of its low price, in addition to its thermal-conductivity properties. In this study, the thermal performances of a variety of commercial air-bubble sheets according to various applications were evaluated. The experiments were performed with single-glazed and double-glazed windows and three types of air-bubble sheets of different air volumes. U-values are used and were calculated for the determination of the thermal performances that are based on the KS F 2278. The maximum decrease of the U-value was measured as 1.092 when a sheet was attached onto the frame of single-glazed window. The square-like air-bubble sheet that contains the largest air volume shows the highest thermal-resistance value. Double layers of the air-bubble sheets show better performances than those of the single layers on both sides of the windows.

개량형 2중버블시트 양생막에 의한 온도이력 특성 (Temperature History of the Concrete Cured by the Curing Sheet made with Double Layered Bubble Sheet)

  • 김준호;손호정;손명식;경영혁;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.81-83
    • /
    • 2012
  • This paper is to compare the temperature history of the concrete using existing curing sheet and developed curing sheet made with double layered bubble sheet subjected to clod climate. Field application was conducted. According to results, application of developed curing sheet makes the temperature of curing house and concrete higher than existing curing sheet by about 3℃. This is due to the lower thermal conductivity of developed curing sheet.

  • PDF