Electromagnetic wave diffraction pattern by a circular cylindrical cavity in the denser medium (매질내의 원통형 공동에 의한 전자파 회절패턴)

  • 이택경;김세윤;라정웅
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.6
    • /
    • pp.10-18
    • /
    • 1995
  • Diffraction patterns of the electromagnetic field scattered by a circular cylindrical cavity embedded in a dielectric medium are analyzed. When the wavelength of the incident wave is comparable to the radius of the cavity, strong double dips occur at the locations corresponding to the top and the bottom of the cavity. Furthermore, the phase changes abruptly about the dip points. The changes of the amplitude and the phase patterns are observed as the measuring distance and the signal frequency varies. The effects of the change of the medium dielectric constant on the diffraction pattern is also presented.

  • PDF

A Fully Integrated Thin-Film Inductor and Its Application to a DC-DC Converter

  • Park, Il-Yong;Kim, Sang-Gi;Koo, Jin-Gun;Roh, Tae-Moon;Lee, Dae-Woo;Yang, Yil-Suk;Kim, Jung-Dae
    • ETRI Journal
    • /
    • v.25 no.4
    • /
    • pp.270-273
    • /
    • 2003
  • This paper presents a simple process to integrate thin-film inductors with a bottom NiFe magnetic core. NiFe thin films with a thickness of 2 to 3${\mu}m$ were deposited by sputtering. A polyimide buffer layer and shadow mask were used to relax the stress of the NiFe films. The fabricated double spiral thin-film inductor showed an inductance of 0.49${\mu}H$ and a Q factor of 4.8 at 8 MHz. The DC-DC converter with the monolithically integrated thin-film inductor showed comparable performances to those with sandwiched magnetic layers. We simplified the integration process by eliminating the planarization process for the top magnetic core. The efficiency of the DC-DC converter with the monolithic thin-film inductor was 72% when the input voltage and output voltage were 3.5 V and 6 V, respectively, at an operating frequency of 8 MHz.

  • PDF

On the Application af Robust Multivariable Controller to Distillation Column (증류탑 제어에 있어서 로바스트 다변수 제어 응용에 관한 연구)

  • 고재욱;이원규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.238-243
    • /
    • 1986
  • Distillation columns are widely used in almost every chemical plant. The use of multivariable control for such units is attractive because of the strong interactions exhibited between outputs and inputs and the desire to control simultaneously both top and bottom products. In this research design of a robust multivariable controller for distillation column was considered; output feedback controller with proportional and integral modes was designed using pole assignment. The transfer function matrix was obtained by fitting the step response realtions between single input double output pairs of variables. This matrix was then converted to linear time invariant state space model by multivariable realization technique. With the proposed multivariable proportional and integral controller applied to the process, the result of the digital computer simulation showed a good performance of asymtotic tracking. The limited experimental performance of this multivariable control was compared with the result from simulation. It was found that the proposed controller performed satisfactorily for the distillation column which separated binary mixture of methanol and water.

  • PDF

Deflection Analysis of Flexural Composite Members Considering Early-Age Concrete Properties (콘크리트의 초기재령특성을 고려한 합성형 휨 부재의 재령종속적 처짐해석)

  • 성원진;김정현;윤성욱;이용학
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.427-432
    • /
    • 2003
  • An analytical method to predict the flexural behavior of composite girder is presented in which the early-age properties of concrete are specified including maturing of elastic modulus, creep and shrinkage. The time dependent constitutive relation accounting for the early-age concrete properties is derived in an incremental format by expanding the total form of stress-strain relation by the first order Taylor series with respect to the reference time. The sectional analysis calculates the axial and curvature strains based on the force and moment equilibriums. The deflection curve of the box girder approximated by the quadratic polynomial function is calculated by applying to the proper boundary conditions in the consecutive segments. Numerical applications are made for the 3-span double composite steel box girders which is a composite bridge girder filled with concrete at the bottom of the steel box in the negative moment region. The one dimensional finite element analysis results are compared with those of the three dimensional finite element analysis and the analytical method based on the sectional analysis. Close agreement is observed among the three methods.

  • PDF

Finite Element Analysis of Flexural Composite Members Considering Early-Age Concrete Properties (콘크리트의 초기재령특성을 고려한 합성형 휨 부재의 유한요소 거동해석)

  • 강병수;주영태;신동훈;이용학
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.463-468
    • /
    • 2003
  • A finite element formulation to predict the flexural behavior of composite girder is presented in which the early-age properties of concrete are specified including maturing of elastic modulus, creep and shrinkage. The time dependent constitutive relation accounting for the early-age concrete properties is derived in an incremental format by expanding the total form of stress-strain relation by the first order Taylor series with respect to the reference time. The total potential energy of the flexural composite member is minimized to derive the time dependent finite element equilibrium equation. Numerical applications are made for the 3-span double composite steel box girders which is a composite bridge girder filled with concrete at the bottom of the steel box in the negative moment region. The numerical analysis with considering the variation of concrete elastic modulus are performed to investigate the effect of it on the early-age behavior of composite structures. The one dimensional finite element analysis results are compared with the analytical method based on the sectional analysis. Close agreement is observed among the two methods.

  • PDF

Nondestmctive Evaluation of Cracks in Metal Plates by using SQUID Gradiometer

  • 황윤석;김진태;이순걸;박용기
    • Progress in Superconductivity
    • /
    • v.3 no.2
    • /
    • pp.159-162
    • /
    • 2002
  • We have detected cracks inside multi-layer metal sheets with nondestructive evaluation system consisting of SQUID gradiometer. Double D-shape coil was carefully designed with computer simulation for spatial distribution of magnetic field. It was aligned and placed in between SQUID and metal sheets in order to reduce the field effect to SQUID and to maximize eddy current in the sheets. The metal plate in bottom of the metal stack contained artificial cracks which were scanned by an X-Y scanning system. The information of crack position and size could be estimated by analysis of SQUID signal. Details of the results will be discussed .

  • PDF

Case Study of Intermittent Engine Hesitation Fault Diagnosis By CKPS Fault (LPI차량에서 CKPS불량으로 주행 중 간헐적인 엔진부조 현상의 고장진단)

  • Kim, Sung Mo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.6
    • /
    • pp.624-629
    • /
    • 2014
  • The purpose of this study is to carry out the task of engine hesitation which occurred intermittently in driving due to the defective CKPS of LPI vehicles. As the result of the wrong data from the equipment of D-logger, the signal error of CKPS caused the engine hesitation. We performed a study in the followings to analyze and investigate the cause effectively. First, we have investigated the control wiring harness and connector pin contact defect inspection. Second, we have inspected the defection of CKPS separately. From this study, it was found that the engine hesitation were caused by the bad durability and we have showed how to diagnosis the fault of the engine hesitation intermittently while driving. Therefore, it is determined that we have to improve the durability of the CKPS through a strict quality control and to increase the reliability.

Evaluation of Mucous Membrane lrritation by Hydroxyapatite Sinter Produced from Tuna Bone in Syrian Hamsters (참치뼈로부터 Hydroxyapatite 소결체의 햄스터에 대한 구강점막자극시험)

  • 김세권;박표잠
    • Journal of Life Science
    • /
    • v.10 no.6
    • /
    • pp.605-609
    • /
    • 2000
  • In order to evaluate the safety of hydroxyapatite sinter produced from tuna bone in Syrian hamsters, oral mucous membrane irritation test was carried out. Oral mucous membrane irritation test was infected in Syrian hamsters as dose of 5 g/kg BW with hydroxyapatite sinder under pentobarbital sodium anesthesia. Each animal`s left cheek pouch was everted, and the samples were loosely placed at the bottom of the pouch with a double-suture technique for 14 days. Hamsters of control group were treated without inserting the hydroxylapatite sinter. Any abnormal clinical signs in both cheek pouches of control and treatment group were not observed for 14 days. There were no significant differences in body weight changes between hamsters of control and treatment group. Therefore, it suggest that hydroxyapatite sinter produced from tuna bone has no particular changes of oral mucous membrane irritation in Syrian hamsters.

  • PDF

Investigation of buckling behavior of functionally graded piezoelectric (FGP) rectangular plates under open and closed circuit conditions

  • Ghasemabadian, M.A.;Kadkhodayan, M.
    • Structural Engineering and Mechanics
    • /
    • v.60 no.2
    • /
    • pp.271-299
    • /
    • 2016
  • In this article, based on the higher-order shear deformation plate theory, buckling analysis of a rectangular plate made of functionally graded piezoelectric materials and its effective parameters are investigated. Assuming the transverse distribution of electric potential to be a combination of a parabolic and a linear function of thickness coordinate, the equilibrium equations for the buckling analysis of an FGP rectangular plate are established. In addition to the Maxwell equation, all boundary conditions including the conditions on the top and bottom surfaces of the plate for closed and open circuited are satisfied. Considering double sine solution (Navier solution) for displacement field and electric potential, an analytical solution is obtained for full simply supported boundary conditions. The accurate buckling load of FGP plate is presented for both open and closed circuit conditions. It is found that the critical buckling load for open circuit is more than that of closed circuit in all loading conditions. Furthermore, it is observed that the influence of dielectric constants on the critical buckling load is more than those of others.

Deviation of Subthreshold Swing for the Ratio of Top and Bottom Oxide Thickness of Asymmetric Double Gate MOSFET (비대칭 이중게이트 MOSFET의 상하단 산화막 두께비에 따른 문턱전압이하 스윙의 변화)

  • Jung, Hakkee;Jeong, Dongsoo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.849-851
    • /
    • 2015
  • 본 연구에서는 비대칭 이중게이트 MOSFET의 상하단 게이트 산화막 두께 비에 대한 문턱전압이하 스윙 및 전도중심의 변화에 대하여 분석하고자한다. 문턱전압이하 스윙은 전도중심에 따라 변화하며 전도중심은 상하단의 산화막 두께에 따라 변화한다. 비대칭 이중게이트 MOSFET는 상단과 하단의 게이트 산화막 두께를 다르게 제작할 수 있어 문턱전압이하 스윙의 저하 등 단채널효과를 감소시키기에 유용한 소자로 알려져 있다. 본 연구에서는 포아송방정식의 해석학적 해를 이용하여 문턱전압이하 스윙을 유도하였으며 상하단의 산화막두께 비가 전도중심 및 문턱전압이하 스윙에 미치는 영향을 분석하였다. 결과적으로 문턱전압이하 스윙 및 전도중심은 상하단 게이트 산화막 두께 비에 따라 큰 변화를 나타냈다. 또한 채널길이 및 채널두께, 상하단게이트 전압 그리고 도핑분포함수의 변화에 따라 문턱전압이하 스윙 및 전도중심은 상호 유기적으로 변화하고 있다는 것을 알 수 있었다.