• Title/Summary/Keyword: Double Rings

Search Result 74, Processing Time 0.032 seconds

Finite Element Analysis on the Sealing Contact Stress of a CNG Fueling Nipple for Vehicles (자동차용 CNG 충전니플의 밀봉접촉응력에 관한 유한요소해석)

  • Kim, Chung Kyun;Yoo, Jae Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.67-72
    • /
    • 2012
  • In this study, the leak-free performance and sealing endurance safety of CNG fueling nipple in which are related to the contact normal stress and equivalent true stress have been analyzed for CNG automobile using a finite element analysis. For the conventional circular o-rings and new double-lip o-rings with an initial compression rate of 15 percentages, the leak-free performance of double-lip o-rings with two contact sealing spots is 41% higher than that of the conventional circular o-rings with a contact sealing spot. The FEM computed results present that the leak-free endurance safety of double-lip o-rings with two contact sealing spots is 5% higher than that of the conventional circular o-rings for initial compression ratio of 15 percentages and a gas compression pressure of 8MPa. And, the maximum equivalent true stress of double-lip o-rings is 10.2% higher than that of the conventional circular o-rings for the leak-free endurance safety. This means that the double-lip o-ring may guarantee the extended sealing life compared to that of a conventional circular o-ring.

The Design of Balun-BPF with Double Ring-Resonators (두 개의 링-공진기로 구성된 Balun-BPF의 설계)

  • Kang, Seong-Jun;Hwang, Hee-Yong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.8
    • /
    • pp.878-883
    • /
    • 2008
  • In this paper, we propose a double rings structure to improve the balanced-port characteristics of Balun-Bandpass Filter(Balun-BPF). The conventional Balun-BPF has limitations on output symmetry and skirt steepness. We introduce a double rings structure and the suitable coupling point between the two ring resonators to solve these problems. The fabricated double rings Balun-BPF shows excellent characteristics as a Balun-BPF without the conventional limitations.

Uni-axial behaviour of normal-strength CFDST columns with external steel rings

  • Dong, C.X.;Ho, J.C.M.
    • Steel and Composite Structures
    • /
    • v.13 no.6
    • /
    • pp.587-606
    • /
    • 2012
  • Concrete-filled-steel-tubular (CFST) columns have been well proven to improve effectively the strength, stiffness and ductility of concrete members. However, the central part of concrete in CFST columns is not fully utilised under uni-axial compression, bending and torsion. It has small contribution to both flexural and torsion strength, while it can be replaced effectively by steel with smaller area to give similar load-carrying capacity. Also, the confining pressure in CFST columns builds up slowly because the initial elastic dilation of concrete is small before micro-crackings of concrete are developed. From these observations, it is convinced that the central concrete can be effectively replaced by another hollow steel tube with smaller area to form double-skinned concrete-filled-steel-tubular (CFDST) columns. In this study, a series of uni-axial compression tests were carried out on CFDST and CFST columns with and without external steel rings. From the test results, it was observed that on average that the stiffness and elastic strength of CFDST columns are about 25.8% and 33.4% respectively larger than CFST columns with similar equivalent area. The averaged axial load-carrying capacity of CFDST columns is 7.8% higher than CFST columns. Lastly, a theoretical model that takes into account the confining effects of steel tube and external rings for predicting the uni-axial load-carrying capacity of CFDST columns is developed.

A Numerical Study on the Contact Behavior Analysis of Double Layer O-rings (이중 O링의 접촉거동 해석에 관한 수치적 연구)

  • 김청균;조승현
    • Tribology and Lubricants
    • /
    • v.19 no.1
    • /
    • pp.9-14
    • /
    • 2003
  • The sealing performance of an elastomeric O-ring using the double layered material has been analyzed fer the contact stress behaviors that develop between the O-ring seal and the surfaces with which it comes into contact. The leakage of an O-ring will occur when the pressure differential across the seal Just exceeds the initial (or static) peak contact stress. The contact stress behaviors that develop in compressed O-rings, in common case of dovetail grooved geometry, are investigated using the finite element method. The FE analysis includes material hyperelasticity and axisymmetry. The computed FEM results show that the contact stress behaviors are related to the ratio of diameter between the inner ring and the outer ring, and the temperature of vacuum chamber.

NEW EXTREMAL BINARY SELF-DUAL CODES OF LENGTHS 66 AND 68 FROM CODES OVER Rk,m

  • Kaya, Abidin;Tufekci, Nesibe
    • Bulletin of the Korean Mathematical Society
    • /
    • v.54 no.1
    • /
    • pp.29-42
    • /
    • 2017
  • In this work, four circulant and quadratic double circulant (QDC) constructions are applied to the family of the rings $R_{k,m}$. Self-dual binary codes are obtained as the Gray images of self-dual QDC codes over $R_{k,m}$. Extremal binary self-dual codes of length 64 are obtained as Gray images of ${\lambda}-four$ circulant codes over $R_{2,1}$ and $R_{2,2}$. Extremal binary self-dual codes of lengths 66 and 68 are constructed by applying extension theorems to the ${\mathbb{F}}_2$ and $R_{2,1}$ images of these codes. More precisely, 10 new codes of length 66 and 39 new codes of length 68 are discovered. The codes with these weight enumerators are constructed for the first time in literature. The results are tabulated.

A Rare Case of Tracheomalacia Associated with Vascular Ring in an Infant

  • Han Seok Joo;Sung Tae Yon;Lee Kyo Jun;Choi Hong Sik;Shim Yon Hee;Nam Yong Taek
    • Korean Journal of Bronchoesophagology
    • /
    • v.10 no.2
    • /
    • pp.63-67
    • /
    • 2004
  • Tracheomalacia can be a life threatening upper air way obstructive disease in an infant and vascular rings can be also a major rare cause of tracheoesophageal obstruction. These two rare entities can be combined in one patient because the vascular ring can cause secondary tracheomalacia during development of fetus. The diagnosis of this combination and adequate surgical correction is occasionally difficult. This is a report of an infant who had not diagnosed tracheomalacia associated with vascular ring until 5 months of age because of the prolonged tracheal intubation. The rigid bronchoscopic examination performed under impression of tracheomalacia revealed a concentric tracheal collapse, an unusual bronchoscopic findings of tracheomalacia, which raised a suspicion of the tracheal compression by vascular rings. The 3-D reconstructive DT aortography clearly demonstrated the double aortic arch. The patient was treated surgically by simple division of the left aortic arch and aortopexy with good result. The vascular ring such as double aortic arch should be considered during the diagnosis of tracheomalacia in infants. If the tracheomalacia is associated with vascular ring, simultaneous surgical correction should be performed.

  • PDF

Computer Simulation of Double Osteotomy in Tibia Using Double-Hexapod External Fixator (이중 헥사포드 외고정 기구를 이용한 선천성 왜소증 환자의 경골 교정 시뮬레이션)

  • 주상민;김윤혁
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.916-919
    • /
    • 2004
  • In this paper, we proposed a new method of pre-operative planning for tibial deformity correction using double hexapod external fixator in pseudoacondroplasia. The 3-D computer graphic model of deformed tibia was reconstructed from 3 mm sliced CT data, and CAD model of double hexapod external fixator was developed. The fixator was composed of 170 mm diameter of three rings and 90 mm of twelve struts. The bone deformities and the osteotomy lines for double osteotomy were measured using X-rays, and the necessary joint values to correct the given deformities were obtained by inverse kinematics analysis. The computer graphic simulation was performed to visualize the deformity correction process and evaluate the analysis result. By examining the pre-op and post-op X-rays, the simulation result was in good agreement with the clinical outcomes.

  • PDF

Double Aortic Arch with Right Sided Descending Aorta - Report of 1 case - (우측 하행 대동맥을 동반한 중복 대동맥궁 - 1례 수술 치험 -)

  • 조경수
    • Journal of Chest Surgery
    • /
    • v.23 no.1
    • /
    • pp.201-204
    • /
    • 1990
  • The double aortic arch is the commonest anomaly among the vascular rings are relatively rare congenital vascular anomalies. This anomaly is malformation of the aortic arch system may, by compression of the trachea and esophagus, cause respiratory distress and dysphagia. We experienced one case of double aortic arch with right sided descending aorta with predominant right anterior arch treated surgically at Kyung Hee University Medical Center. 1-year-old male patient with acute airway obstruction due to combination of double aortic arch and right descending aorta. The diagnosis was made by simple X-ray & confirmed by barium esophagogram & aortogram. The operative approach was through left thoracotomy & underwent division of the left aortic arch & division of ligamentum arteriosum & suspension of divided proximal end of anterior arch to anterior thoracic wall. The postoperative courses was uneventful and doing well on the 3 years.

  • PDF

The Crystal Structure of Fully Dehydrated Fully $Ba^{2+}$-Exchanged Zeolite X

  • 장세복;김양
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.3
    • /
    • pp.248-251
    • /
    • 1995
  • The crystal structure of Ba46-X, Ba46Al92Si100O384 [a= 25.297(1) Å], has been determined by single-crystal X-ray diffraction techniques in the cubic space group Fd&bar{3}at 21(1) ℃. The crystal was prepared by ion exchange in flowing stream of 0.05 M Ba(OH)2 aqueous solution for 5 days. The crystal was then dehydrated at 380 ℃ and 2 × 10-6 Torr for 2 days. The structure was refined to the final error indices R1= 0.051 and Rw= 0.054 with 369 reflections for which I > 3σ(I). In this structure, all Ba2+ ions are located at the three different crystallographic sites: fourteen Ba2+ ions are located at site Ⅰ, the centers of the double six rings, two Ba2+ ions lie at site Ⅰ', in the sodalite cavity opposite double six rings(D6R's) and another thirty Ba2+ ions are located at site Ⅱ in the supercage. Two Ba2+ ions are recessed ca. 0.27 Å into the sodalite cavity from their three O(3) oxygen plane and thirty Ba2+ ions are recessed ca. 1.11 Å into the supercage from their three O(2) oxygen planes, respectively (Ba(1)-O(3) = 2.76(1) Å, O(3)-Ba(1)-O(3) = 180(0)°, Ba(2)-O(3) = 2.45(1) Å, O(3)-Ba(2)-O(3) = 108(1)°, Ba(3)-O(2)=2.65(1) Å, and O(2)-Ba(3)-O(2)=103.9(4)°).

Crystal Structure of Fully Dehydrated Partially Cs+-Exchanged Zeolite X, Cs52Na40-X (The Highest Cs+-Exchanged Level Achieved by Conventional Method and Confirmation of Special Site Selectivity)

  • Bae, Myung-Nam
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.2
    • /
    • pp.251-256
    • /
    • 2007
  • The crystal structure of fully dehydrated partially Cs+-exchanged zeolite X, [Cs52Na40Si100Al92O384], a = 24.9765(10) A, has been determined by single-crystal X-ray diffraction techniques in the cubic space group Fd3 at 21 °C. The crystal was prepared by flow method for 5 days using exchange solution in which mole ratio of CsOH and CsNO3 was 1 : 1 with total concentration of 0.05 M. The crystal was then dehydrated at 400 °C and 2 × 10-6 Torr for 2 days. The structure was refined to the final error indices, R1 = 0.051 and wR2 (based on F2) = 0.094 with 247 reflections for which Fo > 4σ (Fo). In this structure, about fifty-two Cs+ ions per unit cell are located at six different crystallographic sites with special selectivity; about one Cs+ ion is located at site I, at the centers of double oxygen-rings (D6Rs), two Cs+ ions are located at site I', and six Cs+ ions are found at site II'. This is contrary to common view that Cs+ ions cannot pass sodalite cavities nor D6Rs because six-ring entrances are too small. Ring-opening by the formation of ?OH groups and ring-flexing make Cs+ ions at sites I, I', and II' enter six-oxygen rings. The defects of zeolite frameworks also give enough mobility to Cs+ ions to enter sodalite cavities and D6Rs. Another six Cs+ ions are found at site II, thirty-six are located at site III, and one is located at site III' in the supercage, respectively. Forty Na+ ions per unit cell are located at two different crystallographic sites; about fourteen are located at site I, the centers of D6Rs and twenty-six are also located at site II in the supercage. Cs+ ions and Na+ ions at site II are recessed ca. 0.34(1) A and 1.91(1) A into the supercage, respectively. In this work, the highest exchange level of Cs+ ions per unit cell was achieved in zeolite X by conventional aqueous solution methods and it was also shown that Cs+ ion could pass through the sixoxygen rings.