Analysis on the power generation efficiency by the direct sunlight (태양광 발전 시스템별 직사광선에 의한 발전효율 분석)

  • Lee, Jaydy;Rhee, Sang-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.89-91
    • /
    • 2008
  • The photovoltaic industry is growing at a tremendous speed. And it can be one of the key factors for success in the photovoltaic business to choose a suitable system, and setting it up right so as to get a maximum efficiency of the site. Therefore, it is regarded to be necessary to research the efficiency of systems to catch maximum photovoltaic energy. In this research, the expected power generation efficiencies are analysed, and compared with each other. This research considered the direct sunlight only, and the angle between the direction of solar panel and sunlight as factors to affect the power generation. Therefore, only rough analyses and estimations are found on 3 systems of fixed system, double-axes tracking system, and horizontal tracking system.

  • PDF

Shape Optimization of Micro-probes and Its Contact Forces (마이크로 탐침의 형상최적설계 및 접촉력 계산)

  • Jang, Dong-Sue;Kim, Cheol;Kim, Kwang-Joong
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.608-613
    • /
    • 2007
  • Fine pitch microprobe arrays are microneedle-like probes for inspecting the pixel of LCD panel. They are usually made of multilayers of metallic, nonmetallic, or combination of the two. In this study, the microprobe arrays were fabricated using the process applied for MEMS fabrication technology and they consist of BeCu, BeNi, or Si. Their contacting probing force and deflection were measured using the laser equipment. The design requirement are 5gf of a minimum contact force and $150{\mu}m$ of a maximum deflection. A lot of microprobe shape are possible satisfying the requirement. A double cantilever-type microprobe having needles on both ends were applied for this study. Several candidate were chosen using the topology and shape optimization technique subjected to the design requirements. Finite element results and experimental results were compared and both gave good correlation.

  • PDF

An Experimental Study on Reinforced Effect Using Double Adhensive Panels in Bridge Deck Slabs (프리케스트판을 이용한 교량상판 단면증설 보강공법에 관한 실험적 연구)

  • 박정기;하경민;지한상;김은겸
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.791-796
    • /
    • 2000
  • Purpose of this study is to analyze the characteristics and reinforcement effects of restored the RC bridge deck with small precast panel through static load tests and to provide the basic information for the damaged slab decks. In the tests for realizing movement of general RC bridge slabs, 6 samples are prepared and tested. All reinforced samples are restored with 1 or 2-layers precast panels by epoxy mortar. The movement of restored slabs is analyzed and compared with the behavior of non-restored slabs. In result of these tests, tension cracks due to bending moment are show, and after static load test there happens finally a punching shear failure, which is the general type of RC bridge failure. The tests show that restoration of the RC slab results in increasing of loading capacity about 30~50% an restoring panels are stick to slab and moving with slab under loading test.

  • PDF

Noise Barrier Design for Increased Sound Absorption (흡음률 증가를 위한 방음벽 구조)

  • Kim Hyun-Sil;Kim Jae-Seung;Kang Hyun-Joo;Kim Bong-Ki;Kim Sang-Ryul
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.367-370
    • /
    • 2001
  • Various shapes of the noise barrier frame and construction of the sound absorbing panels are studied. It is found that insertion of the sound absorbing panel into barrier frame results in the decrease of the sound absorption coefficient, while the empty frame shows a peak around 250Hz. Using double sound absorbing panels with air gap can increase sound absorption coefficient up to NRC 0.85.

  • PDF

Mechanical behaviors of multi-layered foam core sandwich composite (다층 구조 폼 코아 샌드위치 복합재의 기계적 거동 연구)

  • Oh J.O.;Yoon S.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.381-382
    • /
    • 2006
  • The mechanical behaviors of multi-layered foam core sandwich composite were investigated through a 3-point bending test. The sandwich specimens were obtained from sandwich panel consisting of aluminum faces and urethane foam core. Three types of sandwich specimens such as a single structure, a double structure and a triple structure were considered. The span of sandwich specimens were varied from 170mm to 350mm. According to the results, the flexural and shear properties of multi-layered sandwich composite were found to be higher than those of single-layered sandwich composite.

  • PDF

Development of a Simplified Test Apparatus for Measuring Sound Transmission Loss (간이 차음시험장치 개발)

  • 이해성;전오성;강현주;김봉기
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.892-897
    • /
    • 2003
  • This study deals with the performance of a simplified test apparatus for measurement of sound insulation of panels. In order to investigate its performance, results from experiment and theory of the sound transmission loss for single and double panels are compared. Comparative results show that in evaluation of the sound insulation performance, the test apparatus has a cumbersome problem at the low frequency region, i.e. below 315 ㎐, presumably because of the poor diffuse sound field in the chambers. Meanwhile at the high frequency, it shows a considerable results comparable to the theoretical prediction. One of the objective of this study that compares measured results between a real reverberation chamber and a simplified test apparatus, by using a specimen of a sandwich panel. It shows qualitatively resonable agreement from which one can find a potential to provide a design tool.

  • PDF

A Stress Analysis of Double-deck Train with Composite Material (복합재료 2층 기차의 응력해석)

  • 이영신;김재훈;박병준;김기남;주정수
    • Proceedings of the KSR Conference
    • /
    • 1999.05a
    • /
    • pp.75-82
    • /
    • 1999
  • 본 연구의 목적은 구체 경량화의 일환으로써, 복합재료(3-X Board, Al extrusion panel, etc) 사용에 대한 가능성을 판단하기 위한 기초자료를 구축하는데 있다. 해석 대상은 2층 기차의 객차부분이고, 구체에 적용하는 복합재료는 3-X Board를 이용하였다. 구체의 구조 건전성을 평가하기 위해 상용 유한요소 프로그램을 이용하여 다양한 하중 하에서의 응력해석을 수행하였다. 구체에 사용되는 복합재료(3-X board)의 응력발생 경향을 파악하는 것이 목적이므로, 상세한 모델보다는 단순화한 모델을 이용하였다. 응력집중은 센터실(center sill), 1층 바닥과 측면과의 연결부, 그리고, 구체의 앞부분 창문 모서리에서 발생하였다. 압축 및 수직하중 하에서의 응력값들은 재료의 항복강도 내에 존재하였으나, 고유진동수는 제한 값보다 낮은 값을 갖았다. 현재 상세 모델에 대한 해석을 수행 중에 있다. 본 연구는 복합재료(3-X board)가 적용된 구체에 대한 초기 연구로써 만족할 만한 결과를 제시한다.

  • PDF

Double-stage Batch Fermentation of Beer Part II. Trials under Plant Fermention Conditions (이단회분식 맥주발효 제II보 공장발효조건하에서의 시양)

  • Pack, M.Y.
    • Microbiology and Biotechnology Letters
    • /
    • v.3 no.2
    • /
    • pp.89-93
    • /
    • 1975
  • In order to ferment beer more effectively under conditions similar to the conventional batch fermentation, a part of the wort which had been fermenting for three days was replaced with un-pitched fresh wort and completed the rest of the fermentation in four to six days. The taste test panel accepted the beers fermented for five days after diluting with one third or one half volume of freshl wort giving fermentation efficiency gains by 22% or 28% over the regular nine-day batch fermentation respectively.

  • PDF

Microplasma Current Switch for OLED applications

  • Cai, Jie-Yu;Kim, Myung-Min;Moon, Cheol-Hee;Lee, Sang-Youn;Yi, Seung-Jun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.854-857
    • /
    • 2009
  • The concept of a microplasma current switch for a device operated in a current mode like organic light-emitting diodes, which features matrix addressability and current switching, is presented as well as its architecture and operational principle. To verify the concept, we have fabricated a 100 mm ${\times}$ 100 mm microplasma current switch panel with a cell pitch of $1080{\mu}m{\times}1080{\mu}m$. Moreover, the current-voltage measurements of the unit cell are performed for three different driving voltage amplitudes. They show the characteristic of an asymmetric floating double probe diagnosing plasmas.