• 제목/요약/키워드: Double Effect

검색결과 2,762건 처리시간 0.031초

고려인삼의 비루스성 급성간염의 치료효과에 미치는 임상학적 연구(II) (Clinical Study on the efficacy of Panax Ginseng C. A. Meyer on Acute viral(B) Hepatitis- (II))

  • 구국회;주충노
    • Journal of Ginseng Research
    • /
    • 제7권2호
    • /
    • pp.125-132
    • /
    • 1983
  • It was attempted in the present study to determind the effect of Korean ginseng on acute viral(B type) hepatitis by double blind test clinically and the results were as follows. 1. The double blind test of 4 week period showed no statistical significance of the effect of ginseng on the disease. 2. The double blind test of 2 week period, however, showed a significant effect in such clinical symptoms as appetite, stomach ache, headache, chillness dizziness, nausea and vomitting, stool habit change and jaundice. Improvement of the blood serum level of transaminases, bilirubin. alkaline phosphatase and cholesterol Chillness feeding period was observed.

  • PDF

이중 효용과 일중 효용을 복합한 다단 재생 고효율 흡수식 냉동 사이클 개발 (Development of High Efficiency Cycle by Combining Double-Effect with Single-Effect Absorption Chiller Systems)

  • 윤상국
    • 설비공학논문집
    • /
    • 제29권7호
    • /
    • pp.360-365
    • /
    • 2017
  • Recently, development efforts of triple-effect absorption chiller have been increased in order to improve the efficiency of double-effect absorption chiller. However, triple-effect absorption chiller has some disadvantages, including high corrosion characteristic of LiBr solution at high temperature of $200^{\circ}C$. Moreover, it is necessary to develop new components for operation under high pressure of 2 bars even though COP is increased to 1.6 or 1.7. The objective of this study was to introduce a new system by combining double effect absorption chiller with single effect absorption chiller with multi-generators using bypass flow of LiBr dilute solution to $3^{rd}$ generator to overcome the disadvantages of triple-effect chiller and improve energy efficiency. Results indicate that the new absorption cycle had a much higher efficiency than double-effect chiller system, showing significant improvement when bypass solution flow rate of 25% was applied to the $3^{rd}$ generator using the main dilute solution of the absorber. The COP of the new chiller system was found to be 1.438, which was 21.7% higher than that (1.18) of the present double-effect system. The COP was decreased when solution by-pass rate to the $3^{rd}$ generator was increased. In addition, lower cooling water temperature caused higher COP. Therefore, the multi-generator system with by-pass solution might be an excellent chiller alternative to triple-effect absorption chiller with higher efficiency.

급속 삽입법에 의한 화염 내부 온도 분포 측정 (Temperature Measurement in Concentric Diffusion Flames by Rapid Insertion Technique)

  • 이교우;정영록;정종수
    • 한국연소학회지
    • /
    • 제4권2호
    • /
    • pp.75-83
    • /
    • 1999
  • The effect of temperature distributions on soot volume fraction in double-concentric diffusion flames have been investigated experimentally. Using fine thermocouple wires and a rapid insertion mechanism, we have measured temperature without the effect of soot particles attached to the thermocouple junction, which can lower the temperature signal about 100 K by increasing the heat loss from the junction by radiation. The temperature at the flame axis is higher in the double-concentric diffusion flames than in normal co-flow diffusion flames because of the inverse diffusion flame. However, it is almost the same as that at the periphery of normal flames, on which the inverse flame does not have an effect. Thus, the lower soot concentration found in the double-concentric diffusion flame can be explained by the effect of nitrogen diffusion from the central air jet.

  • PDF

이중확산 대류계에서의 부력효과에 관한 연구(II) - 이론적 연구 - (A Study on Buoyancy Effects in Double-Diffusive Convecting System(II) - Theoretical Study -)

  • 홍남호;김민찬;현명택
    • 한국해양공학회지
    • /
    • 제13권2호통권32호
    • /
    • pp.129-137
    • /
    • 1999
  • The time of the onset of double-diffusive convection in time-dependent, nonlinear concentration fields is investigated theoretically. The initially quiescent horizontal fluid layer with a uniform temperature gradient experiences a sudden concentration change from below, but its stable thermal stratification affects concentration effects in such way to invoke convective motion. The related stability analysis, including Soret effect, is conducted on the basis of the propagation theory. Under the linear stability theory the concentration penetration depth is used as a length scaling factor, and the similarity transform for the linearized perturbation equations. The newlly obtained stability equations are solved numerically. The resulting critical time to mark the onset of regular cells are obtained as a function of the thermal Rayleigh number, the solute Rayleigh number, and the Soret effect coefficient. For a certain value of the Soret effect coefficient, the stable thermal gradient promote double-diffusive convective motion.

  • PDF

동계 이중외피와 내부식재에 의한 실내 온도 특성에 관한 연구 (The Characteristics of the winter season window and indoor temperature due to the indoor plant)

  • 윤영일;조주영
    • KIEAE Journal
    • /
    • 제15권5호
    • /
    • pp.107-112
    • /
    • 2015
  • Purpose: This study desires to investigate an effect of indoor temperature, humidity, and illuminance targeting a planting system of double-skin facade and cavity space adjacent to the outside within a certain period of winter. Through this, the study suggests a basic material about an energy conservation effect of double window system using planting to reduce heating load of a building in winter, so desires to contribute to indoor thermal comfort effect and illuminance correction study of double window and indoor plant. Method: Considering effects such as day and night climatic elements and air conditions in winter, illuminance measurement was conducted through a double-skin facade of space, a subject of the measurement, on the basis of practical residence time of a resident, and this study analyzed characteristics of indoor illuminance about this. The study measured and compared a change of insolation, dry-bulb temperature, and relative humidity at each indoor-outdoor measuring point, so measured and compared characteristics of an indoor temperature effect by elements of double-skin facade and indoor plant. Result: Through this study, the researcher could determine that indoor plant within double window in winter not only blocks solar radiation but also photosynthesizes, so is somewhat disadvantageous to winter thermal comfort reducing heating load. In addition, solar radiation going through interior plays a role to bring down somewhat high humidity to about 50% of reasonable humidity, so plays a direct role of maintenance of comfortable indoor space. Although there are effects such as blocking of solar radiation and temperature reduction, this has a positive influence on humidity control and proper illuminance distribution. The researcher could determine that illuminance, temperature, and humidity by solar radiation penetration for the whole measuring time play a role to supplement indoor environment mutually.

복합 구조형 배수 배관재의 소음 및 결로 특성에 관한 연구 (A Study on the Noise and Condensation Characteristics of Complex Structure Drainage Pipe Materials)

  • 김재돌
    • 동력기계공학회지
    • /
    • 제20권5호
    • /
    • pp.72-77
    • /
    • 2016
  • The present study investigates noise and condensation characteristics of polyvinyl chloride (PVC), which is widely used for drainage piping materials, complex double structure by comparing to those of PVC single structure piping materials. In addition, effects of insulation on drainage noise has been measured experimentally. As the results of the experiments, noise reduction effect of PVC complex double structure is superior to that of PVC single structure in terms of elbow and vertical piping materials which are employed for drainage pipes of toilet bowls and bathtub. The insulation barely have effect on the noise reduction in case of the PVC single structure since there is almost no changes in noise occurrence even though the insulation is applied on both elbow and vertical piping materials. Temperature differences between inside and outside of the pipes have been measures for the PVC single and complex double structures as well. In consequence, outside temperature of the PVC complex double structure is higher than that of the PVC single structure. The condensation occurrence time of the PVC complex double structure shows a distinct difference from that of the PVC single structure, thus, the PVC complex double structure has outstanding effect on preventing the condensation.

폴리 게이트의 양자효과에 의한 Double-Gate MOSFET의 특성 변화 연구 (Poly-gate Quantization Effect in Double-Gate MOSFET)

  • 박지선;이승준;신형순
    • 대한전자공학회논문지SD
    • /
    • 제41권8호
    • /
    • pp.17-24
    • /
    • 2004
  • Density-gradient 방법을 이용하여 게이트의 양자효과가 double-gate MOSFET의 단채널 효과에 미치는 영향을 2차원으로 분석하였다. 게이트와 sidewall 산화막 경계면에서 발생하는 2차원 양자공핍 현상에 의하여 게이트 코너에 큰 전하 다이폴이 형성되며 subthreshold 영역에서 다이폴의 크기가 증가하고 classical 결과에 비하여 전자 농도와 전압 분포가 매우 다름을 알 수 있었다. Evanescent-nude분석을 통하여 게이트의 양자효과가 소자의 단채널 효과를 증가시키며 이는 기판에서의 양자효과에 의한 영향보다 크다는 것을 확인하였다. 양자효과에 의하여 게이트 코너에 형성되는 전하 다이폴이 단채널 효과를 증가시키는 원인임을 밝혔다.

전기습윤 현상에서의 선장력과 전기 이중층의 영향에 대한 해석 (Analysis of Effects of Line Tension and Electrical Double Layers on Electrowetting Phenomenon)

  • 정상국;강관형;이정묵;강인석
    • 대한기계학회논문집B
    • /
    • 제27권7호
    • /
    • pp.956-962
    • /
    • 2003
  • The Lippmann-Young equation has been widely used in electrowetting to predict the contact-angle change of a droplet on a insulating substrate with respect to the externally-applied electrical voltage. The Lippmann-Young equation is derived by assuming a droplet as a perfect conductor, so that the effect of the electrical double layer and the line tension are not taken into account. The validity of the assumption has never been checked before, systematically. In the present investigation, a modified Lippmann-Young equation is derived taking into account of the effect of the electrical double layer and the line tension. To assess their influence on contact-angle change in electrowetting, the electrostatic field around the three-phase contact line is analyzed by solving the Poisson-Boltzmann equation numerically. The validity of the numerical methods is verified by using the past theoretical results on the electrostatic field around a wedge-shaped geometry, which shows fairly good agreement. The results of the present investigation clearly indicate that the effect of the electrical double layer and the line tension is negligible for a millimeter-sized droplet. On the other hand, for a micron-sized droplet, the effect of the line tension can become a dominating factor which controls the contact-angle change in electrowetting.

Pre Calendering Effect after Primary Coating in Double Coating System(1)

  • 김병수
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2006년도 춘계학술발표논문집
    • /
    • pp.124-131
    • /
    • 2006
  • It is well known that smoother surface in substrate for coating or converting can obtain better results. Generally paper substrate is taking machine calendar process in papermaking system to give more uniformity and to get better coating runnability. This paper was prepared to find better idea for obtaining smoother surface after precalendering precoated paper as a substrate of double coating system. It was shown precalendering had effect on roughness improvement for precoating layer but was difficult to say it was effected to supercalendering results for double coating. The porosity and ink evaluation with precalendered double coated paper is needed to identify more essential clue for precalendering effect.

  • PDF