• Title/Summary/Keyword: Dose-response

Search Result 2,332, Processing Time 0.028 seconds

Development and Performance of a Hand-Held CZT Detector for In-Situ Measurements at the Emergency Response

  • Ji, Young-Yong;Chung, Kun Ho;Kim, Chang-Jong;Yoon, Jin;Lee, Wanno;Choi, Geun-Sik;Kang, Mun Ja
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.87-91
    • /
    • 2016
  • Background: A hand-held detector for an emergency response was developed for nuclide identification and to estimate the information of the ambient dose rate in the scene of an accident as well as the radioactivity of the contaminants. Materials and Methods: To achieve this, the most suitable sensor was first selected as a cadmium zinc telluride (CZT) semiconductor and the signal processing unit from a sensor and the signal discrimination and storage unit were successfully manufactured on a printed circuit board. Results and Discussion: The performance of the developed signal processing unit was then evaluated to have an energy resolution of about 14 keV at 662 keV. The system control unit was also designed to operate the CZT detector, monitor the detector, battery, and interface status, and check and transmit the measured results of the ambient dose rate and radioactivity. In addition, a collimator, which can control the inner radius, and the airborne dust sampler, which consists of an air filter and charcoal filter, were developed and mounted to the developed CZT detector for the quick and efficient response of a nuclear accident. Conclusion: The hand-held CZT detector was developed to make the in-situ gamma-ray spectrometry and its performance was checked to have a good energy resolution. In addition, the collimator and the airborne dust sampler were developed and mounted to the developed CZT detector for a quick and efficient response to a nuclear accident.

The Role of Porta Hepatis Irradiation in Relieving Malignant Obstructive Jaundice (악성 폐쇄성 황달 환자에 있어서 간문에 대한 방사선치료의 역할)

  • Yang, Kwang-Mo;Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.8 no.1
    • /
    • pp.79-84
    • /
    • 1990
  • We have analysed 13 patients with malignant obstructive jaundice due to metastasis who were treated with local radiation therapy to the area of porta hepatis at the Radiation Therapy Department of Paik Hospital attached to the Inje University between 1984 and 1988. A good response was observed in 6 out of 7 evaluable paitens receiving a total radiation dose ranging from 2600 to 5480 cGy in 2.6 to 6 weeks. A complete response was noted in 5 patients, a partial response in 1 patient, and no response in 1 patient. The overall median survival for 13 patients was 3 months. But two patients lived more than a year without recurrence of jaundice. Moderate dose, localized field radiation therapy appears to the beneficial in relieving obstructive jaundice and gives a good symptomatic relief.

  • PDF

Evaluation of Nivolumab Use and Factors related to Treatment Outcomes in a Cancer Center of a Top Tier General Hospital (상급종합병원 암센터에서 Nivolumab 사용평가와 치료성과에 미치는 영향인자)

  • Eoum, Gohye;Cho, Yoonsook;Rhie, Sandy Jeong
    • Korean Journal of Clinical Pharmacy
    • /
    • v.28 no.2
    • /
    • pp.88-94
    • /
    • 2018
  • Background: We strived to evaluate the status of nivolumab use and associated factors on the clinical efficacy of the drug. Methods: The study was retrospectively conducted in patients who had been administered nivolumab at least once at the cancer center of Seoul National University Hospital from June 2015 to April 2017. Data were collected from electronic medical records. A medication-use evaluation was performed based on the American Society of Health-System Pharmacists mediation-use guidelines. Results: Sixty-six of the 74 patients (89.2%) showed indications approved for nivolumab use by the Korean Ministry of Food and Drug Safety (MFDS; n=55) or the US Food and Drug Administration (FDA; n=11). Approximately 73.0% of the patients were administered the approved dose of 3 mg/kg but 25.7% were administered an unapproved fixed dose of 100 mg. The overall response rate was 21.7%, and the response rate of non-small cell lung cancer patients, who accounted for the largest number of indications, was 18.8%. Adverse reactions were found in 90.1% of the patients and were mostly mild (86%). The expression of programmed death-ligand 1 (PD-L1) was analyzed as a factor affecting treatment response (p=0.028, odds ratio [OR]=11.331). Conclusion: PD-L1 expression was found to affect treatment response. However, caution is required while using an unapproved dosage and in the absence of monitoring for effectiveness and safety. Therefore, an effective protocol or instruction manual for the proper use of nivolumab should be considered.

Enhanced Release of Cholecystokinin by Dietary Components in Chicks (사료성분에 의한 닭의 혈중 Cholecystokinin 농도의 상승)

  • 양성익
    • Korean Journal of Poultry Science
    • /
    • v.17 no.2
    • /
    • pp.83-91
    • /
    • 1990
  • The effect of dietary components on cholecystokinin (CCK) release into plasma was investigated in chicks by feeding a meal through a stomach tube, followed by the CCK determination with specific CCK-8 antibody. In experimental 1, the results showed that both isolated soya protein and an amino acid mixture simulating the amino acid composition of the soya protein increased the release of CCK, though to a lesser extent with a delayed response in the former, when added to a protein-free diet. Among amino acids added singly to the protein-free diet, phenylalanine was more efficient than arginine and valine, exerting a response almost identical to the complete amino acid mixture. In experimental 2 and 3, by feeding the protein diets supplemented SBTI, piasma CCK level was promptly increased and this response was in a dose dependent fashion during the measurement time, being higher at 1000 than at 100 mg/kg diet. Since the SBTI supplementation did not affect crop emptying rates significantly, it was concluded that SBTI by itself enhanced CCK release into circulation.

  • PDF

Enhancing immune responses to inactivated foot-and-mouth virus vaccine by a polysaccharide adjuvant of aqueous extracts from Artemisia rupestris L.

  • Wang, Danyang;Yang, Yu;Li, Jinyu;Wang, Bin;Zhang, Ailian
    • Journal of Veterinary Science
    • /
    • v.22 no.3
    • /
    • pp.30.1-30.15
    • /
    • 2021
  • Background: New-generation adjuvants for foot-and-mouth disease virus (FMDV) vaccines can improve the efficacy of existing vaccines. Chinese medicinal herb polysaccharide possesses better promoting effects. Objectives: In this study, the aqueous extract from Artemisia rupestris L. (AEAR), an immunoregulatory crude polysaccharide, was utilized as the adjuvant of inactivated FMDV vaccine to explore their immune regulation roles. Methods: The mice in each group were subcutaneously injected with different vaccine formulations containing inactivated FMDV antigen adjuvanted with three doses (low, medium, and high) of AEAR or AEAR with ISA-206 adjuvant for 2 times respectively in 1 and 14 days. The variations of antibody level, lymphocyte count, and cytokine secretion in 14 to 42 days after first vaccination were monitored. Then cytotoxic T lymphocyte (CTL) response and antibody duration were measured after the second vaccination. Results: AEAR significantly induced FMDV-specific antibody titers and lymphocyte activation. AEAR at a medium dose stimulated Th1/Th2-type response through interleukin-4 and interferon-γ secreted by CD4+ T cells. Effective T lymphocyte counts were significantly elevated by AEAR. Importantly, the efficient CTL response was remarkably provoked by AEAR. Furthermore, AEAR at a low dose and ISA-206 adjuvant also synergistically promoted immune responses more significantly in immunized mice than those injected with only ISA-206 adjuvant and the stable antibody duration without body weight loss was 6 months. Conclusions: These findings suggested that AEAR had potential utility as a polysaccharide adjuvant for FMDV vaccines.

A Synthetic Analog of Resveratrol Inhibits the Proangiogenic Response of Liver Sinusoidal Cells during Hepatic Metastasis

  • Olaso, Elvira;Benedicto, Aitor;Lopategi, Aritz;Cossio, Fernando P.;Arteta, Beatriz
    • Biomolecules & Therapeutics
    • /
    • v.30 no.2
    • /
    • pp.162-169
    • /
    • 2022
  • We utilized Fas21, a resveratrol analog, to modulate the function of hepatic stellate cells (HSCs) and liver sinusoidal endothelial cells (LSECs) during the angiogenic phase of murine liver metastasis by B16 melanoma and 51b colorectal carcinoma. Preangiogenic micrometastases were treated with Fas21 (1 mg/kg/day) or vehicle during the development of intra-angiogenic tracts. Mice treated with Fas21 showed reduced liver tumor foci in both liver metastasis models. Micrometastases were classified immunohistochemically, as well as according to their position coordinates and connection to local microvasculature. The volume of liver occupied by sinusoidal-type foci, containing infiltrating angiogenic capillaries, decreased by ~50% in Fas21-treated mice compared to vehicle-treated ones in both tumor metastasis models. The volume of portal foci, containing peripheral neoangiogenesis within a discontinuous layer of myofibroblasts, was similar in all experimental groups in both tumor metastasis models, but displayed enhanced necrotic central areas devoid of angiogenesis following Fas21 treatment. As a result, sinusoidal tumors from mice treated with Fas21 showed a 50% reduction in desmin(+)/asma(+) HSCs and CD31(+) vessel density, and a 45% reduction in intrametastatic VEGF mRNA compared with sinusoidal tumors from vehicle-treated mice. Necrotic portal metastases increased 2-4-fold in treated mice. In vitro, Fas21 reduced VEGF secretion by HSCs and 51b cells dose-dependently. Additionally, HSCs migration in response to tumor soluble factors was dose-dependently diminished by Fas21, as was LSEC migration in response to HSCs and tumor soluble factors. Resveratrol analog Fas21 inhibits the proangiogenic response of HSCs and LSECs during the development of murine liver metastasis.

The Result of Radiation Therapy of Superior Vena Cava Syndrome (상행정맥 증후군의 방사선 치료 성적)

  • Cho Chong Hee;Kim Hyun Soon;Hong Seong Eon;Ahn Chi Yul
    • Radiation Oncology Journal
    • /
    • v.4 no.1
    • /
    • pp.67-73
    • /
    • 1986
  • To access the result of radiation therapy for 8 years experiences, 21 patients who were treated with superior vena cava syndrome had been analysed according to dose fractionation and total dose. The results are as follows; 1. In high fractionate dose group, six of eleven patients $(54.5\%)$ exhibited relief of symptoms in 1-2 days, and additional three patients of nine $(81.7\%)$ within 34 days, while standard fractionated dose treatment is not effective to achieve initial relief of symptoms. 2. Graded response by total dose was correlated with total dose rather than dose fractionation. 3. Overall one year survival rate with superior vena cava syndrome was $9.1\%$ and mean survival was 4.2 months.

  • PDF

A Study on Retrospective of External Radiation Exposure Dose by Optically Stimulated Luminescence of Smart Chip Card (스마트칩 카드을 이용한 광 자극 발광 특성 연구)

  • Park, Sang-Won;Yoo, Se-Jong
    • Journal of radiological science and technology
    • /
    • v.42 no.5
    • /
    • pp.379-385
    • /
    • 2019
  • Radiation is used for various purposes such as cancer therapy, research of industrial and drugs. However, in case of radiation accidents such as terrorism, collapsing nuclear plant by natural disasters like Fukushima in 2011, very high radiation does expose to human and could lead to death. For this reason, many people are concerning about radiation exposures. Therefore, assessment and research of retrospective radiation dose to human by various path is an necessary task to be continuously developed. Radiation exposure for workers in radiation fields can be generally measured using a personal exposure dosimeter such as TLD, OSLD. However, general people can't be measured radiation doses when they are exposed to radiation. And even if radiation fields workers, when they do not in possession personal dosimeter, they also can't be measured exposure dose immediately. In this study, we conduct retrospective research on reconstruction of dose after exposure by using smart chip card of personal items through Optically Stimulated Luminescence (OSL). The OSL signal of smart chip card shows linear response from 0.06 Gy to 15 Gy and results of fading rate 45 %, 48% for 24 and 48 hours due to the natural emission of radiation in sample, respectively. The minimum detectable limit (MDD) was 0.38 mGy. This values are expected to use as correction values for reconstruction of exposure dose.

Application of Modified Mupit for the Recurrent Vulva Cancer in Brachytherapy

  • Kim, Jong-Sik;Jung, Chun-Young;Oh, Dong-Gyoon;Song, Ki-Won;Park, Young-Hwan
    • 대한방사선치료학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.23-26
    • /
    • 2005
  • Introduction: To evaluate whether modified MUPIT applicator can effectively eradicate recurrent tumor in uterine cervix cancer and reduce rectal complication after complete radiation treatment. Methods and Materials: Modified MUPIT applicator basically consists of an acrylic cylinder with flexible brain applicator , an acrylic template with a predrilled array of holes that serve as guides for interstitial needles and interstitial needles. CT scan was performed to determine tumor volume and the position of interstitial needles. Modified MUPIT applicator was applied to patient in operation room and the accuracy for position of interstitial needles in tumor volume was confirmed by CTscan. Brachytherapy was delivered using modified MUPIT applicator and RALS (192-Ir HDR) after calculated computer planning by orthogonal film. The daily dose was 600cGy and the total dose was delivered 3000cGy in tumor volume by BID. Rectal dose was measured by TLD at 5 points so that evaluated the risk of rectal complication. Result: The application of modified MUPIT applicator improved dramatically dose distributions in tumor volume and follow-up of 3 month for this patient was clinically partial response without normal tissue complication, Rectal dose was measured 34.1cGy, 57.1cGy, 103.8cGy, 162.7cGy, 165.7cGy at each points, especially the rectal dose including previous EBRT and ICR was 34.1cGy, 57.1cGy Conclusion: Patients with locally recurrent tumor in uterine cervix cancer treated with modified MIUPIT applicator can expect reasonable rates of local control. The advantages of the system are the fixed geometry Provided by the template and cylinders, and improved dose distributions in irregular tumor volume without rectal complication

  • PDF

A Study on the Dose Assessment Methodology Using the Probabilistic Characteristics of TL Element Response (확률분포 특성을 이용한 열형광선량계의 선량평가방법에 관한 연구)

  • Cho, Dae-Hyung;Oh, Jang-Jin;Han, Seung-Jae;Na, Seong-Ho;Hwang, Won-Guk;Lee, Won-Keun
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.123-138
    • /
    • 1998
  • Characteristics of element responses of Panasonic UD802 personnel dosimeters in the X, ${\beta}$, ${\gamma}$, ${\gamma}/X$, ${\gamma}/{\beta}$ and ${\gamma}$/neutron mixed fields were assessed. A dose-response algorithm has been developed to decide the high probability of a radiation type and energy by using the distribution in all six ratios of the multi-element TLD. To calculate the 4-element response factors and ratios between the elements of the Panasonic TLDs in the X, $\beta$, and $\gamma$ radiation fields, Panasonic’s UD802 TLDs were irradiated with KINS’s reference irradiation facility. In the photon radiation field, this study confirms that element-3 (E3) and element-4 (E4) of the Panasonic TLDs show energy dependent both in low- and intermediate-energy range, while element-1 (E1) and element-2 (E2) show little energy dependency in the entire whole range. The algorithm, which was developed in this study, was applied to the Panasonic personnel dosimetry system with UD716AGL reader and UD802 TLDs. Performance tests of the algorithm developed was conducted according to the standards and criteria recommended in the ANSI N13.11. The sum of biases and standard deviations was less than 0.232. The values of biases and standard deviations are distributed within a triangle of a lateral value of 0.3 in the ordinate and abscissa, With the above algorithm, Panasonic TLDs satisfactorily perform optimum dose assessment even under an abnormal response of the TLD elements to the energy imparted. This algorithm can be applied to a more rigorous dose assessment by distinguishing an unexpected dose from the planned dose for the most practical purposes, and is useful in conducting an effective personnel dose control program.

  • PDF