• Title/Summary/Keyword: Dose-response

Search Result 2,341, Processing Time 0.025 seconds

Identification of troglitazone responsive genes: induction of RTP801 during troglitazone-induced apoptosis in Hep 3B cells

  • Kim, Jin-Oh;Kim, Ji-Young;Kwack, Mi-Hee;Hong, Su-Hyung;Kim, Moon-Kyu;Kim, Jung-Chul;Sung, Young-Kwan
    • BMB Reports
    • /
    • v.43 no.9
    • /
    • pp.599-603
    • /
    • 2010
  • Troglitazone is an anti-diabetic agent that improves hyperglycemia by reducing peripheral insulin resistance in type II diabetic patients. Troglitazone has been shown to cause growth inhibition of various normal and cancerous cells. However, the molecular mechanism by which troglitazone affects the growth of these cancer cells remains unclear. Here, we report that troglitazone treatment of Hep 3B human hepatocellular carcinoma cells resulted in dose-dependent growth inhibition. Analysis of cell cycle distribution by flow cytometry showed that the number of apoptotic cells was increased in a dose-dependent manner in response to troglitazone treatment. cDNA microarray analysis showed a number of differentially expressed genes in response to troglitazone. Among the upregulated genes, hypoxia-inducible factor 1 (HIF-1)-responsive RTP801 was induced in a dose-dependent manner. We also observed HIF-1 accumulation by immnocytochemistry after troglitazone treatment. These results strongly suggest that RTP801 might be involved in troglitazone-induced apoptosis in Hep 3B cells.

A review of two theories of motion sickness and their implications for tall building motion sway

  • Walton, D.;Lamb, S.;Kwok, Kenny C.S.
    • Wind and Structures
    • /
    • v.14 no.6
    • /
    • pp.499-515
    • /
    • 2011
  • Low-frequency building vibration is known to induce symptoms of motion sickness in some occupants. This paper examines how the adoption of a theory of motion sickness, in conjunction with a dose-response model might inform the real-world problem of managing and designing standards for tall building motion sway. Building designers require an understanding of human responses to low-dosage motion that is not adequately considered by research into motion sickness. The traditional framework of Sensory Conflict Theory is contrasted with Postural Instability Theory. The most severe responses to motion (i.e., vomiting) are not experienced by occupants of wind-excited buildings. It is predicted that typical response sets to low-dosage motion (sleepiness and fatigue), which has not previously been measured in occupants of tall-buildings, are experienced by building occupants. These low-dose symptoms may either be masked from observation by the activity of occupants or misattributed to the demands of a typical working day. An investigation of the real-world relationship between building motion and the observation of low-dose motion sickness symptoms and a degradation of workplace performance would quantify these effects and reveal whether a greater focus on designing for occupant comfort is needed.

Influence and analysis of a commercial ZigBee module induced by gamma rays

  • Shin, Dongseong;Kim, Chang-Hwoi;Park, Pangun;Kwon, Inyong
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1483-1490
    • /
    • 2021
  • Many studies are undertaken into nuclear power plants (NPPs) in preparation for accidents exceeding design standards. In this paper, we analyze the applicability of various wireless communication technologies as accident countermeasures in different NPP environments. In particular, a commercial wireless communication module (WCM) is investigated by measuring leakage current and packet error rate (PER), which vary depending on the intensity of incident radiation on the module, by testing at a Co-60 gamma-ray irradiation facility. The experimental results show that the WCMs continued to operate after total doses of 940 and 1097 Gy, with PERs of 3.6% and 0.8%, when exposed to irradiation dose rates of 185 and 486 Gy/h, respectively. In short, the lower irradiation dose rate decreased the performance of WCMs more than the higher dose rate. In experiments comparing the two communication protocols of request/response and one-way, the WCMs survived up to 997 and 1177 Gy, with PERs of 2% and 0%, respectively. Since the request/response protocol uses both the transmitter and the receiver, while the one-way protocol uses only the transmitter, then the electronic system on the side of the receiver is more vulnerable to radiation effects. From our experiments, the tested module is expected to be used for design-based accidents (DBAs) of "Category A" type, and has confirmed the possibility of using wireless communication systems in NPPs.

Characterization of the drug receptors responsible for intestinal contraction in Israeli carp (이스라엘잉어 장관 수축에 관여하는 약물수용체에 관한 연구)

  • Yun, Hyo-in;Han, Kyong-oh;Park, Seung-chun;Cho, Joon-hyoung;Oh, Tae-kwang
    • Korean Journal of Veterinary Research
    • /
    • v.34 no.3
    • /
    • pp.447-456
    • /
    • 1994
  • In order to elucidate the characterization of receptors involved in inestinal motility of Israeli carp, spontaneously contracting Israeli carp intestinal preperations were prepared and mounted in the organ chambers for contraction traicings using a polygraph. Various contractile agonists were treated and their dose-response curves were constructed. $EC_{50}$ values$(pD_2)$ of each agonist on specific receptors, $pA_2$ values of competitive antagonists against some agonists, and $K_1$, values of noncompetitive antagonists against some agonists were analyzed for characterization of receptors related with the intestinal contraction. Results obtained through the experiments were summarized as follows: 1. Acetylcholine(ACh) exhibited biphasic dose-response curves: initial ACh-induced dose dependent contractions were observed in pM levels but followed by decreased response in in-between concentration levels. Dose dependent contractions reappeared in ${\mu}M$ level. The peaks in pM and ${\mu}M$ levels appeared in $10^{-13}M$ and $3{\times}10^{-5}M$, respectvely. 2. Carbachol(CaCh) exhibited dose dependent contractions from $10^{-9}M$ to $10^{-5}M$, and its $pD_2$ values were higher than those of ACh($5.60{\pm}0.11$). ACh and CaCh exhibited equiactive contractions. Nicotine had no effects on contractile responses of Israeli carp intestine. 3. ACh-induced responses were inhibited by atropine($K_1:7{\times}10^{-8}M$), a muscarinic antagonist, in a non-competitive manner. But CaCh-induced responses were inhibited by both antimuscarinic atropine($pA_2:9.52{\pm}0.14$) and selective $M_2$ antagonistic 4-DAMP($pA_2:8.16{\pm}0.09$), in competitive manners. Nicotine receptor antagonistic decamethonium and hexamethonium had no effects on ACh-and CaCh-induced contractions. Therefore, the cholinergic receptor related to intestinal motility of Israeli carp was assumed as $M_2$ type. 4. In Israeli carp intestine, 5-HT (serotonin) exhibited dose dependent contractions in concentration range from $10^{-8}M$ to $10^{-5}M$. The maximal responses, however, were corresponded to about 50% of those of ACh or CaCh. 5-HT induced contractions were inhibited by $5-HT_2$ antagonistic ketanserin ($K_1: 7.8{\times}10^{-4}M$) in a non-competitive manner, but not by both of anti $5-HT_1$, spiperone and anti $5-HT_3$, MDL-72222. Hence, $5-HT_2$ receptors are suggested to be existed in Isreli carp intestine.

  • PDF

Cytogenetic Radiation Adaptive Response Assessed by Metaphase Analysis and Micronuclei Test in Human Lymphocytes and Mouse Bone Marrow Cells (인체말초혈액 림프구와 마우스골수세포에서 중기염색체 분석법과 미소핵검사법을 이용한 방사선적응반응 평가)

  • Min, Jung-Jun;Bom, Hee-Seung;Lee, Seung-Yeon;Choi, Keun-Hee;Jeong, Hwan-Jeong;Song, Ho-Cheon;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.6
    • /
    • pp.525-533
    • /
    • 1998
  • Purpose: Radiation adaptive response in human peripheral lymphocytes and mouse bone marrow cells was investigated using both metaphase analysis and micronucleus assay. We assessed the correlation between both tests. Materials and Methods: Two groups of the human peripheral lymphocytes and mouse bone marrow cells were exposed to low dose (conditioning dose, 0,18 Gy) or high dose (challenging dose, 2 Gy) ${\gamma}$-rays. The other 4 groups were exposed to low dose followed by high dose after several time intervals (4, 7, 12, and 24 hours, respectively). The frequencies of chromosomal aberrations in metaphase analysis and micronuclei in micronucleus assay were counted. Results: Chromosomal aberrations and micronuclei of preexposed group were lower than those of the group only exposed to high dose radiation. Maximal reduction in frequencies of chromosomal aberrations were observed in the group to which challenging dose was given at 7 hour after a conditioning dose (p<0.001). Metaphase analysis and micronucleus assay revealed very good correlation in both human lymphocytes and mouse bone marrow cells (r=0.98, p<0.001 ; r=0.99, p=0.001, respectively). Conclusion: Radiation adaptive response could be induced by low dose irradiation in both human lymphocytes and mouse bone marrow cells. There was a significant correlation between metaphase analysis and micronucleus assay.

  • PDF

Intraluminal High-Dose-Rate Brachytherapy for the Tumors of Gastrointestinal Tract (위장관 종양의 고선량율 강내 방사선치료)

  • Choi Byung Ock;Choi Ihl Bhong;Chung Su Mi;Kim In Ah;Choi Myoung Gyu;Chang Suk Kyun;Shinn Kyeong Sub
    • Radiation Oncology Journal
    • /
    • v.13 no.3
    • /
    • pp.243-252
    • /
    • 1995
  • Purpose : Intraluminal high dose rate brachytherapy is an accepted treatment for the tumors of GI tract. However, there is only some limited clinical data for intraluminal high dose rate brachytherapy for the tumors of GI tract. Materials and Methods : Between February 1991 and July 1993, 18 Patients who have the tumors of GI tract (esophageal cancer-8 cases, rectal cancer-10 cases) were treated with high dose rate Iridium-192 afterloading system (Microselectron-HDR, Nucletron CO, Netherland) at the department of therapeutic radiology, St. Mary's hospital, Catholic university medical college. Age range was 47-87 years with a mean a9e 71 years. All patients were treated with intraluminal high dose rate brachytherapy within two weeks after conventional external radiation therapy and received 3-5 Gy/fraction 3-4 times per week to a total dose 12-20 Gy (mean 17 Gy). Standard fractionation and conventional dose were delivered for external radiation therapy. Total dose of external radiation therapy ranged 41.4-59.4 Gy (mean 49.6 Gy). Median follow up was 19 months Results : The analysis was based on 18 patients, The complete response and partial response in esophageal cancer was similar (38%). Two year rates for survival and median survival were 13% and 10 months, respectively. Among 10 patients of rectal cancers, partial response was obtained in 6 patients (60%). There was no complete response in the patients with rectal cancer, but good palliative results were achieved in all patients. Conclusion : Although the number of patients was not large and the follow-up period was relatively short, these findings suggested that intraluminal high dose rate brachytherapy could be useful in the treatment of the patients with advanced tumors of GI tract.

  • PDF

Study on the annoyance response of subway station noise using jury evaluation test (청감실험을 통한 도시철도 승강장 소음의 성가심 반응에 대한 연구)

  • Kim, Dong-Jun;Kim, Deuk-Sung;Son, Jin-Hee;Chang, Seo-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.670-677
    • /
    • 2009
  • The purpose of this study is to reveal the quantitative dose-response relationship between the noise emitted in the platform of subway station and the public response. The noise measured in the platform of subway station was used for a jury test. In order to find the factors which influence annoyance response due to the platform noise, jurors were examined for the difference of the annoying response, interrelation of sound quality parameter and annoyance response. The platform noise level was 77.2$\sim$83.9 dBA and the most of passengers at the platform were highly annoyed. And screen door contributes to annoyance reduction of platform noise. The results from analyzing sound quality parameters shows that loudness and annoyance response have a high correlation coefficient.

  • PDF

Analgesic, Anti-inflammatory and Diuretic Activities of Pisonia grandis

  • Anbalagan, N.;Rajinikanth, K.N.;Gnanasam, S. Kishore;Leonard, J. Thomas;Balakrishna, K.;Ramachandran, S.;Sridhar, S.K.
    • Natural Product Sciences
    • /
    • v.8 no.3
    • /
    • pp.97-99
    • /
    • 2002
  • In the present study, Pisonia grandis leaves were extracted with chloroform and methanol. The extracts were vacuum dried to yield the respective chloroform (CE) and methanol extract (ME). CE and ME were evaluated for analgesic, anti-inflammatory (acute and chronic) and diuretic activity at 2 dose levels (250 and 500 mg/kg). Significant analgesic and anti-inflammatory activities were associated with CE and ME. CE at the dose level of 500 mg/kg was found to exhibit equivalent chronic anti-inflammatory activity as diclofenac at 50 mg/kg dose level. Significant diuretic activity was exhibited by ME. Graded dose response for all the activities were observed for the extracts.

Relationship between UV-induced MED and Perfusion Value Assessed by Laser Doppler Perfusion Imager (Laser Doppler Perfusion Imager (LDPI)로 측정한 자외선 조사부위의 혈류량과 최소 홍반량(MED)과의 상관관계)

  • Kim, Nam-Soo;Lee, Kyung-Hoon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.31 no.3 s.52
    • /
    • pp.259-263
    • /
    • 2005
  • The aim of the present study is to evaluate relationship between UV-induced MED and perfusion value assessed by Laser Doppler Perfusion Imager. In this study, A increasing linear relationship is seen between perfusion and dose (p<0.05). The dose-response curve show a steep slope in the case of lower MED values group after MED point, For higher MED group, increase with a gentle slope.

A Rapid Dose Assessment and Display System Applicable to PWR Accident (선량평가 및 Display시스템)

  • Moon, Kwang-Nam;Yook, Chong-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.13 no.2
    • /
    • pp.67-77
    • /
    • 1988
  • The necessity of developing a rapid dose assessment system has been emphasized for an effective emergency response of mitigation of off-site radiological consequences. A microcomputer program based on a rapid dose assessment model of the off-site radiological consequences is developed for various accdident sinarios for the Nuclear Power Plants in Korea. This model, which is consists of the user answering-question input format as a menu driven method and the output format of table and graphic types, is helpful to decision-making on Emergency Preparedness by being more rapidly able to implement the off-site dose assessment and to interpret the result.

  • PDF