본 연구에서는 진단용 X선 검사에서 환자에게 피폭되는 두부 및 사지를 다양한 선량 계산법을 통해 실측 선량과 비교 실험하였다. 또한 촬영 장비의 형태, 장비 설정조건, X선의 용량, X선관과 환자와의 거리, X선 후방산란차이 등을 고려한 새로운 계산 방법을 제시하여 피폭선량을 산출하였다. 그 결과 피부입사선량이 기존의 선량 계산법보다 실측과의 오차가 줄어들었으며, 환자가 피폭되는 선량을 쉽게 계산할 수 있었고 의료선량 평가가 이루어지게 되어 방사선 관련 종사자들의 의료 선량 관리가 더욱 수월해지는 계기가 될 것으로 사료된다.
At the investigations with 200 institutes for analysis of factor associated with radiographic conditions reduction of patient exposure dose during X-ray diagnosis, 170 institutes or $85\%$ answered. For estimation of exposure dose the entrance
Purpose: Superior orbital fissure syndrome is a rare neurological complex. Superior orbital fissure syndrome may result from a variety of inflammatory, infectious, neoplastic, iatrogenic, traumatic, vascular cause. The author report a patient who suffered from superior orbital fissure syndrome after inferior orbital wall reduction. Methods: A 26-year-old female suffered from inferior orbital wall fracture with inferior gaze limitation and orbital soft tissue herniation. On posttrauma 10 day, inferior orbital wall was reduced using endoscope and porous polyethylene ($Medpor^{(R)}$) was inserted. On immediate postoperation, she reported that extraocular movement was limited in almost any directions. She underwent exploration surgery to release the presence of extraocular muscle impingement. But, there was no observation of extraocular muscle impingement. On postoperative one day, high-dose steroid therapy was started to release superior orbital fissure syndrome which was defined in postoperative computed tomography. Results: After one month of high-dose steroid therapy, extraocular movement limitations improved progressively in all directions. In four months, extraocular movement recovered completely. Conclusion: Superior orbital fissure syndrome may occur after surgical procedure of orbital wall reduction. Prompt diagnosis and treatment with mega-dose corticosteroid is an effective option for avoiding disaster from compressive syndrome.
Radiation therapy (RT) has improved patient outcomes, but treatment-related complication rates remain high. In the conventional 2-dimensional and 3-dimensional conformal RT (3D-CRT) era, there was little room for toxicity reduction because of the need to balance the estimated toxicity to organs at risk (OARs), derived from dose-volume histogram data for organs including the lung, heart, spinal cord, and liver, with the planning target volume (PTV) dose. Intensity-modulated RT (IMRT) is an advanced form of conformal RT that utilizes computer-controlled linear accelerators to deliver precise radiation doses to the PTV. The dosimetric advantages of IMRT enable better sparing of normal tissues and OARs than is possible with 3D-CRT. A major breakthrough in the treatment of esophageal cancer (EC), whether early or locally advanced, is the use of proton beam therapy (PBT). Protons deposit their highest dose of radiation at the tumor, while leaving none behind; the resulting effective dose reduction to healthy tissues and OARs considerably reduces acute and delayed RT-related toxicity. In recent studies, PBT has been found to alleviate severe lymphopenia resulting from combined chemo-radiation, opening up the possibility of reducing immune suppression, which might be associated with a poor prognosis in cases of locally advanced EC.
본 연구에서 Phantom에 고 밀도 물질이 삽입 된 CT 영상을 재구성 하여 방사선 치료 계획 시 선량 분포에 대한 평가를 하고자 하였다. Gammex 467 Tissue Characterization Phantom을 사용하여 인체 조직과 유사한 영상을 획득하였고 Titanium을 삽입하여 금속물로 인한 인공허상을 발생시켜 영상을 획득하였다. 획득한 영상은 Metal Artifact Reduction for Orthopedic Implants (O-MAR)를 이용하여 영상을 재구성 하였고 전산화 치료계획 시스템을 이용하여 체적을 분석 하고 선량 분포를 추출하였다. $MapCHECK^{TM}$을 이용하여 선형가속기의 광자선 선량 분포를 측정하여 계획한 선량 분포와 비교 분석 하였다. 비교 분석 결과 Titanium으로 인한 인공허상이 발생 되었을 때 O-MAR를 적용한 체적은 BR-12 Breast는 16.8 % 그리고 LV 1 Liver는 40.2 % 증가하였고 선량 분포는 O-MAR를 적용하기 전의 선량 분포 보다 1.4 에서 1.6 % 높게 나타났다. 결론적으로 금속물로 발생된 인공허상 O-MAR를 적용하여 가능한 제거하고 치료계획에 이용해야 오류를 줄일 수 있을 것으로 사료된다.
Recently, new gamma camera systems enabling low radiation dose imaging have been developed. We reviewed the recent development of these low dose gamma camera systems including high sensitivity detectors, device structures, noise reduction filters, efficient image reconstruction algorithms, low dose protocols, and so on. It is expected that further technological advances reduce both radiation dose and imaging time in gamma camera imaging especially for radiation-sensitive patients such as pediatric patients.
심혈관 촬영 시 선량감소를 위해 실무자가 조절 가능한 기하학적 특성을 살펴보고, 각 특성에 따른 유효선량을 비교해 보았다. 인체 모형 팬텀을 이용하여 투시촬영과 영화촬영을 시행하였고, 선량의 측정은 심혈관 장치의 DAP meter를 이용하여 DAP 값을 유효선량으로 환산하였다. 먼저 영화촬영은 투시촬영에 비해 기하학적 특성 전반에 걸쳐서 선량이 약 6-7배 높았다. FPS mode에 따른 선량은 FPS를 낮게 설정할수록 선량이 70%까지 감소하였다. 선관 각도에 따른 선량은 LAO $45^{\circ}$+Caudal $30^{\circ}$이 가장 높게 측정되었고, 조사야 조절장치를 많이 적용할수록 선량은 감소하였다. X-선관과 영상증배관의 거리가 10 cm 멀어질수록 투시촬영과 영화촬영에서 각각 선량이 25-35%까지 증가하였다. FOV가 확대될수록 선량이 1.21-2배 증가하였고, 테이블과 영상증배관 거리가 10cm 멀어질수록 선량은 1.11-1.25배 까지 증가하였다. 따라서 본 연구에서 실험한 기하학적 특성인 FPS mode, 선관 각도, 조준기, 선관과 영상증배관 거리, 테이블과과 영상증배관 거리, FOV 영상 확대 등은 중재적 시술 시 실무자가 수시로 조절 가능한 인자이며, 각 특성에 따라 선량 감소 효과를 기대할 수 있다.
최근 임상에서 사용하고 있는 128채널 MDCT의 복부 및 골반부 촬영 시 생식선 차폐 선량관리 자료로 활용하기 위하여 생식선의 피폭선량과 생식선 차폐 시 피폭선량을 측정하고 획득영상을 평가하였다. 평가한 결과 복부 MDCT 검사시생식선 차폐기구를 사용하지 않았을 경우에서 $16.5{\pm}0.5$ mGy를 나타냈으며, 대($650m^2$)크기의 차폐체를 사용하였을 경우 $7.5{\pm}0.3$ mGy로 측정되어 54%의 생식선 피폭선량 감소효과를 보였다. 골반부 MDCT 검사시 생식선 차폐기구를 사용하지 않았을 경우에서 $9.5{\pm}0.3$ mGy, 대($650m^2$)크기의 차폐체를 사용하였을 경우 $2.8{\pm}0.2$ mGy로 나타나 70% 의 생식선 피폭선량 감소효과를 보였다. MDCT를 이용한 검사 시 생식선 차폐기구 사용 유, 무에 따라 영상을 획득하여 Likert 5점 척도로 분석한 결과 복부 영상에서는 4.1점으로 동일한 결과를 보였다. 또한 골반부 검사에서는 생식선 차폐기구 사용하였을 때 1.2점, 생식선 차폐기구 사용하지 않았을 때 4.1점으로 나타났다. 이상의 결과에서 복부 128-MDCT 검사 시 생식선 차폐기구를 사용하여 영상의 질 저하 없이 영상을 획득하고 피폭선량을 감소하여야 할 것으로 사료된다.
We can and must improve the diagnostic images using available knowledge and technology. At the same time we must strive to reduce the patient's integral and entrance radiation dose. Reducing the integral dose to the patient during the radiologic procedure is a primary concern of the patient, especially the pediatric patient, the radiologist and the technologist. A 100cm focal film distance generally is used for most over-table radiography. The early x-ray tubes and screen film combinations required long exposures, which often resulted in motion artifacts. But nowaday, we have the generators and x-ray tubes that can deliver the energy necessary in a very short time and the receptors that can record the information just as rapidly. And, we performed this studies to evaluate the patient exposure dose and the image quality by increasing focal film distance in diagnostic radiography. There are many factors which affected to exposure factor, but we studied to verify of FFD increase, only. Effect of increasing the focal film distance to a 140 cm distance was tested as follows; 1. The focal film distances were set at 100, 120, and 140cm. 2. A 18cm acryl(tissue equivalent) phantom was placed on the table top. 3. An Capintec 192 electrometer with PM 05 ion chamber was placed at the entrance surface of the phantom, and exposure were made at each focal film distances. 4. The procedure was repeated in the same manner as above except the ion chamber was placed beneath the phantom at the film plane. 5. Exit exposure were normalize to 8mR for each portions of the experiment. Based on the success of the empirical measurements, a detailed mathematical analysis of the dose reduction was performed using the percent depth dose data. The results of this study can be summerized as followings ; 1) Increasing FFD from 100 cm to 140 cm, we would create a situation that would have a significant effect on the overall quality of radiograph and achive the 17.42% reduction of entrance dose and the 18.95% reduction of integral dose that the patient receives. 2) Thickness of Al step wedge for equal film density increased with the long distance. 3) Increasing FFD, Magnification of image was lowered. 4) Resolution of image also increased with the FFD. As the results described above, we strongly recommend using the long FFD to provide better information for our patients and profession in abdomen radiographic studies.
두부 CT 검사 시 일반적으로 검사 시 적용하는 스캔조건 및 알고리즘을 기준으로 선정 후 알고리즘 변경 적용을 통한 선량감소효과를 실험을 통해 알아보고자 하였다. 그 결과 선량감소효과는 관전압 보다 관전류 변화 시 의미가 있었으며, 인체 팬텀을 이용한 화질 평가는 Smooth 알고리즘적용 후 선량을 감소 시 Bone 알고리즘적용 후 선량을 감소 시 보다 상대적으로 화질 감소가 적었으며, 특히 Bone 알고리즘적용 시에는 평균 CT Number 또는 Pixel value의 편차가 상대적으로 크게 측정되었다. 즉 선량은 감소되고 화질은 유지하여 환자의 피폭 선량을 감소시키고 동일한 화질의 영상을 얻을 수 있는 조건은 Smooth 알고리즘 적용과 120 kVp, 160 mA라는 결과 값을 얻을 수 있었다. 이 때 선량은 약 28% 감소되며 평균 CT Number 또는 Pixel value도 오차가 상대적으로 적게 측정 되었다. 향 후 스캔조건 및 다양한 알고리즘 적용 후 그 결과를 검진 또는 추적검사 등으로 내원한 환자에게 적용하여 검사 한다면 환자 피폭선량 감소에 있어 매우 유용할 것으로 사료된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.