Abstract
Based on the scan conditions and algorithms that are generally applied during examinations during head CT examinations, the results of dose reduction through the application of algorithm changes were investigated through experiments. As a result, the dose reduction effect was more meaningful for the change of perfusion than for the tube voltage, and the quality evaluation using the brain phantom was relatively less reduced when the dose was reduced after the application of the Bone algorithm, especially for the application of the Bone algorithm, and the deviation of the mean CT number or Pixel value was measured relatively significantly. In other words, the conditions under which dose was reduced and quality was maintained to reduce the patient's exposure dose and obtain images of the same quality were obtained with the application of the Smooth algorithm and the resulting values of 120 kVp, 160 mA. At this point, doses were reduced by about 28%, and the mean CT number or Pixel value was also measured with relatively little error. If the results are applied to patients who visit the hospital for examination or follow-up after applying various algorithms and follow up scan conditions, the results are considered to be very useful in reducing patient exposure dose.
Keywords
Algorithm; kVp; mA; Image Quality; Radiation dose;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 I. S. Lee, M. C. Kim, Y. C. Nam D. K. Han, "Usefulness of Automatic Exposure Control for dose Reduction: in Neck Study Using Multi_detector Computed Tomography," Journal of Korean Society of Computed Tomographic Technology, Vol. 2 No. 1, pp. 7-12, 2010.
2 K. J. Park, M. C. Kim, D. K. Han, "A Study on Image Quality and Dose of CT Image Using Adaptive Statistical Iterative Reconstruction Algorithm," Journal of Korean Society of Computed Tomographic Technology, Vol. 12, No. 1, pp. 95-104, 2010.
3 M. J. Uhm, S. M. Cheong, H. J. Yoo. "The Evaluation of Comparison between Dose and image Quality using spiral mode and Flash spiral MODE According to Pitch of Head Angiography," Journal of Korean Society of Computed Tomographic Technology, Vol. 14 No. 1 pp. 85-93, 2012.
4 D. Y. Lee, Y. S. Jang, Y. B. Kim S. M. Lim, K. W. Lee, Y. G. Jo, "The Variation of the Dose and Noise of HRCT according to Tube Voltage in MDCT," Journal of Korean Society of Computed Tomographic Technology, Vol. 14, No. 1, pp. 103-110, 2012.
5 B. J. Kwon, Y. S. Kim, H. C. Rhim, "Three-phase Dynamic CT Findings of Liver Abscess: Related Factors with Multiple Layering Enhancement Pattern," Journal of the Korean Radiological Society, Vol. 44, No 1, pp. 69-75, 2001.   DOI
6 H. M. Yoo, J. S. Cho, K. S. Shin, "Usefulness of Helical CT for the Preoperative Evaluation of Small Advanced Gastric Cancer Mimicking as Early Gastric Cancer at Endoscopy," Journal of the Korean Radiological Society, Vol. 52, No. 6, pp. 385-393, 2005.   DOI
7 D. J. Kim, J. S. Yu, S. M. Lee, "Advanced Gastric Cancer: Differentiation of Borrmann Type versus Borrmann Type by Two-Phased Dynamic Multi-Detector Row CT with Use of the Water Filling Method," Journal of the Korean Radiological Society, Vol. 68, No. 2, pp. 117-124, 2013.   DOI
8 B. C. Yoo, D. C. Kwon, J. S. Lee, K. J. Jeon, S. H. Kim, Y. S. Kim, D. C. Kweon, "Comparison radiation dose of z-axis automatic tube current modulation technique with fixed tube current multi-detector row CT scanning of lower extremity venography," Journal of Radiation. Protection and Research," Vol. 32, No. 3, pp. 123-133, 2007.
9 Okumura M, Ota T, Tsukagoshi S, Katada K. New Method of Evaluating Edge-preserving Adaptive Filters for Computed Tomography(CT) : Digital Phantom Method. Japanese Journal of Radiological Technology, Vol. 7 No. 1, pp. 971-978, 2006.
10 H. J. Kim, J. H. Cho, C. S. Park, "Evaluation of Image Quality in Low Tube-Voltage Chest CT Scan" Journal of Radiation protection, Vol. 35, No. 4, pp. 135-141, 2010.
11 H. S. Yoon, Predict of Fracture Risk Rate According to Morphological Measuring of Proximal Femoral Part Using Dual Energy X-ray Absoptiometry. Journal of Korean Society of radiological technology, Vol. 25, No. 4, pp. 49-53, 2002.
12 S. J. Kim, S. W. Yoo, J. C. Kim, S. M. Noh, J. W. Park, A Study on the Segmentation of Kidney from the Non Enhanced CT Image : Journal of KIISE Vol. 27, No. 3, pp. 514-516, 2000.
13 M. D. Becker, Y. M. Berkmen, J. H. M. Austin, I. K. Mun, B. M. Romney, A. Rozenshtein, Lung Volumes before and after Lung Volume Reduction Surgery. Vol. 157, No. 6, pp. 1593-1599, 1998.   DOI
14 S. S. Hong, J. Huh, " Uses Edge Method, MTF Analyses of CT Equipment which Follows in Channel and Convolution Algorithm, Journal of Korean Society of Computed Tomography Technology, Vol. 13, No. 1, pp. 105-114, 2011.
15 H. S. Hwang, K. B. Lee, S. M. Choi, "Evaluation of Image Quality with the use of SAFIRE(Sinogram Affirmed Iterative Reconstruction) and ASIR(Adaptive Statistical Iterative Reconstruction) by changing Radiation Dose," Journal of Korean Society of Computed Tomographic Technology, Vol. 15, No. 1, pp. 215-221, 2013.