• Title/Summary/Keyword: Dose rate assessment

Search Result 178, Processing Time 0.027 seconds

Development of a Computer Code for Low-and Intermediate-Level Radioactive Waste Disposal Safety Assessment

  • Park, J.W.;Kim, C.L.;Lee, E.Y.;Lee, Y.M.;Kang, C.H.;Zhou, W.;Kozak, M.W.
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.1
    • /
    • pp.41-48
    • /
    • 2004
  • A safety assessment code, called SAGE (Safety Assessment Groundwater Evaluation), has been developed to describe post-closure radionuclide releases and potential radiological doses for low- and intermediate-level radioactive waste (LILW) disposal in an engineered vault facility in Korea. The conceptual model implemented in the code is focused on the release of radionuclide from a gradually degrading engineered barrier system to an underlying unsaturated zone, thence to a saturated groundwater zone. The radionuclide transport equations are solved by spatially discretizing the disposal system into a series of compartments. Mass transfer between compartments is by diffusion/dispersion and advection. In all compartments, radionuclides ate decayed either as a single-member chain or as multi-member chains. The biosphere is represented as a set of steady-state, radionuclide-specific pathway dose conversion factors that are multiplied by the appropriate release rate from the far field for each pathway. The code has the capability to treat input parameters either deterministically or probabilistically. Parameter input is achieved through a user-friendly Graphical User Interface. An application is presented, which is compared against safety assessment results from the other computer codes, to benchmark the reliability of system-level conceptual modeling of the code.

Assessment of Grid Sensitivity in the FDS Field Model to Simulate the Flame Propagation of an Electric Cable Fire (케이블 화재의 화염전파 해석을 위한 FDS 모델의 격자민감도 평가)

  • Kim, Sung-Chan;Lee, Seong-Hyuk
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.4
    • /
    • pp.30-35
    • /
    • 2008
  • The present study has been conducted to examine the effect of grid resolution on the predicted results for electric cable fire using pyrolysis model in FDS(Fire Dynamics Simulator, version 5). The grid independent test for different grid resolutions has been performed for a PE coating cable and the grid resolution is defined by the non-dimensional characteristic length of fire and mean grid size. The calculated maximum heat release rate and mean flame spread rate were almost constant for higher grid resolution of 20${\sim}$25 and the computing time for the grid resolution takes approximately 20hours to solve flame propagation with pyrolysis model. The geometrical simplification of a electric cable dose not greatly affect on the maximum heat release rate and flame spread rate and the rectangular approximation of cable shape gives acceptable result comparing with the round cable with stepwise grid.

Initial Risk Assessment of Acetanilide in OECD High Production Volume Chemical Program

  • Park, Hye-Youn;Park, Yoonho;Sanghwan Song;Kwon, Min-Jeoung;Koo, Hyun-Ju;Jeon, Seong-Hwan;Na, Jin-Gyun;Park, Kwangsik
    • Toxicological Research
    • /
    • v.18 no.1
    • /
    • pp.13-22
    • /
    • 2002
  • In Korea, 2,320 tonnes of acetanilide were mostly wed as intermediates for synthesis in phar-maceuticals or additives in synthesizing hydrogen peroxide, varnishes, polymers and rubber. Only small amount of 120 kg were wed as a stabilizer for hydrogen peroxide solution for hair colouring agents in 1998. Readily available environmental or human exposure data do not exist in Korea at the present time. However, potential human exposures from drinking water, food, ambient water and in work places are expected to be negligible because this chemical is produced in the closed system in only one company in Korea and the processing factory is equipped with local ventilation and air filtering system. Acetanilide could be distributed mainly to water based on EQC model. This substance is readily biodegradable and its bioaccumulation is low. Acute toxicity of acetanilide is low since the L $D_{50}$ of oral exposure in rats is 1,959 mg/kg bw. The chemical is not irritating to skin, but slightly irritating to the eyes of rabbits. horn repeated dose toxicity, the adverse effects in rats were red pulp hyperplasia of spleen, bone marrow hyperplasia of femur and decreased hemoglobin, hematocrit and mean corpuscular hemoglobin concentration. The LOAEL for repeated dose toxicity in rats was 22 mg/kg/day for both sexes. Acetanilide is not considered to be genotoxic. In a reproductive/developmental toxicity study, no treatment-related changes in precoital time and rate of copulation, impregnation, pregnancy were shown in all treated groups. The NOAELs for reproduction and developmental toxicity (off-spring toxicity) are considered to be 200 mg/kg bw/day and 67 mg/kg bw/day, respectively. Ecotoxicity data has been generated in a limited number of aquatic species of algae (72 hr- $E_{b}$ $C_{50}$; 13.5 mg/l), daphnid (48hr-E $C_{50}$ > 100 mg/l) and fish (Oryzias latipes, 96hr-L $C_{50}$; 100 mg/l). Form the acute toxicity values, the predicted no effect concentration (PNEC) of 0.135 mg/1 was derived win an assessment factor of 100. On the basis of these data, acetanilide was suggested as currently of low priority for further post-SIDS work in OECD.in OECD.D.

Toxicity Assessment of Phenanthrene using the Survival and Population Growth Rate of the Marine Rotifer, Brachionus plicatilis (해산로티퍼(Brachionus plicatilis)의 생존 및 개체군 성장률을 이용한 Phenanthrene의 독성평가)

  • Hwang, Un-Ki;Choi, Hoon;Jang, Soo-Jung;Heo, Seung;Lee, Ju-Wook
    • Korean Journal of Environmental Biology
    • /
    • v.35 no.4
    • /
    • pp.573-580
    • /
    • 2017
  • The oxicity assesment of Phenanthrene (PHE) has been investigated by using the rate (r) of survival and population growth in rotifer Brachionus plicatilis. The survival rate was determined after 24 h of exposure to PHE. The survival rate of PHE had no effect at a maximum of $300mg\;L^{-1}$. The r was determined after 72 h of exposure to PHE. It was observed that r in the controls (absence PHE) was greater than 0.5, but that it suddenly decreased with an increased concentration of PHE. PHE reduced r in a dose-dependent manner and a significant reduction occurred at a concentration of greater than $37.5mg\;L^{-1}$. The $EC_{50}$ value of r in PHE exposure was $63.7mg\;L^{-1}$. The no-observed-effect-concentration (NOEC) of r in PHE exposure was $18.8mg\;L^{-1}$. The lowest-observed-effect-concentration (LOEC) of r in the PHE exposure was $37.5mg\;L^{-1}$. From the results, the concentration of PHE (greater than $37.5mg\;L^{-1}$) has a toxic effect on the r of B. plicatilis in natural ecosystems. These results(including NOEC, LOEC and $EC_{50}$) might be useful for the Polycyclic aromatic hydrocarbons(PAHs) toxicity assessment in marine ecosystems.

Toxic Assessment of BDE-47 and BDE-209 using the Population Growth Rates of Skeletonema costatum (해산규조류(Skeletonema costatum)의 개체군 성장률을 이용한 브롬화난연제(BDE-47, BDE-209) 독성평가)

  • Heo, Seung;Lee, Ju-Wook;Park, Yun-Ho;Park, Na-Young;Lee, In-Seok;Hwang, Un-Ki;Choi, Hoon
    • Korean Journal of Environmental Biology
    • /
    • v.36 no.3
    • /
    • pp.385-391
    • /
    • 2018
  • Toxic assessment of PBDEs (BDE-47, BDE-209) has carried out using the rates of population growth in marine phytoplankton, Skeletonema costatum. The population growth rate (r) in S. costatum was determined after 96 hours of exposure to BDE-47 (2,2'4,4'-Tetrabromodiphenyl ether) and BDE-209 (2,2', 4,4'-Decabromodiphenyl ether). It was observed that r-value in the controls (absence PBDEs) was greater than 0.04 and further a decrease was observed in a dose-dependent manner. BDE-47 reduced population growth rate in a dose-dependent manner and a significant reduction occurred at a concentration greater than $0.31mgL^{-1}$, but BDE-209 had no effect on population growth rate even at concentrations greater than $125mgL^{-1}$. The population growth rate in the presence of BDE-47 and BDE-209, $EC_{50}$ values were $0.55mgL^{-1}$ and >$125mgL^{-1}$, and NOEC values were $0.16mgL^{-1}$ and >$125mgL^{-1}$, respectively. Therefore, BDE-47 is considered to be about over 80 times more harmful than BDE-209. In this study, the ecotoxic assessment based on population growth rate in S. costatum can be used as a baseline data for establishment of environment standard quality of BDE-47 and BDE-209 in the marine environment.

Assessment of Dose Distribution using the MIRD Phantom at Uterine Cervix and Surrounding Organs in High Doserate Brachytheraphy (자궁주위 방사선 근접치료시 MIRD 팬텀을 이용한 주변장기의 피폭환경평가)

  • Lee, Yun-Jong;Nho, Young-Chang;Lee, Jai-Ki
    • Korean Journal of Environmental Biology
    • /
    • v.24 no.4
    • /
    • pp.387-391
    • /
    • 2006
  • Computational and experimental dosimetry of Henschke applicator with respect to high dose rate brachytherapy using the MIRD phantom and a remote control afterloader were performed. A comparison of computational dosimetry was made between the simulated Monte Carlo dosimetry and GAMMADOT brachytherapy Planning system's dosimetry. Dose measurements was performed using ion chamber in a water phantom. Dose rates are calculated using Monte Carlo code MCNP4B and the GAMMADOT. Thecomputational models include the detailed geometry of Ir-192 source, tandem tube, and shielded ovoids for accurate estimation. And transit dose delivered during source extension to and retraction from a given dwell position was estimated by Monte Carlo simulations. Point doses at ICRU bladder/rectal pointswhich have been recommened by ICRU 38 was assessed. Calculated and measured dose distribution data agreed within 4% each other. The shielding effect of ovoids leads to 19% and 20% dose reduction at bladder surface and rectal points.

Dose Assessment According to Application of Carbon Fabric Blanket During Radiation Therapy of the Spine Metastasis Cancer (척추 전이암 환자의 방사선치료 시 Carbon Fabric Blanket 적용에 따른 선량평가)

  • Yang, Myung-Sic;Kim, Jung-Soo;Lee, Sun-Young;Kwon, Hyoung-Cheol
    • Journal of radiological science and technology
    • /
    • v.42 no.1
    • /
    • pp.61-66
    • /
    • 2019
  • The purpose of this study was to improve the unstable treatment posture by placing the Carbon fabric blanket on the couch which was used for the patient fixation for the unstable posture from the severe pain caused by the neuromuscular pressure of the spinal metastatic cancer patient and to analyze the dose difference caused by the energy loss of high energy radiation. Using a linear accelerator, a FC-65G was installed at a depth of 5 cm at a solid phantom at 6 MV and 10 MV energies. The SAD was 100 cm, Gantry angle was $0^{\circ}$, a Cotton and Carbon blanket with a thickness of 1 cm on the couch, The blankets were placed on the couch and the dose was measured according to field size. For the dose measurement, and the dose was measured at 100 MU each time, and the mean value was calculated by repeating the measurement three times in order to reduce the error. The results showed that the difference rate in dose between Carbon blanket and Cotton blanket was respectively -0.54% and -0.75% based on the absence of the blanket(Non). Therefore, it is considered that the use of Carbon fabric blanket, which reduces the patient's pain and does not affect the depth dose, may be useful during radiation therapy of the spine metastasis cancer.

General Radiography Imaging Usage and Effective Dose of Inpatients: Based on Data from Inpatients in 2018 (입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터)

  • Jong-Won Gil
    • Journal of radiological science and technology
    • /
    • v.47 no.2
    • /
    • pp.107-116
    • /
    • 2024
  • In this study, we analyzed the use of general radiography imaging and effective dose in inpatients. Our aim is to help reduce national medical radiation exposure doses and develop rational health-care financial policies. The effective dose for each general radiography was calculated using the ALARA-GR program for 53 types (total: 260 codes) general radiography codes selected from 'National Health Insurance Care Benefit Cost'. The usage of general radiography was analyzed in the 2018 inpatient patient data of the Health Insurance Review and Assessment Service, and the effective dose for each general radiography was analyzed. 89.00% of inpatients undergo general radiography imaging at least once, with an average of 12.63 scans per person and an effective dose of 1.00 mSv. Those who received support from Medical Aid showed a higher value compared to those who were insured by National Health Insurance, with 17.39 cases and 1.43 mSv (p<.001). Chest had the highest usage rate at 23.12% for general radiography imaging, while L-spine had the highest effective dose at 24.53%. It is estimated that 420 inpatients patients undergo 121 to 820 general radiography imaging procedures per year, and 233 inpatients are estimated to have an annual effective dose of >20.00~58.25 mSv. Rational use of health-care finances and the practice of medical radiation safety management are essential for the well-being of individuals, the enhancement of quality of life, and the improvement of health-care quality.

A Model for Radiological Dose Assessment in an Urban Environment (도시환경에서 방사성물질 오염에 따른 선량평가모델)

  • Hwang, Won-Tae;Kim, Eun-Han;Jeong, Hyo-Joon;Suh, Kyung-Suk;Han, Moon-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.1
    • /
    • pp.1-8
    • /
    • 2007
  • A model for radiological dose assessment in an urban environment, METRO-K has been developed. Characteristics of the model are as follows ; 1) mathematical structures are simple (i.e. simplified input parameters) and easy to understand due to get the results by analytical methods using experimental and empirical data, 2) complex urban environment can easily be made up using only 5 types of basic surfaces, 3) various remediation measures can be applied to different surfaces by evaluating the exposure doses contributing from each contamination surface. Exposure doses contributing from each contamination surface at a particular location of a receptor were evaluated using the data library of kerma values as a function of gamma energy and contamination surface. A kerma data library was prepared fur 7 representative types of Korean urban buildings by extending those data given for 4 representative types of European urban buildings. Initial input data are daily radionuclide concentration in air and precipitation, and fraction of chemical type. Final outputs are absorbed dose rate in air contributing from the basic surfaces as a function of time following a radionuclide deposition, and exposure dose rate contributing from various surfaces constituting the urban environment at a particular location of a receptor. As the result of a contaminative scenario for an apartment built-up area, exposure dose rates show a distinct difference for surrounding environment as well as locations of a receptor.

Risk Assessment in OECD High Production Volume Chemicals Program and its Countermeasure (OECD 대량생산화학물질 위해성평가 및 대책)

  • Kim, Myungjin;Bae, Heekyung;Choi, Yeonki;Kim, Mi Kyoung;Koo, Hyun-Ju;Song, Sang-Hwan;Choi, Kwang-Soo
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.5
    • /
    • pp.347-353
    • /
    • 2005
  • The risk assessment is the qualitative or quantitative evaluation of the risk posed to human health and the environment by the actual or potential presence or release of hazardous substances, pollutants or contaminants. The environmental impact assessment (EIA) is assessed by the environmental criteria, and risk assessment is assessed by the risk rate. Risk rate based on dose-response values may not be easy to apply on regulatory basis like EIA for uncertainty. Internationally there is an example of OECD program. Risk assessment of High Production Volume (HPV) Chemicals has started since the OECD Program with the 1990 Council Act on the Co-operative Investigation and Risk Reduction of Existing Chemicals. These HPV chemicals include all chemicals produced or imported at levels greater than 1,000 tonnes per year in at least one Member country or in the European Union region. The SIDS called the Screening Information Data Set is regarded as the minimum information needed to assess an HPV chemical to determine whether any further work should be carried out or not. All the data elements of SIDS including assessment for environment and health are prepared as three formats of the full SIDS Dossier, the SIDS Initial Assessment Report (SIAR), and the SIDS Initial Assessment Profile (SIAP) of an HPV chemical. In 1998 the global chemical industry through the International Council of Chemical Associations (ICCA) has joined to work with OECD. The OECD has assessed approximately 1,000 chemicals from 1991 through 2004 with ICCA. Till the February of 2005, 592 chemicals of those chemicals completed SIDS reports. Member countries have been targeted the goal of 1,000 new chemicals from 2005 to 2010 and Korea shared 36 chemicals from the 1,000 new chemicals. Currently Korea has completed SIDS reports of 7 chemicals among sponsored 24 chemicals. In conclusion SIDS project will be linked to national program for outputs application with more reliable production. Both the OECD and industry will carry out their commitment to complete assessments for more and the remaining chemicals assessment. The major outputs will contribute to cope with international chemical management.