• Title/Summary/Keyword: Dose Rate

Search Result 3,201, Processing Time 0.042 seconds

The outcome of short-term low-dose aspirin treatment in Kawasaki disease based on inflammatory markers

  • Yoo, Jae Won;Kim, Ji Mok;Kil, Hong Ryang
    • Clinical and Experimental Pediatrics
    • /
    • v.60 no.1
    • /
    • pp.24-29
    • /
    • 2017
  • Purpose: Previously, Kawasaki disease (KD) treatment with low-dose aspirin was administered for 6-8 weeks after the acute phase. However, inflammatory marker levels normalize before 6-8 weeks. In this study, we aimed to investigate the clinical outcome of short-term low-dose aspirin treatment based on inflammatory and thrombotic marker levels. Methods: We performed a retrospective review of the medical records of patients with KD who were hospitalized at Chungnam National University Hospital between September 2012 and May 2014. When fever subsided, low-dose aspirin treatment was started. Inflammatory (white blood cell count, erythrocyte sedimentation rate, and C-reactive protein) and thrombotic markers (D-dimer) were monitored at follow-ups conducted in 1- to 2-week intervals. The low-dose aspirin administration was terminated when both markers were normalized and no cardiovascular complications were observed. Results: Eighty-four patients with KD (complete KD, n=49; incomplete KD, n=35) were enrolled. The inflammatory and thrombotic marker levels were normalized within 3-4 weeks on average. At the beginning the low-dose aspirin treatment, 9 patients had coronary artery lesions but 75 did not. When the low-dose aspirin administration was terminated at the time the inflammatory marker levels were normalized, no new CALs developed during the follow-up at 6-8 weeks. Conclusion: Most of the inflammatory marker levels were normalized within 3-4 weeks after the acute phase of KD. New cardiovascular complications did not develop during the course of the short-term aspirin treatment based on the inflammatory marker levels, clinical findings, and echocardiography.

The Result of Radiation Therapy of Superior Vena Cava Syndrome (상행정맥 증후군의 방사선 치료 성적)

  • Cho Chong Hee;Kim Hyun Soon;Hong Seong Eon;Ahn Chi Yul
    • Radiation Oncology Journal
    • /
    • v.4 no.1
    • /
    • pp.67-73
    • /
    • 1986
  • To access the result of radiation therapy for 8 years experiences, 21 patients who were treated with superior vena cava syndrome had been analysed according to dose fractionation and total dose. The results are as follows; 1. In high fractionate dose group, six of eleven patients $(54.5\%)$ exhibited relief of symptoms in 1-2 days, and additional three patients of nine $(81.7\%)$ within 34 days, while standard fractionated dose treatment is not effective to achieve initial relief of symptoms. 2. Graded response by total dose was correlated with total dose rather than dose fractionation. 3. Overall one year survival rate with superior vena cava syndrome was $9.1\%$ and mean survival was 4.2 months.

  • PDF

Assessment of the Glycophorin A Mutant Assay as a Biologic Marker for Low Dose Radiation Exposure (저선량 방사선 노출에 대한 생물학적 지표로서 Glycophorin A 변이발현율 측정의 유용성 평가)

  • Ha, Mi-Na;Yoo, Keun-Young;Ha, Sung-Whan;Kim, Dong-Hyun;Cho, Soo-Hun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.33 no.2
    • /
    • pp.165-173
    • /
    • 2000
  • Objectives : To assess the availability of the glycophorin A (GPA) assay to detect the biological effect of ionizing radiation in workers exposed to low-doses of radiation. Methods : Information on confounding factors, such as age and cigarette smoking was obtained on 144 nuclear power plant workers and 32 hospital workers, by a self-administered questionnaire. Information on physical exposure levels was obtained from the registries of radiation exposure monitoring and control at each facility. The GPA mutant assay was performed using the BR6 method with modification by using a FACScan flow cytometer. Results : As confounders, age and cigarette smoking habits showed increasing trends with GPA variants, but these were of no statistical significance. Hospital workers showed a higher frequency of the GPA variant than nuclear power plant workers in terms of the NO variant. Significant dose-response relationships were obtained from in simple and multiple linear regression models. The slope of the regression equation for nuclear power plant workers was much smaller than that of hospital workers. These findings suggest that there may be apparent dose-rate effects. Conclusion : In population exposed to chronic low-dose radiation, the GPA assay has a potential to be used as an effective biologic marker for assessing the bone marrow cumulative exposure dose.

  • PDF

Dynamically Collimated CT Scan and Image Reconstruction of Convex Region-of-Interest (동적 시준을 이용한 CT 촬영과 볼록한 관심영역의 영상재구성)

  • Jin, Seung Oh;Kwon, Oh-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.151-159
    • /
    • 2014
  • Computed tomography (CT) is one of the most widely used medical imaging modality. However, substantial x-ray dose exposed to the human subject during the CT scan is a great concern. Region-of-interest (ROI) CT is considered to be a possible solution for its potential to reduce the x-ray dose to the human subject. In most of ROI-CT scans, the ROI is set to a circular shape whose diameter is often considerably smaller than the full field-of-view (FOV). However, an arbitrarily shaped ROI is very desirable to reduce the x-ray dose more than the circularly shaped ROI can do. We propose a new method to make a non-circular convex-shaped ROI along with the image reconstruction method. To make a ROI with an arbitrary convex shape, dynamic collimations are necessary to minimize the x-ray dose at each angle of view. In addition to the dynamic collimation, we get the ROI projection data with slightly lower sampling rate in the view direction to further reduce the x-ray dose. We reconstruct images from the ROI projection data in the compressed sensing (CS) framework assisted by the exterior projection data acquired from the pilot scan to set the ROI. To validate the proposed method, we used the experimental micro-CT projection data after truncating them to simulate the dynamic collimation. The reconstructed ROI images showed little errors as compared to the images reconstructed from the full-FOV scan data as well as little artifacts inside the ROI. We expect the proposed method can significantly reduce the x-ray dose in CT scans if the dynamic collimation is realized in real CT machines.

Preoperative chemoradiation for locally advanced rectal cancer: comparison of three radiation dose and fractionation schedules

  • Park, Shin-Hyung;Kim, Jae-Chul
    • Radiation Oncology Journal
    • /
    • v.34 no.2
    • /
    • pp.96-105
    • /
    • 2016
  • Purpose: The standard radiation dose for patients with locally rectal cancer treated with preoperative chemoradiotherapy is 45-50 Gy in 25-28 fractions. We aimed to assess whether a difference exists within this dose fractionation range. Materials and Methods: A retrospective analysis was performed to compare three dose fractionation schedules. Patients received 50 Gy in 25 fractions (group A), 50.4 Gy in 28 fractions (group B), or 45 Gy in 25 fractions (group C) to the whole pelvis, as well as concurrent 5-fluorouracil. Radical resection was scheduled for 8 weeks after concurrent chemoradiotherapy. Results: Between September 2010 and August 2013, 175 patients were treated with preoperative chemoradiotherapy at our institution. Among those patients, 154 were eligible for analysis (55, 50, and 49 patients in groups A, B, and C, respectively). After the median follow-up period of 29 months (range, 5 to 48 months), no differences were found between the 3 groups regarding pathologic complete remission rate, tumor regression grade, treatment-related toxicity, 2-year locoregional recurrence-free survival, distant metastasis-free survival, disease-free survival, or overall survival. The circumferential resection margin width was a prognostic factor for 2-year locoregional recurrence-free survival, whereas ypN category was associated with distant metastasis-free survival, disease-free survival, and overall survival. High tumor regression grading score was correlated with 2-year distant metastasis-free survival and disease-free survival in univariate analysis. Conclusion: Three different radiation dose fractionation schedules, within the dose range recommended by the National Comprehensive Cancer Network, had no impact on pathologic tumor regression and early clinical outcome for locally advanced rectal cancer.

A Comparison between Three Dimensional Radiation Therapy and Intensity Modulated Radiation Therapy on Prostate Cancer (전립샘암의 방사선 치료 시 입체조형치료법와 세기조절방사선 치료법의 비교)

  • Kim, YoungJae;Lee, JaeSub;Hong, Seongill;Ko, HyeJin
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.409-414
    • /
    • 2013
  • In this study, we evaluated to the superiority of treatment techniques on prostate cancer, apply to each other treatment techniques-3D conformal therapy versus IMRT-using dose distribution and dose coverages. Obtained 10 patients CT simulation, divided tumor volume and critical organs. Prescription dose was 80 Gy on tumor volume and Each of plans was set by two different plans. As a result, Dose coverage was superior to IMRT. The IMRT's tumor absorbed dose(100.2%) was close to prescription doses. Normal tissue(bladder, rectal, bowel Lt Rt fumoral head) absorbed dose rate was superior. In other words, the radiation therapy of prostate cancer with intensity modulated radiation therapy was better than conformal radiation therapy on dose.

Graves' Disease Patients with Large Goiters Respond Best to Radioactive Iodine Doses of at Least 15 mCi: a Sonographic Volumetric Study

  • Jeong, Yun Ah;Yoon, Jee Hee;Kim, Hee Kyung;Kang, Ho-Cheol
    • International journal of thyroidology
    • /
    • v.11 no.2
    • /
    • pp.137-142
    • /
    • 2018
  • Background and Objectives: Radioactive iodine therapy (RAI) is an important treatment modality of Graves' disease (GD), but there is still not a consensus on the optimal dosage regimen. We studied the treatment success rate of different RAI doses, and examined which clinical markers were useful for determining the optimal RAI dosage for successful therapy in Korean patients. Materials and Methods: We retrospectively studied 123 patients with GD treated with RAI between 2004 and 2014 at Chonnam National University Hwasun Hospital. The responder group was defined as patients who developed hypothyroidism requiring levothyroxine replacement following RAI, regardless of the RAI dosage. Results: A total of 54 patients (43.9%) became hypothyroid after the first dose, and 31 needed two to four additional doses to achieve hypothyroidism. In the responder group as a whole (85 patients), the mean total dose of RAI was $15.5{\pm}7.0mCi$ and the mean thyroid volume (TV) was $35.4{\pm}23.4mL$. When divided into low dose (<15 mCi, n=46) and high dose (${\geq}15mCi$, n=39) responder groups, TV was significantly lower in the low-dose responder group ($25.7{\pm}11.4$ vs. $48.4{\pm}31.3$, p<0.001). The optimal cut-off TV for the low-dose responder group was <32.37 mL (sensitivity 80.9%, specificity 76.7%). Conclusion: TV had significant effects on the outcome of RAI in GD patients. The optimal fixed RAI dose for Korean GD patients with a large goiter (${\geq}33mL$) should be at least 15 mCi to achieve the best outcome.

Characteristics of Internal and External Exposure of Radon and Thoron in Process Handling Monazite (모나자이트 취급공정에서의 라돈 및 토론 노출 특성)

  • Chung, Eun Kyo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.2
    • /
    • pp.167-175
    • /
    • 2019
  • Objectives: The purpose of this study was to evaluate airborne radon and thoron levels and estimate the effective doses of workers who made household goods and mattresses using monazite. Methods: Airborne radon and thoron concentrations were measured using continuous monitors (Rad7, Durridge Company Inc., USA). Radon and thoron concentrations in the air were converted to radon doses using the dose conversion factor recommended by the Nuclear Safety and Security Commission in Korea. External exposure to gamma rays was measured at the chest height of a worker from the source using real-time radiation instruments, a survey meter (RadiagemTM 2000, Canberra Industries, Inc., USA), and an ion chamber (OD-01 Hx, STEP Co., Germany). Results: When using monazite, the average concentration range of radon was $13.1-97.8Bq/m^3$ and thoron was $210.1-841.4Bq/m^3$. When monazite was not used, the average concentration range of radon was $2.6-10.8Bq/m^3$ and the maximum was $1.7-66.2Bq/m^3$. Since monazite has a higher content of thorium than uranium, the effects of thoron should be considered. The effective doses of radon and thoron as calculated by the dose conversion factor based on ICRP 115 were 0.26 mSv/yr and 0.76 mSv/yr, respectively, at their maximum values. The external radiation dose rate was $6.7{\mu}Sv/hr$ at chest height and the effective dose was 4.3 mSv/yr at the maximum. Conclusions: Regardless of the use of monazite, the total annual effective doses due to internal and external exposure were 0.03-4.42 mSv/yr. Exposures to levels higher than this value are indicated if dose conversion factors based on the recently published ICRP 137 are applied.

A Study on Retrospective of External Radiation Exposure Dose by Optically Stimulated Luminescence of Smart Chip Card (스마트칩 카드을 이용한 광 자극 발광 특성 연구)

  • Park, Sang-Won;Yoo, Se-Jong
    • Journal of radiological science and technology
    • /
    • v.42 no.5
    • /
    • pp.379-385
    • /
    • 2019
  • Radiation is used for various purposes such as cancer therapy, research of industrial and drugs. However, in case of radiation accidents such as terrorism, collapsing nuclear plant by natural disasters like Fukushima in 2011, very high radiation does expose to human and could lead to death. For this reason, many people are concerning about radiation exposures. Therefore, assessment and research of retrospective radiation dose to human by various path is an necessary task to be continuously developed. Radiation exposure for workers in radiation fields can be generally measured using a personal exposure dosimeter such as TLD, OSLD. However, general people can't be measured radiation doses when they are exposed to radiation. And even if radiation fields workers, when they do not in possession personal dosimeter, they also can't be measured exposure dose immediately. In this study, we conduct retrospective research on reconstruction of dose after exposure by using smart chip card of personal items through Optically Stimulated Luminescence (OSL). The OSL signal of smart chip card shows linear response from 0.06 Gy to 15 Gy and results of fading rate 45 %, 48% for 24 and 48 hours due to the natural emission of radiation in sample, respectively. The minimum detectable limit (MDD) was 0.38 mGy. This values are expected to use as correction values for reconstruction of exposure dose.

A Study on Predictive Modeling of I-131 Radioactivity Based on Machine Learning (머신러닝 기반 고용량 I-131의 용량 예측 모델에 관한 연구)

  • Yeon-Wook You;Chung-Wun Lee;Jung-Soo Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.131-139
    • /
    • 2023
  • High-dose I-131 used for the treatment of thyroid cancer causes localized exposure among radiology technologists handling it. There is a delay between the calibration date and when the dose of I-131 is administered to a patient. Therefore, it is necessary to directly measure the radioactivity of the administered dose using a dose calibrator. In this study, we attempted to apply machine learning modeling to measured external dose rates from shielded I-131 in order to predict their radioactivity. External dose rates were measured at 1 m, 0.3 m, and 0.1 m distances from a shielded container with the I-131, with a total of 868 sets of measurements taken. For the modeling process, we utilized the hold-out method to partition the data with a 7:3 ratio (609 for the training set:259 for the test set). For the machine learning algorithms, we chose linear regression, decision tree, random forest and XGBoost. To evaluate the models, we calculated root mean square error (RMSE), mean square error (MSE), and mean absolute error (MAE) to evaluate accuracy and R2 to evaluate explanatory power. Evaluation results are as follows. Linear regression (RMSE 268.15, MSE 71901.87, MAE 231.68, R2 0.92), decision tree (RMSE 108.89, MSE 11856.92, MAE 19.24, R2 0.99), random forest (RMSE 8.89, MSE 79.10, MAE 6.55, R2 0.99), XGBoost (RMSE 10.21, MSE 104.22, MAE 7.68, R2 0.99). The random forest model achieved the highest predictive ability. Improving the model's performance in the future is expected to contribute to lowering exposure among radiology technologists.