• Title/Summary/Keyword: Dose Evaluation

Search Result 1,873, Processing Time 0.031 seconds

RADIATION SHIELDING EVALUATION OF IP-2 PACKAGES FOR LOW- AND INTERMEDIATE-LEVEL RADIOACTIVE WASTE

  • Kim, Min-Chul;Choi, Jong-Rak;Chung, Sung-Hwan;Ko, Jae-Hoon
    • Nuclear Engineering and Technology
    • /
    • v.40 no.6
    • /
    • pp.511-516
    • /
    • 2008
  • Korea Hydro & Nuclear Power Co., Ltd. (KHNP) developed new IP-2 packages to transport low- and intermediate-level radioactive waste (LILW) steel drums from nuclear power plants to a disposal facility in accordance with IAEA and Korean transport regulations of radioactive material. Radiation shielding evaluation of the packages was carried out to demonstrate compliance with the regulatory requirements for IP-2 packages of radioactive material. Dose rate limits of LILW drums contained in the packages were determined.

Evaluation of absorbed dose in monkey and mouse using 18F-FDG PET and CT density information

  • Kim, Wook;Lee, Yong Jin;Park, Yong Sung;Cho, Doo-Wan;Lee, Hong-Soo;Han, Su-Cheol;Kang, Joo Hyun;Woo, Sang-Keun
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.1
    • /
    • pp.18-24
    • /
    • 2017
  • Patient-specific image-based internal dosimetry involves using the patient's individual anatomy and spatial distribution of radioactivity over time to obtain an absorbed dose calculation. Individual absorbed dose was calculated by accumulated activity multiply S-value of each organs. The aim of this study was to calculate the S-values using Monte Carlo simulation in monkey and mouse and evaluation of absorbed dose in each organ. Self-irradiation S-value of monkey heart self-irradiation was 3.15E-03 mGy-g/MBq-s, lung self-irradiation was 8.94E-04 mGy-g/MBq-s and liver self-irradiation S-value was 2.23E-03 mGy-g/MBq-s. Mouse heart self-irradiation S-value was 1.95E-01 mGy-g/MBq-s, lung was 9.59E-02 mGy-g/MBq-s, and liver was 1.40E-03 mGy-g/MBq-s. The results of this study show that the calculation protocol of image based individual absorbed dose of each organ using Monte Carlo simulation. Therefore, this study may be applied to calculate human specific absorbed dose.

Evaluation of Relative Fluoride Toxicity and Its Impact on Growth, Economic Characters and Fecundity of the Silkworm, Bombyx mori L.

  • Ramakrishna, S.;Nath, B.Surendra;Jayaprakash
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.8 no.2
    • /
    • pp.151-159
    • /
    • 2004
  • A detailed evaluation of relative toxicity of fluoride to die 5th instar larvae of PM and NB$_4$D$_2$ races of silkworm and the effects of lethal, sublethal and prevailing levels of fluoride in groundwater on the growth, economic characters and fecundity of the silkworm, Bombyx mori (Lepidoptera: Bombycidae) were studied. The feeding of mulberry, Morus alba leaves treated with lethal and sublethal doses of fluoride to PM and NB$_4$D$_2$ races of silkworms from the beginning of the 5th instar to the end of the feeding period resulted in significant reduction in growth, single cocoon weight, single shell weight, silk index, average filament length, and fecundity when compared to controls. These manges were more pronounced on exposure to lethal dose than sublethal dose and in general, the changes induced by fluoride were more striking in NB$_4$D$_2$ than PM, indicating the greater resistance of PM to higher fluoride levels. Groundwater quality in sericulturally important villages of Karnataka and Andhra Pradesh States has been studied with special reference to the presence of fluoride. On exposure to dose of prevailing levels in the waters of sericulturally important areas, die changes observed on growth, economic characters and fecundity were slightly lower when compared to controls and the decrease was found to be insignificant (P$\geq$0.05). It was concluded that, though minute dose (4.0 ppm) of fluoride did not have any toxic impact, it is toxic at higher concentrations to silkworms.

Optimization of Brain Computed Tomography Protocols to Radiation Dose Reduction (뇌전산화단층검사에서 방사선량 저감을 위한 최적화 프로토콜 연구)

  • Lee, Jae-Seung;Kweon, Dae Cheol
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.3
    • /
    • pp.116-123
    • /
    • 2018
  • This study is a model experimental study using a phantom to propose an optimized brain CT scan protocol that can reduce the radiation dose of a patient and remain quality of image. We investigate the CT scan parameters of brain CT in clinical medical institutions and to measure the important parameters that determine the quality of CT images. We used 52 multislice spiral CT (SOMATOM Definition AS+, Siemens Healthcare, Germany). The scan parameters were tube voltage (kVp), tube current (mAs), scan time, slice thickness, pitch, and scan field of view (SFOV) directly related to the patient's exposure dose. The CT dose indicators were CTDIvol and DLP. The CT images were obtained while increasing the imaging conditions constantly from the phantom limit value (Q1) to the maximum value (Q4) for AAPM CT performance evaluation. And statistics analyzed with Pearson's correlation coefficients. The result of tube voltage that the increase in tube voltage proportionally increases the variation range of the CT number. And similar results were obtained in the qualitative evaluation of the CT image compared to the tube voltage of 120 kVp, which was applied clinically at 100 kVp. Also, the scan conditions were appropriate in the tube current range of 250 mAs to 350 mAs when the tube voltage was 100 kVp. Therefore, by applying the proposed brain CT scanning parameters can be reduced the radiation dose of the patient while maintaining quality of image.

The Evaluation of Eye Dose and Image Quality According to The New Tube Current Modulation and Shielding Techniques in Brain CT (두부 CT에서 차폐기법과 새로운 관전류변조기법에 따른 눈의 선량과 화질평가)

  • Kwon, Soonmu;Kim, Jungsu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.279-285
    • /
    • 2015
  • The eye of human is a radiation sensitive organ and this organ should be shielded from radiation exposure during brain CT procedures. In the brain CT procedures, bismuth protector using to reduce the radiation exposure dose for eye. But protecting the bismuth always accompanies problem of the image quality reduction including artifact. This study aim is the eye radiation exposure dose and image quality evaluation of the new tube current modulation such as new organ based-tube current modulation, longitudinal-TCM, angular-TCM between shielding scan technique using bismuth and lead glasses. As a result, radiation dose of eye is reduced 25.88% in new OB TCM technique then reference scan technique and SNR new OB TCM is 6.05 higher than bismuth shielding scan technique and lower than reference scan technique. In clinical brain CT, new OB TCM technique will contribute to reduction of radiation dose for eye without decrease of image quality.

Low-dose CT Image Denoising Using Classification Densely Connected Residual Network

  • Ming, Jun;Yi, Benshun;Zhang, Yungang;Li, Huixin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.6
    • /
    • pp.2480-2496
    • /
    • 2020
  • Considering that high-dose X-ray radiation during CT scans may bring potential risks to patients, in the medical imaging industry there has been increasing emphasis on low-dose CT. Due to complex statistical characteristics of noise found in low-dose CT images, many traditional methods are difficult to preserve structural details effectively while suppressing noise and artifacts. Inspired by the deep learning techniques, we propose a densely connected residual network (DCRN) for low-dose CT image noise cancelation, which combines the ideas of dense connection with residual learning. On one hand, dense connection maximizes information flow between layers in the network, which is beneficial to maintain structural details when denoising images. On the other hand, residual learning paired with batch normalization would allow for decreased training speed and better noise reduction performance in images. The experiments are performed on the 100 CT images selected from a public medical dataset-TCIA(The Cancer Imaging Archive). Compared with the other three competitive denoising algorithms, both subjective visual effect and objective evaluation indexes which include PSNR, RMSE, MAE and SSIM show that the proposed network can improve LDCT images quality more effectively while maintaining a low computational cost. In the objective evaluation indexes, the highest PSNR 33.67, RMSE 5.659, MAE 1.965 and SSIM 0.9434 are achieved by the proposed method. Especially for RMSE, compare with the best performing algorithm in the comparison algorithms, the proposed network increases it by 7 percentage points.

Development Treatment Planning System Based on Monte-Carlo Simulation for Boron Neutron Capture Therapy

  • Kim, Moo-Sub;Kubo, Kazuki;Monzen, Hajime;Yoon, Do-Kun;Shin, Han-Back;Kim, Sunmi;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.232-235
    • /
    • 2016
  • The purpose of this study is to develop the treatment planning system (TPS) based on Monte-Carlo simulation for BNCT. In this paper, we will propose a method for dose estimation by Monte-Carlo simulation using the CT image, and will evaluate the accuracy of dose estimation of this TPS. The complicated geometry like a human body allows defining using the lattice function in MCNPX. The results of simulation such as flux or energy deposition averaged over a cell, can be obtained using the features of the tally provided by MCNPX. To assess the dose distribution and therapeutic effect, dose distribution was displayed on the CT image, and dose volume histogram (DVH) was employed in our developed system. The therapeutic effect can be efficiently evaluated by these evaluation tool. Our developed TPS could be effectively performed creating the voxel model from CT image, the estimation of each dose component, and evaluation of the BNCT plan.

Assessment of Dose and Image Quality according to the Change of Distance from Source to Image Receptor and the Examination Posture during the Skull Lateral Radiography (두부 측 방향 방사선검사 시 선원 영상수용체간 거리와 검사 자세 변화가 선량과 영상품질에 미치는 영향)

  • Eun-Hye, Kim;Young-Cheol, Joo;Han-Yong, Kim;Dong-Hwan, Kim
    • Journal of radiological science and technology
    • /
    • v.45 no.6
    • /
    • pp.483-489
    • /
    • 2022
  • This study proposes a new skull lateral examination, and provides an improved examination environment for patients and radiologists. The study was divided into three groups. One group was divided into the SID (source to image receptor distance) 110 ㎝ and 180 ㎝ in the skull lateral posture, the other group The other group was divided into an position in contact with the detector and an position without contact with the detector, and the other group was divided into male and female groups, considering that the difference in shoulder width between adult males and females would affect the dose and image quality. For dose evaluation, the ESD (entrance surface dose) was measured at the EAM (external auditory meatus), and the conditions were applied equally at 70 ㎸p, 200 ㎃, and 10 ㎃s. For image quality evaluation, SNR (signal to noise ratio) and CNR (contrast to noise ratio) were measured in frontal sinus, EAM, and sella turcica. As a result of ESD comparison, when sid 110 ㎝ to sid 180 ㎝ was changed among the three groups, ESD values decreased the most to 729.18±4.62 μ㏉ and 224.18±0.74 μ㏉ at 180 ㎝ (p<0.01). The values of SNR and CNR were statistically significant (p<0.01), but there was no qualitative difference. This shows that when the SID is 180 ㎝, it is possible to reduce the dose without lowering the image quality. So, It is suggested that the SID 180 ㎝ is used without contacting the detector when examining the skull lateral.

Large-scale purification and single-dose oral-toxicity study of human thioredoxin and epidermal growth factor introduced into two different genetically modified soybean varieties

  • Jung-Ho, Park
    • Korean Journal of Agricultural Science
    • /
    • v.48 no.4
    • /
    • pp.1003-1013
    • /
    • 2021
  • Thioredoxin (TRX) protein is an antioxidant responsible for reducing other proteins by exchanging cysteine thiol-disulfide and is also known for its anti-allergic and anti-aging properties. On the other hand, epidermal growth factor (EGF) is an important material used in the cosmetics industry and an essential protein necessary for dermal wound healing facilitated by the proliferation and migration of keratinocytes. EGF also assists in the formation of granulation tissues and stimulates the motility of fibroblasts. Hence, genetically modified soybeans were developed to overexpress these industrially important proteins for mass production. A single-dose oral-toxicity-based study was conducted to evaluate the potential toxic effects of TRX and EGF proteins, as safety assessments are necessary for the commercial use of seed-specific protein-expressing transgenic soybeans. To achieve this rationale, TRX and EGF proteins were mass purified from recombinant E. coli. The single-dose oral-toxicity tests of the TRX and EGF proteins were carried out in six-week old male and female Institute of Cancer Research (ICR) mice. The initial evaluation of the single-dose TRF and EGF treatments was based on monitoring the toxicity signatures and mortality rates among the mice, and the resultant mortality rates did not show any specific clinical symptoms related to the proteins. Furthermore, no significant differences were observed in the weights between the treatment and control groups of male and female ICR mice. After 14 days of treatment, no differences were observed in the autopsy reports between the various treatment and control groups. These results suggest that the minimum lethal dose of TRX and EGF proteins is higher than the allowed 2,000 mg·kg-1 limit.

The Verification of Dosimetric Characteristics of the 3-D Compensator with the Exit Beam Dose Profile (Exit Beam Dose Profile을 이용한 3차원 보상체의 성능확인)

  • 이상훈;이병용;권수일;김종훈;장혜숙
    • Progress in Medical Physics
    • /
    • v.7 no.2
    • /
    • pp.3-17
    • /
    • 1996
  • Dose compensators have been widely used in radiotherapy fields. But, few reliable verification methods have been reported. We have developed the verification method for the evaluation of the effect of dose compensator using exit beam dose profile. The exit beam dose profiles were measured with and without dose compensator. For this purpose X-Omat V films and lead screened cassettes are used and dose distibutions are compared. Phantom data are collected using CT simulator(Picker, AcQ Sim) and compensator information can be obtained from Render Plan 3-D planning System. Aluminum Compensators are generated by computer controlled milling machine. The real dose distribution in the phantom and the exit beam dose profile can be obtained simultaneously with the films in the phantom and the opposite site of the beam. Dose compensations effects for oblique beam, parallel opposing beam and inhomogeneous human phantom can be obtained using above tools. And we could simate those effects with exit beam dose profile using the method that we have developed in this study.

  • PDF