• Title/Summary/Keyword: Dose Estimation

Search Result 260, Processing Time 0.039 seconds

Measurement and Estimation for the Clearance of Radioactive Waste with Patients of Thyroid Treatment (갑상선 진료환자 관련 방사성폐기물의 처분을 위한 방사능 측정 및 평가)

  • Kim, Chang-Bum;Jang, Seong-Joo
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.6
    • /
    • pp.255-261
    • /
    • 2014
  • The generation amount of radioactive waste has been rapidly increased by increase of the usage of radioisotope source in medical field. Especially, the use of the radioactive source of I-131 with short half-life of 8.02 days used in treatment of thyroid has been increased, and all of the wastes concerned have been disposed by means of the self-disposal method. IAEA proposed criteria for clearance level of waste which depends on the individual (10 ${\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). In this study, various radioactive wastes in medical fields are collected and measured for establishing the disposal methods and procedures of radioactive wastes. In addition, comparison evaluation of decay storage period between the half-life which was calculated by attenuation curve based on real measurement and analytical half-life is considered. With comparing the theoretical half-life and the effective half life(7.72 days) which was based on the decay equation of measured data, it is resulted in the theoretical half-life is longer than effective half-life. The storage period of radioactive waste for self-disposal may be curtailed. The result of this study will be proposed as ISO standard.

Application of coagulation pretreatment for enhancing the performance of ceramic membrane filtration (세라믹 막여과의 성능향상을 위한 응집 전처리의 적용)

  • Kang, Joon-Seok;Song, Jiyoung;Park, Seogyeong;Jeong, Ahyoung;Lee, Jeong-Jun;Seo, Inseok;Chae, Seonha;Kim, Seongsu;Kim, Han-Seung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.501-510
    • /
    • 2017
  • In this study, it is estimated that ceramic membrane process which can operate stably in harsh conditions replacing existing organic membrane connected with coagulation, sedimentation etc.. Jar-test was conducted by using artificial raw water containing kaolin and humic acid. It was observed that coagulant (A-PAC, 10.6%) 4mg/l is the optimal dose. As a results of evaluation of membrane single filtration process (A), coagulation-membrane filtration process (B) and coagulation-sedimentation-membrane filtration process (C), TMP variation is stable regardless of in Flux $2m^3/m^2{\cdot}day$. But in Flux $5m^3/m^2{\cdot}day$, it show change of 1-89.3 kpa by process. TMP of process (B) and (C) is increased 11.8, 0.6 kpa each. But, the (A) showed the greatest change of TMP. When evaluate (A) and (C) in Flux $10m^3/m^2{\cdot}day$, TMP of (A) stopped operation being exceeded 120 kpa in 20 minutes. On the other hand, TMP of (C) is increased only 3 kpa in 120 minutes. Through this, membrane filtration process can be operated stably by using the linkage between the pretreatment process and the ceramic membrane filtration process. Turbidity of treated water remained under 0.1 NTU regardless of flux condition and DOC and $UV_{254}$ showed a removal rate of 65-85%, 95% more each at process connected with pretreatment. Physical cleaning was carried out using water and air of 500kpa to show the recovery of pollutants formed on membrane surface by filtration. In (A) process, TMP has increased rapidly and decreased the recovery by physical cleaning as the flux rises. This means that contamination on membrane surface is irreversible fouling difficult to recover by using physical cleaning. Process (B) and (C) are observed high recovery rate of 60% more in high flux and especially recovery rate of process (B) is the highest at 95.8%. This can be judged that the coagulation flocs in the raw water formed cake layer with irreversible fouling and are favorable to physical cleaning. As a result of estimation, observe that ceramic membrane filtration connected with pretreatment improves efficiency of filtration and recovery rate of physical cleaning. And ceramic membrane which is possible to operate in the higher flux than organic membrane can be reduce the area of water purification facilities and secure a stable quantity of water by connecting the ceramic membrane with pretreatment process.

Measurement and Estimation for the Clearance of Radioactive Waste Contaminated with Radioisotopes for Medical Application (의료용 방사성폐기물 자체처분을 위한 방사능 측정 및 평가)

  • Kim, Changbum;Park, MinSeok;Kim, Gi-Sub;Jung, Haijo;Jang, Seongjoo
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.8-14
    • /
    • 2014
  • The amounts of radioactive wastes to be disposed in the medical institute have been increased due to development of radiation diagnosis and therapy rapidly. They are produced mostly by the very short lived radioisotopes such as $^{18}F$ used in PET/CT, $^{99m}Tc$, $^{123}I$, $^{125}I$ and $^{201}Tl$, etc. IAEA proposed a criteria for the clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). Radioactive wastes of $^{18}F$, $^{99m}Tc$, $^{123}I$, $^{125}I$ and $^{201}TI$ in the several types of container like Marinelli beaker, vial and plastic, were collected to measure the concentration of the waste of each nuclide in accordance with IAEA criteria. The measurement method and procedure of determining specific activity of the wastes using gamma emitters like MCA, gamma counter and beta emitters were developed. For the efficiency calibration of the detectors, CRM (certified reference material) which has the same dimension and shape was provided by Korea Research Institute of Standards and Science (KRISS). Correction factor of the radioactivity decay was calculated based on the measurement results, and the consideration of mutual relation with theoretical equation. The result of this study will be proposed as ISO standard.

A Study on Soil Slope Stability Design Considering Seepage Analysis (침투해석을 고려한 비탈면 설계에 대한 연구)

  • Kim, You-Seong;Kim, Jae-Hong;Lee, Jin-Kwang;Kim, Seong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.1
    • /
    • pp.135-147
    • /
    • 2013
  • Most of slope failures are triggered by heavy rainfall during rainy season. If the rain keeps on for the season, the water content of the ground increases and its matric suction decrease, and then the safety factor of soil slope gets lower. The change of water table level for soil slope stability dose not describe the behavior of the soil slope in real situation, hence it may be necessary to modify the design standard for slope stability in association with rain infiltration. For correct design, economical construction, and maintenance of a soil slope, unsaturated flow analysis is needed for estimation of slope instability regarding water infiltration and soil behavior on unsaturated soil slopes. The entire soil slope cannot be saturated by prolonged rainfall and wetting band depth (saturated zone) just deepens from slope surface, hence the cause of the shallow surface slide is the wetting band depth depending on rainfall duration and intensity. Therefore, the paper presents the differences between theoretical equation and numerical analysis for wetting band depth on soil surface and its safety factor, and compares the slope stability obtained from unsaturated flow analysis with that obtained from conventional slope stability analysis.

Evaluation of Residual Radiation and Radioactivity Level of TRIGA Mark-II, III Research Reactor Facilities for Safe Decommissioning (TRIGA Mark-II, III 연구로 시절의 폐로를 위한 시설의 잔류 방사선/능 평가)

  • Lee, B.J.;Chang, S.Y.;Park, S.K.;Jung, W.S.;Jung, K.J.
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.2
    • /
    • pp.109-120
    • /
    • 1999
  • Residual radiation and radioactivity level in TRIGA Mark-II, III research reactors and facilities at the KAERI Seoul site, which are to be decommissioned, have been measured, analyzed and evaluated to know the current status of radiation and radioactivity level and to establish and to provide the technical requirements for the safe decommissioning of the facilities which shall be applied in minimizing the radiation exposure for workers and in preventing the release of the radioactive materials to the environment. Radiation dose rate and surface radioactivity contamination level on the experimental equipments, floors, walls of the facilities, and the surface of the activated materials within the reactor pool structure were measured and evaluated. Radioactivity and radionuclides in the pool and cooling water were also analyzed. In case of the activated reactor pool structures which are very difficult to measure the radiation and radioactivity level, a computer code Fispin was additionally used for estimation of the residual radioactivity and radionuclides. The radiation and radioactivity data obtained in this study were effectively used as basic data for decontamination and dismantling plan for safe decommissioning of TRIGA Mark-II, III facilities.

  • PDF

Risk of Breast Cancer and Total Malignancies in Rheumatoid Arthritis Patients Undergoing TNF-α Antagonist Therapy: a Meta-analysis of Randomized Control Trials

  • Liu, Yang;Fan, Wei;Chen, Hao;Yu, Ming-Xia
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.8
    • /
    • pp.3403-3410
    • /
    • 2014
  • Context: Interest exits in whether TNF-alpha antagonists increase the risk of breast cancer and total malignancies in patients with rheumatoid arthritis (RA). Objectives: To analyze the risk of malignancies, especially breast cancer, in patients with RA enrolled in randomized control trials (RCTs). Methods: A systematic literature search for RCTs from 1 January 1998 to 1 July 2013 from online databases, such as PubMed, WILEY, EMBASE, ISI web of knowledge and Cochrane Library was conducted. Studies included RCTs that compared the safety of at least one dose of the five TNF-${\alpha}$ antagonists with placebo or methotrexate (MTX) (or TNF-${\alpha}$ antagonists plus MTX vs placebo plus MTX) in RA patients for more than 24 weeks and imported all the references into document management software EndNote${\times}6$. Two independent reviewers selected studies and extracted the data about study design, patients' characteristics and the type, number of all malignancies. Results: 28 RCTs from 34 records with 11,741 patients were analyzed. Of the total, 97 developed at least one malignancy during the double-blind trials, and breast cancer was observed in 17 patients (17.5% of total malignancies). However, there was no statistically significant increased risk observed in either the per protocol (PP) model (OR 0.65, 95%CI [0.22, 1.93]) or the modified intention to treat (mITT) model (OR 0.75, 95%CI [0.25, 2.21]). There were also no significant trend for increased risk of total malignancies on anti-TNF-${\alpha}$ therapy administered at approved doses in either model (OR, 1.06, 95%CI [0.64, 1.75], and OR, 1.30, 95%CI [0.80, 2.14], respectively). As to the two models, modified intention to treat model analysis led to higher estimation than per protocol model analysis. Conclusions: This study did not find a significantly increased risk of breast cancer and total malignancies in adults RA patients treated with TNF-${\alpha}$ antagonists at approved doses. However, it cannot be ignored that more patients developed malignancies with TNF-${\alpha}$ antagonists therapy compared with patients with placebo or MTX, in spite of the lack of statistical significance, so that more strict clinical trials and long-term follow-up are needed, and both mITT and PP analyses should be used in such safety analyses.

Determination of Quality Factors for Cylindrical Ionization Chambers in kV X-rays: Review of IAEA Dosimetry Protocol and Monte Carlo Calculations and Measurements for N23333 and N30001 Chambers (kV X-선에서 원통형전리함의 선질인자 결정에 관한 연구: IAEA 프로토클 고찰과 N23333, N30001 전리함에 대한 몬테칼로 계산 및 측정)

  • Lee Kang Kyoo;Lim Chunil;Chang Sei Kyung;Moon Sun Rock;Jeong Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.53-61
    • /
    • 2005
  • The quality factors for cylindrical ionization chambers for kV X-rays were determined by Monte Carlo calculation and measurement. In this study, the X-rays of 60-300 kV beam (lSO-4037) installed in KFDA and specified in energy spectra and beam qualities, and the chambers of PTW N23333 and N30001 were investigated. In calculations, the $R_{\mu}\;and\;R_{Q,Q_{0}}$ in IAEA dosimetry protocols were determined from the air kerma and the cavity dose obtained by theoretical and Monte Carlo calculations. It is shown that the N30001 chamber has a flat response of $\pm1.7\%$ in $110\~300kV$ region, while the response range of two chambers were shown to $\pm3\~4\%$ in $80\~250kV$ region. From this work we have discussed dosimetry protocol for the kV X-rays and we have found that the estimation of energy dependency is more important to apply dosimetry protocol for kV X-rays.

  • PDF

A Collaborative Study to Establish the Second Korean National Reference Standard for Snake Venom

  • Han, Kiwon;Jung, Kikyung;Oh, Hokyung;Song, Hojin;Park, Sangmi;Kim, Ji-Hye;Min, Garam;Lee, Byung-Hwa;Nam, Hyun-sik;Kim, Yang Jin;Ato, Manabu;Jeong, Jayoung;Ahn, Chiyoung
    • Toxicological Research
    • /
    • v.34 no.3
    • /
    • pp.191-197
    • /
    • 2018
  • In 2015, a candidate for the second national reference standard (NRS) of Gloydius snake venom was produced to replace the first NRS of Gloydius snake venom. In the present study, the potencies of the candidate were determined by a collaborative study, and the qualification of the candidate was estimated. The potencies of the candidate were determined by measuring the murine lethal titers and lapine hemorrhagic titers of venom against the regional working reference standard (RWRS) for antivenom using the methods described in the previous report for the first NRS of Gloydius snake venom. Three Korean facilities contributed data from a total of 30 independent assays. Subsequently, two foreign national control research laboratories contributed to this collaborative study. The results were calculated using the Reed-Muench method for lethality and determined using a mixed-effects model for hemorrhage. The general common potencies of the lethal and hemorrhagic titers were obtained from the results of the 30 tests performed at three Korean facilities. The results are expressed in micrograms for 1 test dose (TD) with a 95% confidence interval as follows: a lethal titer of $90.13{\mu}g/TD$ (95% confidence interval = $87.39{\sim}92.86{\mu}g$) and a hemorrhagic titer of $10.80{\mu}g/TD$ (95% confidence interval = $10.46{\sim}11.14{\mu}g$). In addition, the candidate preparation showed good quality evaluation according to the results of the quality estimation of the candidate and is judged to be suitable to serve as the Korean NRS for snake venom. In conclusion, the second NRS of Gloydius snake venom was established in this study and will be used for national quality control, including a national lot release test of Korean antivenom products.

Optimum Mixing Ratio of Bulking Agent for Garbage Composting (음식쓰레기 퇴비화시 bulking agent의 적정 첨가량 결정에 관한 연구)

  • Shin, Hang-Sik;Hwang, Eung-Ju;Jeong, Yeon-Koo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.2 no.1
    • /
    • pp.75-86
    • /
    • 1994
  • Garbage composting was studied in a controlled batch reactor with the addition of cooked rice as a biodegradable carbon source to find the effect of C/N ratio control on composting. And composting of bulking agents such as sawdust and wheat straw were tested with the addition of ammonium sulfate as a nitrogen source. As expected, biodegradation of the garbage having low C/N ratio was improved to some extent when foreign carbon was added. But bulking agents used in this study exerted slightly biodegradable carbon potential, indicating that the estimation of the dose of additional carbon considering desirable C/N ratio was not reasonable when lignocellulosic bulking material was added to garbage. It was found that the optimum moisture content increased with sawdust addition meaning the C/N ratio increment. Considering the above results, it was suggested that 78g sawdust per 100g garbage should be mixed to make C/N ratio to 25 and moisture content to 56% for effective composting of the garbage studied in this paper.

  • PDF

Estimation of Estrogenic Activity by E-screen Assay and Stepwise Analysis of Endocrine Disruptors in Pilot Sewage Treatment Plant (파일럿 규모의 하수 처리 공정별 E-screen Assay에 의한 에스트로겐 활성과 내분비계 장애물질의 농도 평가)

  • Lee, Ji-Ho;Park, Jong-Yol;Ra, Jin-Sung;Duong, Cuong N.;Lee, Byoung-Cheun;Kim, Sang-Don
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.7
    • /
    • pp.697-703
    • /
    • 2006
  • Endocrine disruptors were measured with GC/MS in effluents discharged from sewage treatment processes in pilot scale for the purpose of water reuse. From that analysis, we compared the removal rate of them by treatment processes. Nonylphenol was mainly detected in effluents and high concentration from 0.36 to 0.94 ${\mu}g/L$. $17{\beta}$-estradiol(E2) and $17{\alpha}$-ethynylestradiol(EE2) were detected as below the limit of detection in effluent. Endocrine disruptors were removed effectively in the range from 50 to 100% by treatment process. EC50 value($9.0{\times}10^{-3}$ M) of $17{\beta}$-estradiol(E2) by dose response curve of E-screen assay has higher than that of bisphenol A($2.736{\times}10^{-5}M$) and p-octylphenol($9.760{\times}10^{-6}$ M). These results showed that alkylphenols have lower relative estrogen potency than other estrogens such as $17{\beta}$-estradiol(E2). Calculated estrogenic activity(ng-EEQ/L) was 2 times higher than measured total estrogenic activity which estimated by E-screen assay. Moreover estrogenic activity of effluent by treatment process showed very low as below 1 ng-EEQ/L.