• Title/Summary/Keyword: Dose Distribution

Search Result 1,179, Processing Time 0.025 seconds

Distribution and accumulation of 177Lu-labeled thermally cross-linked superparamagnetic iron oxide nanoparticles in the tissues of ICR mice

  • Hue, Jin Joo;Lee, Hu-Jang;Nam, Sang Yoon;Kim, Jong-Soo;Lee, Beom Jun;Yun, Young Won
    • Korean Journal of Veterinary Research
    • /
    • v.55 no.1
    • /
    • pp.57-60
    • /
    • 2015
  • To investigate kinetics of free $^{177}Lu$ and $^{177}Lu$-labeled thermally cross-linked superparamagnetic iron oxide nanoparticles (TCL-SPION), suspensions were intravenously injected into the tail vein of mice at a dose of $5{\mu}Ci$/mouse or 15 mg/kg body weight, respectively. Free $^{177}Lu$ radioactivity levels were highest in kidney followed by liver and lung 1 day post-injection. $^{177}Lu$-labeled TCL-SPION radioactivity in liver and spleen was significantly higher compared to that of other organs throughout the experimental period (p < 0.05). Radioactivity in blood, brain, and epididymis rapidly declined until 28 days. Based on these results, TCL-SPION could be a safe carrier of therapeutics.

A Development of Lagrangian Particle Dispersion Model (Focusing on Calculation Methods of the Concentration Profile) (라그란지안 입자확산모델개발(농도 계산방법의 검토))

  • 구윤서
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.6
    • /
    • pp.757-765
    • /
    • 1999
  • Lagrangian particle dispersion model(LPDM) is an effective tool to calculate the dispersion from a point source since it dose not induce numerical diffusion errors in solving the pollutant dispersion equation. Fictitious particles are released to the atmosphere from the emission source and they are then transported by the mean velocity and diffused by the turbulent eddy motion in the LPDM. The concentration distribution from the dispersed particles in the calculation domain are finally estimated by applying a particle count method or a Gaussian kernel method. The two methods for calculating concentration profiles were compared each other and tested against the analytic solution and the tracer experiment to find the strength and weakness of each method and to choose computationally time saving method for the LPDM. The calculated concentrations from the particle count method was heavily dependent on the number of the particles released at the emission source. It requires lots fo particle emission to reach the converged concentration field. And resulting concentrations were also dependent on the size of numerical grid. The concentration field by the Gaussian kernel method, however, converged with a low particle emission rate at the source and was in good agreement with the analytic solution and the tracer experiment. The results showed that Gaussian kernel method was more effective method to calculate the concentrations in the LPDM.

  • PDF

Immunological Assay to Detect Irradiated Beef

  • Lee, Ju-Woon;Yook, Hong-Sun;Lee, Hyun-Ja;Kim, Jung-Ok;Byun, Myung-Woo
    • Preventive Nutrition and Food Science
    • /
    • v.6 no.2
    • /
    • pp.91-95
    • /
    • 2001
  • Competitive indirect enzyme linked immunosorbent assay (Ci-ELISA) was used to obtain the preliminary data for the detection of irradiated beef. Ci-ELISA was individually formatted with polyclonal antibodies produced from 2 kinds of bovine proteins, myosin and bovine serum albumin (BSA). Beef round, loin and tender loin were vacuum-packaged and subdivided into 3 groups of 1) irradiation; 2) irradiation and chilled at 4$^{\circ}C$ for 7 day; 3) irradiation and frozen at 2$0^{\circ}C$ for 2 months to observe the changes under different storage and/or distribution conditions. Irradiation was performed at 3, 5 and 7 kGy. Protein solutions prepared from the sample were tested by formatted Ci-ELISA. Detected concentrations of myosin and BSA decreased with the increased irradiation dose in all samples with different reduction rates. Myosin was more susceptible to freezing than BSA. Samples irradiated at 5 kGy or above could be differentiated from non-irradiated ones by Ci-ELISA. These results indicate that immunological assay can be used as a detection method for irradiated beef.

  • PDF

Preliminary Study on the Elemental Quantification of in Ambient Liquid Samples of Microliter Volume Using the In-air Micro-PIXE Technique

  • Ma, Chang-Jin;Lim, Cheol-Soo;Sakai, Takuro
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.1
    • /
    • pp.54-60
    • /
    • 2017
  • Quantifying the trace elements in infinitesimal ambient liquid samples (e.g., single raindrop, cloud/fog water, and the soluble fraction extracted from the particles collected for a short time) is an important task for understanding formation processes, heating/cooling rates, and their health hazards. The purpose of this study is to employ an in-air micro PIXE system for quantitative analysis of the trace elements in a thimbleful of reference liquid sample. The bag type liquid sample holder originally designed with $10{\mu}m$ thick $Mylar^{(R)}$ film retained the original shape without any film perforation and apparent peaks of film blank by the end of the analysis. As one of tasks to be solved, the homogeneity of the elemental distribution in liquid reference species was verified by the X-ray line profiles for several references. It was possible to resolve the significant peaks for whole target elements corresponding to the channel number of micro-PIXE spectrum. The calibration curves for the six target elements (Si, S, Cl, Fe, Ni, and Zn) in standard solutions were successfully plotted by concentration (ppm) and ROI of interest net counts/dose (nC).

The Measurement of Dose Distribution in the Presence of Air Cavity and Underdosing Effect Result from Lack of Electronic Equilibrium (조사면 내 공동의 존재에 따른 선량분포의 변화측정)

  • Cho, Jung-Hee
    • Journal of radiological science and technology
    • /
    • v.19 no.1
    • /
    • pp.81-87
    • /
    • 1996
  • When high energy photon beam is incident upon an air cavity interface the effect of ionization build-up observed. This phenomenon is resulting from the surface layers of the lesions are significant deficiency of electrons reaching the layers because of the replacement of solid scattering material by the air cavity, that is lack of electronic equilibrium. Measurement have been made in an acrylic phantom with a parallel plate chamber and high energy Photon beams, CO-60, 4MV, 6MV and 10MV X-rays have been investigated. The result of our study show that a significant effect was measured and was determined to be very dependent on field size, air cavity dimension and photon energy. The reductions were much larger for 10MV beam, underdosage at the interface was 12, 12.2, 16.9 and 20.6% for the CO-60, 4 MV, 6MV and 10MV, respectively. It was found that this non-equilibrium effect at the interface is more severe for the higher energy beams than that of lower energy beams and the larger cavity dimensions it is, the larger beam reductions we have. This problem is of clinical concern when lesions such as carcinoma beyond air cavities are irradiated, such as larynx, glottic and the patients with maxillectomy and ethmoidectomy and so forth.

  • PDF

A Critical Review for the Effect of Ozonation on Biodegradability in Drinking Water Treatment Systems (전오존처리에 의한 상수원수의 생물학적 처리효율제고에 관한 연구)

  • Nam, Sang-Ho
    • 수도
    • /
    • v.24 no.4 s.85
    • /
    • pp.79-87
    • /
    • 1997
  • In an effort to prevent the formation of DBPs from disinfection and the microbial regrowth in distribution systems, the ozonation followed by biological filtration process in drinking water treatment train has been recently developed as an alternative process to reduce effectively water-born organic matter as precursor. There are, however, insufficient for the consistent information and data about the relation between ozone dosage based on organic surrogate parameter, TOC or DOC and effect of ozonation on BDOC formation. This study is to review critically for the effect of ozonation on biodegradability on the basis of published technical papers including the output from author's research laboratory. It truned out that : 1. ozonation in the presence of organic matter has a tendancy to increase in BDOC content, 2. the rate of BDOC formation was maximum below 1mg $O_3/mg$ DOC of ozone dose, but about maximum content of BDOC was obtainable at the range from 1.5mg $O_3/mg$ DOC to 2mg $O_3/mg$ DOC, 3. from above 1mg $O_3/mg$ DOC, the rate of BDOC formation became slow down, 4. from above 2mg $O_3/mg$ DOC, BDOC formation was quantitatively negligible, In conclusion, it needs further systematic study and research concerned to biodegradability and treatability by ozonation in terms of organic characteristics and experimental conditions because it was hard to find out the consistent experimental data comparable each other that were performed by numbers of research authors.

  • PDF

Lonicera Japonica Inhibits Atopy Dermatitis in NC/Nga Mouse through Regulation of iNOS by NF-${\kappa}B$ Suppression (금은화의 NF-${\kappa}B$ 활성 억제를 통한 iNOS 조절이 NC/Nga 생쥐의 아토피 피부염에 미치는 영향)

  • Ahn, Sang-Hyun;Kim, Ho-Hyun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.24 no.2
    • /
    • pp.278-283
    • /
    • 2010
  • Inducible nitric oxide synthase (iNOS) are important inflammation enzyme and severe up-nitric oxide (NO) production by this enzyme has been intricate with pathogenesis of atopy dermatitis. The present study was designed in order to determine whether Lonicera japonica could inhibit atopy dermatitis through modulation of iNOS by NF-${\kappa}B$ suppression. We found that IKK mRNA and iNOS mRNA expression in RAW 264.7 macrophages stimulated with lipopolysaccharide dose-dependantly decreased by Lonicera japonica (0.4 - 1.0 mg/$m{\ell}$) and NO production decreased. The distribution of NF-${\kappa}B$ p65 and iNOS positive reacted cell in NC/Nga mice with atopy dermatitis were decreased by Lonicera japonica (45 mg/kg/day) and apoptosis were increased. These data likely indicate that Lonicera japonica may act as inflammatory regulator for atopy dermatitis through iNOS modulation by NF-${\kappa}B$B suppression and may be possible to develop useful agent for chemoprevention of NO intricate inflammatory diseases.

Development and Characteristics of the Soft x-ray transmission W-target tube (W-target 투과 양극형 Soft x-ray tube의 개발 및 특성분석)

  • Kim, Sung-Soo;Kim, Do-Yun
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.4
    • /
    • pp.305-310
    • /
    • 2007
  • The x-ray transmission W-target tube was developed and its characteristics were evaluated. The continuous x-ray was emitted at the tube voltage less than 12kV, and the characteristic x-ray was emitted more than 12kV. From the measurement of the energy distribution and dose of x-ray, it was confirmed that our results are a good agreement with the blown ones. Moreover, in comparison with commercial x-ray tube, it was also found that the characteristics of our x-ray tube is better than the commercial one. Therefore we confirmed that the x-ray tube developed in this study is so good that it can be commercialized.

The Significance of the Analytical Sciences In Environmental Assessment

  • Chung, Yong;Ahn, Hye-Won
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.1079-1087
    • /
    • 1995
  • The quality of human life is directly related to the quality of the environment. To assess environmental quality we must first determine the MCLG(Maximum Contaminant Level Goal), MCL(Maximum Contaminant Level), environmental impact and so on. The MCLG is the concentration at which no known adverse health effects occur. The MCLG is determined by risk assessment identifying which process is hazardous assessing, dose-response, human exposure, and characteristics of risk. With consideration of analytical methods, treatment technology, cost and regulatory impact, the MCL is set as close to the MCLG as possible. In this way, determination of the concentration and national distribution of contaminants is important for assessment of environmental quality The analytical sciences pose potential problems in assessing environmental quality. Continuing improvement in the performance of analytical instruments and operating technique has been lowering the limits of detectability. Contaminant concentration below the detection limit has usually been reported as ND(Not-Detected) and this has often been misunderstood as equivalent to zero. Because of this, more the contaminant concentration in the past was below the detection limit, whereas contaminants can be quantified now even though the contaminant concentration might remain the same or may even have decreased. In addition, environmental sampling has various components due to heterogeneous matrices. These samples are used to overestimate the concentration of the contaminant due to large variability, resulting in excess readings for MCL. In this paper, the significance of the analytical sciences is emphasized in both a conceptual and a technical approach to environmental assessment.

  • PDF

The Effect of Iridium-192 Implant in the Treatment of Head and Neck Cancer (두경부암에서 방사성이리디움 삽입치료의 효과)

  • Yoo Seong-Yul;Koh Kyoung-Hwan;Cho Chul-Koo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.4 no.1
    • /
    • pp.13-19
    • /
    • 1988
  • Brachytherapy is known to be a good modality to achieve local control as a boost treatment following limited external irradiation, which may reduce the external beam related acute radiation sickness, particularly in head and neck cancer. The authors developed iridium-192 ribbons recently to replace the radium needles. Total of 13 head and neck cancer patients had been treated with Ir-192 ribbons during last one year from October 1986 to September 1987, and the results were analysed to assess the applicability of the fabricated sources. The conclusion is as follows; 1) Iridium implant achieved 54% (7/13) of complete response and 69% (9/13) of overall response rate in head and neck cancer. 2) Iridium is superior to radium and cecium in brachytherapy because of easier to use and lesser exposure to the personnel. 3) Afterloading technique is useful to modify dose distribution, to expand treatment site and method, and to develop interstitial hyperthermia.

  • PDF