• Title/Summary/Keyword: Dose Coefficient

Search Result 271, Processing Time 0.025 seconds

Effect of Propofol, an Intravenous Anesthetic Agent, on $K_{ATP}$ Channels of Pancreatic ${\beta}-cells$ in Rats

  • Park, Eun-Jee;Song, Dae-Kyu;Cheun, Jae-Kyu;Bae, Jung-In;Ho, Won-Kyung;Earm, Yung-E
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.4 no.1
    • /
    • pp.25-31
    • /
    • 2000
  • ATP-sensitive potassium channels ($K_{ATP}$ channels) play an important role in insulin secretion from pancreatic beta cells. We have investigated the effect of propofol on $K_{ATP}$ channels in cultured single pancreatic beta cells of rats. Channel activity was recorded from membrane patches using the patch-clamp technique. In the inside-out configuration bath-applied propofol inhibited the $K_{ATP}$ channel activities in a dose-dependent manner. The half-maximal inhibition dose (ED50) was $48.6{\pm}8.4\;{\mu}M$ and the Hill coefficient was $0.73{\pm}0.11.$ Single channel conductance calculated from the slope of the relationship between single channel current and pipette potential $(+20{\sim}+100\;mV)$ was not significantly altered by propofol $(control:\;60.0{\pm}2.7\;pS,\;0.1\;mM\;propofol:\;58.7{\pm}3.5\;pS).$ However, mean closed time was surely increased. Above results indicate that propofol blocks the $K_{ATP}$ channels in the pancreatic beta cells in the range of its blood concentrations during anesthesia, suggesting a possible effect on insulin secretion and blood glucose level.

  • PDF

An Improved, Reliable and Practical Kinetic Assay for the Detection of Prekallikrein Activator in Blood Products

  • Shin, In-Soo;Shim, Yun-Bo;Hong, Choong-Man;Koh, Hyun-Chul;Lee, Seok-Ho;Hong, Seung-Hwa
    • Archives of Pharmacal Research
    • /
    • v.25 no.4
    • /
    • pp.505-510
    • /
    • 2002
  • An improved kinetic assay for prekallikrein activator (PKA), a potential vasodilator, has been developed to be used as an indicator for quality control during production of human albumin preparations. It consists of two reaction stages. In the first stage, PKA and prekallikrein are incubated at $37^{\circ}C$ for 45 min to allow the transformation into kallikrein. Kallikrein, a serine protease, catalyzes the splitting of p-nitroaniline (pNA) from its substrate H-D-Pro-Phe-Arg-pNA(S-2302). The rate at which pNA is released was measured spectrophotometrically at 405 nm. Prekallikrein, a substrate of PKA was purified by DEAE ion-exchange chromatography and the major potential variations in the assay were optimized; pH 8.0 and 150 mM sodium chloride were chosen to give a proper ionic strength. Reaction times in the range of 10 to 360 min provided linear dose-response curves. The concentration of prekallikrein was adjusted to fall between 1:1 and 1:3 dilutions to generate a linear standard calibration curve. Under the optimized conditions, reproducibility was checked. In a precision test, the coefficient of variation (CV) stayed within ${\pm}4%$ and the dose-response curve showed a good correlation (${r^2}=0.999$). An accuracy test with an international standard of PKA afforded a mean recovery of 97.5%.

Analysis of Pembrolizumab-induced Blood Glucose Level Change in Cancer Patients (암환자에서 Pembrolizumab 투여로 인한 혈당수치 변화 분석)

  • Jung, Hee Yoon;Hong, Min-Soo;Jung, Woo Jin;Choi, Sun Ok;Chae, Jung-woo;Yun, Hwi-yeol
    • Korean Journal of Clinical Pharmacy
    • /
    • v.31 no.3
    • /
    • pp.237-246
    • /
    • 2021
  • Background: Pembrolizumab, an anti-cancer drug, is known to increase the activity of the immune system, leading to side effects called immune-related adverse events (irAE), including type 1 diabetes. This study analyzed the correlation between blood glucose level and pembrolizumab administration and investigated the covariates that affect those changes in cancer treatment. Methods: The information of 133 adult cancer patients was obtained from the electronic medical record (EMR) to identify the changes in random blood glucose (RBG) levels during the pembrolizumab treatment. Subjects were classified into subgroups according to their baseline RBG level, history of diabetes, and the use of steroids, and linear regression analysis was conducted. In addition, a secondary analysis was performed within the group of subjects having a strong correlation to glycemic change, which was based on the Pearson correlation coefficient being less than -0.7 or greater than +0.7. Univariate and multivariate logistic regressions were conducted to identify the risk factors to glycemic increase. Results: The RBG level tended to descend without significant differences in total patients during the administration period of pembrolizumab. Despite the insignificance, the logistic regression analysis presents that the odds ratios of baseline RBG less than 130 mg/dL, prophylactic steroid use, and higher dose of pembrolizumab per cycle (mg/kg/cycle) were greater than 1. Conclusions: Prophylactic administration of steroids and a higher dose of pembrolizumab per cycle may increase the blood glucose level as irAE in cancer patients with a strong tendency to glycemic change.

Proposal of CT Simulator Quality Assurance Items (전산화단층 모의치료장치의 정도관리 항목 제안)

  • Kim, Yon-Lae;Yoon, Young-Woo;Jung, Jae-Yong;Lee, Jeong-Woo;Chung, Jin-Beom
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.367-373
    • /
    • 2021
  • A quality assurance of computed tomography(CT) have done seven items that were water attenuation coefficient, noise, homogeneity, spatial resolution, contrast resolution, slice thickness, artifact using by standard phantom. But there is no quality assurance items and methods for CT simulator at domestic institutions yet. Therefore the study aimed to access the CT dose index(CTDI), table tilting, image distortion, laser accuracy, table movement accuracy and CT seven items for CT simulator quality assurance. The CTDI at the center of the head phantom was 0.81 for 80 kVp, 1.55 for 100 kVp, 2.50 for 120 mm, 0.22 for 80 kVp at the center of the body phantom, 0.469 for 100 kVp, and 0.81 for 120 kVp. The table tilting was within the tolerance range of ±1.0° or less. Image distortion had 1 mm distortion in the left and right images based on the center, and the laser accuracy was measured within ±2 mm tolerance. The purpose of this study is to improve the quality assurance items suitable for the current situation in Korea in order to protect the normal tissues during the radiation treatment process and manage the CT simulator that is implemented to find the location of the tumor more clearly. In order to improve the accuracy of the CT simulator when looking at the results, the error range of each item should be small. It is hoped that the quality assurance items of the CT simulator will be improved by suggesting the quality assurance direction of the CT simulator in this study, and the results of radiation therapy will also improve.

Evaluation of Application of 3D Printing Phantom According to Manufacturing Method (구성 물질에 따른 3D 프린팅 팬텀의 적용 평가)

  • Young Sang Kim;Ju Young Lee;Hoon Hee Park
    • Journal of Radiation Industry
    • /
    • v.17 no.2
    • /
    • pp.173-181
    • /
    • 2023
  • 3D printing is a technology that can transform and process computerized data obtained through modeling or 3D scanning via CAD. In the medical field, studies on customized 3D printing technology for clinical use or patients and diseases continue. The importance of research on filaments and molding methods is increasing, but research on manufacturing methods and available raw materials is not being actively conducted. In this study, we compare the characteristics of each material according to the manufacturing method of the phantom manufactured with 3D printing technology and evaluate its usefulness. We manufactured phantoms of the same size using poly methyl meta acrylate (PMMA), acrylonitrile butadiene styrene (ABS), and Poly Lactic Acid (PLA) based on the international standard phantom of aluminum step wedge. We used SITEC's radiation generator (DigiRAD-FPC R-1000-150) and compared the shielding rate and line attenuation coefficient through the average after shooting 10 times. As a result, in the case of the measured dose transmitted through each phantom, it was confirmed that the appearance of the dose measured for phantoms decreased linearly as the thickness increased under each condition. The sensitivity also decreased as the steps increased for each phantom and confirmed that it was different depending on the thickness and material. Through this study, we confirmed that 3D printing technology can be usefully used for phantom production in the medical field. If further development of printing technology and studies on various materials are conducted, it is believed that they will contribute to the development of the medical research environment.

Research of Protocols for Optimization of Exposure Dose in Abdominopelvic CT - (복부-골반 CT검사 시 피폭선량 최적화에 관한 프로토콜 연구)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.245-251
    • /
    • 2017
  • This study measured the exposure dose during abdominal-pelvic CT exam which occupies 70% of CT exam and tried to propose a protocol for optimized exposure dose in abdomen and pelvis without affecting the imagery interpretation. The study scanned abdomen-pelvis using the current clinical scan method, the 120 kVp, auto exposure control(AEC), as 1 phase. As for the newly proposed 2 phase scan method, the study divided into 1 phase abdomen exam and 2 phase pelvis exam and each conducted tube voltage 120 kVp, AEC for abdomen exam, and fixed tube current method in 120 kVp, 100, 150, 200, 250, 300, 350, 400 mA for pelvis exam. The exposure dose value was compared using $CTDI_{VOL}$, DLP value measured during scan, and average value of CT attenuation coefficient, noise, SNR from each scan image were obtained to evaluate the image. As for the result, scanning of 2 phase showed significant difference compared to 1 phase. In $CTDI_{VOL}$ value, the 2 phase showed 26% decrease in abdomen, 1.8~59.5% decrease in pelvis for 100~250 mA, 12.7%~30% increase in pelvis for 300~400 mA. Also, DLP value showed 53% decrease in abdomen and 41~81% decrease in pelvis when scanned by 2 phase compared to 1 phase, but it was not statistically significant. As for the SNR, when scanning 2 phase close to heart, scanning 1 phase close to pelvis, scanning and scanning 1 phase at upper and lower abdomen, it was higher when scanning 2 phase for 200~250 mA. Also, the CT number and noise was overall similar, but the noise was high close to pelvis. However, when scanning 2 phase for 250 mA close to pelvis, the noise value came out similar to 1 phase, and did not show statistically significant difference. It seems when separating pelvis to scan in 250 mA rather than 400 mA in 1 phase as before, it is expected to have reduced effect of exposure dose without difference in the quality of image. Thus, for patients who often get abdominal-pelvic CT exam, fertile women or children, this study proposes 2 phase exam for smaller exposure dose with same image quality.

Characteristics of the Graded Wildlife Dose Assessment Code K-BIOTA and Its Application (단계적 야생동식물 선량평가 코드 K-BIOTA의 특성 및 적용)

  • Keum, Dong-Kwon;Jun, In;Lim, Kwang-Muk;Kim, Byeong-Ho;Choi, Yong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.252-260
    • /
    • 2015
  • This paper describes the technical background for the Korean wildlife radiation dose assessment code, K-BIOTA, and the summary of its application. The K-BIOTA applies the graded approaches of 3 levels including the screening assessment (Level 1 & 2), and the detailed assessment based on the site specific data (Level 3). The screening level assessment is a preliminary step to determine whether the detailed assessment is needed, and calculates the dose rate for the grouped organisms, rather than an individual biota. In the Level 1 assessment, the risk quotient (RQ) is calculated by comparing the actual media concentration with the environmental media concentration limit (EMCL) derived from a bench-mark screening reference dose rate. If RQ for the Level 1 assessment is less than 1, it can be determined that the ecosystem would maintain its integrity, and the assessment is terminated. If the RQ is greater than 1, the Level 2 assessment, which calculates RQ using the average value of the concentration ratio (CR) and equilibrium distribution coefficient (Kd) for the grouped organisms, is carried out for the more realistic assessment. Thus, the Level 2 assessment is less conservative than the Level 1 assessment. If RQ for the Level 2 assessment is less than 1, it can be determined that the ecosystem would maintain its integrity, and the assessment is terminated. If the RQ is greater than 1, the Level 3 assessment is performed for the detailed assessment. In the Level 3 assessment, the radiation dose for the representative organism of a site is calculated by using the site specific data of occupancy factor, CR and Kd. In addition, the K-BIOTA allows the uncertainty analysis of the dose rate on CR, Kd and environmental medium concentration among input parameters optionally in the Level 3 assessment. The four probability density functions of normal, lognormal, uniform and exponential distribution can be applied.The applicability of the code was tested through the participation of IAEA EMRAS II (Environmental Modeling for Radiation Safety) for the comparison study of environmental models comparison, and as the result, it was proved that the K-BIOTA would be very useful to assess the radiation risk of the wildlife living in the various contaminated environment.

The Effects of Lead Exposure on Hematocrit ana Hemoglobin (연폭로시 혈구용적치 및 혈색소치의 변화)

  • Lee, Se-Hoon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.13 no.1
    • /
    • pp.41-46
    • /
    • 1980
  • In order to study the effect of lead exposure on the hematocrit and hemoglobin values in accordance with the level of lead exposure, twenty-four Sprague-Dawley rats were equally divided into four groups of six rats each. Lead acetate disolved in glucose was injected intraperitoneally six times a week, for four weeks with dose of 0.05 mg/kg/day for group I, 0.5 mg/kg/day for group II, and 5 mg/kg/day for group III. Control group was injected glucose only. Blood samples for the checking of the hematocrit and hemoglobin values, were taking from tail vein of rats before lead injection and on the third, seventh, fourteenth, twenty-first, and twenty-eighth days after lead injection. And also, the concentration of lead and ALA in urine were checked for evaluating the lead absorption. The results were as follows: 1. The alteration of the hematocrit and hemoglobin values of the group I was not significant as that of the control group. 2. In group II, the hematocrit values were significantly decreased from the fourteenth day after lead injection, and the hemoglobin values were decreased from the twenty-first day after lead injection when the concentration of lead in urine was elevated more than $260{\mu}g/liter$. 3. In group III, the hematocrit values were decreased from the seventh day after lead injection, and the hemoglobin values were decreased even from the third day after lead injection. And the hemoglobin values were more rapidly decreased than the hematocrit values. 4. In all groups, the correlation coefficient between hematocrit and hemoglobin was highly significant. And the difference between the correlation coefficient of the group III and that of the others was highly significant.

  • PDF

A Study on the Development of Low Reynolds Number k-$\varepsilon$ Turbulence Model (저레이놀즈수 k-$\varepsilon$난류모형 개선에 관한 연구)

  • 김명호;신종근;최영돈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.10
    • /
    • pp.1940-1954
    • /
    • 1992
  • Fine grid computations were attempted to analyze the turbulent flows in the near wall low Reynolds number region and the numerical analyses were incorporated by a finite-volume discretization with full find grid system and low Reynolds number k-.epsilon. model was employed in this region. For the improvement of low Reynolds number k-.epsilon. model, modification coefficient of eddy viscosity $f_{\mu}$ was derived as a function of turbulent Reynolds number $R_{+}$ and nondimensional length $y^{+}$ from the concept of two length scales of dissipation rate of turbulent kinetic energy. The modification coefficient $f_{\epsilon}$ in .epsilon. transport equation was also derived theoretically. In the turbulent kinetic energy equation, pressure diffusion term was added in order to consider low Reynolds number region effect. The main characteristics of this low Reynolds number k-.epsilon. model were founded as : (1) In high Reynolds number region, the present model has limiting behavior which approaches to the high Reynolds number model. (2) Present low Reynolds number k-.epsilon. model dose not need additional empirical constants for the transport equations of turbulent kinetic energy and dissipation of turbulent kinetic energy in order to consider wall effect. Present low Reynolds number turbulence model was tested in the pipe flow and obtained improved results in velocity profiles and Reynolds stress distributions compared with those from other k-.epsilon. models.s.s.

Vitamin C Tablet Assay by Near -Infrared Reflectance spectrometry

  • Kargosha, Kazem;Ahmadi, Hamid;Nemati, Nader
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.4111-4111
    • /
    • 2001
  • When a drug is prepared in a tablet, the active component represents only a small portion of the dosage form. The other components of the formulation include materials to assist in the dissolution, antioxidants, coloring agents and bulk fillers. The tablets are tested using approved testing methods usually involving separation and subsequent quantification of the active component. Tablets may also be tested by near-Infrared Reflectance spectrometry (NIRS). In the present study, based on NIRS and multivariate calibration methods, a novel and precise method is developed for direct determination of ascorbic acid in vitamin C tablet. Two different tablet formulations were powdered in three different sizes, 63-125 ${\mu}{\textrm}{m}$, and examined. Spectral region of 4750-4950 $cm^{-1}$ / was used and optimized for quantitative operations. Partial least squares (PLS) and multiple linear regression (MLR) methods were performed for this spectral region. The results of optimized PLS and MLR methods showed that reproducibility increase with decreasing grain size and standard error of calibration (SEP) of less than 1% w/w of ascorbic acid and a correlation coefficient of 0.998 can be achieved. The PLS method showed better results than MLR. Seven overdose and underdose samples (prepared in the laboratory to match marketed products) were tested by proposed and iodometric standard methods. A correlation between NIRS predicted ascorbic acid values and iodomet.ic values was calculated ($R^2$=0.9950). Finally, the direct analysis of individual intact tablets in their unit-dose packages (Blistering in aluminum and PVC foils) obtained from market were also carried out and a correlation coefficient of 0.9989 and SEP of 0.931% w/w of ascorbic acid were achieved.

  • PDF