• Title/Summary/Keyword: Doppler scanning

Search Result 42, Processing Time 0.033 seconds

Damage Detection on Thin-walled Structures Utilizing Laser Scanning and Standing Waves (레이저 스캐닝 및 정상파를 이용한 평판 구조물의 손상탐지)

  • Kang, Se Hyeok;Jeon, Jun Young;Kim, Du Hwan;Park, Gyuhae;Kang, To;Han, Soon Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.5
    • /
    • pp.401-407
    • /
    • 2017
  • This paper describes wavenumber filtering for damage detection using single-frequency standing wave excitation and laser scanning sensing. An embedded piezoelectric sensor generates ultrasonic standing waves, and the responses are measured using a laser Doppler vibrometer and mirror tilting device. After scanning, newly developed damage detection techniques based on wavenumber filtering are applied to the full standing wave field. To demonstrate the performance of the proposed techniques, several experiments were performed on composite plates with delamination and aluminum plates with corrosion damage. The results demonstrated that the developed techniques could be applied to various structures to localize the damage, with the potential to improve the damage detection capability at a high interrogation speed.

Vibration Characteristics Analysis as Laser Welding Condition by ESPI (ESPI에 의한 레이저용접 조건에 따른 진동 특성 분석)

  • Kim K.S.;Jung H.C.;Baek S.K.;Lee Y.H.;You D.N.
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.349-353
    • /
    • 2005
  • This paper describes the variations of resonance frequencies and vibration mode shapes of laser welded cold rolled carbon steel plate(SCP1) induced by thermal loading during laser welding processing. The characteristics of those are analyzed with stroboscopic ESPI. Electronic speckle pattern interferometry (ESPI) that the electronic processes were added to SPI is one of the very powerful method in the experimental vibration analysis field. Stroboscopic ESPI to make it reliable are compared with theory and experimental method: Finite Element Method(FEM) and Scanning Laser Doppler Vibrometer(SLDV). The results of stroboscopic ESPI are well agreed with SLDV and also the comparison with theory give good agrement within $5\%$.

  • PDF

Investigation of the Performance of Spectral Domain Optical Doppler Tomography with High-speed Line Scanning CMOS Camera and Its Application to the Blood Flow Measurement in a Micro-tube

  • Park, Cheol Woo;Lee, Changho;Lim, SooHee;Ni, Aleksey;An, Jin Hyo;Lee, Ho;Bae, Jae Sung;Kim, Jeehyun
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.174-180
    • /
    • 2012
  • In this study, the feasibility of spectral domain optical Doppler tomography for measuring blood flow characteristics in a micro-tube was demonstrated through several experiments. The use of an SD-ODT system in blood flow measurement can provide high resolution images (5 microns resolution). We prepared three capillary tubes to reveal the effect of different concentrations of hematocrit ratio (HR). One tube serves as the control. The two other tubes contained different concentrations of HR (5%, 25%). Three different capillary tube inlet flow velocities were tested in the present study. The Reynolds number (Re) which is based on the capillary tube inner diameter ranges from Re=6 to 48. We calculated a Doppler shift of the power spectrum of the temporal interference fringes with Kasai autocorrelation function to achieve the velocity profile of the flow. As a result, SD-ODT systems could not detect the cell depletion layer in the present study due to the limitation of spatial resolution. Nevertheless, these systems were proven to be capable of observing the RBCs of blood.

Chromospheric Sunspot Oscillations in H-alpha and Ca II 8542A

  • Maurya, Ram Ajor
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.61.2-61.2
    • /
    • 2013
  • We study chromospheric oscillations including umbral flashes and running penumbral waves in a sunspot using scanning spectroscopy in H-alpha and Ca II 8542A, with the Fast Imaging Solar Spectrograph (FISS) at the 1.6 meter New Solar Telescope at Big Bear Solar Observatory. A bisector method is applied to spectral observations to construct chromospheric Doppler velocity maps. Temporal sequence analysis of these shows enhanced high-frequency oscillations inside the sunspot umbra in both lines. Their peak frequency gradually decreases outward from the umbra. The oscillation power is found to be associated with magnetic-field strength and inclination, with different relationships in different frequency bands.

  • PDF

Positron Annihilation Study of Vacancy Type Defects in Ti, Si, and BaSrFBr:Eu

  • Lee, Chong Yong
    • Applied Science and Convergence Technology
    • /
    • v.25 no.5
    • /
    • pp.85-87
    • /
    • 2016
  • Coincidence Doppler broadening and positron lifetime methods in positron annihilation spectroscopy has been used to analyze defect structures in metal, semiconductor and polycrystal, respectively. The S parameter and the lifetime (${\tau}$) value show that the defects were strongly related with vacancies. A positive relationship existed between the scanning electron microscope (SEM) images and the positron annihilation spectroscopy (PAS). According to the SEM images and PAS results, measurements of the defects with PAS indicate that it was more affected by the defect than the purity.

Experimental Modal Analysis by Using Hilbert Transform of Signal from Continuous Scanning Laser Vibrometer (연속 스캐닝 레이저 진동계 신호의 Hilbert 변환을 이용한 실험적 모드 해석)

  • Kang, Min-Sig;Chang, Tae-Gyu;Kim, Ho-Sung
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.6
    • /
    • pp.272-277
    • /
    • 2002
  • This paper deals with the vibration deflection shape measurement technique for a sinusoidally excited structure using a continuously scanning laser Doppler vibrometer (CSLV). The CSLV output signal is an amplitude-modulated vibration in which the excitation signal is modulated by the deflection shapes, and thus the deflection shapes of vibration defined along a scan line can be derived by the envelop and the phase information of the CSLV output signal. In this work, a Hilbert transform based approach has been proposed for measurement of deflection shapes. This technique is as simple as the demodulation technique and allows more convenient experimental settings than the Fourier transform approach. The feasibility of the proposed technique is illustrated along with results of experiment.

Fabrication of Biomimetic MEMS Acoustic Sensor and Analysis of Its Frequency Characteristics (MEMS 기반 생체모사 음향센서 제작 및 주파수 특성 분석)

  • Hur, Shin;Jung, Young-Do;Lee, Young-Hwa;Song, Won-Joon;Kim, Wan-Doo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.522-528
    • /
    • 2011
  • Artificial basilar membranes made of PVDF(polyvinylidene fluoride) are manufactured using microfabrication processes. The mechanical behavior of PVDF artificial basilar membrane was measured to evaluate its performance as a mechanical frequency analyzer using scanning LDV(laser Doppler vibrometer). The experimental setup consists of the microfabricated artificial basilar membrane, a loud speaker connected to an amplifier for generating acoustic pressure of specific spectral pattern, and a scanning LDV with controlling unit for measuring the displacement of the membrane on the incoming acoustic stimulation. The microfabricated artificial basilar membrane was attached tightly upon a package containing a chamber which can be filled with silicone oil before placed on the experimental setup stage. The experiment results showed that the microfabricated artificial basilar membrane has a property as a mechanical frequency analyzer.

Effect of the Bean Sprouts Growth by Scanning Frequency of Diagnostic Ultrasound Probe Type and Mode Change (진단용 초음파 Probe 및 Mode 변화에 따른 초음파 주사빈도가 콩나물 발아 과정에 미치는 영향)

  • Choi, Kwanyong;Lim, Hyun Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.150-154
    • /
    • 2015
  • Long time ultrasound scan can cause a temperature rise in human tissue and affect the physical body. This is closely connected with patients' safety. So many researchers have been studied on this matter with animals such as mammals and experimental rat, because diagnostic ultrasound has been used many types of human organ to find disease. Therefore, this study is tested on bean sprouts to search how far the tissue temperature changes because of the excessive scanning consequence from ultrasound diagnosis and frequent number of ultrasonic scanning and how much affect their growth. The United States and several European countries have restrictions for number of scanning, while South Korea does not have any limitation for using ultrasound diagnosis. Comparison was that how different condition affect its' growing. The testing group is like many pregnancy moms to have 50 minutes in B-mode and color doppler mode by linear, convex and sector probe every day for a week and the other is to scan only once during the testing period. As a result, it was confirmed that there was a significant growing difference on frequent ultrasonic scanning group compared to normal one. So the final conclusion is that there needs to have a significant limitation of ultrasound scan time and a number of inspection when having for diagnostic ultrasound and recommendation like USA and a few European countries.

The Effect of Slider Surface Texture on Flyability and Lubricant Migration under Near Contact Conditions

  • Zhou, L.;Kato, K.;Vurens, G.;Talke, F.E.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.277-278
    • /
    • 2002
  • Magnetron and Ion beam sputtering were used to texture the air-bearing surface of magnetic recording sliders. Flying height measurements and Laser-Doppler interferometry were used to compare the 'flyability' of textured and untextured sliders. Lubricant redistribution on the disk surface caused by slider/disk interactions was investigated using scanning ellipsometry (Surface Reflectance Analyzer (SRA)). The results show that slider surface texture causes only small changes in the flying height of sliders but reduces slider in-plane and out-of-plane vibrations. Textured sliders were found to cause less lubricant depletion on the disk surface than untextured sliders.

  • PDF

Vertical emission rate variations of the O2 (0-0) Atmospheric band from TIMED Doppler Interferometer (TIDI)

  • Chung, Jong-Kyun;Wu, Qian
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.24.4-25
    • /
    • 2008
  • Limb scanning measurements of the O2 (0-0) Atmospheric band emission by the TIDI instrument aboard the TIMED satellite during 2003-2005 are analyzed to examine the tidal effects on their vertical emission rate according to the solar and geomagnetic activities. The data are restricted at latitudes $60^{\circ}S-60^{\circ}N$ to avoid the contributions by the auroral emission. The variation of the vertical emission rate in latitude and local time is summarized in the yaw periods. The vertical emission profiles of the O2 (0-0) Atmospheric band nightglow averaged in the $10^{\circ}$ latitude range are investigated. The result shows the inverse relationship between the peak emission height and the integrated brightness.

  • PDF