• Title/Summary/Keyword: Doppler US

Search Result 48, Processing Time 0.022 seconds

The Measurement of Blood Flow of Anterior Cerebral Artery in Premature Newborns Using Duplex Doppler Ultrasonography (이중 초음파 검사를 이용한 미숙아의 전 뇌동맥 혈류 측정)

  • Hwang, Mi-Soo;Bae, Kyeung-Kug;Lee, Jae-Kyo
    • Journal of Yeungnam Medical Science
    • /
    • v.14 no.1
    • /
    • pp.77-84
    • /
    • 1997
  • We measured the blood flow velocity of the anterior cerebral artery via anterior fontanelle approach of fifty five preterm neonates with duplex Doppler sonography and analyzed the waveform and calculated pulsatility index, resistive index. Intracranial velocities and pulsatility indexes were increased with increasing gestational age, birth weight, and age of the neonate, but resistive indices decreased. In sick babies, characteristic resistive index increment were seen in patients with intraventricular hemorrhage, but no statistical difference was seen in patients with respiratory distress syndrome. Our results suggest that duplex Doppler sonography is a useful noninvasive means of monitoring cerebrohemodynamics in normal preterm neonates and flow change of sick babies.

  • PDF

Unusual Presentation of a Testicular Lymphoma Mimicking a Missed Testicular Torsion: A Case Report (계류 고환염전으로 오인된 드문 형태의 고환 림프종: 증례 보고)

  • Mi Jin Kim;Young Hwan Lee;Youe Ree Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1287-1291
    • /
    • 2021
  • Testicular lymphoma is an uncommon testicular tumor that usually presents as a painless mass. It usually shows hypervascularity on color Doppler ultrasound (US) and a mild enhancement on enhanced CT or MRI. We present an unusual case of a testicular lymphoma mimicking a missed testicular torsion in a 67-year-old male patient with right scrotal swelling and intermittent pain for 2 months. Color Doppler US demonstrated the absence of vascularity in the enlarged right testis, and the initial diagnosis was a missed testicular torsion. CT demonstrated a poorly enhancing mass rather than a missed testicular torsion with enhanced small nodular foci at the periphery. The final pathological diagnosis was testicular lymphoma.

Pseudoaneurysm of Ulnar Artery after Endoscopic Carpal Tunnel Release

  • Ryu, Sung-Joo;Kim, In-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.4
    • /
    • pp.380-382
    • /
    • 2010
  • The authors present an extremely rare case of a pseudoaneurysm of the ulnar artery as a complication of a two-portal endoscopic carpal tunnel release (ECTR). A 70-year-old man with chronic renal failure and on maintenance hemodialysis with a left arteriovenous fistula presented with paresthesia of his right hand. A clinical diagnosis of right carpal tunnel syndrome was confirmed by ultrasonography and an electro physiologic study. He underwent two-portal ECTR, and the paresthesia was much improved. However, he presented to us one month after operation with severe pain, a tender mass distal to the right wrist crease and more aggravation of the paresthesia in the ulnar nerve distribution. Doppler ultrasound was performed and revealed a hypo echoic lesion 20 mm in diameter in the right palm, with arterial Doppler flow inside connected to the palmar segment of the ulnar artery. An ulnar artery pseudoaneurysm was diagnosed and treated by ultrasound-guided percutaneous thrombin injection. Transverse color Doppler ultrasound image showed complete thrombosis of the pseudoaneurysm and flow cessation after a total injection of 500 units of thrombin. The symptoms were also improved.

AN EAST-ASIAN EXTRA-SOLAR PLANET SEARCH NETWORK

  • IZUMIURA HIDEYUKI
    • Journal of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.81-84
    • /
    • 2005
  • We are undertaking an extra-solar planet search around G-type giant stars by means of Doppler technique using an iodine absorption cell installed to the high dispersion echelle spectrograph for the 188 cm reflector at Okayama Astrophysical Observatory (Okayama Planet Search Program, OPSP). Having detected the first planet candidate (Sato et al. 2003)the search has been proved very promising. Taking advantage of this success, we are trying to develop OPSP to an international collaborative work. We here report the current status of our efforts for establishing such collaborations, namely, those with Chinese and Korean astronomers. We also propose to establish an East-Asian network to search for extra-solar planets around G-type giant stars with the transit detecting technique as well as the Doppler technique, asking other persons/groups to join us to enjoy the planet search.

A study on the implementation of multi-velocity log system using ultrasonic doppler effect (초음파 도플러 효과를 이용한 선박 종합 속도 측정 시스템 구현에 관한연구)

  • 류점수;신동우;민경선;김영길;강동균;임종곤
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.3
    • /
    • pp.38-46
    • /
    • 1996
  • In this paper, a multi-velocity log system which uses ultrasonic pulsed doppler signal is developed. The output of the system is the absoluted velcocity of the ship. By using digitral signal processing, we get the vector velocity which displays the ship's speed about fore, aft, port and starboard. And this system give us the information about depth. This multi-velocity system has a large merit that is bottom and water track velocity. In addition, this has the high accuracy and can measure the water-depth according to the deep mode. And the fish finder, echo sounder or docking system will be made by applying the speed log system.

  • PDF

PULP VITALITY TEST OF TEETH AFTER TRAUMATIC INJURIES USING LASER DOPPLER FLOWMETRY - A CASE REPORT (외상 받은 치아의 치수생활력 검사 - Laser Doppler flowmetry를 이용한 증례보고)

  • Song, Yun-Ju;Kim, Hyun-Jung;Nam, Soon-Hyeun;Kim, Young-Jin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.310-316
    • /
    • 1999
  • In the traumatized teeth, the major complications are pulp necrosis, and root resorption. The factors influencing to prognosis are the state of root development, type of injuries, quality of fixation. There are good prognosis in the case of immature teeth, minor luxation injuries. To minimize of occurrence of these complication, it is very important to determine the pulp vitality. This can help us decide whether or not to treat the teeth endodontically. But, it is difficult to determine of pulp vitality in immature teeth or traumatized teeth. In this case, pulp vitality test was done periodically on the traumatized upper central incisors, and the results were different among cold test, electric pulp test, and laser Doppler flowmetry. The conclusions were obtained from this case can be summarized as follows; 1. Pulp vitality of traumatized teeth should be negative early, but with time going, pulp vitality could be recovered. 2. The positive response of pulp vitality test was detected earlier in laser Doppler flowmetry. 3. Between cold test and electric pulp test, cold test was more reliable in determining pulp vitality.

  • PDF

COMPARISON OF LOS DOPPLER VELOCITIES AND NON-THERMAL LINE WIDTHS IN THE OFF-LIMB SOLAR CORONA MEASURED SIMULTANEOUSLY BY COMP AND HINODE/EIS

  • Lee, Jae-Ok;Lee, Kyoung-Sun;Seough, Jungjoon;Cho, Kyung-Suk
    • Journal of The Korean Astronomical Society
    • /
    • v.54 no.2
    • /
    • pp.49-60
    • /
    • 2021
  • Observations of line of sight (LOS) Doppler velocity and non-thermal line width in the off-limb solar corona are often used for investigating the Alfvén wave signatures in the corona. In this study, we compare LOS Doppler velocities and non-thermal line widths obtained simultaneously from two different instruments, Coronal Multichannel Polarimeter (CoMP) and Hinode/EUV Imaging Spectrometer (EIS), on various off-limb coronal regions: flaring and quiescent active regions, equatorial quiet region, and polar prominence and plume regions observed in 2012-2014. CoMP provides the polarization at the Fe xiii 10747 Å coronal forbidden lines which allows their spectral line intensity, LOS Doppler velocity, and line width to be measured with a low spectral resolution of 1.2 Å in 2-D off limb corona between 1.05 and 1.40 RSun, while Hinode/EIS gives us the EUV spectral information with a high spectral resolution (0.025 Å) in a limited field of view raster scan. In order to compare them, we make pseudo raster scan CoMP maps using information of each EIS scan slit time and position. We compare the CoMP and EIS spectroscopic maps by visual inspection, and examine their pixel to pixel correlations and percentages of pixel numbers satisfying the condition that the differences between CoMP and EIS spectroscopic quantities are within the EIS measurement accuracy: ±3 km s-1 for LOS Doppler velocity and ±9 km s-1 for non-thermal width. The main results are summarized as follows. By comparing CoMP and EIS Doppler velocity distributions, we find that they are consistent with each other overall in the active regions and equatorial quiet region (0.25 ≤ CC ≤ 0.7), while they are partially similar to each other in the overlying loops of prominences and near the bottom of the polar plume (0.02 ≤ CC ≤ 0.18). CoMP Doppler velocities are consistent with the EIS ones within the EIS measurement accuracy in most regions (≥ 87% of pixels) except for the polar region (45% of pixels). We find that CoMP and EIS non-thermal width distributions are similar overall in the active regions (0.06 ≤ CC ≤ 0.61), while they seem to be different in the others (-0.1 ≤ CC ≤ 0.00). CoMP non-thermal widths are similar to EIS ones within the EIS measurement accuracy in a quiescent active region (79% of pixels), while they do not match in the other regions (≤ 61% of pixels); the CoMP observations tend to underestimate the widths by about 20% to 40% compared to the EIS ones. Our results demonstrate that CoMP observations can provide reliable 2-D LOS Doppler velocity distributions on active regions and might provide their non-thermal width distributions.

Unusual US Findings of Diffuse Large B-Cell Lymphoma of the Breast: A Case Report (유방의 B세포 림프종의 비전형적 초음파 영상 소견: 증례 보고)

  • Kyung Eun Lee;Ok Hee Woo;Chung Yeul Kim;Kyu Ran Cho;Bo Kyoung Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.415-420
    • /
    • 2024
  • Lymphoma is an uncommon type of breast malignancy, with low prevalence. The ultrasonographic findings of breast lymphoma have been described as nonspecific. Breast lymphoma most commonly appears as a solitary hypoechoic mass on US, and usually shows hypervascularity on color Doppler US. Herein, we report an unusual case of breast lymphoma that presented as multiple bilateral hyperechoic nodules on US.

Differentiation of Malignant and Benign Cervical Lymph Nodes with Color and Pulsed Doppler Ultrasonography (색채 및 펄스 도플러 초음파를 이용한 경부 림프절의 양성과 악성의 감별)

  • Lee Kang-Dae;Lee Bong-Hee;Lee Yun-Woo;Lee Hwan-Ho;Ahn Kyong-Mo;Lee Young-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.17 no.1
    • /
    • pp.19-25
    • /
    • 2001
  • Objectives: The clinical efficacy of the color and pulsed Doppler ultrasound with spectral waveform analysis for differentiation of malignant from benign cervical lymphadenopathy was prospectively evaluated in cervical lymphadenopathy. Materials and Methods: Color and pulsed Doppler ultrasound examination was prospectively performed in 32 cervical lymph nodes in 28 patients. These 10 nodes from 10 patients were malignant and 22 nodes from 18 patients were benign, proved by operation, biopsy, and follow-up examination. Another 12 lymph nodes from 12 normal volunteers were evaluated as control group. The peak systolic velocity (PSV), minimal diastolic velocity (MDV) , and resistive indexes (RI) of arterial flows within the 32 lymph nodes were assessed to differentiate the malignant from benign nodes with pulsed Doppler ultrasonography. The results were qualitified with one-way ANOVA and Bonferroni method of multiple comparison. Results: The mean values of PSV of malignant, benign, and control nodes were 38.2(10.1-134)cm/sec, 23.3(9-38.5) cm/sec and 11.8(6.7-18.1) cm/sec, respectively. The mean values of MDV of them were 0.9(-7.5-10.7)cm/sec, 9.7(2.9-18.6)cm/sec and 6.5(3.7-9.3)cm/sec, respectively. However, there was no statistical significance in differentiation of malignant from benign nodes with PSV and MDV. The mean values of RI of malignant, benign, and control nodes were 0.99(0.80-1.30), 0.59(0.46-0.77) and 0.45(0.38-0.50), respectively. RI value of 0.8 is suggestive value for discrimination of malignant from benign lymphadenopathy during examination of color Doppler ultrasound of cervical lymphadenopathy. Conclusion: Color and pulsed Doppler ultrasound examination with spectral waveform analysis may be quite helpful in the differentiation between benign and malignant alterations of cervical lymph nodes.

  • PDF

High Mass X-ray Binary and IGOS with IGRINS

  • Chun, Moo-Young;Moon, Dae-Sik;Jeong, Ueejeong;Yu, Young Sam
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.95-95
    • /
    • 2014
  • The mass measurement of neutron stars or black holes is of fundamental importance in our understanding of the evolution of massive stars and core-collapse supernova explosions as well as some exotic physics of the extreme conditions. Despite the importance, however, it's very difficult to measure mass of these objects directly. One way to do this, if they are in binary systems, to measure their binary motions (i.e., Doppler shifts) which can give us direct information on their mass. Recently many new highly-obscured massive X-ray binaries have been discovered by new hard X-ray satellites such as INTEGRAL and NuSTAR. The new highly-obscured massive X-ray binaries are faint in the optical, but bright in the infrared with many emission lines. Based on the near-infrared spectroscopy, one can first understand the nature of stellar companions to the compact objects, determining its spectral types and luminosity classes as well as mass losses and conditions of (potential) circumstellar material. Next, spectroscopic monitoring of these objects can be used to estimate the mass of compact objects via measuring the Doppler shifts of the lines. For the former, broad-band spectroscopy is essential; for the latter, high-resolution spectroscopy is critical. Therefore, IGRINS appears to be an ideal instrument to study them. An IGRINS survey of these new highly-obscured massive X-ray binaries can give us a rare opportunity to carry out population analyses for understanding the evolution of massive binary systems and formation of compact objects and their mass ranges. In this talk, we will present a sample near-infrared high resolution spectra of HMXB, IGR J19140+0951 and discuss about its spectral feature. These spectra are obtained on 13th July, 2014 from IGRINS commissioning run at McDonald 2.7m telescope. And at final, we will introduce the upgrade plan of IGRINS Operation Software (IGOS), to gather the input from IGRINS observer.

  • PDF