• Title/Summary/Keyword: Doppler Effects

Search Result 297, Processing Time 0.022 seconds

A study on the pulsatile flow characteristics of Newtonian and non-Newtonian fluids in the bifurcated tubes (분기관내 뉴턴유체와 혈액의 맥동유동특성에 관한 연구)

  • Seo, Sang-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.11
    • /
    • pp.3607-3619
    • /
    • 1996
  • Experimental and numerical studies for three-dimensional pulsatile flows are conducted to investigate the flow characteristics in the bifurcated tubes. Velocity measurements in experimental study were made by both Pulsed Doppler Ultrasound(PDU) machine and Laser Doppler Anemometer(LDA) system. Glycerin is used for experimental study. Experimental results are used to verify the results of the numerical simulation. Flow characteristics of Newtonian fluid and blood in the bifurcated tubes under the steady and pulsatlie flows are numerically investigated. Finite volume method is employed for three-dimensional numerical simulations. Blood is considered as a non-Newtonian fluid and the constitutive equation of blood is used for the numerical analysis. Numerical analyses are focused on the flow patterns for various branch angles ranging from 30.deg. to 90.deg. and diameter ratios such as 1.0, 0.8, and 0.6. Pulsatile flow characteristics of blood are compared with those of Newtonian fluid. Parameter effects on axial velocity, pressure and wall shear stress distribution along the bifurcated tubes are discussed in terms of the branch angle, diameter ratio, and Reynolds number.

Partitioning Bimodal Spectrum Peak in Raw Data of UHF Wind Profiler (UHF 윈드프로파일러 원시 자료의 이중 스펙트럼 첨두 분리)

  • Jo, Won-Gi;Kwon, Byung-Hyuk;Yoon, Hong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.1
    • /
    • pp.61-68
    • /
    • 2019
  • In addition to non-meteorological echoes, meteorological echoes with large scattering effects, such as precipitation, cause errors in wind data measured by wind profiler. In the rainfall situation, the Doppler spectrum of wind profiler shows both the rainfall signal and the atmospheric signal as two peaks. The vertical radial velocity is very large due to the falling rain drop. The radial velocity contaminated by rainfall decreases the accuracy of the horizontal wind vector and leads to inaccurate weather analysis. In this study, we developed an algorithm to process raw data of wind profiler and distinguished rainfall signal and wind signal by partitioning bimodal peak for Doppler spectrum in rainfall environment.

Diagnostics of Diffuse Two-Phase Matter Using Techniques of Positron Annihilation Spectroscopy in Gamma-Ray and Optical Spectra

  • Doikov, Dmytry;Yushchenko, Alexander;Jeong, Yeuncheol
    • Journal of Astronomy and Space Sciences
    • /
    • v.36 no.3
    • /
    • pp.115-119
    • /
    • 2019
  • This paper is a part of the series on positron annihilation spectroscopy of two-phase diffuse gas-and-dust aggregates, such as interstellar medium and the young remnants of type II supernovae. The results obtained from prior studies were applied here to detect the relationship between the processes of the annihilation of the K-shell electrons and incident positrons, and the effects of these processes on the optical spectra of their respective atoms. Particular attention was paid to the Doppler broadening of their optical lines. The relationship between the atomic mass of the elements and the Doppler broadening, ${\Delta}{\lambda}_D$ (${\AA}$), of their emission lines as produced in these processes was established. This relationship is also illustrated for isotope sets of light elements, namely $^3_2He$, $^6_3Li$, $^7_3Be$, $^{10}_5B$ and $^{11}_5B$. A direct correlation between the ${\gamma}-line$ luminosity ( $E_{\gamma}=1.022MeV$) and ${\Delta}{\lambda}_D$ (${\AA}$) was proved virtually. Qualitative estimates of the structure of such lines depending on the positron velocity distribution function, f(E), were made. The results are presented in tabular form and can be used to set up the objectives of further studies on active galactic nuclei and young remnants of type II supernovae.

Effects of Yangsim-tang on the Changes of Cerebral Hemodynamics in Rats (양심탕이 백서의 뇌혈류역학 변화에 미치는 영향)

  • Shin, Sun-Ho;Jeon, Sang-Yoon;Hong, Seok;Lee, Jung-Sup
    • The Journal of Internal Korean Medicine
    • /
    • v.27 no.4
    • /
    • pp.855-863
    • /
    • 2006
  • Objectives : This study was performed to evaluate effects of Yangsim-tang extract (YST) on hemodynamics (regional cerebral blood flow (rCBF) and mean arterial blood pressure (MABP) ) in normal rats, and effects of cyclooxygenase and guanylate cyclase under YST. Methods : Laser-Doppler flowmetry (LDF) measured changes of rCBF, and a data acquisition system assembled with MacLab and Macintosh measured changes of MABP. Results : YST significantly increased rCBF, but did not change MABP. Pretreatment with indomethacin significantly inhibited rCBF increased by YST, but pretreatment with methylene blue did not significantly inhibit rCBF increased by YST. Conclusions : YST increases rCBF, and the action of this response is mediated by cyclooxygenase.

  • PDF

Renal hemodynamics in dogs with experimental hydronephrosis treated with transarterial embolization of renal artery (신장동맥색전술을 실시한 개의 실험적 수신증의 혈동학)

  • Chang, Dongwoo
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.3
    • /
    • pp.413-419
    • /
    • 2001
  • This study was performed to evaluate the renal hemodynamics using color Doppler ultrasonography in dogs with unilateral experimental hydronephrosis treated with transarterial embolization of the renal artery (TAE-RA). Experimental hydronephrosis was induced by ligation of unilateral ureter in 12 dogs. The mean resistive index (RI) value of kidney was significantly increased at 4, 9, 17 days after ligation of ureter. Unilateral hydronephrosis was established in 12 dogs at 17 days after ligation of ureter. Renal artery embolization was performed using selective catheterization in the hydronephrotic kidney of seven dogs and EKG, $SpO_2$body temperature, pulse, and respiratory rate were within normal ranges during procedures. There were no dogs expired after TAE-RA and no side effects associated with regurgitation of iohexol-ethanol solution. In color Doppler ultrasonographic findings, there was no blood flow into the embolized kidneys treated by TAE-RA, however, blood flow signal was found in contralateral normal kidney of dogs treated with TAE-RA compared to that of normal kidney in normal control group. It is concluded that TAE-RA does not affect the hemodynamics of contralateral normal kidney in dogs with experimental hydronephrosis and color Doppler ultrasonography is simple and non-invasive modality for the monitoring of the revascularization of the renal artery after TAE-RA.

  • PDF

Automatic speech recognition using acoustic doppler signal (초음파 도플러를 이용한 음성 인식)

  • Lee, Ki-Seung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.1
    • /
    • pp.74-82
    • /
    • 2016
  • In this paper, a new automatic speech recognition (ASR) was proposed where ultrasonic doppler signals were used, instead of conventional speech signals. The proposed method has the advantages over the conventional speech/non-speech-based ASR including robustness against acoustic noises and user comfortability associated with usage of the non-contact sensor. In the method proposed herein, 40 kHz ultrasonic signal was radiated toward to the mouth and the reflected ultrasonic signals were then received. Frequency shift caused by the doppler effects was used to implement ASR. The proposed method employed multi-channel ultrasonic signals acquired from the various locations, which is different from the previous method where single channel ultrasonic signal was employed. The PCA(Principal Component Analysis) coefficients were used as the features of ASR in which hidden markov model (HMM) with left-right model was adopted. To verify the feasibility of the proposed ASR, the speech recognition experiment was carried out the 60 Korean isolated words obtained from the six speakers. Moreover, the experiment results showed that the overall word recognition rates were comparable with the conventional speech-based ASR methods and the performance of the proposed method was superior to the conventional signal channel ASR method. Especially, the average recognition rate of 90 % was maintained under the noise environments.

Echocardiographic Evaluation of Cardiovascular Function in Cloned Dogs (심장 초음파를 이용한 복제견의 심혈관계 기능 평가)

  • Yeo, Ju-Hwan;Kim, Jae-Hwan;Kim, So-Young;Lee, Seung-Jun;Park, Noh-Won;Oh, Hyun-Ju;Kim, Min-Jung;Kim, Geon-A;Jo, Young-Kwang;Lee, Byeong-Chun;Eom, Kidong
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.301-307
    • /
    • 2015
  • The purpose of this study was to compare echocardiographic parameters of cloned beagle dogs with the previously reported reference range. Seven cloned dogs were assessed for anatomical features and cardiac function through left- and right-sided heart and right ventricle outflow tract from M-mode, 2D-mode, pulsed wave Doppler and tissue Doppler imaging. In all the cloned dogs, there were no abnormalities in anatomical structure and measurements were within the normal reference range. In addition, left- and right-sided myocardial function was within the normal reference range. Especially, pulmonary hypertension and right-sided heart failure frequently encountered in cloned animals were not recognized in cloned dogs. In conclusion, no evidence of cardiovascular dysfunction in mature cloned dogs could be identified either at birth or the growing stage in this study. Therefore, serious adverse effects of somatic cell nuclear transfer technology including transgenesis on cardiac morphology and function were not found in cloned dogs.

The Effects of Cervical Manipulation on Blood Flow Velocity of Cranial Artery and Pain Level in Cervicogenic Headache Patients

  • Kang, Da-Haeng;Park, Seung-Kyu;Kang, Jeong-Il;An, Chang-Sik;Kim, Yong-Nam;Yoon, Hee-Jong;Koo, Ja-Pung;Chang, Duncan;Lee, Joon-Hee
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.1 no.2
    • /
    • pp.99-106
    • /
    • 2010
  • The purpose of this study was to identify the effects of manipulation on the velocity of cerebral blood flow and level of pain in cervicogeinc headache patients. The velocity of cerebral blood flow of 30 cervicogeinc headache patients(male=15, female=15, age=$24.00{\pm}3.60$) and 33 normal subjects(male=15, female=18, age=$23.27{\pm}3.00$) was compared. The 30 cervicogeinc headache patients were divided into suboccipitalis relaxation group, cervical manipulation group, and placebo group, and each were given different interventions. The velocity of cerebral blood flow and pain level was measured before intervention, and 1, 2, 3 weeks after intervention. The velocity of cerebral blood flow was measured with the Transcranial Doppler(TCD), and pain level was measured with visual analog scale(VAS). Blood flow velocity of middle cerebral artery in cervicogeinc headache patients was slower than those in healthy subjects. Physical therapy intervention did not have significant effect on velocity of cerebral blood flow, but slowly decreased at intervention for pain level increased. The suboccipitalis relaxation group and cervical manipulation group showed significant effect in decreasing pain level compared to the placebo group(p<.05). Directly applied manipulation therapy in the neck area not only has effect on joint of cervical and soft tissue but also on blood vessels and nerves which pass the neck area, and because of those results of manual therapy seems to help recovery.

  • PDF

Mechanism of Jaeumgenby-tang on the Regional Cerebral Blood Flow, Mean Arterial Blood Pressure and Cardiac Muscle Contractile Force in Rats (자음건비탕이 국소뇌혈류량, 평균혈압, 심근수축력에 미치는 작용기전)

  • Jeong Hyun Woo;Kim Hee Seong;Yang Gi Ho
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.3
    • /
    • pp.507-513
    • /
    • 2002
  • Jaeumgenby-tang(JGT) have been used in oriental medicine for many centries as a a therapeutic agent of vertigo caused by deficiency of qi and blood. The effects of JGT on the regional cerebral blood flow(rCBF), mean arterial blood pressure(MABP) and cardiac muscle contractile force(CMF) is not known. The purpose of this Study was to investigate effects of JGT on the rCBF, MABP, CMF and mechanism of JGT induced changed rCBF, MABP, CMF. The changes of rCBF, MABP and CMF were determinated by Laser-Doppler Flowmetry(LDF). The results were as follows; JGT extract was increased rCBF, MABP and CMF in a dose-dependent, specially JGT extract was significantly increased rCBF and MABP. Pretreatment with propranolol was significantly inhibited JGT induced increase of rCBF but pretreatment with indomethacin and methylene blue were accelerated JGT induced increase of rCBF. Pretreatment with propranolol and indomethacin were inhibited JGT induced increase of MABP, but pretreatment with methylene blue was accelerated JGT induced increase of MABP. Pretreatment with propranolol was significantly inhibited JGT induced increase of CMF but pretreatment with indomethacin and methylene blue were accelerated JGT induced increase of CMF. This results suggest that JGT increased rCBF by increasing MABP and CMF and the action of JGT is mediated by adrenergic β-receptor.

A Complexity Reduced PNFS Algorithm for the OFDM System with Frequency Offset and Phase Noise (주파수 오프셋과 위상 잡음이 있는 OFDM 시스템에서 PNFS 알고리즘 간소화를 통한 복잡도 개선)

  • Kim, Do-Hoon;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.4
    • /
    • pp.499-506
    • /
    • 2012
  • In this paper, we analyze the effects of phase noise and frequency offset that cause performance degradation. Basically, we like to propose reduced PNFS(Phase Noise and Frequency offset Suppression) algorithm. The OFDM system is seriously affected by ICI component such as phase noise, frequency offset and Doppler effects. Especially, complicated processing algorithm with high complexity was required it in order to compensate those ICI components. So, we propose PNFS algorithm that can decrease complexity and compensate ICI components. We propose a method decreased complexity by approximation of parameters that affect slightly performance change and compare the quantity of conventional and revised PNFS algorithm. Also, simulation shows that BER performance of revised PNFS algorithm can be improved slightly.