Dynamic Analysis of Impact Force Alleviation of Industrial Folding-type Automatic Door on Guide Rail (산업용 접이식 자동문 안내레일에 작용하는 충격하중 완화를 위한 동역학적 해석)

  • Yun, Seong-Ho;Park, Jong-Cheon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.4
    • /
    • pp.16-21
    • /
    • 2011
  • This paper described an analysis of dynamic mechanism for the industrial two-step folding automatic door using commercial software packages. Two modeling types of operating on the guide rail, the sliding one and the rolling, were adopted to investigate effects of impact force when the door ascends the guide rail. The magnitude of impact force was found very peaklike large over an initial duration of the door's moving up. The amount of damping coefficient for alleviating this shock was controlled to such a moderate degree that the operating conditions can be obtained for the purpose of design. Moreover the behavior of both dynamic stress and deformation were observed for acquirement of structural reliabilities of the combined guide rail and rolling mechanism. This research will be a very useful tool in the near future for the dynamic analysis of the multi-step folding automatic door.

Safety Improvement of an Automatic Door System Using a Disturbance Observer and Neural Network (외란관측기와 신경 회로망을 이용한 자동문 시스템의 안전성 개선)

  • Yoo, Young-Dong;Lee, Kyo-Beum;Hong, Suk-Kyo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.401-410
    • /
    • 2010
  • This paper proposes an automatic door system which improves the safety of conventional automatic door systems by complementing the external safety sensors. Disturbance observer using the model of automatic door system and neural network is designed. The proposed algorithm compares the observed disturbance with the output of neural network. Experimental results are presented to illustrate the feasibility of the proposed control strategy. The proposed strategy is expected to improve the safety of an automatic door system.

IoT Open-Source and AI based Automatic Door Lock Access Control Solution

  • Yoon, Sung Hoon;Lee, Kil Soo;Cha, Jae Sang;Mariappan, Vinayagam;Young, Ko Eun;Woo, Deok Gun;Kim, Jeong Uk
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.8-14
    • /
    • 2020
  • Recently, there was an increasing demand for an integrated access control system which is capable of user recognition, door control, and facility operations control for smart buildings automation. The market available door lock access control solutions need to be improved from the current level security of door locks operations where security is compromised when a password or digital keys are exposed to the strangers. At present, the access control system solution providers focusing on developing an automatic access control system using (RF) based technologies like bluetooth, WiFi, etc. All the existing automatic door access control technologies required an additional hardware interface and always vulnerable security threads. This paper proposes the user identification and authentication solution for automatic door lock control operations using camera based visible light communication (VLC) technology. This proposed approach use the cameras installed in building facility, user smart devices and IoT open source controller based LED light sensors installed in buildings infrastructure. The building facility installed IoT LED light sensors transmit the authorized user and facility information color grid code and the smart device camera decode the user informations and verify with stored user information then indicate the authentication status to the user and send authentication acknowledgement to facility door lock integrated camera to control the door lock operations. The camera based VLC receiver uses the artificial intelligence (AI) methods to decode VLC data to improve the VLC performance. This paper implements the testbed model using IoT open-source based LED light sensor with CCTV camera and user smartphone devices. The experiment results are verified with custom made convolutional neural network (CNN) based AI techniques for VLC deciding method on smart devices and PC based CCTV monitoring solutions. The archived experiment results confirm that proposed door access control solution is effective and robust for automatic door access control.

The Evaluation of Adaptability of Three Ever-green Perennial Herbaceous South Korea Native Plants under In-door Light Intensities

  • Sang Yeob Lee;Kyungtae Park;Bo Kook Jang;Cheol Hee Lee;Ju Sung Cho
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2020.08a
    • /
    • pp.67-67
    • /
    • 2020
  • Though there is an on-going need for the diversity of ornamental plants for in-door environment, their growth and stress adaptability in comparatively low light intensity condition require further studies for implementation. Here investigates the growth and chlorophyll fluorescence parameters of Farfugium japonicum (L.) Kitam, Liriope muscari (Decne.) L.H.Bailey and Acorus gramineus Aiton under several light intensities which were based on common in-door environment. The growth measurement of the plants included the quantity, length, width and SPAD value of the leaves. Calculated values of Fm/Fo, Fv/Fm, Pi_Abs, ETo/RC and DIo/RC were used as the parameters of the chlorophyll fluorescence under 10, 50, 100 and 200 PPFD (μmol·m-2·s-1) light intensities. In-door plants group was put in a closed room allowing no other light sources for 10 weeks and the control group was put in glass-greenhouse for the same period. The overall in-door growth of L. muscari was not significantly different in all light intensities compared to the control group and even showed the higher SPAD values. Also, an increasing tendency of Pi_Abs value under 10 to 100 PPFD was observed implying that L.muscari could adapt well to in-door environment. Measurement of A. gramineus growth mostly showed the highest values in the control group especially in the number of the leaves. Nevertheless, chlorophyll fluorescence parameters showed no significant value difference between in-door and the control groups and thus, A. gramineus might have possibility of successful adaptation to in-door environment. F. japonicum showed deficient growth in plant height and leaf length compared to the control but, it seemed to be able to sustain ornamental value under in-door light intensities. Furthermore, Pi_Abs and DIo/RC values were increased under in-door light conditions suggesting potential adaptability of F. japonicum.

  • PDF

Study on the Test Methods and Performance Criterion of High Insulated Door (고기밀.고단열 문의 성능평가 및 기준설정에 관한 연구)

  • Kang, Jae-Sik;Choi, Gyoung-Seok;Kim, Kyoung-Woo;Lee, Seung-Eon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.618-622
    • /
    • 2009
  • About a Structure is performance insulation include air-tight is fundamental performance for energy-saving. The Apartment house of permission balcony enlarged to increase the requirement of market of high-effective door. Since 2001 years the window and wall of insulation performance stronger frailty than keep up performance insulation that increase influence building energy generated heat loss at door. In study on presentation that high-insulation, air-tight door about experimental method and performance standard.

  • PDF

Numerical Analysis on Features of Airflow through Open Door in Pressure Differential System (급기가압 제연시스템의 방연풍속 형성특성에 대한 수치해석적 분석)

  • Kim, Jung-Yup;Rie, Dong-Ho;Kim, Ha-Young
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.463-468
    • /
    • 2008
  • The fact that the major cases of life casualties are from smoke in the fire accidents and the expected steep increase of skyscrapers, huge spaces, multiplexes and huge scaled underground spaces demand establishment of efficient smoke countermeasure. In pressure differential systems for smoke management, the speed of airflow through open door between accommodation and lobby should be maintained over 0.5m/s on the whole area of door to prevent smoke from infiltrate into evacuation root when the door is open for refuge. The numerical analysis on features of airflow through open door are carried out and the results are presented.

  • PDF

Initial Rotor Position Detection a PM Synchronous Motor and Speed Control of an Elevator Door (영구자석 동기전동기의 회전자 초기위치 검출 및 엘리베이터 도어의 속도제어)

  • Song, Ki-Young;Oh, Hyun-Cheal;Cho, Kwan-Yuhl;Kim, Hag-Wone
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.556-564
    • /
    • 2013
  • This paper proposes an initial rotor position detecting algorithm of a PM synchronous motor using an incremental encoder. The proposed algorithm estimates the phase offset between the rotor magnetic flux and the Z-pulse of the incremental encoder by applying six aligning mode current control. The absolute rotor position for driving a PM synchronous motor is calculated by using the phase offset of the Z pulse and A, B pulse signals of the encoder. The PMSM drives based on the estimated rotor position is applied to the elevator door system. The door length is measured on line at first setup of the elevator. The speed control for open, close, and reopen of the elevator door is also presented and the proposed algorithm for the elevator door system is verified by experiment.

Construction of Vehicle Door Impact Beam Using Hot Stamping Technology (핫스탬핑에 의한 자동차 도어 임팩트빔의 개발)

  • Lee, Hyun-Woo;Hwang, Jung-Bok;Kim, Sun-Ung;Kim, Won-Hyuck;Yoo, Seung-Jo;Lim, Hyun-Woo;Yum, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.6
    • /
    • pp.797-803
    • /
    • 2010
  • A vehicle door impact beam made of a thin sheet of steel has been constructed using hot stamping technology with the aim of ensuring occupant safety in the event of a side collision. This technology has been used to increase the strength of the vehicle body parts and to reduce the weight of the door impact beam as well as the number of work processes. Mechanical tests were performed to determine the material properties of the hot-stamped specimen and the results of the tests were used as input data in stamping and structural simulation in order to obtain the optimal design of door impact beam. The strength of the hot-stamped door impact beam increased to a value that was 102% higher than that of conventional pipe-shaped door impact beam. A weight reduction of 34% was also achieved.

Implementation of an Automatic Door Lock System Using DTMF Signal of a Mobile Phone (모바일 단말기의 DTMF 신호를 이용한 자동 도어락 시스템 구현)

  • Bae Ki-Won;Yang Doo-Yeong
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.1
    • /
    • pp.8-13
    • /
    • 2006
  • In this thesis, an automatic door lock system using a dual tone multiple frequency(DTMF) signal generated as pushing the key button of mobile phone is proposed and implemented. This system consists of a transmitter module and a receiver module for processing the DTMF signal of mobile phone. The DTMF signal of mobile phone connected with ear-phone jack enter into the input terminal of DTMF receiver and those are encoded by a code-converter with 4-bits binary format in the DTMF receiver. The encoded output signals are transmitted to the amplitude shift keying(ASK) modulator of transmitter module and the modulated ASK signals which are converted into radio frequency(RF) signals propagate in a free space. The RF signals passed through a free space are demodulated by the ASK demodulator of receiver module and the demodulated ASK signals are sent to a micro-controller unit(MCU). The output signals processed by the MCU are compared with the secreted identification number which is prerecorded in a microprocessor and are transferred to a power relay. If the result is the same, the automatic door lock system opens a door. In the opposite case, it maintains closing the door. The implemented automatic door lock system operates well in mobile environments.

  • PDF

Calculation Formula for Shielding Thickness of Direct Shielded Door installed in Treatment Room using a 6 MV X-ray Beam (6 MV X-선 빔을 사용하는 치료실에 설치되는 직접 차폐식 도어의 차폐 두께 계산식)

  • Park, Cheol Seo;Kim, Jong Eon;Kang, Eun Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.545-552
    • /
    • 2020
  • The purpose of this study is to derive a lead thickness calculation formula for direct-shielded doors based on NCRP Report No.151 and IAEA Safety Report Series N0.47. After deriving the dose rate calculation formula for the direct shielded door, this formula was substituted for the lead shielding thickness calculation formula to derive the shielding thickness calculation formula at the door. The lead shielding thickness calculated from the derived direct shielded door shielding thickness calculation formula was about 6% lower than that calculated by the NCRP and IAEA secondary barrier shielding thickness calculation methods. This result is interpreted as meaning that the thickness calculation is more conservative from the NCRP and IAEA secondary barrier shielding thickness calculation methods and fits well for secondary beam shielding. In conclusion, it is thought that the formula for calculating lead shielding thickness of the direct shielded door derived in this study can be usefully used in the shield design of the door.