• Title/Summary/Keyword: Door step equipment

Search Result 7, Processing Time 0.02 seconds

A Design on the TMS-DCU Interface for Low and High Level Railway Platforms (저상 및 고상 철도 승강장 겸용 승강문 제어유닛과 열차모니터링시스템의 인터페이스 설계)

  • Kim, Chul-Su;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.325-330
    • /
    • 2014
  • In order to operate trains both mainline railroad platform and metropolitan subway line platform, it is necessary to develop the door step equipment of the rolling stock regardless of low(500mm, mainline) and high level platforms(1,135mm, metropolitan subway line) because of the requisite door safety system. In this study, TMS-DCU interface is studied for low and high level railway platforms. As a result, Design circuit of TMS(Train Management System)-DCU(Door Control Unit) interface is suitable for telescopic sliding type doorstep unit to minimize damage to the carbody underframe of railway vehicles.

Analysis on Facilities & Basic Equipment of School Foodservice Safety in Pohang area (포항지역 학교급식의 안전성을 위한 학교 급식 조리실의 기본 시설.설비 조사)

  • Yun, Mi-Yeon;Lee, In-Suk
    • Journal of the Korean Dietetic Association
    • /
    • v.12 no.3
    • /
    • pp.264-276
    • /
    • 2006
  • The purpose of this study was to propose HACCP system implementation properly and to secure the food safety of school foodservices in Pohang city since the proper facilities and equipment should be key factors in food safety and production. So this study was designed to evaluate existing equipment in food production area, receiving and dining area, and employee facilities. Questionnaire was mailed to 107 school foodservice dietitians in Pohang area and 97 were responded (90.7% response rate). Approximately sixty percent of foodservices were not available separate receiving or polluted area, fifty one percent were installed screen door for insecticidal and temperature and humidity control, and these environmental conditions were hard to keep kitchen dry and sanitary condition. Usually public schools were better equipped than private schools. Forty three percent of school foodservice had initial use of non-foodservice, opened before 1994, and thirty three percent of elementary school foodservice. Among employee facilities, hand washing sanitation stand was prepared seventy nine percent (78.9%) of school foodservices. Dietitians chose outworn equipment and facilities (30.9%), difficulties of maintaining standard temperature and humidity for foodservice (20.6%), lacking separate receiving or polluted area (13.4%), indirect contamination of water hoss (10.3%), and lacking employee facilities (10.3%) as critical points to correct in school foodservice. Therefore governmental regulating agencies must review and approval of plans prior to new construction or extensive remodeling of school foodservice facilities. In addition to these requirement, plan must be set-up step by step to implement HACCP system properly.

  • PDF

A Study on the Control Method of Hand & Automatic Operation of On-Off Wiring of an Easy Elevator (간이 엘리베이터 수.자동 개폐배선 제어방식에 관한연구)

  • Wee, Sung-Dong;Gu, Hal-Bon;Kim, Tae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.1107-1112
    • /
    • 2002
  • An easy elevator originated is an opened system to compare an existing equipment, and learning efficient is high as a wiring that the sequence control circuit is on and off. The structure of an equipment to be controled from the first floor to the fifth floor is constructed by a lamp to express the function of the open-close of the door according to the cage moving, to express the mechanical actuation of the forward-reverse break and motor of load and of hand-worked control component of Push-Button S/W, L/S and Relay. In order to act of the elevator function that these components connected, designed the auto program and the sequence control circuit. Consequently the process that these(1~5steps) operated the cage with an auto program of the elevator and the sequence control circuit is controled by the step of forward and reverse that the L/S1~L/S5 of sensor adjust function let posit, by the adjustable S/W1~S/W5 of PLC testing panel and the S/W1~S/W5 which installed on the transparent acryl plate of a frame. In here, improved apparatus is the learning equipment of combined use to study the principle and the technique of the originated sequence control circuit and the auto program of PLC.

  • PDF

A Study on the Wiring Control Method of Hand & Auto Operation of an Easy Elevator (간이 승강기 수·자동 배선제어방식에 관한 연구)

  • 위성동;구할본
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.4
    • /
    • pp.351-357
    • /
    • 2003
  • An easy learning elevator originated is opened to compare the existed teaming equipment, and it had a high studied efficiency that the sequence control circuit can open and close with the wire. The structure of equipment to be controlled from the first floor to the fifth floors is demostrated by the constructive apparatus with the lamps to express the function of the open-close of the door according to the cage moving with a mechanical actuation of the forward reverse breaker and the motor of load, and the mechanical actuation of hand-operation control components of push-button S/W and L/S and relay etc. These components let connect each other in order to control of the elevator function with the auto program and the designed sequence control circuit. Consequently the cage could go and come till 1∼5 steps with an auto program of the elevator and the sequence control circuit. The sequence control circuit is controlled by the step of forward and reverse to follow as that the sensor function of L/S1 ∼ L/S5 let posit with the control switchs of S/W1 ∼ S/W5 of PLC testing panel and switchs of S/W1 ∼ S/W5 installed on the transparent acryl plate of the frame. In here, improved apparatus is the hand-auto operation combined learning equipment to study the principle and technique of the originate sequence control circuit and the auto program of PLC.

A Study on the Core Noise Reduction Techniques of Power Transformers (전력용 변압기 철심소음 저감기술에 관한 연구)

  • Kweon, Dong-Jin;Koo, Kyo-Sun;Cho, Ik-Choon;Kim, Yoo-Hyun;Kim, Yung-Sig
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.1962-1969
    • /
    • 2008
  • According to the increase of power demand and expansion of downtown, it is necessary to install transformers additionally in operating substations and construct substations in residential area. But the public complaint is increased due to the transformer noise of the substation. KEPCO has used a vibration preventing pad, various soundproof walls and an encloser to transformers in outdoor substations, and a soundproof door, shutter and wind-path soundproof equipment in indoor substations to block the sound propagation of the transformers. But these noise reduction methods are not satisfied. It should be considered to reduce transformer noise itself. In this paper, we investigated core noise reduction techniques to develope a low noise transformer. The techniques to reduce core noise of the transformer are application of high permeability grain oriented silicon sheets, decrease of magnetic flux density of core, application of 6step-lap core stacking method, improvement of core binding method(binding addition, band fixing) and application of rubber damper in oder to reduce transmission of core vibration, etc.

A Study on the wiring Control Method of Hand & Auto Operation of an easy Elevator (간이 승강기 수.자동 배선제어방식에 관한 연구)

  • Wee, Sung-Dong;Gu, Hal-Bon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.596-602
    • /
    • 2002
  • An easy elevator for learning originated is opened to compare the existed learning equipment, and it had a high studying efficient that the sequence control circuit can opens and closes with the wire. The structure of equipment to be controlled from the first floor to the fifth floors is demonstrated a constructive apparatus by a lamp atc to express the function of the open-close of the door according to the cage moving with a mechanical actuation of the forward-reverse breaker and the motor of load and a mechanical actuation of hand-operation control components of push-button S/W and L/S and relay etc. These components let connects each other in order to control of the elevator function with the auto program and the designed sequence control circuit. Consequent1y the process of these functions of 1~5steps could operates the cage with an auto program of the elevator and the sequence control circuit. The sequence control circuit is controlled by the step of forward and reverse to follow as that the sensor function of the L/S1~L/S5 let posit with the control switchs of S/W1~S/W5 of PLC testing panel and switchs of S/W1~S/W5 installed on the transparent acryl plate of the frame. In here, improved apparatus is a hand-auto operation combined learning equipment to study the principle and a technique of the originated sequence control circuit and the auto program of PLC.

  • PDF

6TALK : Implementation of NAT-PT/SIIT and enhanced ALG

  • 이주철;호용근;신명기;김형준
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.701-705
    • /
    • 2002
  • This paper describes implementation of IPv6-IPv4 transition toolbox named as 6TALK(IPv6 TrAansLator of Krv6) and some scenarios using 6TALK which enables IPv6 island to connect other IPv6 island or IPv4 island seamlessly. 6TALK implements some transition mechanisms suggested in NGTrans Working Group of IETF. Those mechanisms are composed of basic mechanism, tunneling, and applied mechanism such as DSTM. 6TALK provides functions which enable IPv6 network at the edge of existing network to communicate with IPv4 network by using these transition mechanisms. As major transition mechanisms in 6TALK we adopt NAT-PT/SIIT and DSTM/DSTM options and as implementation environment we use Linux Kernel 2.4.18 and Netfilter framework. Software modules implemented in Linux kernel was ported to hardware box using Motorola MPC 8260 processor. The transition mechanisms used in 6TALK are the ones predicted to be used in initial transition step to IPv6.

  • PDF