• 제목/요약/키워드: Door

검색결과 1,916건 처리시간 0.042초

방화문 시공시 현장품질관리지침 적용에 관한 연구 (A Study on the Application of Quality Management to Fire Door Construction)

  • 최동호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.90-91
    • /
    • 2019
  • When the fire door is recently installed in the field, there are frequent cases where the fire door is manufactured with fire door having low quality or different structure compared to the performance that the fire door producer has confirmed in the performance test or the construction specification. Accordingly, on-site quality management and maintenance guideline for fire doors were presented. In this paper, we tried to explain the requirements for the construction of fire doors during the on-site quality management and maintenance guideline for fire doors presented in the study.

  • PDF

공동주택 세대 현관 방화문 구조에 관한 통계적 분석 (Statistical Analysis on the Structure of the Front Door in Apartment House)

  • 심한영;박원준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.23-24
    • /
    • 2021
  • Since 2011, apartment houses account for about 41% of the fires in residential facilities for the past 10 years. Fire-resistant performance of fire doors is becoming more important to prevent the spread of fire in apartment houses. This research analyzed the structure of fire door through each 10 DB based on the quality inspection report of Continuous Acquisition & Life-cycle Support(CALS) from 2016 to 2020, which passed the fire performance test based on the laws and notices of domestic fire door. Therefore, based on the results of the analysis of DB in the future, we will conduct a study on structural improvement and addition for fireproof performance improvement of fire door.

  • PDF

다중이용시설의 피난방화문에 관한 연구 (Study of evacuation fire doors in multiple facilities)

  • 차종호
    • 한국산학기술학회논문지
    • /
    • 제15권12호
    • /
    • pp.7380-7384
    • /
    • 2014
  • 피난방화문이란 기존에 성능을 인정받은 방화문의 전면에 축광도료를 바르고 손잡이 부근에는 시온도료를 발라 제작한 방화문으로 기존에 방화설비로만 사용되었던 방화문에 피난 및 안전 기능을 추가, 방화문 자체가 피난설비로서의 기능을 겸용하는 설비이다. 피난안전방화문의 휘도는 기존의 유도표지 휘도(60분후 7mcd)이상의 성능으로 한국소방산업기술원의 휘도시험을 통과한 설비로, 화재 시 가시성의 면적이 피난구유도등에 비해 크며 연기의 하강에도 방화문 아랫부분의 방광상태가 관찰되어 피난자들의 피난유효 시간을 연장시켜 줄 것으로 사료된다. 손잡이 부근에 발라져 있는 시온도료는 일정온도에 도달하면($70^{\circ}C$) 색상이 변화 위험경고가 방화문 바탕에 나타나게 되어 화재 시 피난자들이 방화문 손잡이에 입을 수 있는 1차 재해를 예방할 수 있으며, 화재공간에 진입을 하여야 하는 소방관들에게는 역화 가능성을 사전에 인지 안전 사고를 예방하는데 도움을 줄 것으로 판단된다.

LFT소재 특성을 고려한 Door Carrier Plate 변형 해석 (Warpage analysis of a Door Carrier Plate in the injection molding Considering the characteristics of LFT)

  • 유호영;박시환
    • 한국산학기술학회논문지
    • /
    • 제14권8호
    • /
    • pp.3625-3630
    • /
    • 2013
  • 도어 모듈은 모듈화의 대표적인 예로 여러 부품들은 모듈형태로 완성하여 완성차 업체의 원가절감 및 조립시간 단축, 품질 향상 등에 큰 기여를 이루었다. 주요 부품중의 하나인 Door carrier plate는 주로 steel을 이용한 press 성형이 주였으나 최근에는 PP-LFT(유리 장섬유 강화PP)를 사용한 사출 공법을 적용함으로써 형상자유도를 높혀 모듈에 부착되는 많은 종류의 부품들을 통합할 수 있게 되었으며 중량 절감을 이룰 수 있게 되었다. 하지만 사출 성형시 제품의 형상 및 gate위치 설정의 한계성과, LFT의 특성에 의하여 변형이 비교적 심해 일반적으로 시사출 진행 후 보상 가공을 진행하여 조립성을 개선한다. 이러한 사후 수정 공정은 금형의 품질 저하 및 생산원가 상승의 주요인이다. 부분적으로 사출 CAE를 적용하여 warpage정도를 예측하나 그 신뢰성 확보에 어려움을 겪고 있다. 따라서 LFT를 사용하는 Door carrier plate에 대한 해석 신뢰성을 확보할 수 있는 기법으로 hyper-mesh에서 1차 mesh작업 후 moldlfow 자체 tool을 이용하여 mesh의 두께 구현성을 높혔으며, fiber orientation해석을 위하여 ARD-RSC model을 적용하였다.

현장 체험학습중심 환경교육 연수 프로그램 평가 연구: 대구광역시.경상북도 자연 체험교육 교원 연수를 중심으로 (Evaluation of Teachers' In-service Training Program of Out-door Learning Centered Environmental Education : Cases of Taegu City and Kyungsangpookdo)

  • 윤기순;서혜애;류승원;권덕기
    • 한국환경교육학회지:환경교육
    • /
    • 제14권2호
    • /
    • pp.95-105
    • /
    • 2001
  • Out-door learning activity in environmental education has been emphasized as an effective method in environmental education since the aims of environmental education emphasize students'value, attitude, actions as well as knowledge. In order to implement successfully out-door learning activity in environmental education classrooms, teachers'perceptions to environmental problems and experiences at fields are essential. An environmental education network among the metropolitan city and provincial office of education, nongovernmental organization of environmental movement and education and university was established and a teachers'in-service training program of out-door learning centered environmental education was implemented. The program was developed in order to 1) connect environmental education with the regional environmental situations, 2) provide teachers with opportunities to participate in an out-door learning program, and 3) train teachers to be environmental education leaders of out-door learning. For evaluation of the program, responses of participants to questionnaire were analyzed. Most of teachers responded that their perception of environment was changed positively after the participation in the program. This study suggested that a future planning of a teachers'in-service training program of out-door learning centered environmental education should be developed in considerations of arranging enough hours for out-door learning at regional environmental sites, applying performance assessment, providing teachers with multiple opportunities with programs in different levels including enriched programs, and establishing an environmental education network among nongovernmental organization of environment movement and education, university, and local offices and department of education.

  • PDF

3,4호선 도시철도 전동차 도어엔진의 개발 역사에 관한연구 (A Study on History of Rolling Stock Door Engines of Seoul Metro Line No.3 and No.4)

  • 장성철;이찬희;전관수;손영진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1352-1359
    • /
    • 2010
  • It is said that the number of people using public transportation has risen about 220 thousand over 3 years which was 1019 people average a day in 2006 and 1041 people last year. It is also said that the number of people using subway has increased by 198 thousand and the number of people using bus by 22 thousand. Can you imagine how many door engines work at the same time if we count Metro line no.1 to no.4 which consist of total 120 subway stations? A train has 80 door engines and Metro line trains have 9600 door engines all together. Which explains it quite simple how much Satefy, Durability and Sustainability need to be focused in Door Engines. Although it's not the whole part of door engines in Seoul Metro Line, And Metro No.4's door engines are operated by the method called mixture of mechanical type and belt type. And the last one is being used in the brand-new Metro train line No.3 which is being operated by electricity motor, instead of the old methods which use air pressure to operate a door engine. I'm sure you will agree that Safety is the first priority of Metro train and next follow comfortability and quickness. I think all I've talked so far make it the first step for the Safety of Metro train for you to understand the unit of a Door Engine.

  • PDF

스크린도어가 설치된 지하철 승강장의 화재유동 전산 수치 모사를 이용한 스크린도어의 화재 영향 연구 (Effect of Platform Screen Door on fire in the subway station)

  • 장용준;정우성;박원희;김학범
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1337-1345
    • /
    • 2007
  • 본 연구는 플랫폼 스크린도어가 설치된 역사에서 화재시 스크린도어에 의한 효과와 화재에 대한 방재연구를 체계적으로 진행하기 위한 기초연구이다. 본문에는 스크린 도어의 종류와 특징에 대하여 기술하였다. 본 연구의 대상이 되는 스크린 도어에는 완전밀폐형이 설치된 역사를 대상으로 하였으며 승강장 종류는 섬식 승강장이다. 스크린 도어가 설치된 역사의 화재유동 전산수치모사에 화재전용 CFD code를 이용하여 수행하였다. 플랫폼 스크린도어의 영향을 분석하기 위하여 스크린도어가 설치된 경우와 설치되지 않은 경우를 해석 하였다. 또한 화원의 위치는 승강장과 선로부에 있는 경우로 나누었다. 화원의 성장시나리오는 Ultrafast model로 하였으며, 화원크기는 10MW로 하였다. 해석결과 플랫폼 스크린도어가 설치된 경우는 화원의 위치가 승강장에 있을 때 온도 및 연기의 전파가 주 탈출구인 계단에까지 4분 이내로 전파된다. 선로부에 있을 때는 스크린 도어에 의해 열, 연기 전파의 차단 효과가 있었다.

  • PDF

스크린도어(PSD)의 개폐율에 따른 피난소요시간 분석에 관한 연구 (Study on the Evacuation Time Analysis by Platform Screen Door Opening Rate)

  • 김민재;민세홍
    • 한국화재소방학회논문지
    • /
    • 제30권4호
    • /
    • pp.59-64
    • /
    • 2016
  • Platform Screen Door System (PSD)는 지하철 승객의 편의 및 안전을 위해 설치되기 시작하였고, 현재 전국 9개 운영기관이 관리하고 있는 824개 역사 중 전체의 71.8%에 해당하는 592개 역이 PSD를 운영 중에 있다. 본 연구에서는 전동차 정차 위치에 따른 PSD와 전동차 가동문 사이의 개폐율 변화를 분석하였고, 수도권 지하철을 운행 중인 기관에서 제공받은 재차인원 자료 분석 및 피난시뮬레이션을 통해 각 역사별 피난소요시간을 산정하였다. 연구결과 승객이 매우 혼잡하게 밀집되는 일부 고밀도 역사에서는 PSD 개폐율에 따라 매우 위험한 상황이 초래될 수 있음을 알 수 있었다. 특히 정위치에서 7 m 벗어난 곳에 정차할 경우 PSD의 고정 안전보호벽과 맞물려 열차 출입문 절반 이상이 폐쇄되는 것으로 분석되었다. 이러한 문제점을 개선하기 위해 기(旣) 설치된 PSD 고정안전보호벽을 모두 개폐 가능한 비상문으로 교체 및 개량하는 것을 제안한다.

지하상가 출입구 방풍문 설치에 따른 피난안전해석 (Evacuation Simulation for the Exit with a Windbreak Door in Underground Arcade)

  • 최영상;전흥균;추홍록
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.1-10
    • /
    • 2009
  • 지하상가는 특성상 출입구에 문을 설치할 경우 피난안전에 미치는 영향을 더 면밀하게 분석할 필요가 있다. 본 연구에서는 이미 사용 중에 있는 지하상가의 출입구 중 일부 출입구에 문을 설치하는 경우에 대해 CFAST로 화재시뮬레이션을 수행하고 그 결과를 building EXODUS 피난시뮬레이션의 위험인자로 활용하여 화재위험을 고려한 피난해석을 하였다. 지하상가의 6개 출입구 중에 2곳에 문을 설치할 경우에 대해 화재피난과 일반피난으로 나누어 1,088명에 대해 피난해석을 하였다. 일반피난의 경우는 문 설치에 따른 영향이 거의 없었으나 화재피난의 경우는 문 설치로 인해 약 110초의 피난지연이 발생하였다. 또 자동문이 설치된 경우는 자동문이 열리지 않을 때가 문 설치 전보다 670초 피난지연이 발생하였다. 따라서 자동문은 화재감지기와 연동하여 개방된 상태로 정지하도록 설치되어야 하고, 문을 설치할 경우 피난안전을 위해 피난유도표시를 보강하는 것도 필요하다.